Search
Find a vulnerability
Search criteria
68 vulnerabilities found for simatic_wincc by siemens
CVE-2023-32736 (GCVE-0-2023-32736)
Vulnerability from nvd – Published: 2024-11-12 12:49 – Updated: 2025-01-14 10:27
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-02 19:49 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
39 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC S7-PLCSIM V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-PLCSIM V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V17 |
Affected:
0 , < V4.6.0.1
(custom)
|
|
| Siemens | TIA Portal Cloud V18 |
Affected:
0 , < V4.6.1.0
(custom)
|
|
| siemens | simatic_step_7 |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-plcsim |
Affected:
16 , < 17
(custom)
Affected: 17 , < * (custom) cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1 , < *
(custom)
Affected: v5.4sp3 , < * (custom) Affected: v5.5sp1 , < * (custom) cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
16 , < 17
(custom)
Affected: 17 , < 18 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < 17_update8
(custom)
Affected: 18 , < * (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud |
Affected:
16 , < *
(custom)
Affected: 17 , < * (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-plcsim",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp1",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp3",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.5sp1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "18",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17_update8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32736",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T19:49:50.974471Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T20:16:52.424Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Unified V18 (All versions \u003c V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions \u003c V17 Update 8), SIMATIC WinCC V18 (All versions \u003c V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions \u003c V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions \u003c V4.6.0.1), TIA Portal Cloud V18 (All versions \u003c V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:17.694Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-871035.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32736",
"datePublished": "2024-11-12T12:49:22.651Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-01-14T10:27:17.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-35783 (GCVE-0-2024-35783)
Vulnerability from nvd – Published: 2024-09-10 09:36 – Updated: 2025-01-14 10:30
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 15:12 UTC
CWE
- CWE-250 - Execution with Unnecessary Privileges
Assigner
References
1 reference
Impacted products
13 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Information Server 2020 |
Affected:
0 , < V2020 SP2 Update 5
(custom)
|
|
| Siemens | SIMATIC Information Server 2022 |
Affected:
0 , < V2022 SP1 Update 2
(custom)
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC06
(custom)
|
|
| Siemens | SIMATIC Process Historian 2020 |
Affected:
0 , < V2020 SP2 Update 5
(custom)
|
|
| Siemens | SIMATIC Process Historian 2022 |
Affected:
0 , < V2022 SP1 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 3
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 18
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 5
(custom)
|
|
| siemens | simatic_batch |
Affected:
0 , < *
(custom)
cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:* cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
7.4 , < 7.5_sp2_update_18
(custom)
Affected: 8.0 , < 8.0_update_5 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*",
"cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_batch",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.5_sp2_update_18",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-35783",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T15:12:46.700884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T17:31:08.389Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Information Server 2020",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2020 SP2 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Information Server 2022",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2022 SP1 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC06",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Process Historian 2020",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2020 SP2 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Process Historian 2022",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2022 SP1 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions \u003c V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions \u003c V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions \u003c V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions \u003c V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:30:01.253Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-629254.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-35783",
"datePublished": "2024-09-10T09:36:32.225Z",
"dateReserved": "2024-05-17T11:07:53.264Z",
"dateUpdated": "2025-01-14T10:30:01.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30321 (GCVE-0-2024-30321)
Vulnerability from nvd – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.
This could allow an unauthenticated remote attacker to retrieve information such as users and passwords.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-19 16:20 UTC
CWE
- CWE-359 - Exposure of Private Personal Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC05
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < V7.4 SP1 Update 23
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 17
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 5
(custom)
|
|
| siemens | simatic_pcs_7 |
Affected:
9.1 , < 10
(custom)
cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
7.4 , < 7.4_sp1_update_23
(custom)
Affected: 7.5 , < 7.5_sp2_update_17 (custom) Affected: 8.0 , < 8.0_update_5 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_runtime_professional |
Affected:
18 , < 19
(custom)
Affected: 19 , < 19_update_2 (custom) cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:32:07.025Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-883918.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_pcs_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "10",
"status": "affected",
"version": "9.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.4_sp1_update_23",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "7.5_sp2_update_17",
"status": "affected",
"version": "7.5",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.4_sp1_update_23",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "7.5_sp2_update_17",
"status": "affected",
"version": "7.5",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.4_sp1_update_23",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "7.5_sp2_update_17",
"status": "affected",
"version": "7.5",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_runtime_professional",
"vendor": "siemens",
"versions": [
{
"lessThan": "19",
"status": "affected",
"version": "18",
"versionType": "custom"
},
{
"lessThan": "19_update_2",
"status": "affected",
"version": "19",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_runtime_professional",
"vendor": "siemens",
"versions": [
{
"lessThan": "19",
"status": "affected",
"version": "18",
"versionType": "custom"
},
{
"lessThan": "19_update_2",
"status": "affected",
"version": "19",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T16:20:35.487955Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:53.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.4 SP1 Update 23",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.\r\nThis could allow an unauthenticated remote attacker to retrieve information such as users and passwords."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-359",
"description": "CWE-359: Exposure of Private Personal Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T12:49:28.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-883918.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30321",
"datePublished": "2024-07-09T12:04:43.997Z",
"dateReserved": "2024-03-26T16:42:16.797Z",
"dateUpdated": "2025-08-27T20:42:53.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32735 (GCVE-0-2023-32735)
Vulnerability from nvd – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:32
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 19:09 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
41 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < V16.7
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17.7
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | Soft Starter ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | TIA Portal Cloud V3.0 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| siemens | simatic_step_7_safety |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:* |
|
| siemens | simatic_step_7 |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
0 , < v17.7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp3
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.5sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v17
cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v18
cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | sirius_soft_starter_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | soft_starter_es |
Affected:
0 , < v16update7
(custom)
cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud_v3.0 |
Affected:
0 , < v18update2
(custom)
cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp3"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.5sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v17"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v18"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud_v3.0",
"vendor": "siemens",
"versions": [
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32735",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T19:09:33.343230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:32:53.425Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:25:36.815Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 2), SIMATIC STEP 7 V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 2), SIMATIC WinCC Unified V16 (All versions \u003c V16 Update 7), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 7), SIMATIC WinCC Unified V18 (All versions \u003c V18 Update 2), SIMATIC WinCC V16 (All versions \u003c V16.7), SIMATIC WinCC V17 (All versions \u003c V17.7), SIMATIC WinCC V18 (All versions \u003c V18 Update 2), SIMOCODE ES V16 (All versions \u003c V16 Update 7), SIMOCODE ES V17 (All versions \u003c V17 Update 7), SIMOCODE ES V18 (All versions \u003c V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions \u003c V17 Update 7), SIRIUS Safety ES V18 (All versions \u003c V18 Update 2), SIRIUS Soft Starter ES V17 (All versions \u003c V17 Update 7), SIRIUS Soft Starter ES V18 (All versions \u003c V18 Update 2), Soft Starter ES V16 (All versions \u003c V16 Update 7), TIA Portal Cloud V3.0 (All versions \u003c V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:04:26.871Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32735",
"datePublished": "2024-07-09T12:04:26.871Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-08-27T20:32:53.425Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48364 (GCVE-0-2023-48364)
Vulnerability from nvd – Published: 2024-02-13 08:59 – Updated: 2024-09-10 09:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-13 16:04 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | OpenPCS 7 V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC05
(custom)
|
|
| Siemens | SIMATIC Route Control V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 4
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 15
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 4
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-48364",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T16:04:15.175349Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:21:43.053Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:30:34.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 15",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:36:24.190Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-48364",
"datePublished": "2024-02-13T08:59:56.648Z",
"dateReserved": "2023-11-15T17:20:32.751Z",
"dateUpdated": "2024-09-10T09:36:24.190Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48363 (GCVE-0-2023-48363)
Vulnerability from nvd – Published: 2024-02-13 08:59 – Updated: 2024-09-10 09:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call)
communication protocol in the affected products do not
properly handle certain unorganized RPC messages. An
attacker could use this vulnerability to cause a denial of service
condition in the RPC server.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-13 16:37 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | OpenPCS 7 V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC05
(custom)
|
|
| Siemens | SIMATIC Route Control V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 4
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 15
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 4
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-48363",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T16:37:22.994141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:21:43.194Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:30:34.556Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 15",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:36:22.958Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-48363",
"datePublished": "2024-02-13T08:59:55.432Z",
"dateReserved": "2023-11-15T17:20:32.751Z",
"dateUpdated": "2024-09-10T09:36:22.958Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28829 (GCVE-0-2023-28829)
Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:52
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These
services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-03 01:45 UTC
CWE
- CWE-477 - Use of Obsolete Function
Assigner
References
1 reference
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC NET PC Software V14 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V15 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC |
Affected:
All versions < V8.0
|
|
| Siemens | SINAUT Software ST7sc |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T13:51:38.624Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28829",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:45:58.400145Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:52:55.603Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAUT Software ST7sc",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions \u003c V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-477",
"description": "CWE-477: Use of Obsolete Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:07.989Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-28829",
"datePublished": "2023-06-13T08:17:07.989Z",
"dateReserved": "2023-03-24T15:17:29.558Z",
"dateUpdated": "2025-01-03T01:52:55.603Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24287 (GCVE-0-2022-24287)
Vulnerability from nvd – Published: 2022-05-10 09:46 – Updated: 2025-04-21 13:53
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-18 15:23 UTC
CWE
- CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC06
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1 UC01
|
|
| Siemens | SIMATIC WinCC Runtime Professional V16 and earlier |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC Runtime Professional V17 |
Affected:
All versions < V17 Upd4
|
|
| Siemens | SIMATIC WinCC V7.3 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 21
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 8
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-24287",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:23:35.293523Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:53:48.015Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC06"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1 UC01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V16 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 21"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 8"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188: Insecure Default Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:11.010Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24287",
"datePublished": "2022-05-10T09:46:57.000Z",
"dateReserved": "2022-02-01T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:53:48.015Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40363 (GCVE-0-2021-40363)
Vulnerability from nvd – Published: 2022-02-09 15:17 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
Severity
No CVSS data available.
CWE
- CWE-538 - Insertion of Sensitive Information into Externally-Accessible File or Directory
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions <= V17 Update 4
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c= V17 Update 4"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-538",
"description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:17:13.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-40363",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.1 SP1"
}
]
}
},
{
"product_name": "SIMATIC WinCC V15 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15 SP1 Update 7"
}
]
}
},
{
"product_name": "SIMATIC WinCC V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 5"
}
]
}
},
{
"product_name": "SIMATIC WinCC V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V17 Update 2"
}
]
}
},
{
"product_name": "SIMATIC WinCC V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c= V17 Update 4"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Update 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40363",
"datePublished": "2022-02-09T15:17:04.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40360 (GCVE-0-2021-40360)
Vulnerability from nvd – Published: 2022-02-09 15:17 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Severity
No CVSS data available.
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.157Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T09:46:42.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-40360",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.1 SP1"
}
]
}
},
{
"product_name": "SIMATIC WinCC V15 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15 SP1 Update 7"
}
]
}
},
{
"product_name": "SIMATIC WinCC V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 5"
}
]
}
},
{
"product_name": "SIMATIC WinCC V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V17 Update 2"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Update 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40360",
"datePublished": "2022-02-09T15:17:03.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40364 (GCVE-0-2021-40364)
Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
Severity
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC04
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.470Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC04"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:02:00.354Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40364",
"datePublished": "2021-11-09T11:32:06.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.470Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40359 (GCVE-0-2021-40359)
Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
Severity
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
21 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | OpenPCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | OpenPCS 7 V9.0 |
Affected:
All versions < V9.0 Upd4
|
|
| Siemens | OpenPCS 7 V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC BATCH V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC BATCH V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V14 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V15 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V16 |
Affected:
All versions < V16 Update 6
|
|
| Siemens | SIMATIC NET PC Software V17 |
Affected:
All versions < V17 SP1
|
|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC04
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC Route Control V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC Route Control V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC Route Control V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.625Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC04"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 6), SIMATIC NET PC Software V17 (All versions \u003c V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:59.282Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40359",
"datePublished": "2021-11-09T11:32:05.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.625Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40358 (GCVE-0-2021-40358)
Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
Severity
9.9 (Critical)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC04
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.554Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC04"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:58.251Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40358",
"datePublished": "2021-11-09T11:32:04.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.554Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40142 (GCVE-0-2021-40142)
Vulnerability from nvd – Published: 2021-08-27 06:51 – Updated: 2024-08-04 02:27
VLAI
EPSS
VEX
Summary
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
Severity
7.5 (High)
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://opcfoundation.org/security-bulletins/ | x_refsource_MISC |
| https://files.opcfoundation.org/SecurityBulletins… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:27:31.711Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:N/I:N/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T11:06:13.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-40142",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:N/I:N/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://opcfoundation.org/security-bulletins/",
"refsource": "MISC",
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"name": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf",
"refsource": "MISC",
"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-40142",
"datePublished": "2021-08-27T06:51:28.000Z",
"dateReserved": "2021-08-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:27:31.711Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10048 (GCVE-0-2020-10048)
Vulnerability from nvd – Published: 2021-02-09 15:38 – Updated: 2024-08-04 10:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
Severity
No CVSS data available.
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC |
Affected:
All versions < V7.5 SP2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:50:57.903Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-09T15:38:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-10048",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 SP2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-10048",
"datePublished": "2021-02-09T15:38:17.000Z",
"dateReserved": "2020-03-04T00:00:00.000Z",
"dateUpdated": "2024-08-04T10:50:57.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32736 (GCVE-0-2023-32736)
Vulnerability from cvelistv5 – Published: 2024-11-12 12:49 – Updated: 2025-01-14 10:27
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-02 19:49 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
39 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC S7-PLCSIM V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-PLCSIM V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V17 |
Affected:
0 , < V4.6.0.1
(custom)
|
|
| Siemens | TIA Portal Cloud V18 |
Affected:
0 , < V4.6.1.0
(custom)
|
|
| siemens | simatic_step_7 |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-plcsim |
Affected:
16 , < 17
(custom)
Affected: 17 , < * (custom) cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1 , < *
(custom)
Affected: v5.4sp3 , < * (custom) Affected: v5.5sp1 , < * (custom) cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
16 , < 17
(custom)
Affected: 17 , < 18 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < 17_update8
(custom)
Affected: 18 , < * (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud |
Affected:
16 , < *
(custom)
Affected: 17 , < * (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-plcsim",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp1",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp3",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.5sp1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "18",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17_update8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32736",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T19:49:50.974471Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T20:16:52.424Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Unified V18 (All versions \u003c V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions \u003c V17 Update 8), SIMATIC WinCC V18 (All versions \u003c V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions \u003c V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions \u003c V4.6.0.1), TIA Portal Cloud V18 (All versions \u003c V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:17.694Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-871035.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32736",
"datePublished": "2024-11-12T12:49:22.651Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-01-14T10:27:17.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-35783 (GCVE-0-2024-35783)
Vulnerability from cvelistv5 – Published: 2024-09-10 09:36 – Updated: 2025-01-14 10:30
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 15:12 UTC
CWE
- CWE-250 - Execution with Unnecessary Privileges
Assigner
References
1 reference
Impacted products
13 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Information Server 2020 |
Affected:
0 , < V2020 SP2 Update 5
(custom)
|
|
| Siemens | SIMATIC Information Server 2022 |
Affected:
0 , < V2022 SP1 Update 2
(custom)
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC06
(custom)
|
|
| Siemens | SIMATIC Process Historian 2020 |
Affected:
0 , < V2020 SP2 Update 5
(custom)
|
|
| Siemens | SIMATIC Process Historian 2022 |
Affected:
0 , < V2022 SP1 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 3
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 18
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 5
(custom)
|
|
| siemens | simatic_batch |
Affected:
0 , < *
(custom)
cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:* cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
7.4 , < 7.5_sp2_update_18
(custom)
Affected: 8.0 , < 8.0_update_5 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*",
"cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_batch",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.5_sp2_update_18",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-35783",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T15:12:46.700884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T17:31:08.389Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Information Server 2020",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2020 SP2 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Information Server 2022",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2022 SP1 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC06",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Process Historian 2020",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2020 SP2 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Process Historian 2022",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2022 SP1 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions \u003c V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions \u003c V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions \u003c V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions \u003c V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:30:01.253Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-629254.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-35783",
"datePublished": "2024-09-10T09:36:32.225Z",
"dateReserved": "2024-05-17T11:07:53.264Z",
"dateUpdated": "2025-01-14T10:30:01.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30321 (GCVE-0-2024-30321)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:42
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.
This could allow an unauthenticated remote attacker to retrieve information such as users and passwords.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-19 16:20 UTC
CWE
- CWE-359 - Exposure of Private Personal Information to an Unauthorized Actor
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC05
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < V7.4 SP1 Update 23
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 17
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 5
(custom)
|
|
| siemens | simatic_pcs_7 |
Affected:
9.1 , < 10
(custom)
cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
7.4 , < 7.4_sp1_update_23
(custom)
Affected: 7.5 , < 7.5_sp2_update_17 (custom) Affected: 8.0 , < 8.0_update_5 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_runtime_professional |
Affected:
18 , < 19
(custom)
Affected: 19 , < 19_update_2 (custom) cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:32:07.025Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-883918.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_pcs_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "10",
"status": "affected",
"version": "9.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.4_sp1_update_23",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "7.5_sp2_update_17",
"status": "affected",
"version": "7.5",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.4_sp1_update_23",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "7.5_sp2_update_17",
"status": "affected",
"version": "7.5",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "7.4_sp1_update_23",
"status": "affected",
"version": "7.4",
"versionType": "custom"
},
{
"lessThan": "7.5_sp2_update_17",
"status": "affected",
"version": "7.5",
"versionType": "custom"
},
{
"lessThan": "8.0_update_5",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_runtime_professional",
"vendor": "siemens",
"versions": [
{
"lessThan": "19",
"status": "affected",
"version": "18",
"versionType": "custom"
},
{
"lessThan": "19_update_2",
"status": "affected",
"version": "19",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_runtime_professional",
"vendor": "siemens",
"versions": [
{
"lessThan": "19",
"status": "affected",
"version": "18",
"versionType": "custom"
},
{
"lessThan": "19_update_2",
"status": "affected",
"version": "19",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T16:20:35.487955Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:53.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.4 SP1 Update 23",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.\r\nThis could allow an unauthenticated remote attacker to retrieve information such as users and passwords."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-359",
"description": "CWE-359: Exposure of Private Personal Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T12:49:28.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-883918.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30321",
"datePublished": "2024-07-09T12:04:43.997Z",
"dateReserved": "2024-03-26T16:42:16.797Z",
"dateUpdated": "2025-08-27T20:42:53.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32735 (GCVE-0-2023-32735)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:32
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 19:09 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
41 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < V16.7
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17.7
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | Soft Starter ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | TIA Portal Cloud V3.0 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| siemens | simatic_step_7_safety |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:* |
|
| siemens | simatic_step_7 |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
0 , < v17.7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp3
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.5sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v17
cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v18
cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | sirius_soft_starter_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | soft_starter_es |
Affected:
0 , < v16update7
(custom)
cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud_v3.0 |
Affected:
0 , < v18update2
(custom)
cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp3"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.5sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v17"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v18"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud_v3.0",
"vendor": "siemens",
"versions": [
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32735",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T19:09:33.343230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:32:53.425Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:25:36.815Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 2), SIMATIC STEP 7 V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 2), SIMATIC WinCC Unified V16 (All versions \u003c V16 Update 7), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 7), SIMATIC WinCC Unified V18 (All versions \u003c V18 Update 2), SIMATIC WinCC V16 (All versions \u003c V16.7), SIMATIC WinCC V17 (All versions \u003c V17.7), SIMATIC WinCC V18 (All versions \u003c V18 Update 2), SIMOCODE ES V16 (All versions \u003c V16 Update 7), SIMOCODE ES V17 (All versions \u003c V17 Update 7), SIMOCODE ES V18 (All versions \u003c V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions \u003c V17 Update 7), SIRIUS Safety ES V18 (All versions \u003c V18 Update 2), SIRIUS Soft Starter ES V17 (All versions \u003c V17 Update 7), SIRIUS Soft Starter ES V18 (All versions \u003c V18 Update 2), Soft Starter ES V16 (All versions \u003c V16 Update 7), TIA Portal Cloud V3.0 (All versions \u003c V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:04:26.871Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32735",
"datePublished": "2024-07-09T12:04:26.871Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-08-27T20:32:53.425Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48364 (GCVE-0-2023-48364)
Vulnerability from cvelistv5 – Published: 2024-02-13 08:59 – Updated: 2024-09-10 09:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-13 16:04 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | OpenPCS 7 V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC05
(custom)
|
|
| Siemens | SIMATIC Route Control V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 4
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 15
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 4
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-48364",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T16:04:15.175349Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:21:43.053Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:30:34.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 15",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:36:24.190Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-48364",
"datePublished": "2024-02-13T08:59:56.648Z",
"dateReserved": "2023-11-15T17:20:32.751Z",
"dateUpdated": "2024-09-10T09:36:24.190Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48363 (GCVE-0-2023-48363)
Vulnerability from cvelistv5 – Published: 2024-02-13 08:59 – Updated: 2024-09-10 09:36
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call)
communication protocol in the affected products do not
properly handle certain unorganized RPC messages. An
attacker could use this vulnerability to cause a denial of service
condition in the RPC server.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-13 16:37 UTC
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | OpenPCS 7 V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
0 , < V9.1 SP2 UC05
(custom)
|
|
| Siemens | SIMATIC Route Control V9.1 |
Affected:
All versions < V9.1 SP2 UC05
|
|
| Siemens | SIMATIC WinCC Runtime Professional V18 |
Affected:
0 , < V18 Update 4
(custom)
|
|
| Siemens | SIMATIC WinCC Runtime Professional V19 |
Affected:
0 , < V19 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
0 , < V7.5 SP2 Update 15
(custom)
|
|
| Siemens | SIMATIC WinCC V8.0 |
Affected:
0 , < V8.0 Update 4
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-48363",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T16:37:22.994141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:21:43.194Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:30:34.556Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC05",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP2 UC05"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.5 SP2 Update 15",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V8.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:36:22.958Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-48363",
"datePublished": "2024-02-13T08:59:55.432Z",
"dateReserved": "2023-11-15T17:20:32.751Z",
"dateUpdated": "2024-09-10T09:36:22.958Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28829 (GCVE-0-2023-28829)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2025-01-03 01:52
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These
services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-03 01:45 UTC
CWE
- CWE-477 - Use of Obsolete Function
Assigner
References
1 reference
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC NET PC Software V14 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V15 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC |
Affected:
All versions < V8.0
|
|
| Siemens | SINAUT Software ST7sc |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T13:51:38.624Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28829",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:45:58.400145Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:52:55.603Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAUT Software ST7sc",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions \u003c V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-477",
"description": "CWE-477: Use of Obsolete Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:07.989Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-28829",
"datePublished": "2023-06-13T08:17:07.989Z",
"dateReserved": "2023-03-24T15:17:29.558Z",
"dateUpdated": "2025-01-03T01:52:55.603Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24287 (GCVE-0-2022-24287)
Vulnerability from cvelistv5 – Published: 2022-05-10 09:46 – Updated: 2025-04-21 13:53
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-18 15:23 UTC
CWE
- CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC06
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1 UC01
|
|
| Siemens | SIMATIC WinCC Runtime Professional V16 and earlier |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC Runtime Professional V17 |
Affected:
All versions < V17 Upd4
|
|
| Siemens | SIMATIC WinCC V7.3 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 21
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 8
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-24287",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:23:35.293523Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:53:48.015Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC06"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1 UC01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V16 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 21"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 8"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188: Insecure Default Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:11.010Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-24287",
"datePublished": "2022-05-10T09:46:57.000Z",
"dateReserved": "2022-02-01T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:53:48.015Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40363 (GCVE-0-2021-40363)
Vulnerability from cvelistv5 – Published: 2022-02-09 15:17 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
Severity
No CVSS data available.
CWE
- CWE-538 - Insertion of Sensitive Information into Externally-Accessible File or Directory
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions <= V17 Update 4
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c= V17 Update 4"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-538",
"description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:17:13.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-40363",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.1 SP1"
}
]
}
},
{
"product_name": "SIMATIC WinCC V15 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15 SP1 Update 7"
}
]
}
},
{
"product_name": "SIMATIC WinCC V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 5"
}
]
}
},
{
"product_name": "SIMATIC WinCC V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V17 Update 2"
}
]
}
},
{
"product_name": "SIMATIC WinCC V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c= V17 Update 4"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Update 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40363",
"datePublished": "2022-02-09T15:17:04.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40360 (GCVE-0-2021-40360)
Vulnerability from cvelistv5 – Published: 2022-02-09 15:17 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Severity
No CVSS data available.
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.157Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T09:46:42.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-40360",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.1 SP1"
}
]
}
},
{
"product_name": "SIMATIC WinCC V15 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15 SP1 Update 7"
}
]
}
},
{
"product_name": "SIMATIC WinCC V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 5"
}
]
}
},
{
"product_name": "SIMATIC WinCC V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V17 Update 2"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Update 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 SP2 Update 6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40360",
"datePublished": "2022-02-09T15:17:03.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40364 (GCVE-0-2021-40364)
Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
Severity
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC04
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.470Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC04"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:02:00.354Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40364",
"datePublished": "2021-11-09T11:32:06.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.470Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40359 (GCVE-0-2021-40359)
Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
Severity
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
21 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | OpenPCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | OpenPCS 7 V9.0 |
Affected:
All versions < V9.0 Upd4
|
|
| Siemens | OpenPCS 7 V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC BATCH V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC BATCH V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC BATCH V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V14 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V15 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V16 |
Affected:
All versions < V16 Update 6
|
|
| Siemens | SIMATIC NET PC Software V17 |
Affected:
All versions < V17 SP1
|
|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC04
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC Route Control V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC Route Control V9.0 |
Affected:
All versions
|
|
| Siemens | SIMATIC Route Control V9.1 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.625Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC04"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 6), SIMATIC NET PC Software V17 (All versions \u003c V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:59.282Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40359",
"datePublished": "2021-11-09T11:32:05.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.625Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40358 (GCVE-0-2021-40358)
Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-04 02:44
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
Severity
9.9 (Critical)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 |
Affected:
All versions
|
|
| Siemens | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP3 UC04
|
|
| Siemens | SIMATIC PCS 7 V9.1 |
Affected:
All versions < V9.1 SP1
|
|
| Siemens | SIMATIC WinCC V15 and earlier |
Affected:
All versions < V15 SP1 Update 7
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
All versions < V16 Update 5
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
All versions < V17 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 19
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP2 Update 5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.554Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3 UC04"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.1 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V15 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15 SP1 Update 7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2 Update 5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:58.251Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40358",
"datePublished": "2021-11-09T11:32:04.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:09.554Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40142 (GCVE-0-2021-40142)
Vulnerability from cvelistv5 – Published: 2021-08-27 06:51 – Updated: 2024-08-04 02:27
VLAI
EPSS
VEX
Summary
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
Severity
7.5 (High)
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://opcfoundation.org/security-bulletins/ | x_refsource_MISC |
| https://files.opcfoundation.org/SecurityBulletins… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:27:31.711Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:N/I:N/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-10T11:06:13.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-40142",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:N/I:N/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://opcfoundation.org/security-bulletins/",
"refsource": "MISC",
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"name": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf",
"refsource": "MISC",
"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-40142",
"datePublished": "2021-08-27T06:51:28.000Z",
"dateReserved": "2021-08-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:27:31.711Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10048 (GCVE-0-2020-10048)
Vulnerability from cvelistv5 – Published: 2021-02-09 15:38 – Updated: 2024-08-04 10:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
Severity
No CVSS data available.
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC PCS 7 |
Affected:
All versions
|
|
| Siemens | SIMATIC WinCC |
Affected:
All versions < V7.5 SP2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:50:57.903Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-09T15:38:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-10048",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 SP2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-10048",
"datePublished": "2021-02-09T15:38:17.000Z",
"dateReserved": "2020-03-04T00:00:00.000Z",
"dateUpdated": "2024-08-04T10:50:57.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}