Search

Find a vulnerability

Search criteria

    275 vulnerabilities

    CVE-2026-33390 (GCVE-0-2026-33390)

    Vulnerability from cvelistv5 – Published: 2026-07-09 07:23 – Updated: 2026-07-09 12:29
    VLAI
    Title
    Incorrect privilege assignment for Arc sensors in Guardian/CMC before 26.2.0
    Summary
    An Incorrect Privilege Assignment vulnerability was discovered in the synchronization functionality due to Arc sensors receiving CLI permissions. An authenticated user with limited privileges can push administrative CLI commands through the sync, altering the device configuration, and/or affecting its availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect privilege assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Nozomi Networks Guardian Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Date Public
    2026-07-07 07:00
    Credits
    This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-33390",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-09T12:28:05.263677Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-09T12:29:18.009Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-07-07T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Incorrect Privilege Assignment vulnerability was discovered in the synchronization functionality due to Arc sensors receiving CLI permissions. An authenticated user with limited privileges can push administrative CLI commands through the sync, altering the device configuration, and/or affecting its availability."
                }
              ],
              "value": "An Incorrect Privilege Assignment vulnerability was discovered in the synchronization functionality due to Arc sensors receiving CLI permissions. An authenticated user with limited privileges can push administrative CLI commands through the sync, altering the device configuration, and/or affecting its availability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266 Incorrect privilege assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-09T07:23:30.236Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:13-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.2.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.2.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Incorrect privilege assignment for Arc sensors in Guardian/CMC before 26.2.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all enabled sensors and disallow or delete untrusted ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all enabled sensors and disallow or delete untrusted ones."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-33390",
        "datePublished": "2026-07-09T07:23:30.236Z",
        "dateReserved": "2026-03-19T11:28:43.172Z",
        "dateUpdated": "2026-07-09T12:29:18.009Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-31985 (GCVE-0-2026-31985)

    Vulnerability from cvelistv5 – Published: 2026-07-09 07:23 – Updated: 2026-07-09 12:30
    VLAI
    Title
    Disabled and non-configurable TLS certificate validation in n2os-tui when connecting the Remote Collector to a Guardian or CMC, in Remote Collector before v26.2.0
    Summary
    When the upstream Guardian or CMC was configured in the Remote Collector via n2os-tui, the generated configuration disabled TLS certificate verification, and no option was provided to enable it. A malicious actor could perform a man-in-the-middle attack and intercept the communication between the Remote Collector and the Guardian or CMC. This could result in theft of the sync token, impersonation of the server, injection of spoofed data (such as false asset information or vulnerabilities) into the Guardian or CMC, or disruption of the data flow between the Remote Collector and the Guardian or CMC.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-671 - Lack of administrator control over security
    Assigner
    References
    Impacted products
    Vendor Product Version
    Nozomi Networks Remote Collector Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Date Public
    2026-07-07 07:00
    Credits
    This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-31985",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-09T12:30:51.118815Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-09T12:30:59.025Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Remote Collector",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:remote_collector:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-07-07T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "When the upstream Guardian or CMC was configured in the Remote Collector via n2os-tui, the generated configuration disabled TLS certificate verification, and no option was provided to enable it. A malicious actor could perform a man-in-the-middle attack and intercept the communication between the Remote Collector and the Guardian or CMC. This could result in theft of the sync token, impersonation of the server, injection of spoofed data (such as false asset information or vulnerabilities) into the Guardian or CMC, or disruption of the data flow between the Remote Collector and the Guardian or CMC."
                }
              ],
              "value": "When the upstream Guardian or CMC was configured in the Remote Collector via n2os-tui, the generated configuration disabled TLS certificate verification, and no option was provided to enable it. A malicious actor could perform a man-in-the-middle attack and intercept the communication between the Remote Collector and the Guardian or CMC. This could result in theft of the sync token, impersonation of the server, injection of spoofed data (such as false asset information or vulnerabilities) into the Guardian or CMC, or disruption of the data flow between the Remote Collector and the Guardian or CMC."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-94",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-94 Adversary in the Middle (AiTM)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-671",
                  "description": "CWE-671 Lack of administrator control over security",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-09T07:23:06.045Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:12-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.2.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.2.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Disabled and non-configurable TLS certificate validation in n2os-tui when connecting the Remote Collector to a Guardian or CMC, in Remote Collector before v26.2.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Manually edit the \"n2os.conf.user\" file in the Remote Collector and remove the \"!\" prefix from the upstream Guardian or CMC endpoint entry to enable TLS certificate verification."
                }
              ],
              "value": "Manually edit the \"n2os.conf.user\" file in the Remote Collector and remove the \"!\" prefix from the upstream Guardian or CMC endpoint entry to enable TLS certificate verification."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-31985",
        "datePublished": "2026-07-09T07:23:06.045Z",
        "dateReserved": "2026-03-10T16:14:03.266Z",
        "dateUpdated": "2026-07-09T12:30:59.025Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-31984 (GCVE-0-2026-31984)

    Vulnerability from cvelistv5 – Published: 2026-07-09 07:22 – Updated: 2026-07-09 12:40
    VLAI
    Title
    DoS through oversized audit log entries in Guardian/CMC before 26.2.0
    Summary
    A denial-of-service vulnerability caused by unbounded resource allocation was discovered in the audit logging functionality, due to a missing size limit on input recorded into audit entries. An unauthenticated attacker can submit requests containing excessively large input that is recorded into audit entries, possibly exhausting the available disk space and rendering the system inoperable.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-770 - Allocation of resources without limits or throttling
    Assigner
    References
    Impacted products
    Vendor Product Version
    Nozomi Networks Guardian Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Date Public
    2026-07-07 07:00
    Credits
    This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-31984",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-09T12:40:35.925650Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-09T12:40:47.448Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-07-07T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A denial-of-service vulnerability caused by unbounded resource allocation was discovered in the audit logging functionality, due to a missing size limit on input recorded into audit entries. An unauthenticated attacker can submit requests containing excessively large input that is recorded into audit entries, possibly exhausting the available disk space and rendering the system inoperable."
                }
              ],
              "value": "A denial-of-service vulnerability caused by unbounded resource allocation was discovered in the audit logging functionality, due to a missing size limit on input recorded into audit entries. An unauthenticated attacker can submit requests containing excessively large input that is recorded into audit entries, possibly exhausting the available disk space and rendering the system inoperable."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-130",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-130 Excessive Allocation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770 Allocation of resources without limits or throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-09T07:22:53.172Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:11-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.2.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.2.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "DoS through oversized audit log entries in Guardian/CMC before 26.2.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-31984",
        "datePublished": "2026-07-09T07:22:53.172Z",
        "dateReserved": "2026-03-10T16:14:03.266Z",
        "dateUpdated": "2026-07-09T12:40:47.448Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-31983 (GCVE-0-2026-31983)

    Vulnerability from cvelistv5 – Published: 2026-07-09 07:22 – Updated: 2026-07-09 12:41
    VLAI
    Title
    Missing authentication in SSH keys synchronization endpoint in Guardian/CMC before 26.2.0
    Summary
    A Missing Authentication vulnerability was discovered in the SSH keys synchronization endpoint. An unauthenticated attacker can send a request to the SSH keys synchronization endpoint and obtain the list of users that have uploaded their public SSH keys, their groups, and the uploaded public SSH keys.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Nozomi Networks Guardian Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Date Public
    2026-07-07 07:00
    Credits
    This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-31983",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-09T12:41:13.586614Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-09T12:41:20.941Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-07-07T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Missing Authentication vulnerability was discovered in the SSH keys synchronization endpoint. An unauthenticated attacker can send a request to the SSH keys synchronization endpoint and obtain the list of users that have uploaded their public SSH keys, their groups, and the uploaded public SSH keys."
                }
              ],
              "value": "A Missing Authentication vulnerability was discovered in the SSH keys synchronization endpoint. An unauthenticated attacker can send a request to the SSH keys synchronization endpoint and obtain the list of users that have uploaded their public SSH keys, their groups, and the uploaded public SSH keys."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-09T07:22:44.704Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:10-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.2.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.2.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Missing authentication in SSH keys synchronization endpoint in Guardian/CMC before 26.2.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-31983",
        "datePublished": "2026-07-09T07:22:44.704Z",
        "dateReserved": "2026-03-10T16:14:03.266Z",
        "dateUpdated": "2026-07-09T12:41:20.941Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-31982 (GCVE-0-2026-31982)

    Vulnerability from cvelistv5 – Published: 2026-07-09 07:22 – Updated: 2026-07-09 12:42
    VLAI
    Title
    Open Redirect in SAML Single Sign-On in Guardian/CMC before 26.2.0
    Summary
    An Open Redirect vulnerability was discovered in the SAML Single Sign-On functionality due to insufficient validation of a user-controlled redirection parameter. An unauthenticated attacker can craft a request to the SAML sign-in endpoint and poison the cached SAML redirection for other users who subsequently initiate SAML Single Sign-On, enabling phishing and credential-theft attacks, as well as disrupting SAML authentication for all affected users.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-601 - URL redirection to untrusted site ('open redirect')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Nozomi Networks Guardian Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Date Public
    2026-07-07 07:00
    Credits
    This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-31982",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-09T12:41:31.002741Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-09T12:42:40.823Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-07-07T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Open Redirect vulnerability was discovered in the SAML Single Sign-On functionality due to insufficient validation of a user-controlled redirection parameter. An unauthenticated attacker can craft a request to the SAML sign-in endpoint and poison the cached SAML redirection for other users who subsequently initiate SAML Single Sign-On, enabling phishing and credential-theft attacks, as well as disrupting SAML authentication for all affected users."
                }
              ],
              "value": "An Open Redirect vulnerability was discovered in the SAML Single Sign-On functionality due to insufficient validation of a user-controlled redirection parameter. An unauthenticated attacker can craft a request to the SAML sign-in endpoint and poison the cached SAML redirection for other users who subsequently initiate SAML Single Sign-On, enabling phishing and credential-theft attacks, as well as disrupting SAML authentication for all affected users."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-194",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-194 Fake the Source of Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:L/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-601",
                  "description": "CWE-601 URL redirection to untrusted site (\u0027open redirect\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-09T07:22:35.960Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:9-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.2.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.2.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Open Redirect in SAML Single Sign-On in Guardian/CMC before 26.2.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-31982",
        "datePublished": "2026-07-09T07:22:35.960Z",
        "dateReserved": "2026-03-10T16:14:03.266Z",
        "dateUpdated": "2026-07-09T12:42:40.823Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-31981 (GCVE-0-2026-31981)

    Vulnerability from cvelistv5 – Published: 2026-07-09 07:22 – Updated: 2026-07-09 12:43
    VLAI
    Title
    HTML injection in Diagram tab and Graph view in Guardian/CMC before 26.2.0
    Summary
    A Stored HTML Injection vulnerability was discovered in the Diagram tab and Graph view due to a shared input validation function being insufficiently restrictive. An authenticated user with administrative privileges can inject malicious HTML tags into N2OS configuration data through multiple input vectors. When a victim views the affected data in the Diagram tab and Graph view, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Nozomi Networks Guardian Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 26.2.0 (semver)
    Create a notification for this product.
    Date Public
    2026-07-07 07:00
    Credits
    This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-31981",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-09T12:43:12.336549Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-09T12:43:26.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.2.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-07-07T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Stored HTML Injection vulnerability was discovered in the Diagram tab and Graph view due to a shared input validation function being insufficiently restrictive. An authenticated user with administrative privileges can inject malicious HTML tags into N2OS configuration data through multiple input vectors. When a victim views the affected data in the Diagram tab and Graph view, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
                }
              ],
              "value": "A Stored HTML Injection vulnerability was discovered in the Diagram tab and Graph view due to a shared input validation function being insufficiently restrictive. An authenticated user with administrative privileges can inject malicious HTML tags into N2OS configuration data through multiple input vectors. When a victim views the affected data in the Diagram tab and Graph view, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-09T07:22:21.271Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:8-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.2.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.2.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "HTML injection in Diagram tab and Graph view in Guardian/CMC before 26.2.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all accounts with administrative access to it and delete unnecessary ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all accounts with administrative access to it and delete unnecessary ones."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-31981",
        "datePublished": "2026-07-09T07:22:21.271Z",
        "dateReserved": "2026-03-10T16:14:03.265Z",
        "dateUpdated": "2026-07-09T12:43:26.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-13199 (GCVE-0-2026-13199)

    Vulnerability from cvelistv5 – Published: 2026-07-07 08:36 – Updated: 2026-07-07 13:22
    VLAI
    Title
    Insufficient Entropy in Raspberry Pi 5 and Compute Module 5
    Summary
    EEPROM firmware on Raspberry Pi 5 and Compute Module 5 devices produced non-random KASLR and RNG seed values. This resulted in consistent kernel addresses across boots and devices, potentially making it easier to exploit other vulnerabilities. Additionally, the low-quality RNG seed may affect the quality of random numbers or delay booting while sufficient entropy is accumulated from other sources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Credits
    Gabriele Quagliarella at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "NONE",
                  "baseScore": 4,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-13199",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-07T13:21:12.730043Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-07T13:22:19.318Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "EEPROM firmware"
              ],
              "packageName": "rpi-eeprom",
              "packageURL": "pkg:deb/debian/rpi-eeprom",
              "platforms": [
                "Linux"
              ],
              "product": "Raspberry Pi 5 and Compute Module 5",
              "vendor": "Raspberry Pi",
              "versions": [
                {
                  "lessThan": "28.22-1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "apt"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Quagliarella at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EEPROM firmware on Raspberry Pi 5 and Compute Module 5 devices produced non-random KASLR and RNG seed values. This resulted in consistent kernel addresses across boots and devices, potentially making it easier to exploit other vulnerabilities. Additionally, the low-quality RNG seed may affect the quality of random numbers or delay booting while sufficient entropy is accumulated from other sources."
                }
              ],
              "value": "EEPROM firmware on Raspberry Pi 5 and Compute Module 5 devices produced non-random KASLR and RNG seed values. This resulted in consistent kernel addresses across boots and devices, potentially making it easier to exploit other vulnerabilities. Additionally, the low-quality RNG seed may affect the quality of random numbers or delay booting while sufficient entropy is accumulated from other sources."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-554",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-554 Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-331",
                  "description": "CWE-331: Insufficient Entropy",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-07T08:36:57.330Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://github.com/raspberrypi/rpi-eeprom/pull/841"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2026-13199"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eTo fix this issue, it is suggested to update the rpi-eeprom package to version 28.22-1 or later.\u003c/p\u003e"
                }
              ],
              "value": "To fix this issue, it is suggested to update the rpi-eeprom package to version 28.22-1 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Insufficient Entropy in Raspberry Pi 5 and Compute Module 5",
          "x_generator": {
            "engine": "Vulnogram 1.0.2; edited by Nozomi Networks Labs"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-13199",
        "datePublished": "2026-07-07T08:36:57.330Z",
        "dateReserved": "2026-06-24T13:50:43.732Z",
        "dateUpdated": "2026-07-07T13:22:19.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-57473 (GCVE-0-2026-57473)

    Vulnerability from cvelistv5 – Published: 2026-06-26 10:47 – Updated: 2026-06-26 12:01
    VLAI
    Summary
    A vulnerability exists in the netclient and factory services of Reolink Home Hub (versions prior to v3.3.0.456_26031911) due to the possibility of brute-force cracking the credentials. This issue could allow attackers on the same local network to intercept traffic between the Hub and associated cameras and compromise the credentials of connected cameras.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Reolink Home Hub Affected: 0 , < 3.3.0.456_26031911 (semver)
    Create a notification for this product.
    Credits
    Raffaele Bova at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-57473",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-26T12:01:38.503831Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-26T12:01:44.449Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Home Hub",
              "vendor": "Reolink",
              "versions": [
                {
                  "lessThan": "3.3.0.456_26031911",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Raffaele Bova at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA vulnerability exists in the netclient and factory services of Reolink Home Hub (versions prior to v3.3.0.456_26031911) due to the possibility of brute-force cracking the credentials. This issue could allow attackers on the same local network to intercept traffic between the Hub and associated cameras and compromise the credentials of connected cameras.\u003c/p\u003e"
                }
              ],
              "value": "A vulnerability exists in the netclient and factory services of Reolink Home Hub (versions prior to v3.3.0.456_26031911) due to the possibility of brute-force cracking the credentials. This issue could allow attackers on the same local network to intercept traffic between the Hub and associated cameras and compromise the credentials of connected cameras."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-49",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-49 Password Brute Forcing"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1391",
                  "description": "CWE-1391 Use of Weak Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-26T10:47:31.153Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2026-57473"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-57473",
        "datePublished": "2026-06-26T10:47:31.153Z",
        "dateReserved": "2026-06-24T13:49:50.681Z",
        "dateUpdated": "2026-06-26T12:01:44.449Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41281 (GCVE-0-2025-41281)

    Vulnerability from cvelistv5 – Published: 2026-05-29 11:00 – Updated: 2026-05-29 13:36
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:36:33.262949Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:36:44.165Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T11:00:16.558Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41281"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41281",
        "datePublished": "2026-05-29T11:00:16.558Z",
        "dateReserved": "2025-04-16T09:53:43.284Z",
        "dateUpdated": "2026-05-29T13:36:44.165Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41280 (GCVE-0-2025-41280)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:59 – Updated: 2026-05-29 13:37
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-23: Relative Path Traversal (Zip Slip) in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured and file compression is enabled.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-23 - Relative Path Traversal
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41280",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:37:05.745440Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:37:18.914Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-23: Relative Path Traversal (Zip Slip) in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured and file compression is enabled.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-23: Relative Path Traversal (Zip Slip) in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured and file compression is enabled."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23 Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:59:40.686Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41280"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41280",
        "datePublished": "2026-05-29T10:59:40.686Z",
        "dateReserved": "2025-04-16T09:53:43.284Z",
        "dateUpdated": "2026-05-29T13:37:18.914Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41279 (GCVE-0-2025-41279)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:59 – Updated: 2026-05-29 13:38
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 RX Host.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41279",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:38:20.763131Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:38:35.939Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 RX Host.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 RX Host."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:59:10.976Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41279"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41279",
        "datePublished": "2026-05-29T10:59:10.976Z",
        "dateReserved": "2025-04-16T09:53:43.283Z",
        "dateUpdated": "2026-05-29T13:38:35.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41278 (GCVE-0-2025-41278)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:58 – Updated: 2026-05-29 13:39
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-125: Out-of-bounds Read in Waterfall WF-500 RX Host in version 7.10.0.0 R2601141040 that allows attackers with access to the TX Host to execute code on the RX Host.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.10.0.0 R2601141040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41278",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:38:50.831959Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:39:01.031Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.10.0.0 R2601141040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-125: Out-of-bounds Read in Waterfall WF-500 RX Host in version 7.10.0.0 R2601141040 that allows attackers with access to the TX Host to execute code on the RX Host.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-125: Out-of-bounds Read in Waterfall WF-500 RX Host in version 7.10.0.0 R2601141040 that allows attackers with access to the TX Host to execute code on the RX Host."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-540",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-540 Overread Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:58:37.123Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41278"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41278",
        "datePublished": "2026-05-29T10:58:37.123Z",
        "dateReserved": "2025-04-16T09:53:43.283Z",
        "dateUpdated": "2026-05-29T13:39:01.031Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41277 (GCVE-0-2025-41277)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:57 – Updated: 2026-05-29 13:39
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41277",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:39:21.453113Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:39:31.000Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:57:59.758Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41277"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41277",
        "datePublished": "2026-05-29T10:57:59.758Z",
        "dateReserved": "2025-04-16T09:53:43.283Z",
        "dateUpdated": "2026-05-29T13:39:31.000Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41276 (GCVE-0-2025-41276)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:57 – Updated: 2026-05-29 13:40
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41276",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:39:47.086583Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:40:10.225Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:57:22.463Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41276"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41276",
        "datePublished": "2026-05-29T10:57:22.463Z",
        "dateReserved": "2025-04-16T09:53:43.283Z",
        "dateUpdated": "2026-05-29T13:40:10.225Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41275 (GCVE-0-2025-41275)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:56 – Updated: 2026-05-29 13:40
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41275",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:40:26.355034Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:40:36.071Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:56:28.855Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41275"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41275",
        "datePublished": "2026-05-29T10:56:28.855Z",
        "dateReserved": "2025-04-16T09:53:43.283Z",
        "dateUpdated": "2026-05-29T13:40:36.071Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41274 (GCVE-0-2025-41274)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:53 – Updated: 2026-05-29 13:37
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41274",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:37:44.938993Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:37:55.353Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:53:38.156Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41274"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41274",
        "datePublished": "2026-05-29T10:53:38.156Z",
        "dateReserved": "2025-04-16T09:53:41.254Z",
        "dateUpdated": "2026-05-29T13:37:55.353Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41273 (GCVE-0-2025-41273)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:53 – Updated: 2026-05-29 13:41
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-288: Authentication Bypass Using an Alternate Path or Channel in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to bypass authentication of the Console web application and perform actions as an authenticated user.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41273",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:41:47.583391Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:41:58.127Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-288: Authentication Bypass Using an Alternate Path or Channel in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to bypass authentication of the Console web application and perform actions as an authenticated user.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-288: Authentication Bypass Using an Alternate Path or Channel in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to bypass authentication of the Console web application and perform actions as an authenticated user."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:53:02.555Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41273"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41273",
        "datePublished": "2026-05-29T10:53:02.555Z",
        "dateReserved": "2025-04-16T09:53:41.254Z",
        "dateUpdated": "2026-05-29T13:41:58.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41272 (GCVE-0-2025-41272)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:52 – Updated: 2026-05-29 13:42
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41272",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:42:17.154302Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:42:26.930Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:52:21.010Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41272"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41272",
        "datePublished": "2026-05-29T10:52:21.010Z",
        "dateReserved": "2025-04-16T09:53:41.254Z",
        "dateUpdated": "2026-05-29T13:42:26.930Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41271 (GCVE-0-2025-41271)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:51 – Updated: 2026-05-29 13:42
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to read arbitrary files from the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-23 - Relative Path Traversal
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41271",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:42:42.503918Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:42:55.452Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to read arbitrary files from the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to read arbitrary files from the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23 Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:51:40.281Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41271"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41271",
        "datePublished": "2026-05-29T10:51:40.281Z",
        "dateReserved": "2025-04-16T09:53:41.254Z",
        "dateUpdated": "2026-05-29T13:42:55.452Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41270 (GCVE-0-2025-41270)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:51 – Updated: 2026-05-29 13:43
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41270",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:43:12.413811Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:43:25.732Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:51:03.402Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41270"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41270",
        "datePublished": "2026-05-29T10:51:03.402Z",
        "dateReserved": "2025-04-16T09:53:41.254Z",
        "dateUpdated": "2026-05-29T13:43:25.732Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41269 (GCVE-0-2025-41269)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:50 – Updated: 2026-05-29 13:41
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41269",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:40:54.419864Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:41:05.083Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:50:06.202Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41269"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41269",
        "datePublished": "2026-05-29T10:50:06.202Z",
        "dateReserved": "2025-04-16T09:53:41.254Z",
        "dateUpdated": "2026-05-29T13:41:05.083Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41268 (GCVE-0-2025-41268)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:49 – Updated: 2026-05-29 13:41
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Administration WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to delete arbitrary files on the Host machines.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-23 - Relative Path Traversal
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41268",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:41:21.762972Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:41:30.693Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Administration WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to delete arbitrary files on the Host machines.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Administration WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to delete arbitrary files on the Host machines."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23 Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:49:29.042Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41268"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41268",
        "datePublished": "2026-05-29T10:49:29.042Z",
        "dateReserved": "2025-04-16T09:53:41.253Z",
        "dateUpdated": "2026-05-29T13:41:30.693Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41267 (GCVE-0-2025-41267)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:48 – Updated: 2026-05-29 14:03
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41267",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:45:14.128243Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:03:35.502Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:48:51.842Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41267"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41267",
        "datePublished": "2026-05-29T10:48:51.842Z",
        "dateReserved": "2025-04-16T09:53:41.253Z",
        "dateUpdated": "2026-05-29T14:03:35.502Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41266 (GCVE-0-2025-41266)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:48 – Updated: 2026-05-29 14:33
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41266",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:03:45.550756Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:33:46.968Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:48:08.952Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41266"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41266",
        "datePublished": "2026-05-29T10:48:08.952Z",
        "dateReserved": "2025-04-16T09:53:41.253Z",
        "dateUpdated": "2026-05-29T14:33:46.968Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41265 (GCVE-0-2025-41265)

    Vulnerability from cvelistv5 – Published: 2026-05-29 10:41 – Updated: 2026-05-29 14:36
    VLAI
    Summary
    Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Waterfall WF-500 Affected: 0 , ≤ 7.9.1.0 R2502171040 (semver)
    Create a notification for this product.
    Credits
    Luca Borzacchiello at Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41265",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:36:00.476872Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:36:09.993Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WF-500",
              "vendor": "Waterfall",
              "versions": [
                {
                  "lessThanOrEqual": "7.9.1.0 R2502171040",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luca Borzacchiello at Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eNozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.\u003c/p\u003e"
                }
              ],
              "value": "Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-29T10:41:12.429Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-41265"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-41265",
        "datePublished": "2026-05-29T10:41:12.429Z",
        "dateReserved": "2025-04-16T09:53:41.253Z",
        "dateUpdated": "2026-05-29T14:36:09.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40904 (GCVE-0-2025-40904)

    Vulnerability from cvelistv5 – Published: 2026-05-19 13:23 – Updated: 2026-06-09 09:02
    VLAI
    Title
    HTML injection in Smart Polling in Guardian/CMC before 26.1.0
    Summary
    A Stored HTML Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can push malicious remote strategies containing HTML tags through the sync. When a victim views the affected remote strategy in the Smart Polling functionality, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    Impacted products
    Date Public
    2026-05-19 07:00
    Credits
    This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40904",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-19T13:56:22.113514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-19T13:56:35.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T09:02:28.168Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-827968.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-05-19T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Stored HTML Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can push malicious remote strategies containing HTML tags through the sync. When a victim views the affected remote strategy in the Smart Polling functionality, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
                }
              ],
              "value": "A Stored HTML Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can push malicious remote strategies containing HTML tags through the sync. When a victim views the affected remote strategy in the Smart Polling functionality, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-19T13:23:35.418Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:7-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.1.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.1.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "HTML injection in Smart Polling in Guardian/CMC before 26.1.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all enabled sensors and disallow or delete untrusted ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all enabled sensors and disallow or delete untrusted ones."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-40904",
        "datePublished": "2026-05-19T13:23:35.418Z",
        "dateReserved": "2025-04-16T09:04:35.923Z",
        "dateUpdated": "2026-06-09T09:02:28.168Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40903 (GCVE-0-2025-40903)

    Vulnerability from cvelistv5 – Published: 2026-05-19 13:22 – Updated: 2026-06-09 09:02
    VLAI
    Title
    HTML injection in Schedule Restore Archive in Guardian/CMC before 26.1.0
    Summary
    A Stored HTML Injection vulnerability was discovered in the Schedule Restore Archive functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious restore schedule containing HTML tags. When a victim views the affected schedule, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    Impacted products
    Date Public
    2026-05-19 07:00
    Credits
    This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40903",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-19T13:58:03.055058Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-19T13:58:34.152Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T09:02:27.052Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-827968.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-05-19T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Stored HTML Injection vulnerability was discovered in the Schedule Restore Archive functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious restore schedule containing HTML tags. When a victim views the affected schedule, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
                }
              ],
              "value": "A Stored HTML Injection vulnerability was discovered in the Schedule Restore Archive functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious restore schedule containing HTML tags. When a victim views the affected schedule, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-19T13:22:15.850Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:6-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.1.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.1.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "HTML injection in Schedule Restore Archive in Guardian/CMC before 26.1.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all accounts with administrative access to it and delete unnecessary ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all accounts with administrative access to it and delete unnecessary ones."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-40903",
        "datePublished": "2026-05-19T13:22:15.850Z",
        "dateReserved": "2025-04-16T09:04:35.923Z",
        "dateUpdated": "2026-06-09T09:02:27.052Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40902 (GCVE-0-2025-40902)

    Vulnerability from cvelistv5 – Published: 2026-05-19 13:21 – Updated: 2026-06-09 09:02
    VLAI
    Title
    HTML injection in Users in Guardian/CMC before 26.1.0
    Summary
    A Stored HTML Injection vulnerability was discovered in the Users functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can create a malicious user whose username contains HTML tags. When a victim attempts to delete a group containing the affected user, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    Impacted products
    Date Public
    2026-05-19 07:00
    Credits
    This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40902",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-19T14:04:00.937056Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-19T14:04:37.503Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T09:02:25.919Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-827968.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-05-19T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Stored HTML Injection vulnerability was discovered in the Users functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can create a malicious user whose username contains HTML tags. When a victim attempts to delete a group containing the affected user, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
                }
              ],
              "value": "A Stored HTML Injection vulnerability was discovered in the Users functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can create a malicious user whose username contains HTML tags. When a victim attempts to delete a group containing the affected user, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-19T13:21:02.668Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:5-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.1.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.1.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "HTML injection in Users in Guardian/CMC before 26.1.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all accounts with administrative access to it and delete unnecessary ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all accounts with administrative access to it and delete unnecessary ones."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review usernames of existing users.\u003cbr\u003e"
                }
              ],
              "value": "Review usernames of existing users."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-40902",
        "datePublished": "2026-05-19T13:21:02.668Z",
        "dateReserved": "2025-04-16T09:04:35.923Z",
        "dateUpdated": "2026-06-09T09:02:25.919Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40901 (GCVE-0-2025-40901)

    Vulnerability from cvelistv5 – Published: 2026-05-19 13:19 – Updated: 2026-06-09 09:02
    VLAI
    Title
    HTML injection in Credentials Manager in Guardian/CMC before 26.1.0
    Summary
    A Stored HTML Injection vulnerability was discovered in the Credentials Manager functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious identity containing HTML tags. When a victim attempts to delete the affected identity, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    Impacted products
    Date Public
    2026-05-19 07:00
    Credits
    This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-19T14:05:59.618937Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-19T14:07:41.971Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T09:02:24.771Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-827968.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-05-19T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Stored HTML Injection vulnerability was discovered in the Credentials Manager functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious identity containing HTML tags. When a victim attempts to delete the affected identity, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
                }
              ],
              "value": "A Stored HTML Injection vulnerability was discovered in the Credentials Manager functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious identity containing HTML tags. When a victim attempts to delete the affected identity, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-19T13:19:45.819Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:4-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.1.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.1.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "HTML injection in Credentials Manager in Guardian/CMC before 26.1.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all accounts with administrative access to it and delete unnecessary ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all accounts with administrative access to it and delete unnecessary ones."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review existing identities stored in the Credentials Manager.\u003cbr\u003e"
                }
              ],
              "value": "Review existing identities stored in the Credentials Manager."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-40901",
        "datePublished": "2026-05-19T13:19:45.819Z",
        "dateReserved": "2025-04-16T09:04:35.923Z",
        "dateUpdated": "2026-06-09T09:02:24.771Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40900 (GCVE-0-2025-40900)

    Vulnerability from cvelistv5 – Published: 2026-05-19 13:17 – Updated: 2026-06-09 09:02
    VLAI
    Title
    Angular template injection in Reports in Guardian/CMC before 26.1.0
    Summary
    An Angular template injection vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing an Angular template payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the Angular template executes in their browser context, allowing the attacker to modify application data, or disrupt application availability. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1336 - Improper neutralization of special elements used in a template engine
    Assigner
    Impacted products
    Date Public
    2026-05-19 07:00
    Credits
    This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40900",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-19T14:09:06.088185Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-19T14:09:56.116Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-09T09:02:23.633Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-827968.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.1.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-05-19T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Angular template injection vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing an Angular template payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the Angular template executes in their browser context, allowing the attacker to modify application data, or disrupt application availability. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
                }
              ],
              "value": "An Angular template injection vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing an Angular template payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the Angular template executes in their browser context, allowing the attacker to modify application data, or disrupt application availability. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1336",
                  "description": "CWE-1336 Improper neutralization of special elements used in a template engine",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-19T13:17:21.852Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:3-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to v26.1.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to v26.1.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Angular template injection in Reports in Guardian/CMC before 26.1.0",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
                }
              ],
              "value": "Use internal firewall features to limit access to the web management interface."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
                }
              ],
              "value": "Review all accounts with access to it and delete unnecessary ones."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2025-40900",
        "datePublished": "2026-05-19T13:17:21.852Z",
        "dateReserved": "2025-04-16T09:04:35.923Z",
        "dateUpdated": "2026-06-09T09:02:23.633Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",