Search
Find a vulnerability
Search criteria
36 vulnerabilities found for simatic_cn_4100_firmware by siemens
CVE-2026-22925 (GCVE-0-2026-22925)
Vulnerability from nvd – Published: 2026-05-12 08:20 – Updated: 2026-05-12 13:27
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application is susceptible to resource exhaustion when subjected to high volume of TCP SYN packets
This could allow an attacker to render the service unavailable and cause denial-of-service conditions by overwhelming system resources.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22925",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-12T13:27:07.360737Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T13:27:38.628Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V5.0). The affected application is susceptible to resource exhaustion when subjected to high volume of TCP SYN packets\r\nThis could allow an attacker to render the service unavailable and cause denial-of-service conditions by overwhelming system resources."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:20:56.636Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-22925",
"datePublished": "2026-05-12T08:20:56.636Z",
"dateReserved": "2026-01-13T15:21:45.769Z",
"dateUpdated": "2026-05-12T13:27:38.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22924 (GCVE-0-2026-22924)
Vulnerability from nvd – Published: 2026-05-12 08:20 – Updated: 2026-05-13 09:51
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application does not properly restrict unauthenticated connections and is susceptible to resource exhaustion conditions.
This could allow an attacker to disrupt normal operations or perform unauthorized actions, potentially impacting system availability and integrity.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22924",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T01:40:31.029305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T09:51:24.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V5.0). The affected application does not properly restrict unauthenticated connections and is susceptible to resource exhaustion conditions.\r\nThis could allow an attacker to disrupt normal operations or perform unauthorized actions, potentially impacting system availability and integrity."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:20:55.135Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-22924",
"datePublished": "2026-05-12T08:20:55.135Z",
"dateReserved": "2026-01-13T15:21:45.768Z",
"dateUpdated": "2026-05-13T09:51:24.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2673 (GCVE-0-2026-2673)
Vulnerability from nvd – Published: 2026-03-13 13:23 – Updated: 2026-05-18 19:23
VLAI
Title
OpenSSL TLS 1.3 server may choose unexpected key agreement group
Summary
Issue summary: An OpenSSL TLS 1.3 server may fail to negotiate the expected
preferred key exchange group when its key exchange group configuration includes
the default by using the 'DEFAULT' keyword.
Impact summary: A less preferred key exchange may be used even when a more
preferred group is supported by both client and server, if the group
was not included among the client's initial predicated keyshares.
This will sometimes be the case with the new hybrid post-quantum groups,
if the client chooses to defer their use until specifically requested by
the server.
If an OpenSSL TLS 1.3 server's configuration uses the 'DEFAULT' keyword to
interpolate the built-in default group list into its own configuration, perhaps
adding or removing specific elements, then an implementation defect causes the
'DEFAULT' list to lose its 'tuple' structure, and all server-supported groups
were treated as a single sufficiently secure 'tuple', with the server not
sending a Hello Retry Request (HRR) even when a group in a more preferred tuple
was mutually supported.
As a result, the client and server might fail to negotiate a mutually supported
post-quantum key agreement group, such as 'X25519MLKEM768', if the client's
configuration results in only 'classical' groups (such as 'X25519' being the
only ones in the client's initial keyshare prediction).
OpenSSL 3.5 and later support a new syntax for selecting the most preferred TLS
1.3 key agreement group on TLS servers. The old syntax had a single 'flat'
list of groups, and treated all the supported groups as sufficiently secure.
If any of the keyshares predicted by the client were supported by the server
the most preferred among these was selected, even if other groups supported by
the client, but not included in the list of predicted keyshares would have been
more preferred, if included.
The new syntax partitions the groups into distinct 'tuples' of roughly
equivalent security. Within each tuple the most preferred group included among
the client's predicted keyshares is chosen, but if the client supports a group
from a more preferred tuple, but did not predict any corresponding keyshares,
the server will ask the client to retry the ClientHello (by issuing a Hello
Retry Request or HRR) with the most preferred mutually supported group.
The above works as expected when the server's configuration uses the built-in
default group list, or explicitly defines its own list by directly defining the
various desired groups and group 'tuples'.
No OpenSSL FIPS modules are affected by this issue, the code in question lies
outside the FIPS boundary.
OpenSSL 3.6 and 3.5 are vulnerable to this issue.
OpenSSL 3.6 users should upgrade to OpenSSL 3.6.2 once it is released.
OpenSSL 3.5 users should upgrade to OpenSSL 3.5.6 once it is released.
OpenSSL 3.4, 3.3, 3.0, 1.0.2 and 1.1.1 are not affected by this issue.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-757 - Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade')
Assigner
References
5 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| OpenSSL | OpenSSL |
Affected:
3.6.0 , < 3.6.2
(semver)
Affected: 3.5.0 , < 3.5.6 (semver) |
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
Date Public
2026-03-13 14:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-03-13T15:15:21.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/03/13/3"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2026-2673",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-17T17:17:17.444679Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T19:23:37.078Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T12:08:46.771Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OpenSSL",
"vendor": "OpenSSL",
"versions": [
{
"lessThan": "3.6.2",
"status": "affected",
"version": "3.6.0",
"versionType": "semver"
},
{
"lessThan": "3.5.6",
"status": "affected",
"version": "3.5.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Viktor Dukhovni"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Viktor Dukhovni"
}
],
"datePublic": "2026-03-13T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Issue summary: An OpenSSL TLS 1.3 server may fail to negotiate the expected\u003cbr\u003epreferred key exchange group when its key exchange group configuration includes\u003cbr\u003ethe default by using the \u0027DEFAULT\u0027 keyword.\u003cbr\u003e\u003cbr\u003eImpact summary: A less preferred key exchange may be used even when a more\u003cbr\u003epreferred group is supported by both client and server, if the group\u003cbr\u003ewas not included among the client\u0027s initial predicated keyshares.\u003cbr\u003eThis will sometimes be the case with the new hybrid post-quantum groups,\u003cbr\u003eif the client chooses to defer their use until specifically requested by\u003cbr\u003ethe server.\u003cbr\u003e\u003cbr\u003eIf an OpenSSL TLS 1.3 server\u0027s configuration uses the \u0027DEFAULT\u0027 keyword to\u003cbr\u003einterpolate the built-in default group list into its own configuration, perhaps\u003cbr\u003eadding or removing specific elements, then an implementation defect causes the\u003cbr\u003e\u0027DEFAULT\u0027 list to lose its \u0027tuple\u0027 structure, and all server-supported groups\u003cbr\u003ewere treated as a single sufficiently secure \u0027tuple\u0027, with the server not\u003cbr\u003esending a Hello Retry Request (HRR) even when a group in a more preferred tuple\u003cbr\u003ewas mutually supported.\u003cbr\u003e\u003cbr\u003eAs a result, the client and server might fail to negotiate a mutually supported\u003cbr\u003epost-quantum key agreement group, such as \u0027X25519MLKEM768\u0027, if the client\u0027s\u003cbr\u003econfiguration results in only \u0027classical\u0027 groups (such as \u0027X25519\u0027 being the\u003cbr\u003eonly ones in the client\u0027s initial keyshare prediction).\u003cbr\u003e\u003cbr\u003eOpenSSL 3.5 and later support a new syntax for selecting the most preferred TLS\u003cbr\u003e1.3 key agreement group on TLS servers. The old syntax had a single \u0027flat\u0027\u003cbr\u003elist of groups, and treated all the supported groups as sufficiently secure.\u003cbr\u003eIf any of the keyshares predicted by the client were supported by the server\u003cbr\u003ethe most preferred among these was selected, even if other groups supported by\u003cbr\u003ethe client, but not included in the list of predicted keyshares would have been\u003cbr\u003emore preferred, if included.\u003cbr\u003e\u003cbr\u003eThe new syntax partitions the groups into distinct \u0027tuples\u0027 of roughly\u003cbr\u003eequivalent security. Within each tuple the most preferred group included among\u003cbr\u003ethe client\u0027s predicted keyshares is chosen, but if the client supports a group\u003cbr\u003efrom a more preferred tuple, but did not predict any corresponding keyshares,\u003cbr\u003ethe server will ask the client to retry the ClientHello (by issuing a Hello\u003cbr\u003eRetry Request or HRR) with the most preferred mutually supported group.\u003cbr\u003e\u003cbr\u003eThe above works as expected when the server\u0027s configuration uses the built-in\u003cbr\u003edefault group list, or explicitly defines its own list by directly defining the\u003cbr\u003evarious desired groups and group \u0027tuples\u0027.\u003cbr\u003e\u003cbr\u003eNo OpenSSL FIPS modules are affected by this issue, the code in question lies\u003cbr\u003eoutside the FIPS boundary.\u003cbr\u003e\u003cbr\u003eOpenSSL 3.6 and 3.5 are vulnerable to this issue.\u003cbr\u003e\u003cbr\u003eOpenSSL 3.6 users should upgrade to OpenSSL 3.6.2 once it is released.\u003cbr\u003eOpenSSL 3.5 users should upgrade to OpenSSL 3.5.6 once it is released.\u003cbr\u003e\u003cbr\u003eOpenSSL 3.4, 3.3, 3.0, 1.0.2 and 1.1.1 are not affected by this issue."
}
],
"value": "Issue summary: An OpenSSL TLS 1.3 server may fail to negotiate the expected\npreferred key exchange group when its key exchange group configuration includes\nthe default by using the \u0027DEFAULT\u0027 keyword.\n\nImpact summary: A less preferred key exchange may be used even when a more\npreferred group is supported by both client and server, if the group\nwas not included among the client\u0027s initial predicated keyshares.\nThis will sometimes be the case with the new hybrid post-quantum groups,\nif the client chooses to defer their use until specifically requested by\nthe server.\n\nIf an OpenSSL TLS 1.3 server\u0027s configuration uses the \u0027DEFAULT\u0027 keyword to\ninterpolate the built-in default group list into its own configuration, perhaps\nadding or removing specific elements, then an implementation defect causes the\n\u0027DEFAULT\u0027 list to lose its \u0027tuple\u0027 structure, and all server-supported groups\nwere treated as a single sufficiently secure \u0027tuple\u0027, with the server not\nsending a Hello Retry Request (HRR) even when a group in a more preferred tuple\nwas mutually supported.\n\nAs a result, the client and server might fail to negotiate a mutually supported\npost-quantum key agreement group, such as \u0027X25519MLKEM768\u0027, if the client\u0027s\nconfiguration results in only \u0027classical\u0027 groups (such as \u0027X25519\u0027 being the\nonly ones in the client\u0027s initial keyshare prediction).\n\nOpenSSL 3.5 and later support a new syntax for selecting the most preferred TLS\n1.3 key agreement group on TLS servers. The old syntax had a single \u0027flat\u0027\nlist of groups, and treated all the supported groups as sufficiently secure.\nIf any of the keyshares predicted by the client were supported by the server\nthe most preferred among these was selected, even if other groups supported by\nthe client, but not included in the list of predicted keyshares would have been\nmore preferred, if included.\n\nThe new syntax partitions the groups into distinct \u0027tuples\u0027 of roughly\nequivalent security. Within each tuple the most preferred group included among\nthe client\u0027s predicted keyshares is chosen, but if the client supports a group\nfrom a more preferred tuple, but did not predict any corresponding keyshares,\nthe server will ask the client to retry the ClientHello (by issuing a Hello\nRetry Request or HRR) with the most preferred mutually supported group.\n\nThe above works as expected when the server\u0027s configuration uses the built-in\ndefault group list, or explicitly defines its own list by directly defining the\nvarious desired groups and group \u0027tuples\u0027.\n\nNo OpenSSL FIPS modules are affected by this issue, the code in question lies\noutside the FIPS boundary.\n\nOpenSSL 3.6 and 3.5 are vulnerable to this issue.\n\nOpenSSL 3.6 users should upgrade to OpenSSL 3.6.2 once it is released.\nOpenSSL 3.5 users should upgrade to OpenSSL 3.5.6 once it is released.\n\nOpenSSL 3.4, 3.3, 3.0, 1.0.2 and 1.1.1 are not affected by this issue."
}
],
"metrics": [
{
"format": "other",
"other": {
"content": {
"text": "Low"
},
"type": "https://openssl-library.org/policies/general/security-policy/"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-757",
"description": "CWE-757 Selection of Less-Secure Algorithm During Negotiation (\u0027Algorithm Downgrade\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T13:23:00.376Z",
"orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"shortName": "openssl"
},
"references": [
{
"name": "OpenSSL Advisory",
"tags": [
"vendor-advisory"
],
"url": "https://openssl-library.org/news/secadv/20260313.txt"
},
{
"name": "3.6.2 git commit",
"tags": [
"patch"
],
"url": "https://github.com/openssl/openssl/commit/2157c9d81f7b0bd7dfa25b960e928ec28e8dd63f"
},
{
"name": "3.5.6 git commit",
"tags": [
"patch"
],
"url": "https://github.com/openssl/openssl/commit/85977e013f32ceb96aa034c0e741adddc1a05e34"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OpenSSL TLS 1.3 server may choose unexpected key agreement group",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"assignerShortName": "openssl",
"cveId": "CVE-2026-2673",
"datePublished": "2026-03-13T13:23:00.376Z",
"dateReserved": "2026-02-18T09:41:04.155Z",
"dateUpdated": "2026-05-18T19:23:37.078Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40941 (GCVE-0-2025-40941)
Vulnerability from nvd – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:13
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected devices exposes server information in its responses.
This could allow an attacker with network access to gain useful information, increasing the likelihood of targeted attacks.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40941",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:12:55.142801Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:13:03.138Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected devices exposes server information in its responses.\r\nThis could allow an attacker with network access to gain useful information, increasing the likelihood of targeted attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:40.075Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40941",
"datePublished": "2025-12-09T10:44:40.075Z",
"dateReserved": "2025-04-16T09:06:15.879Z",
"dateUpdated": "2025-12-09T15:13:03.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40940 (GCVE-0-2025-40940)
Vulnerability from nvd – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:18
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application exhibits inconsistent SNMP behavior, such as unexpected service availability and unreliable configuration handling across protocol versions. This could allow an attacker to access sensitive data, potentially leading to a breach of confidentiality.
Severity
4.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40940",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:18:26.594280Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:18:54.927Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected application exhibits inconsistent SNMP behavior, such as unexpected service availability and unreliable configuration handling across protocol versions. This could allow an attacker to access sensitive data, potentially leading to a breach of confidentiality."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:39.009Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40940",
"datePublished": "2025-12-09T10:44:39.009Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T15:18:54.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40939 (GCVE-0-2025-40939)
Vulnerability from nvd – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:26
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device contains a USB port which allows unauthenticated connections. This could allow an attacker with physical access to the device to trigger reboot that could cause denial of service condition.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40939",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:21:01.915353Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:26:06.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected device contains a USB port which allows unauthenticated connections. This could allow an attacker with physical access to the device to trigger reboot that could cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:37.963Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40939",
"datePublished": "2025-12-09T10:44:37.963Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T15:26:06.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40938 (GCVE-0-2025-40938)
Vulnerability from nvd – Published: 2025-12-09 10:44 – Updated: 2025-12-09 16:15
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device stores sensitive information in the firmware. This could allow an attacker to access and misuse this information, potentially impacting the device’s confidentiality, integrity, and availability.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T16:15:08.106090Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T16:15:21.579Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected device stores sensitive information in the firmware. This could allow an attacker to access and misuse this information, potentially impacting the device\u2019s confidentiality, integrity, and availability."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:36.883Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40938",
"datePublished": "2025-12-09T10:44:36.883Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T16:15:21.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40937 (GCVE-0-2025-40937)
Vulnerability from nvd – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:33
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments.
This could allow an authenticated attacker to execute arbitrary code with limited privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40937",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:30:10.583434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:33:38.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments.\r\nThis could allow an authenticated attacker to execute arbitrary code with limited privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:35.795Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40937",
"datePublished": "2025-12-09T10:44:35.795Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T15:33:38.168Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-38502 (GCVE-0-2025-38502)
Vulnerability from nvd – Published: 2025-08-16 09:34 – Updated: 2026-05-12 12:05
VLAI
Title
bpf: Fix oob access in cgroup local storage
Summary
In the Linux kernel, the following vulnerability has been resolved:
bpf: Fix oob access in cgroup local storage
Lonial reported that an out-of-bounds access in cgroup local storage
can be crafted via tail calls. Given two programs each utilizing a
cgroup local storage with a different value size, and one program
doing a tail call into the other. The verifier will validate each of
the indivial programs just fine. However, in the runtime context
the bpf_cg_run_ctx holds an bpf_prog_array_item which contains the
BPF program as well as any cgroup local storage flavor the program
uses. Helpers such as bpf_get_local_storage() pick this up from the
runtime context:
ctx = container_of(current->bpf_ctx, struct bpf_cg_run_ctx, run_ctx);
storage = ctx->prog_item->cgroup_storage[stype];
if (stype == BPF_CGROUP_STORAGE_SHARED)
ptr = &READ_ONCE(storage->buf)->data[0];
else
ptr = this_cpu_ptr(storage->percpu_buf);
For the second program which was called from the originally attached
one, this means bpf_get_local_storage() will pick up the former
program's map, not its own. With mismatching sizes, this can result
in an unintended out-of-bounds access.
To fix this issue, we need to extend bpf_map_owner with an array of
storage_cookie[] to match on i) the exact maps from the original
program if the second program was using bpf_get_local_storage(), or
ii) allow the tail call combination if the second program was not
using any of the cgroup local storage maps.
Severity
No CVSS data available.
Assigner
References
8 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Linux | Linux |
Affected:
7d9c3427894fe70d1347b4820476bf37736d2ff0 , < c1c74584b9b4043c52e41fec415226e582d266a3
(git)
Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 66da7cee78590259b400e51a70622ccd41da7bb2 (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 7acfa07c585e3d7a64654d38f0a5c762877d0b9b (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 41688d1fc5d163a6c2c0e95c0419e2cb31a44648 (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 19341d5c59e8c7e8528e40f8663e99d67810473c (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < abad3d0bad72a52137e0c350c59542d75ae4f513 (git) |
|
| Linux | Linux |
Affected:
5.9
Unaffected: 0 , < 5.9 (semver) Unaffected: 5.15.192 , ≤ 5.15.* (semver) Unaffected: 6.1.151 , ≤ 6.1.* (semver) Unaffected: 6.6.105 , ≤ 6.6.* (semver) Unaffected: 6.12.46 , ≤ 6.12.* (semver) Unaffected: 6.16.1 , ≤ 6.16.* (semver) Unaffected: 6.17 , ≤ * (original_commit_for_fix) |
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-03T17:39:11.518Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://lists.debian.org/debian-lts-announce/2025/10/msg00008.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T12:05:13.025Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Linux",
"programFiles": [
"include/linux/bpf.h",
"kernel/bpf/core.c"
],
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"vendor": "Linux",
"versions": [
{
"lessThan": "c1c74584b9b4043c52e41fec415226e582d266a3",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "66da7cee78590259b400e51a70622ccd41da7bb2",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "7acfa07c585e3d7a64654d38f0a5c762877d0b9b",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "41688d1fc5d163a6c2c0e95c0419e2cb31a44648",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "19341d5c59e8c7e8528e40f8663e99d67810473c",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "abad3d0bad72a52137e0c350c59542d75ae4f513",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
}
]
},
{
"defaultStatus": "affected",
"product": "Linux",
"programFiles": [
"include/linux/bpf.h",
"kernel/bpf/core.c"
],
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"vendor": "Linux",
"versions": [
{
"status": "affected",
"version": "5.9"
},
{
"lessThan": "5.9",
"status": "unaffected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "5.15.*",
"status": "unaffected",
"version": "5.15.192",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.1.*",
"status": "unaffected",
"version": "6.1.151",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.6.*",
"status": "unaffected",
"version": "6.6.105",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.12.*",
"status": "unaffected",
"version": "6.12.46",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.16.*",
"status": "unaffected",
"version": "6.16.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "*",
"status": "unaffected",
"version": "6.17",
"versionType": "original_commit_for_fix"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "5.15.192",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.1.151",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.6.105",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.12.46",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.16.1",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.17",
"versionStartIncluding": "5.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In the Linux kernel, the following vulnerability has been resolved:\n\nbpf: Fix oob access in cgroup local storage\n\nLonial reported that an out-of-bounds access in cgroup local storage\ncan be crafted via tail calls. Given two programs each utilizing a\ncgroup local storage with a different value size, and one program\ndoing a tail call into the other. The verifier will validate each of\nthe indivial programs just fine. However, in the runtime context\nthe bpf_cg_run_ctx holds an bpf_prog_array_item which contains the\nBPF program as well as any cgroup local storage flavor the program\nuses. Helpers such as bpf_get_local_storage() pick this up from the\nruntime context:\n\n ctx = container_of(current-\u003ebpf_ctx, struct bpf_cg_run_ctx, run_ctx);\n storage = ctx-\u003eprog_item-\u003ecgroup_storage[stype];\n\n if (stype == BPF_CGROUP_STORAGE_SHARED)\n ptr = \u0026READ_ONCE(storage-\u003ebuf)-\u003edata[0];\n else\n ptr = this_cpu_ptr(storage-\u003epercpu_buf);\n\nFor the second program which was called from the originally attached\none, this means bpf_get_local_storage() will pick up the former\nprogram\u0027s map, not its own. With mismatching sizes, this can result\nin an unintended out-of-bounds access.\n\nTo fix this issue, we need to extend bpf_map_owner with an array of\nstorage_cookie[] to match on i) the exact maps from the original\nprogram if the second program was using bpf_get_local_storage(), or\nii) allow the tail call combination if the second program was not\nusing any of the cgroup local storage maps."
}
],
"providerMetadata": {
"dateUpdated": "2026-05-11T21:29:15.758Z",
"orgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"shortName": "Linux"
},
"references": [
{
"url": "https://git.kernel.org/stable/c/c1c74584b9b4043c52e41fec415226e582d266a3"
},
{
"url": "https://git.kernel.org/stable/c/66da7cee78590259b400e51a70622ccd41da7bb2"
},
{
"url": "https://git.kernel.org/stable/c/7acfa07c585e3d7a64654d38f0a5c762877d0b9b"
},
{
"url": "https://git.kernel.org/stable/c/41688d1fc5d163a6c2c0e95c0419e2cb31a44648"
},
{
"url": "https://git.kernel.org/stable/c/19341d5c59e8c7e8528e40f8663e99d67810473c"
},
{
"url": "https://git.kernel.org/stable/c/abad3d0bad72a52137e0c350c59542d75ae4f513"
}
],
"title": "bpf: Fix oob access in cgroup local storage",
"x_generator": {
"engine": "bippy-1.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"assignerShortName": "Linux",
"cveId": "CVE-2025-38502",
"datePublished": "2025-08-16T09:34:25.135Z",
"dateReserved": "2025-04-16T04:51:24.022Z",
"dateUpdated": "2026-05-12T12:05:13.025Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40593 (GCVE-0-2025-40593)
Vulnerability from nvd – Published: 2025-07-08 10:34 – Updated: 2025-07-08 16:11
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40593",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:25:56.958907Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T16:11:43.633Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T10:34:51.157Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626991.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40593",
"datePublished": "2025-07-08T10:34:51.157Z",
"dateReserved": "2025-04-16T08:20:17.034Z",
"dateUpdated": "2025-07-08T16:11:43.633Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32742 (GCVE-0-2024-32742)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1326 - Missing Immutable Root of Trust in Hardware
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
|
| siemens | simatic_cn_4100 |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32742",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:43:18.352073Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:34.134Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.285Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1326",
"description": "CWE-1326: Missing Immutable Root of Trust in Hardware",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:36.881Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32742",
"datePublished": "2024-05-14T10:02:49.388Z",
"dateReserved": "2024-04-17T12:35:40.942Z",
"dateUpdated": "2024-08-02T02:20:35.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32741 (GCVE-0-2024-32741)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-259 - Use of Hard-coded Password
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
|
| siemens | simatic_cn_4100 |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32741",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:45:45.741161Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:22.017Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:34.965Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259: Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:35.739Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32741",
"datePublished": "2024-05-14T10:02:48.224Z",
"dateReserved": "2024-04-17T12:35:40.942Z",
"dateUpdated": "2024-08-02T02:20:34.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32740 (GCVE-0-2024-32740)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device
locally or over the network.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
|
| siemens | simatic_cn_4100 |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32740",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:46:23.213597Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:09.679Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.369Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device\r\nlocally or over the network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:34.549Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32740",
"datePublished": "2024-05-14T10:02:47.049Z",
"dateReserved": "2024-04-17T12:35:40.941Z",
"dateUpdated": "2024-08-02T02:20:35.369Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-49621 (GCVE-0-2023-49621)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2025-06-17 20:39
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
All versions < V2.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:01:25.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-49621",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-23T05:01:44.085293Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:39:17.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.7). The \"intermediate installation\" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:11.770Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-49621",
"datePublished": "2024-01-09T10:00:11.770Z",
"dateReserved": "2023-11-28T10:01:06.679Z",
"dateUpdated": "2025-06-17T20:39:17.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-49252 (GCVE-0-2023-49252)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2025-06-17 20:39
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The affected application allows IP configuration change without authentication to the device. This could allow an attacker to cause denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
All versions < V2.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:53:44.925Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-49252",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-23T05:01:43.410220Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:39:17.291Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.7). The affected application allows IP configuration change without authentication to the device. This could allow an attacker to cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:10.226Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-49252",
"datePublished": "2024-01-09T10:00:10.226Z",
"dateReserved": "2023-11-24T11:41:23.260Z",
"dateUpdated": "2025-06-17T20:39:17.291Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-49251 (GCVE-0-2023-49251)
Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2024-11-14 15:13
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
All versions < V2.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:53:44.991Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-49251",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-23T05:01:42.712707Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-14T15:13:08.903Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.7). The \"intermediate installation\" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639: Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:08.834Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-49251",
"datePublished": "2024-01-09T10:00:08.834Z",
"dateReserved": "2023-11-24T11:41:23.260Z",
"dateUpdated": "2024-11-14T15:13:08.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-22925 (GCVE-0-2026-22925)
Vulnerability from cvelistv5 – Published: 2026-05-12 08:20 – Updated: 2026-05-12 13:27
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application is susceptible to resource exhaustion when subjected to high volume of TCP SYN packets
This could allow an attacker to render the service unavailable and cause denial-of-service conditions by overwhelming system resources.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22925",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-12T13:27:07.360737Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T13:27:38.628Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V5.0). The affected application is susceptible to resource exhaustion when subjected to high volume of TCP SYN packets\r\nThis could allow an attacker to render the service unavailable and cause denial-of-service conditions by overwhelming system resources."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:20:56.636Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-22925",
"datePublished": "2026-05-12T08:20:56.636Z",
"dateReserved": "2026-01-13T15:21:45.769Z",
"dateUpdated": "2026-05-12T13:27:38.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22924 (GCVE-0-2026-22924)
Vulnerability from cvelistv5 – Published: 2026-05-12 08:20 – Updated: 2026-05-13 09:51
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application does not properly restrict unauthenticated connections and is susceptible to resource exhaustion conditions.
This could allow an attacker to disrupt normal operations or perform unauthorized actions, potentially impacting system availability and integrity.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22924",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T01:40:31.029305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T09:51:24.816Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V5.0). The affected application does not properly restrict unauthenticated connections and is susceptible to resource exhaustion conditions.\r\nThis could allow an attacker to disrupt normal operations or perform unauthorized actions, potentially impacting system availability and integrity."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:20:55.135Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-22924",
"datePublished": "2026-05-12T08:20:55.135Z",
"dateReserved": "2026-01-13T15:21:45.768Z",
"dateUpdated": "2026-05-13T09:51:24.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2673 (GCVE-0-2026-2673)
Vulnerability from cvelistv5 – Published: 2026-03-13 13:23 – Updated: 2026-05-18 19:23
VLAI
Title
OpenSSL TLS 1.3 server may choose unexpected key agreement group
Summary
Issue summary: An OpenSSL TLS 1.3 server may fail to negotiate the expected
preferred key exchange group when its key exchange group configuration includes
the default by using the 'DEFAULT' keyword.
Impact summary: A less preferred key exchange may be used even when a more
preferred group is supported by both client and server, if the group
was not included among the client's initial predicated keyshares.
This will sometimes be the case with the new hybrid post-quantum groups,
if the client chooses to defer their use until specifically requested by
the server.
If an OpenSSL TLS 1.3 server's configuration uses the 'DEFAULT' keyword to
interpolate the built-in default group list into its own configuration, perhaps
adding or removing specific elements, then an implementation defect causes the
'DEFAULT' list to lose its 'tuple' structure, and all server-supported groups
were treated as a single sufficiently secure 'tuple', with the server not
sending a Hello Retry Request (HRR) even when a group in a more preferred tuple
was mutually supported.
As a result, the client and server might fail to negotiate a mutually supported
post-quantum key agreement group, such as 'X25519MLKEM768', if the client's
configuration results in only 'classical' groups (such as 'X25519' being the
only ones in the client's initial keyshare prediction).
OpenSSL 3.5 and later support a new syntax for selecting the most preferred TLS
1.3 key agreement group on TLS servers. The old syntax had a single 'flat'
list of groups, and treated all the supported groups as sufficiently secure.
If any of the keyshares predicted by the client were supported by the server
the most preferred among these was selected, even if other groups supported by
the client, but not included in the list of predicted keyshares would have been
more preferred, if included.
The new syntax partitions the groups into distinct 'tuples' of roughly
equivalent security. Within each tuple the most preferred group included among
the client's predicted keyshares is chosen, but if the client supports a group
from a more preferred tuple, but did not predict any corresponding keyshares,
the server will ask the client to retry the ClientHello (by issuing a Hello
Retry Request or HRR) with the most preferred mutually supported group.
The above works as expected when the server's configuration uses the built-in
default group list, or explicitly defines its own list by directly defining the
various desired groups and group 'tuples'.
No OpenSSL FIPS modules are affected by this issue, the code in question lies
outside the FIPS boundary.
OpenSSL 3.6 and 3.5 are vulnerable to this issue.
OpenSSL 3.6 users should upgrade to OpenSSL 3.6.2 once it is released.
OpenSSL 3.5 users should upgrade to OpenSSL 3.5.6 once it is released.
OpenSSL 3.4, 3.3, 3.0, 1.0.2 and 1.1.1 are not affected by this issue.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-757 - Selection of Less-Secure Algorithm During Negotiation ('Algorithm Downgrade')
Assigner
References
5 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| OpenSSL | OpenSSL |
Affected:
3.6.0 , < 3.6.2
(semver)
Affected: 3.5.0 , < 3.5.6 (semver) |
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
Date Public
2026-03-13 14:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-03-13T15:15:21.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/03/13/3"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2026-2673",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-17T17:17:17.444679Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-18T19:23:37.078Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T12:08:46.771Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OpenSSL",
"vendor": "OpenSSL",
"versions": [
{
"lessThan": "3.6.2",
"status": "affected",
"version": "3.6.0",
"versionType": "semver"
},
{
"lessThan": "3.5.6",
"status": "affected",
"version": "3.5.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Viktor Dukhovni"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Viktor Dukhovni"
}
],
"datePublic": "2026-03-13T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Issue summary: An OpenSSL TLS 1.3 server may fail to negotiate the expected\u003cbr\u003epreferred key exchange group when its key exchange group configuration includes\u003cbr\u003ethe default by using the \u0027DEFAULT\u0027 keyword.\u003cbr\u003e\u003cbr\u003eImpact summary: A less preferred key exchange may be used even when a more\u003cbr\u003epreferred group is supported by both client and server, if the group\u003cbr\u003ewas not included among the client\u0027s initial predicated keyshares.\u003cbr\u003eThis will sometimes be the case with the new hybrid post-quantum groups,\u003cbr\u003eif the client chooses to defer their use until specifically requested by\u003cbr\u003ethe server.\u003cbr\u003e\u003cbr\u003eIf an OpenSSL TLS 1.3 server\u0027s configuration uses the \u0027DEFAULT\u0027 keyword to\u003cbr\u003einterpolate the built-in default group list into its own configuration, perhaps\u003cbr\u003eadding or removing specific elements, then an implementation defect causes the\u003cbr\u003e\u0027DEFAULT\u0027 list to lose its \u0027tuple\u0027 structure, and all server-supported groups\u003cbr\u003ewere treated as a single sufficiently secure \u0027tuple\u0027, with the server not\u003cbr\u003esending a Hello Retry Request (HRR) even when a group in a more preferred tuple\u003cbr\u003ewas mutually supported.\u003cbr\u003e\u003cbr\u003eAs a result, the client and server might fail to negotiate a mutually supported\u003cbr\u003epost-quantum key agreement group, such as \u0027X25519MLKEM768\u0027, if the client\u0027s\u003cbr\u003econfiguration results in only \u0027classical\u0027 groups (such as \u0027X25519\u0027 being the\u003cbr\u003eonly ones in the client\u0027s initial keyshare prediction).\u003cbr\u003e\u003cbr\u003eOpenSSL 3.5 and later support a new syntax for selecting the most preferred TLS\u003cbr\u003e1.3 key agreement group on TLS servers. The old syntax had a single \u0027flat\u0027\u003cbr\u003elist of groups, and treated all the supported groups as sufficiently secure.\u003cbr\u003eIf any of the keyshares predicted by the client were supported by the server\u003cbr\u003ethe most preferred among these was selected, even if other groups supported by\u003cbr\u003ethe client, but not included in the list of predicted keyshares would have been\u003cbr\u003emore preferred, if included.\u003cbr\u003e\u003cbr\u003eThe new syntax partitions the groups into distinct \u0027tuples\u0027 of roughly\u003cbr\u003eequivalent security. Within each tuple the most preferred group included among\u003cbr\u003ethe client\u0027s predicted keyshares is chosen, but if the client supports a group\u003cbr\u003efrom a more preferred tuple, but did not predict any corresponding keyshares,\u003cbr\u003ethe server will ask the client to retry the ClientHello (by issuing a Hello\u003cbr\u003eRetry Request or HRR) with the most preferred mutually supported group.\u003cbr\u003e\u003cbr\u003eThe above works as expected when the server\u0027s configuration uses the built-in\u003cbr\u003edefault group list, or explicitly defines its own list by directly defining the\u003cbr\u003evarious desired groups and group \u0027tuples\u0027.\u003cbr\u003e\u003cbr\u003eNo OpenSSL FIPS modules are affected by this issue, the code in question lies\u003cbr\u003eoutside the FIPS boundary.\u003cbr\u003e\u003cbr\u003eOpenSSL 3.6 and 3.5 are vulnerable to this issue.\u003cbr\u003e\u003cbr\u003eOpenSSL 3.6 users should upgrade to OpenSSL 3.6.2 once it is released.\u003cbr\u003eOpenSSL 3.5 users should upgrade to OpenSSL 3.5.6 once it is released.\u003cbr\u003e\u003cbr\u003eOpenSSL 3.4, 3.3, 3.0, 1.0.2 and 1.1.1 are not affected by this issue."
}
],
"value": "Issue summary: An OpenSSL TLS 1.3 server may fail to negotiate the expected\npreferred key exchange group when its key exchange group configuration includes\nthe default by using the \u0027DEFAULT\u0027 keyword.\n\nImpact summary: A less preferred key exchange may be used even when a more\npreferred group is supported by both client and server, if the group\nwas not included among the client\u0027s initial predicated keyshares.\nThis will sometimes be the case with the new hybrid post-quantum groups,\nif the client chooses to defer their use until specifically requested by\nthe server.\n\nIf an OpenSSL TLS 1.3 server\u0027s configuration uses the \u0027DEFAULT\u0027 keyword to\ninterpolate the built-in default group list into its own configuration, perhaps\nadding or removing specific elements, then an implementation defect causes the\n\u0027DEFAULT\u0027 list to lose its \u0027tuple\u0027 structure, and all server-supported groups\nwere treated as a single sufficiently secure \u0027tuple\u0027, with the server not\nsending a Hello Retry Request (HRR) even when a group in a more preferred tuple\nwas mutually supported.\n\nAs a result, the client and server might fail to negotiate a mutually supported\npost-quantum key agreement group, such as \u0027X25519MLKEM768\u0027, if the client\u0027s\nconfiguration results in only \u0027classical\u0027 groups (such as \u0027X25519\u0027 being the\nonly ones in the client\u0027s initial keyshare prediction).\n\nOpenSSL 3.5 and later support a new syntax for selecting the most preferred TLS\n1.3 key agreement group on TLS servers. The old syntax had a single \u0027flat\u0027\nlist of groups, and treated all the supported groups as sufficiently secure.\nIf any of the keyshares predicted by the client were supported by the server\nthe most preferred among these was selected, even if other groups supported by\nthe client, but not included in the list of predicted keyshares would have been\nmore preferred, if included.\n\nThe new syntax partitions the groups into distinct \u0027tuples\u0027 of roughly\nequivalent security. Within each tuple the most preferred group included among\nthe client\u0027s predicted keyshares is chosen, but if the client supports a group\nfrom a more preferred tuple, but did not predict any corresponding keyshares,\nthe server will ask the client to retry the ClientHello (by issuing a Hello\nRetry Request or HRR) with the most preferred mutually supported group.\n\nThe above works as expected when the server\u0027s configuration uses the built-in\ndefault group list, or explicitly defines its own list by directly defining the\nvarious desired groups and group \u0027tuples\u0027.\n\nNo OpenSSL FIPS modules are affected by this issue, the code in question lies\noutside the FIPS boundary.\n\nOpenSSL 3.6 and 3.5 are vulnerable to this issue.\n\nOpenSSL 3.6 users should upgrade to OpenSSL 3.6.2 once it is released.\nOpenSSL 3.5 users should upgrade to OpenSSL 3.5.6 once it is released.\n\nOpenSSL 3.4, 3.3, 3.0, 1.0.2 and 1.1.1 are not affected by this issue."
}
],
"metrics": [
{
"format": "other",
"other": {
"content": {
"text": "Low"
},
"type": "https://openssl-library.org/policies/general/security-policy/"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-757",
"description": "CWE-757 Selection of Less-Secure Algorithm During Negotiation (\u0027Algorithm Downgrade\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T13:23:00.376Z",
"orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"shortName": "openssl"
},
"references": [
{
"name": "OpenSSL Advisory",
"tags": [
"vendor-advisory"
],
"url": "https://openssl-library.org/news/secadv/20260313.txt"
},
{
"name": "3.6.2 git commit",
"tags": [
"patch"
],
"url": "https://github.com/openssl/openssl/commit/2157c9d81f7b0bd7dfa25b960e928ec28e8dd63f"
},
{
"name": "3.5.6 git commit",
"tags": [
"patch"
],
"url": "https://github.com/openssl/openssl/commit/85977e013f32ceb96aa034c0e741adddc1a05e34"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OpenSSL TLS 1.3 server may choose unexpected key agreement group",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"assignerShortName": "openssl",
"cveId": "CVE-2026-2673",
"datePublished": "2026-03-13T13:23:00.376Z",
"dateReserved": "2026-02-18T09:41:04.155Z",
"dateUpdated": "2026-05-18T19:23:37.078Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40941 (GCVE-0-2025-40941)
Vulnerability from cvelistv5 – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:13
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected devices exposes server information in its responses.
This could allow an attacker with network access to gain useful information, increasing the likelihood of targeted attacks.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40941",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:12:55.142801Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:13:03.138Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected devices exposes server information in its responses.\r\nThis could allow an attacker with network access to gain useful information, increasing the likelihood of targeted attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:40.075Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40941",
"datePublished": "2025-12-09T10:44:40.075Z",
"dateReserved": "2025-04-16T09:06:15.879Z",
"dateUpdated": "2025-12-09T15:13:03.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40940 (GCVE-0-2025-40940)
Vulnerability from cvelistv5 – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:18
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application exhibits inconsistent SNMP behavior, such as unexpected service availability and unreliable configuration handling across protocol versions. This could allow an attacker to access sensitive data, potentially leading to a breach of confidentiality.
Severity
4.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40940",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:18:26.594280Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:18:54.927Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected application exhibits inconsistent SNMP behavior, such as unexpected service availability and unreliable configuration handling across protocol versions. This could allow an attacker to access sensitive data, potentially leading to a breach of confidentiality."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:39.009Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40940",
"datePublished": "2025-12-09T10:44:39.009Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T15:18:54.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40939 (GCVE-0-2025-40939)
Vulnerability from cvelistv5 – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:26
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device contains a USB port which allows unauthenticated connections. This could allow an attacker with physical access to the device to trigger reboot that could cause denial of service condition.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40939",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:21:01.915353Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:26:06.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected device contains a USB port which allows unauthenticated connections. This could allow an attacker with physical access to the device to trigger reboot that could cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:37.963Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40939",
"datePublished": "2025-12-09T10:44:37.963Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T15:26:06.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40938 (GCVE-0-2025-40938)
Vulnerability from cvelistv5 – Published: 2025-12-09 10:44 – Updated: 2025-12-09 16:15
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device stores sensitive information in the firmware. This could allow an attacker to access and misuse this information, potentially impacting the device’s confidentiality, integrity, and availability.
Severity
8.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T16:15:08.106090Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T16:15:21.579Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected device stores sensitive information in the firmware. This could allow an attacker to access and misuse this information, potentially impacting the device\u2019s confidentiality, integrity, and availability."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:36.883Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40938",
"datePublished": "2025-12-09T10:44:36.883Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T16:15:21.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40937 (GCVE-0-2025-40937)
Vulnerability from cvelistv5 – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:33
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments.
This could allow an authenticated attacker to execute arbitrary code with limited privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40937",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-09T15:30:10.583434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T15:33:38.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments.\r\nThis could allow an authenticated attacker to execute arbitrary code with limited privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T10:44:35.795Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-416652.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40937",
"datePublished": "2025-12-09T10:44:35.795Z",
"dateReserved": "2025-04-16T09:06:15.878Z",
"dateUpdated": "2025-12-09T15:33:38.168Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-38502 (GCVE-0-2025-38502)
Vulnerability from cvelistv5 – Published: 2025-08-16 09:34 – Updated: 2026-05-12 12:05
VLAI
Title
bpf: Fix oob access in cgroup local storage
Summary
In the Linux kernel, the following vulnerability has been resolved:
bpf: Fix oob access in cgroup local storage
Lonial reported that an out-of-bounds access in cgroup local storage
can be crafted via tail calls. Given two programs each utilizing a
cgroup local storage with a different value size, and one program
doing a tail call into the other. The verifier will validate each of
the indivial programs just fine. However, in the runtime context
the bpf_cg_run_ctx holds an bpf_prog_array_item which contains the
BPF program as well as any cgroup local storage flavor the program
uses. Helpers such as bpf_get_local_storage() pick this up from the
runtime context:
ctx = container_of(current->bpf_ctx, struct bpf_cg_run_ctx, run_ctx);
storage = ctx->prog_item->cgroup_storage[stype];
if (stype == BPF_CGROUP_STORAGE_SHARED)
ptr = &READ_ONCE(storage->buf)->data[0];
else
ptr = this_cpu_ptr(storage->percpu_buf);
For the second program which was called from the originally attached
one, this means bpf_get_local_storage() will pick up the former
program's map, not its own. With mismatching sizes, this can result
in an unintended out-of-bounds access.
To fix this issue, we need to extend bpf_map_owner with an array of
storage_cookie[] to match on i) the exact maps from the original
program if the second program was using bpf_get_local_storage(), or
ii) allow the tail call combination if the second program was not
using any of the cgroup local storage maps.
Severity
No CVSS data available.
Assigner
References
8 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Linux | Linux |
Affected:
7d9c3427894fe70d1347b4820476bf37736d2ff0 , < c1c74584b9b4043c52e41fec415226e582d266a3
(git)
Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 66da7cee78590259b400e51a70622ccd41da7bb2 (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 7acfa07c585e3d7a64654d38f0a5c762877d0b9b (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 41688d1fc5d163a6c2c0e95c0419e2cb31a44648 (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < 19341d5c59e8c7e8528e40f8663e99d67810473c (git) Affected: 7d9c3427894fe70d1347b4820476bf37736d2ff0 , < abad3d0bad72a52137e0c350c59542d75ae4f513 (git) |
|
| Linux | Linux |
Affected:
5.9
Unaffected: 0 , < 5.9 (semver) Unaffected: 5.15.192 , ≤ 5.15.* (semver) Unaffected: 6.1.151 , ≤ 6.1.* (semver) Unaffected: 6.6.105 , ≤ 6.6.* (semver) Unaffected: 6.12.46 , ≤ 6.12.* (semver) Unaffected: 6.16.1 , ≤ 6.16.* (semver) Unaffected: 6.17 , ≤ * (original_commit_for_fix) |
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V5.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-03T17:39:11.518Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://lists.debian.org/debian-lts-announce/2025/10/msg00008.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T12:05:13.025Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-032379.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Linux",
"programFiles": [
"include/linux/bpf.h",
"kernel/bpf/core.c"
],
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"vendor": "Linux",
"versions": [
{
"lessThan": "c1c74584b9b4043c52e41fec415226e582d266a3",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "66da7cee78590259b400e51a70622ccd41da7bb2",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "7acfa07c585e3d7a64654d38f0a5c762877d0b9b",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "41688d1fc5d163a6c2c0e95c0419e2cb31a44648",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "19341d5c59e8c7e8528e40f8663e99d67810473c",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
},
{
"lessThan": "abad3d0bad72a52137e0c350c59542d75ae4f513",
"status": "affected",
"version": "7d9c3427894fe70d1347b4820476bf37736d2ff0",
"versionType": "git"
}
]
},
{
"defaultStatus": "affected",
"product": "Linux",
"programFiles": [
"include/linux/bpf.h",
"kernel/bpf/core.c"
],
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"vendor": "Linux",
"versions": [
{
"status": "affected",
"version": "5.9"
},
{
"lessThan": "5.9",
"status": "unaffected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "5.15.*",
"status": "unaffected",
"version": "5.15.192",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.1.*",
"status": "unaffected",
"version": "6.1.151",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.6.*",
"status": "unaffected",
"version": "6.6.105",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.12.*",
"status": "unaffected",
"version": "6.12.46",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.16.*",
"status": "unaffected",
"version": "6.16.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "*",
"status": "unaffected",
"version": "6.17",
"versionType": "original_commit_for_fix"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "5.15.192",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.1.151",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.6.105",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.12.46",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.16.1",
"versionStartIncluding": "5.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.17",
"versionStartIncluding": "5.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In the Linux kernel, the following vulnerability has been resolved:\n\nbpf: Fix oob access in cgroup local storage\n\nLonial reported that an out-of-bounds access in cgroup local storage\ncan be crafted via tail calls. Given two programs each utilizing a\ncgroup local storage with a different value size, and one program\ndoing a tail call into the other. The verifier will validate each of\nthe indivial programs just fine. However, in the runtime context\nthe bpf_cg_run_ctx holds an bpf_prog_array_item which contains the\nBPF program as well as any cgroup local storage flavor the program\nuses. Helpers such as bpf_get_local_storage() pick this up from the\nruntime context:\n\n ctx = container_of(current-\u003ebpf_ctx, struct bpf_cg_run_ctx, run_ctx);\n storage = ctx-\u003eprog_item-\u003ecgroup_storage[stype];\n\n if (stype == BPF_CGROUP_STORAGE_SHARED)\n ptr = \u0026READ_ONCE(storage-\u003ebuf)-\u003edata[0];\n else\n ptr = this_cpu_ptr(storage-\u003epercpu_buf);\n\nFor the second program which was called from the originally attached\none, this means bpf_get_local_storage() will pick up the former\nprogram\u0027s map, not its own. With mismatching sizes, this can result\nin an unintended out-of-bounds access.\n\nTo fix this issue, we need to extend bpf_map_owner with an array of\nstorage_cookie[] to match on i) the exact maps from the original\nprogram if the second program was using bpf_get_local_storage(), or\nii) allow the tail call combination if the second program was not\nusing any of the cgroup local storage maps."
}
],
"providerMetadata": {
"dateUpdated": "2026-05-11T21:29:15.758Z",
"orgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"shortName": "Linux"
},
"references": [
{
"url": "https://git.kernel.org/stable/c/c1c74584b9b4043c52e41fec415226e582d266a3"
},
{
"url": "https://git.kernel.org/stable/c/66da7cee78590259b400e51a70622ccd41da7bb2"
},
{
"url": "https://git.kernel.org/stable/c/7acfa07c585e3d7a64654d38f0a5c762877d0b9b"
},
{
"url": "https://git.kernel.org/stable/c/41688d1fc5d163a6c2c0e95c0419e2cb31a44648"
},
{
"url": "https://git.kernel.org/stable/c/19341d5c59e8c7e8528e40f8663e99d67810473c"
},
{
"url": "https://git.kernel.org/stable/c/abad3d0bad72a52137e0c350c59542d75ae4f513"
}
],
"title": "bpf: Fix oob access in cgroup local storage",
"x_generator": {
"engine": "bippy-1.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"assignerShortName": "Linux",
"cveId": "CVE-2025-38502",
"datePublished": "2025-08-16T09:34:25.135Z",
"dateReserved": "2025-04-16T04:51:24.022Z",
"dateUpdated": "2026-05-12T12:05:13.025Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40593 (GCVE-0-2025-40593)
Vulnerability from cvelistv5 – Published: 2025-07-08 10:34 – Updated: 2025-07-08 16:11
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V4.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40593",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:25:56.958907Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T16:11:43.633Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T10:34:51.157Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626991.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40593",
"datePublished": "2025-07-08T10:34:51.157Z",
"dateReserved": "2025-04-16T08:20:17.034Z",
"dateUpdated": "2025-07-08T16:11:43.633Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32742 (GCVE-0-2024-32742)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1326 - Missing Immutable Root of Trust in Hardware
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
|
| siemens | simatic_cn_4100 |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32742",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:43:18.352073Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:34.134Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.285Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1326",
"description": "CWE-1326: Missing Immutable Root of Trust in Hardware",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:36.881Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32742",
"datePublished": "2024-05-14T10:02:49.388Z",
"dateReserved": "2024-04-17T12:35:40.942Z",
"dateUpdated": "2024-08-02T02:20:35.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32741 (GCVE-0-2024-32741)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-259 - Use of Hard-coded Password
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
|
| siemens | simatic_cn_4100 |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32741",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:45:45.741161Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:22.017Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:34.965Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259: Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:35.739Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32741",
"datePublished": "2024-05-14T10:02:48.224Z",
"dateReserved": "2024-04-17T12:35:40.942Z",
"dateUpdated": "2024-08-02T02:20:34.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32740 (GCVE-0-2024-32740)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device
locally or over the network.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
|
| siemens | simatic_cn_4100 |
Affected:
0 , < 3.0
(custom)
cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32740",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:46:23.213597Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:09.679Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.369Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device\r\nlocally or over the network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:34.549Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32740",
"datePublished": "2024-05-14T10:02:47.049Z",
"dateReserved": "2024-04-17T12:35:40.941Z",
"dateUpdated": "2024-08-02T02:20:35.369Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-49621 (GCVE-0-2023-49621)
Vulnerability from cvelistv5 – Published: 2024-01-09 10:00 – Updated: 2025-06-17 20:39
VLAI
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
All versions < V2.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:01:25.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-49621",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-23T05:01:44.085293Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T20:39:17.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V2.7). The \"intermediate installation\" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:11.770Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-777015.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-49621",
"datePublished": "2024-01-09T10:00:11.770Z",
"dateReserved": "2023-11-28T10:01:06.679Z",
"dateUpdated": "2025-06-17T20:39:17.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}