CVE-2020-10276 (GCVE-0-2020-10276)
Vulnerability from cvelistv5 – Published: 2020-06-24 04:50 – Updated: 2024-09-16 17:08| URL | Tags |
|---|---|
| https://github.com/aliasrobotics/RVD/issues/2558 | x_refsource_CONFIRM |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Mobile Industrial Robots A/S | MiR100 |
Affected:
v2.8.1.1 and before
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:58:39.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2558"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MiR100",
"vendor": "Mobile Industrial Robots A/S",
"versions": [
{
"status": "affected",
"version": "v2.8.1.1 and before"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Bernhard Dieber (Joanneum Research)"
}
],
"datePublic": "2020-06-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-24T04:50:14.000Z",
"orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
"shortName": "Alias"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2558"
}
],
"source": {
"defect": [
"RVD#2558"
],
"discovery": "EXTERNAL"
},
"title": "RVD#2558: Default credentials on SICK PLC allows disabling safety features",
"x_generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@aliasrobotics.com",
"DATE_PUBLIC": "2020-06-24T04:46:26 +00:00",
"ID": "CVE-2020-10276",
"STATE": "PUBLIC",
"TITLE": "RVD#2558: Default credentials on SICK PLC allows disabling safety features"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MiR100",
"version": {
"version_data": [
{
"version_value": "v2.8.1.1 and before"
}
]
}
}
]
},
"vendor_name": "Mobile Industrial Robots A/S"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Bernhard Dieber (Joanneum Research)"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device."
}
]
},
"generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "critical",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/aliasrobotics/RVD/issues/2558",
"refsource": "CONFIRM",
"url": "https://github.com/aliasrobotics/RVD/issues/2558"
}
]
},
"source": {
"defect": [
"RVD#2558"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
"assignerShortName": "Alias",
"cveId": "CVE-2020-10276",
"datePublished": "2020-06-24T04:50:14.520Z",
"dateReserved": "2020-03-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:08:36.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-10276",
"date": "2026-11-12",
"epss": "0.01536",
"percentile": "0.75216"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mobile-industrial-robots:mir100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4C1ED80A-1AE1-4868-AD13-F37079F69B60",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mobile-industrial-robots:mir100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "11F1060F-0F43-4920-A05D-593E784B1A0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mobile-industrial-robots:mir200_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E52858B-51DE-44BC-A4BB-D199F1281D72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mobile-industrial-robots:mir200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2B0F7F08-D5D5-4DA8-B2B2-5EA2997AEE3D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mobile-industrial-robots:mir250_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0F19DD45-1C6E-498C-A961-5EDB4823B12C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mobile-industrial-robots:mir250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44C6FCBE-E111-419E-8F8D-2F4702D821BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mobile-industrial-robots:mir500_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C63DB5B-961D-4FDD-AB12-01DC24AFC0B9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mobile-industrial-robots:mir500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E2BC5C9E-1AF3-4009-844E-6E64E4D766A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mobile-industrial-robots:mir1000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "171A2B04-114B-4C5F-9F2C-515A1E37F300",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mobile-industrial-robots:mir1000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C86EB588-CD48-456B-90C6-C482636508AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:easyrobotics:er200_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "42AB077F-A829-4A9F-8AFF-CBC9222EAE55",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:easyrobotics:er200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C275F303-4494-4C06-95CC-8969E01F8ADA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:easyrobotics:er-lite_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68599AB3-679D-4E86-B8F4-7939A0373EA2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:easyrobotics:er-lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "53543812-4D0D-4191-8B21-803D2F9790B6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:easyrobotics:er-flex_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1252DDB6-D090-499B-B505-E17625DB88AC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:easyrobotics:er-flex:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9D84C826-05A4-44A6-BD12-77805A993A5D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:easyrobotics:er-one_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29230027-8A11-48CA-A4E5-63953EB7CAE3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:easyrobotics:er-one:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C7FFA6B9-1A77-4C25-8120-6844B8700527",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:uvd-robots:uvd_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0C870ABF-C324-442E-9738-025397CB3C47",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:uvd-robots:uvd:-:*:*:*:*:*:*:*",
"matchCriteriaId": "87684074-A107-4FE3-A840-C5CB3B8025AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device."
},
{
"lang": "es",
"value": "La contrase\u00f1a para el PLC de seguridad es la predeterminada y, por lo tanto, f\u00e1cil de encontrar (en manuales, etc.). Esto permite a un programa manipulado ser cargado al PLC de seguridad, deshabilitando efectivamente la parada de emergencia en caso de que un objeto est\u00e9 demasiado cerca del robot. Una navegaci\u00f3n y cualquier otro componente dependiente del esc\u00e1ner l\u00e1ser no est\u00e1n afectados (por lo tanto, es dif\u00edcil de detectar antes de que ocurra algo), aunque la configuraci\u00f3n del esc\u00e1ner l\u00e1ser puede tambi\u00e9n estar afectada alterando a\u00fan m\u00e1s la seguridad del dispositivo"
}
],
"id": "CVE-2020-10276",
"lastModified": "2024-11-21T04:55:07.250",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cve@aliasrobotics.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-24T05:15:13.270",
"references": [
{
"source": "cve@aliasrobotics.com",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2558"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2558"
}
],
"sourceIdentifier": "cve@aliasrobotics.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "cve@aliasrobotics.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.