Search
Find a vulnerability
Search criteria
7061 vulnerabilities by siemens
CVE-2026-67367 (GCVE-0-2026-67367)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:56
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions < V3.1.13), SIMOVE Fleetmanager V3.2 (All versions < V3.2.4), SIMOVE Fleetmanager V3.3 (All versions < V3.3.2), SIMOVE Fleetmanager V4.0 (All versions < V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions < V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets.
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:56 UTC
CWE
- CWE-23 - Relative Path Traversal
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMOVE Fleetmanager V3.1 |
Affected:
0 , < V3.1.13
(custom)
|
|
| Siemens | SIMOVE Fleetmanager V3.2 |
Affected:
0 , < V3.2.4
(custom)
|
|
| Siemens | SIMOVE Fleetmanager V3.3 |
Affected:
0 , < V3.3.2
(custom)
|
|
| Siemens | SIMOVE Fleetmanager V4.0 |
Affected:
0 , < V4.0.1
(custom)
|
|
| Siemens | SIPLANT V1.7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLANT V2.2 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLANT V3.0 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLANT V3.1 |
Affected:
0 , < V3.1.4
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-67367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:56:26.529587Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:56:42.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V3.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V3.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V3.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V1.7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V2.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V3.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions \u003c V3.1.13), SIMOVE Fleetmanager V3.2 (All versions \u003c V3.2.4), SIMOVE Fleetmanager V3.3 (All versions \u003c V3.3.2), SIMOVE Fleetmanager V4.0 (All versions \u003c V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions \u003c V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23: Relative Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:36.311Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517424.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-67367",
"datePublished": "2026-09-08T08:11:36.311Z",
"dateReserved": "2026-07-29T14:51:27.000Z",
"dateUpdated": "2026-09-09T15:56:42.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62654 (GCVE-0-2026-62654)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:24 UTC
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62654",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:24:21.127677Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:24:28.328Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:35.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62654",
"datePublished": "2026-09-08T08:11:35.239Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T12:24:28.328Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62653 (GCVE-0-2026-62653)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 08:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device.
Severity
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:34.180Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62653",
"datePublished": "2026-09-08T08:11:34.180Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T08:11:34.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62652 (GCVE-0-2026-62652)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-10 18:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device's firmware, facilitating the identification of further vulnerabilities.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 18:18 UTC
CWE
- CWE-215 - Insertion of Sensitive Information Into Debugging Code
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62652",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T18:18:16.274605Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T18:18:25.117Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device\u0027s firmware, facilitating the identification of further vulnerabilities."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-215",
"description": "CWE-215: Insertion of Sensitive Information Into Debugging Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:33.091Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62652",
"datePublished": "2026-09-08T08:11:33.091Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-10T18:18:25.117Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62650 (GCVE-0-2026-62650)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:23 UTC
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62650",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:23:11.725916Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:24:41.707Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:32.013Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62650",
"datePublished": "2026-09-08T08:11:32.013Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T12:24:41.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62649 (GCVE-0-2026-62649)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:50 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62649",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:50:39.262220Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:50:52.432Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:30.935Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62649",
"datePublished": "2026-09-08T08:11:30.935Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-09T15:50:52.432Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62648 (GCVE-0-2026-62648)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:24 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62648",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:24:43.278434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:24:51.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:29.868Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62648",
"datePublished": "2026-09-08T08:11:29.868Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T12:24:51.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62647 (GCVE-0-2026-62647)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 08:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device.
Severity
7.4 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:24.801Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62647",
"datePublished": "2026-09-08T08:11:24.801Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T08:11:24.801Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62646 (GCVE-0-2026-62646)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-10 18:19
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication.
Severity
7.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 18:19 UTC
CWE
- CWE-331 - Insufficient Entropy
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62646",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T18:19:17.570941Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T18:19:25.743Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-331",
"description": "CWE-331: Insufficient Entropy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:23.739Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62646",
"datePublished": "2026-09-08T08:11:23.739Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-10T18:19:25.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62645 (GCVE-0-2026-62645)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:26
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:26 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62645",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:26:09.683968Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:26:29.371Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:22.667Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62645",
"datePublished": "2026-09-08T08:11:22.667Z",
"dateReserved": "2026-07-14T16:24:23.429Z",
"dateUpdated": "2026-09-08T12:26:29.371Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-58113 (GCVE-0-2026-58113)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).
This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:25 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0013
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0010
(custom)
|
|
| Siemens | Teamcenter V2512 |
Affected:
0 , < V2512.2607
(custom)
|
|
| Siemens | Teamcenter V2606 |
Affected:
0 , < V2606.2607
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-58113",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:25:24.743406Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:25:34.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2606",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2412 (All versions \u003c V2412.0013), Teamcenter V2506 (All versions \u003c V2506.0010), Teamcenter V2512 (All versions \u003c V2512.2607), Teamcenter V2606 (All versions \u003c V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).\r\nThis could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim\u0027s Teamcenter session."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:21.609Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-157465.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-58113",
"datePublished": "2026-09-08T08:11:21.609Z",
"dateReserved": "2026-06-29T11:49:12.097Z",
"dateUpdated": "2026-09-09T15:25:34.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50093 (GCVE-0-2026-50093)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:56
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions < V3.0.12.2173), Siveillance Control Pro V4.0 (All versions < V4.0.9.2178), Siveillance Control V3.0 (All versions < V3.0.22.2177), Siveillance Control V4.0 (All versions < V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:55 UTC
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Siveillance Control Pro V3.0 |
Affected:
0 , < V3.0.12.2173
(custom)
|
|
| Siemens | Siveillance Control Pro V4.0 |
Affected:
0 , < V4.0.9.2178
(custom)
|
|
| Siemens | Siveillance Control V3.0 |
Affected:
0 , < V3.0.22.2177
(custom)
|
|
| Siemens | Siveillance Control V4.0 |
Affected:
0 , < V4.0.11.2177
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50093",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:55:57.191112Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:56:05.522Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.12.2173",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.9.2178",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.22.2177",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.11.2177",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions \u003c V3.0.12.2173), Siveillance Control Pro V4.0 (All versions \u003c V4.0.9.2178), Siveillance Control V3.0 (All versions \u003c V3.0.22.2177), Siveillance Control V4.0 (All versions \u003c V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.9,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:18.207Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-254516.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-50093",
"datePublished": "2026-09-08T08:11:18.207Z",
"dateReserved": "2026-06-03T14:44:36.213Z",
"dateUpdated": "2026-09-08T12:56:05.522Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-34223 (GCVE-0-2026-34223)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-08 08:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo CC ClickOnce Client V6 (All versions), Desigo CC ClickOnce Client V7 (All versions), Desigo CC family V8 (All versions), Desigo CC family V9 (All versions), Desigo CC Flex Client V6 (All versions), Desigo CC Flex Client V7 (All versions), Desigo CC Installed Client V6 (All versions), Desigo CC Installed Client V7 (All versions). The affected application is vulnerable to Client Code Execution (CCE) due to insufficient input validation when handling scripts embedded within user-defined graphics documents. Specifically, when the script within a graphics document is designed or modified by an attacker to include malicious commands. When a user opens a compromised graphics document, the embedded script is executed on the client application instance, allowing an attacker to write arbitrary files to the client's operating system. Successful exploitation requires an attacker to craft a malicious graphics document and entice a user with sufficient privileges to display it. This could lead to compromise of the client operating system and potential lateral movement within the organization.
Severity
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo CC ClickOnce Client V6 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC ClickOnce Client V7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V8 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V9 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Flex Client V6 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Flex Client V7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Installed Client V6 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Installed Client V7 |
Affected:
0 , < *
(custom)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Desigo CC ClickOnce Client V6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC ClickOnce Client V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Flex Client V6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Flex Client V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Installed Client V6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Installed Client V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo CC ClickOnce Client V6 (All versions), Desigo CC ClickOnce Client V7 (All versions), Desigo CC family V8 (All versions), Desigo CC family V9 (All versions), Desigo CC Flex Client V6 (All versions), Desigo CC Flex Client V7 (All versions), Desigo CC Installed Client V6 (All versions), Desigo CC Installed Client V7 (All versions). The affected application is vulnerable to Client Code Execution (CCE) due to insufficient input validation when handling scripts embedded within user-defined graphics documents. Specifically, when the script within a graphics document is designed or modified by an attacker to include malicious commands. When a user opens a compromised graphics document, the embedded script is executed on the client application instance, allowing an attacker to write arbitrary files to the client\u0027s operating system. Successful exploitation requires an attacker to craft a malicious graphics document and entice a user with sufficient privileges to display it. This could lead to compromise of the client operating system and potential lateral movement within the organization."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:17.139Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-330084.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-34223",
"datePublished": "2026-09-08T08:11:17.139Z",
"dateReserved": "2026-03-26T16:03:07.476Z",
"dateUpdated": "2026-09-08T08:11:17.139Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80465 (GCVE-0-2026-80465)
Vulnerability from nvd – Published: 2026-09-03 11:25 – Updated: 2026-09-03 18:15
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions < V4.2.3), Mendix SAML (Mendix 11 compatible) (All versions < V4.2.3), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.27). Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-03 18:15 UTC
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Mendix SAML (Mendix 10 compatible) |
Affected:
0 , < V4.2.3
(custom)
|
|
| Siemens | Mendix SAML (Mendix 11 compatible) |
Affected:
0 , < V4.2.3
(custom)
|
|
| Siemens | Mendix SAML (Mendix 9.24 compatible) |
Affected:
0 , < V3.6.27
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80465",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-03T18:15:27.716259Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-03T18:15:38.743Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Mendix SAML (Mendix 10 compatible)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix SAML (Mendix 11 compatible)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix SAML (Mendix 9.24 compatible)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.6.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions \u003c V4.2.3), Mendix SAML (Mendix 11 compatible) (All versions \u003c V4.2.3), Mendix SAML (Mendix 9.24 compatible) (All versions \u003c V3.6.27). Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-03T11:25:10.771Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-887643.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-80465",
"datePublished": "2026-09-03T11:25:10.771Z",
"dateReserved": "2026-08-26T12:49:28.232Z",
"dateUpdated": "2026-09-03T18:15:38.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-66155 (GCVE-0-2026-66155)
Vulnerability from nvd – Published: 2026-08-27 11:56 – Updated: 2026-08-27 14:56
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Element maps-ng V47 (All versions < V47.12.3), Element maps-ng V48 (All versions < V48.11.3), Element maps-ng V49 (All versions < V49.16.1). The si-map component does not properly neutralize user-controllable input of the points property that is used to render the tooltip label of map pins.
This could allow an attacker to craft a malicious URL that, when loaded by a victim and the map pin is hovered over, executes arbitrary script code within the victim's browser session.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-27 14:52 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Element maps-ng V47 |
Affected:
0 , < V47.12.3
(custom)
|
|
| Siemens | Element maps-ng V48 |
Affected:
0 , < V48.11.3
(custom)
|
|
| Siemens | Element maps-ng V49 |
Affected:
0 , < V49.16.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-66155",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-27T14:52:52.987225Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-27T14:56:34.021Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Element maps-ng V47",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V47.12.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Element maps-ng V48",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V48.11.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Element maps-ng V49",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V49.16.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Element maps-ng V47 (All versions \u003c V47.12.3), Element maps-ng V48 (All versions \u003c V48.11.3), Element maps-ng V49 (All versions \u003c V49.16.1). The si-map component does not properly neutralize user-controllable input of the points property that is used to render the tooltip label of map pins.\r\nThis could allow an attacker to craft a malicious URL that, when loaded by a victim and the map pin is hovered over, executes arbitrary script code within the victim\u0027s browser session."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-27T11:56:48.418Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-682041.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-66155",
"datePublished": "2026-08-27T11:56:48.418Z",
"dateReserved": "2026-07-24T09:01:24.331Z",
"dateUpdated": "2026-08-27T14:56:34.021Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-67367 (GCVE-0-2026-67367)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:56
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions < V3.1.13), SIMOVE Fleetmanager V3.2 (All versions < V3.2.4), SIMOVE Fleetmanager V3.3 (All versions < V3.3.2), SIMOVE Fleetmanager V4.0 (All versions < V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions < V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets.
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:56 UTC
CWE
- CWE-23 - Relative Path Traversal
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMOVE Fleetmanager V3.1 |
Affected:
0 , < V3.1.13
(custom)
|
|
| Siemens | SIMOVE Fleetmanager V3.2 |
Affected:
0 , < V3.2.4
(custom)
|
|
| Siemens | SIMOVE Fleetmanager V3.3 |
Affected:
0 , < V3.3.2
(custom)
|
|
| Siemens | SIMOVE Fleetmanager V4.0 |
Affected:
0 , < V4.0.1
(custom)
|
|
| Siemens | SIPLANT V1.7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLANT V2.2 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLANT V3.0 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLANT V3.1 |
Affected:
0 , < V3.1.4
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-67367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:56:26.529587Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:56:42.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V3.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V3.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V3.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOVE Fleetmanager V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V1.7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V2.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLANT V3.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions \u003c V3.1.13), SIMOVE Fleetmanager V3.2 (All versions \u003c V3.2.4), SIMOVE Fleetmanager V3.3 (All versions \u003c V3.3.2), SIMOVE Fleetmanager V4.0 (All versions \u003c V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions \u003c V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23: Relative Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:36.311Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-517424.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-67367",
"datePublished": "2026-09-08T08:11:36.311Z",
"dateReserved": "2026-07-29T14:51:27.000Z",
"dateUpdated": "2026-09-09T15:56:42.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62654 (GCVE-0-2026-62654)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:24 UTC
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62654",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:24:21.127677Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:24:28.328Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:35.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62654",
"datePublished": "2026-09-08T08:11:35.239Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T12:24:28.328Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62653 (GCVE-0-2026-62653)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 08:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device.
Severity
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:34.180Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62653",
"datePublished": "2026-09-08T08:11:34.180Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T08:11:34.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62652 (GCVE-0-2026-62652)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-10 18:18
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device's firmware, facilitating the identification of further vulnerabilities.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 18:18 UTC
CWE
- CWE-215 - Insertion of Sensitive Information Into Debugging Code
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62652",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T18:18:16.274605Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T18:18:25.117Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device\u0027s firmware, facilitating the identification of further vulnerabilities."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-215",
"description": "CWE-215: Insertion of Sensitive Information Into Debugging Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:33.091Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62652",
"datePublished": "2026-09-08T08:11:33.091Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-10T18:18:25.117Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62650 (GCVE-0-2026-62650)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:23 UTC
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62650",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:23:11.725916Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:24:41.707Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:32.013Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62650",
"datePublished": "2026-09-08T08:11:32.013Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T12:24:41.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62649 (GCVE-0-2026-62649)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:50 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62649",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:50:39.262220Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:50:52.432Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:30.935Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62649",
"datePublished": "2026-09-08T08:11:30.935Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-09T15:50:52.432Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62648 (GCVE-0-2026-62648)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:24 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62648",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:24:43.278434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:24:51.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:29.868Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62648",
"datePublished": "2026-09-08T08:11:29.868Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T12:24:51.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62647 (GCVE-0-2026-62647)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 08:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device.
Severity
7.4 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:24.801Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62647",
"datePublished": "2026-09-08T08:11:24.801Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-08T08:11:24.801Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62646 (GCVE-0-2026-62646)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-10 18:19
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication.
Severity
7.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 18:19 UTC
CWE
- CWE-331 - Insufficient Entropy
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62646",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T18:19:17.570941Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T18:19:25.743Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-331",
"description": "CWE-331: Insufficient Entropy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:23.739Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62646",
"datePublished": "2026-09-08T08:11:23.739Z",
"dateReserved": "2026-07-14T16:24:23.430Z",
"dateUpdated": "2026-09-10T18:19:25.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-62645 (GCVE-0-2026-62645)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:26
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:26 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Reyrolle 7SR5 |
Affected:
0 , < V2.70
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-62645",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:26:09.683968Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:26:29.371Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Reyrolle 7SR5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:22.667Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-62645",
"datePublished": "2026-09-08T08:11:22.667Z",
"dateReserved": "2026-07-14T16:24:23.429Z",
"dateUpdated": "2026-09-08T12:26:29.371Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-58113 (GCVE-0-2026-58113)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).
This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:25 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0013
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0010
(custom)
|
|
| Siemens | Teamcenter V2512 |
Affected:
0 , < V2512.2607
(custom)
|
|
| Siemens | Teamcenter V2606 |
Affected:
0 , < V2606.2607
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-58113",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:25:24.743406Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:25:34.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2606",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2412 (All versions \u003c V2412.0013), Teamcenter V2506 (All versions \u003c V2506.0010), Teamcenter V2512 (All versions \u003c V2512.2607), Teamcenter V2606 (All versions \u003c V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).\r\nThis could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim\u0027s Teamcenter session."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:21.609Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-157465.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-58113",
"datePublished": "2026-09-08T08:11:21.609Z",
"dateReserved": "2026-06-29T11:49:12.097Z",
"dateUpdated": "2026-09-09T15:25:34.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50093 (GCVE-0-2026-50093)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:56
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions < V3.0.12.2173), Siveillance Control Pro V4.0 (All versions < V4.0.9.2178), Siveillance Control V3.0 (All versions < V3.0.22.2177), Siveillance Control V4.0 (All versions < V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 12:55 UTC
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Siveillance Control Pro V3.0 |
Affected:
0 , < V3.0.12.2173
(custom)
|
|
| Siemens | Siveillance Control Pro V4.0 |
Affected:
0 , < V4.0.9.2178
(custom)
|
|
| Siemens | Siveillance Control V3.0 |
Affected:
0 , < V3.0.22.2177
(custom)
|
|
| Siemens | Siveillance Control V4.0 |
Affected:
0 , < V4.0.11.2177
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50093",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:55:57.191112Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:56:05.522Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.12.2173",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control Pro V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.9.2178",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.22.2177",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Siveillance Control V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.11.2177",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions \u003c V3.0.12.2173), Siveillance Control Pro V4.0 (All versions \u003c V4.0.9.2178), Siveillance Control V3.0 (All versions \u003c V3.0.22.2177), Siveillance Control V4.0 (All versions \u003c V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.9,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:18.207Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-254516.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-50093",
"datePublished": "2026-09-08T08:11:18.207Z",
"dateReserved": "2026-06-03T14:44:36.213Z",
"dateUpdated": "2026-09-08T12:56:05.522Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-34223 (GCVE-0-2026-34223)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 08:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Desigo CC ClickOnce Client V6 (All versions), Desigo CC ClickOnce Client V7 (All versions), Desigo CC family V8 (All versions), Desigo CC family V9 (All versions), Desigo CC Flex Client V6 (All versions), Desigo CC Flex Client V7 (All versions), Desigo CC Installed Client V6 (All versions), Desigo CC Installed Client V7 (All versions). The affected application is vulnerable to Client Code Execution (CCE) due to insufficient input validation when handling scripts embedded within user-defined graphics documents. Specifically, when the script within a graphics document is designed or modified by an attacker to include malicious commands. When a user opens a compromised graphics document, the embedded script is executed on the client application instance, allowing an attacker to write arbitrary files to the client's operating system. Successful exploitation requires an attacker to craft a malicious graphics document and entice a user with sufficient privileges to display it. This could lead to compromise of the client operating system and potential lateral movement within the organization.
Severity
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Desigo CC ClickOnce Client V6 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC ClickOnce Client V7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V8 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V9 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Flex Client V6 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Flex Client V7 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Installed Client V6 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC Installed Client V7 |
Affected:
0 , < *
(custom)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Desigo CC ClickOnce Client V6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC ClickOnce Client V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Flex Client V6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Flex Client V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Installed Client V6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC Installed Client V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Desigo CC ClickOnce Client V6 (All versions), Desigo CC ClickOnce Client V7 (All versions), Desigo CC family V8 (All versions), Desigo CC family V9 (All versions), Desigo CC Flex Client V6 (All versions), Desigo CC Flex Client V7 (All versions), Desigo CC Installed Client V6 (All versions), Desigo CC Installed Client V7 (All versions). The affected application is vulnerable to Client Code Execution (CCE) due to insufficient input validation when handling scripts embedded within user-defined graphics documents. Specifically, when the script within a graphics document is designed or modified by an attacker to include malicious commands. When a user opens a compromised graphics document, the embedded script is executed on the client application instance, allowing an attacker to write arbitrary files to the client\u0027s operating system. Successful exploitation requires an attacker to craft a malicious graphics document and entice a user with sufficient privileges to display it. This could lead to compromise of the client operating system and potential lateral movement within the organization."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:17.139Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-330084.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-34223",
"datePublished": "2026-09-08T08:11:17.139Z",
"dateReserved": "2026-03-26T16:03:07.476Z",
"dateUpdated": "2026-09-08T08:11:17.139Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80465 (GCVE-0-2026-80465)
Vulnerability from cvelistv5 – Published: 2026-09-03 11:25 – Updated: 2026-09-03 18:15
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions < V4.2.3), Mendix SAML (Mendix 11 compatible) (All versions < V4.2.3), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.27). Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-03 18:15 UTC
CWE
- CWE-347 - Improper Verification of Cryptographic Signature
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Mendix SAML (Mendix 10 compatible) |
Affected:
0 , < V4.2.3
(custom)
|
|
| Siemens | Mendix SAML (Mendix 11 compatible) |
Affected:
0 , < V4.2.3
(custom)
|
|
| Siemens | Mendix SAML (Mendix 9.24 compatible) |
Affected:
0 , < V3.6.27
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80465",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-03T18:15:27.716259Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-03T18:15:38.743Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Mendix SAML (Mendix 10 compatible)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix SAML (Mendix 11 compatible)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix SAML (Mendix 9.24 compatible)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.6.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions \u003c V4.2.3), Mendix SAML (Mendix 11 compatible) (All versions \u003c V4.2.3), Mendix SAML (Mendix 9.24 compatible) (All versions \u003c V3.6.27). Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-03T11:25:10.771Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-887643.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-80465",
"datePublished": "2026-09-03T11:25:10.771Z",
"dateReserved": "2026-08-26T12:49:28.232Z",
"dateUpdated": "2026-09-03T18:15:38.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CERTFR-2026-AVI-1133
Vulnerability from certfr_avis - Published: 2026-09-08 - Updated: 2026-09-08
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire et une élévation de privilèges.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
Impacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC AX Runtime Core Linux VMWare Development toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | Desigo CC | Desigo CC toutes versions pour la vulnérabilité CVE-2026-34223 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC AX Runtime Core Linux Common Debian arm64 toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3UB57-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP700 Unified Basic (6AV2123-3GB32-0AW0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP700 Unified Comfort Panel (6AV2128-3GB06-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC IPC Industrial Edge Device OS (IED-OS) toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Unified Basic (6AV2123-3MB32-0AW0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1000 Unified Basic (6AV2123-3KB32-0AW0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC CN 4100 versions antérieures à 6.0 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP400 Unified Basic (6AV2123-3DB32-0AW0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC AX Runtime Core Linux Platform Container Common Debian Development toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3XB57-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC AX Runtime Core Linux Common Debian toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3QB57-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3MB57-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC S7-1500 TM MFP (6ES7558-1AA00-0AB0) toutes versions pour la vulnérabilité CVE-2026-31431 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0) versions antérieures à 21.0.2.1 | ||
| Siemens | SIMATIC | SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0) versions antérieures à 21.0.2.1 |
References
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC AX Runtime Core Linux VMWare Development toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-34223",
"product": {
"name": "Desigo CC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC AX Runtime Core Linux Common Debian arm64 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3UB57-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP700 Unified Basic (6AV2123-3GB32-0AW0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP700 Unified Comfort Panel (6AV2128-3GB06-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC Industrial Edge Device OS (IED-OS) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Unified Basic (6AV2123-3MB32-0AW0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1000 Unified Basic (6AV2123-3KB32-0AW0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CN 4100 versions ant\u00e9rieures \u00e0 6.0",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP400 Unified Basic (6AV2123-3DB32-0AW0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC AX Runtime Core Linux Platform Container Common Debian Development toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3XB57-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC AX Runtime Core Linux Common Debian toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3QB57-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3MB57-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 TM MFP (6ES7558-1AA00-0AB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2026-31431",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0) versions ant\u00e9rieures \u00e0 21.0.2.1",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2026-31431",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-31431"
},
{
"name": "CVE-2026-34223",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-34223"
}
],
"initial_release_date": "2026-09-08T00:00:00",
"last_revision_date": "2026-09-08T00:00:00",
"links": [],
"reference": "CERTFR-2026-AVI-1133",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2026-09-08T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Siemens. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire et une \u00e9l\u00e9vation de privil\u00e8ges.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": "2026-09-08",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-330084",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-330084.html"
},
{
"published_at": "2026-09-08",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-328642",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-328642.html"
}
]
}