ICSA-21-280-02
Vulnerability from csaf_cisa - Published: 2021-10-07 00:00 - Updated: 2021-10-07 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
{
"document": {
"acknowledgments": [
{
"names": [
"Victor Mayoral Vilches"
],
"organization": "Alias Robotics",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could lead to privilege escalation, data exfiltration, control of the robot, and a denial-of-service condition.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing, Healthcare and Public Health, Transportation Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Denmark",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-280-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-280-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-280-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-280-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Mobile Industrial Robots Vehicles and MiR Fleet Software",
"tracking": {
"current_release_date": "2021-10-07T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-280-02",
"initial_release_date": "2021-10-07T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-10-07T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-280-02 Mobile Industrial Robots MiR Fleet Vehicles"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 2.10.2.1",
"product": {
"name": "MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 2.10.2.1",
"product": {
"name": "MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "MiR Fleet in MiR Fleet Software"
}
],
"category": "vendor",
"name": "Mobile Industrial Robots (MiR)"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-7184",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "An authenticated local attacker with an account on the MiR robot operating system can exploit a Linux kernel vulnerability to perform privilege escalation to root or cause a denial-of-service condition.CVE-2017-7184 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7184"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-18255",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "A handler in the Linux kernel prior to Version 4.11 allows local users to cause a denial-of-service condition or other unspecified impact(s) via use of a large value.CVE-2017-18255 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-18255"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10271",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"category": "summary",
"text": "Two APIs to the Robot Operating System (ROS) used in MiR robots were accessible from both wired and wireless network interfaces. Using these APIs, an attacker could take control of the robot, cause a denial-of-service condition, and exfiltrate data over the web interface.CVE-2020-10271 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10271"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10272",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "Robot Operating System (ROS) default packages are used, which expose the computational graph without any authentication. This could allow an attacker with access to the internal wireless and wired networks to take control of the robot.CVE-2020-10272 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10272"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10273",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An attacker with physical access to the hard drive, or an attacker with a local account on the robot operating system could extract sensitive data.CVE-2020-10273 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10273"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10276",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "MiR robots shipped before June 2020 had default passwords set for the SICK safety PLC. An attacker with access to the internal network of the robot could use the default credentials to manipulate the safety PLC, effectively disabling the emergency stop function.CVE-2020-10276 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10276"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10277",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "MiR robots ship with the option to boot from a connected USB drive. The ability to boot from USB is an insecure default configuration that is changeable by integrators. Integrators are informed and instructed in writing to evaluate disabling USB boot. If left enabled, an attacker with physical access to the robot could abuse this functionality to manipulate or exfiltrate data stored on the robot \u0027s hard drive.CVE-2020-10277 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10277"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10278",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The lack of a BIOS password is an insecure default configuration, changeable by integrators. Integrators are informed and instructed in writing to evaluate BIOS protection.CVE-2020-10278 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10278"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10279",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "summary",
"text": "MiR software versions prior to v2.8.3 contain system configurations with insecure defaults, allowing an authorized local attacker with access to the robot operating system (ROS) to perform privilege escalation or cause denial-of-service.CVE-2020-10279 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10279"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10280",
"cwe": {
"id": "CWE-239",
"name": "Failure to Handle Incomplete Element"
},
"notes": [
{
"category": "summary",
"text": "The Apache server on Port 80 hosting the web interface is vulnerable to a denial-of-service condition when an attacker spams incomplete HTTP headers, effectively blocking the access to the dashboard.CVE-2020-10280 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10280"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.