CVE-2020-10271 (GCVE-0-2020-10271)
Vulnerability from cvelistv5 – Published: 2020-06-24 04:40 – Updated: 2024-09-16 22:02
VLAI
EPSS
Title
RVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired ones
Summary
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR's operations are centered around the framework (ROS).
Severity
10 (Critical)
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/aliasrobotics/RVD/issues/2555 | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Mobile Industrial Robots A/S | MiR100 |
Affected:
v2.8.1.1 and before
|
Date Public
2020-06-24 00:00
Credits
Víctor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier Sáez de Cámara (Alias Robotics)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:58:40.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MiR100",
"vendor": "Mobile Industrial Robots A/S",
"versions": [
{
"status": "affected",
"version": "v2.8.1.1 and before"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "V\u00edctor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier S\u00e1ez de C\u00e1mara (Alias Robotics)"
}
],
"datePublic": "2020-06-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS)."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-24T04:40:18.000Z",
"orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
"shortName": "Alias"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
],
"source": {
"defect": [
"RVD#2555"
],
"discovery": "EXTERNAL"
},
"title": "RVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired ones",
"x_generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@aliasrobotics.com",
"DATE_PUBLIC": "2020-06-24T04:34:51 +00:00",
"ID": "CVE-2020-10271",
"STATE": "PUBLIC",
"TITLE": "RVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired ones"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MiR100",
"version": {
"version_data": [
{
"version_value": "v2.8.1.1 and before"
}
]
}
}
]
},
"vendor_name": "Mobile Industrial Robots A/S"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "V\u00edctor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier S\u00e1ez de C\u00e1mara (Alias Robotics)"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS)."
}
]
},
"generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "critical",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/aliasrobotics/RVD/issues/2555",
"refsource": "CONFIRM",
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
]
},
"source": {
"defect": [
"RVD#2555"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
"assignerShortName": "Alias",
"cveId": "CVE-2020-10271",
"datePublished": "2020-06-24T04:40:18.659Z",
"dateReserved": "2020-03-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:02:17.241Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-10271",
"date": "2026-05-29",
"epss": "0.00402",
"percentile": "0.61078"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-10271\",\"sourceIdentifier\":\"cve@aliasrobotics.com\",\"published\":\"2020-06-24T05:15:12.847\",\"lastModified\":\"2024-11-21T04:55:06.540\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS).\"},{\"lang\":\"es\",\"value\":\"MiR100, MiR200 y otros robots MiR usan los paquetes predeterminados del Robot Operating System (ROS) que exponen el gr\u00e1fico computacional a todas las interfaces de red, inal\u00e1mbricas y cableadas. Este es el resultado de una configuraci\u00f3n incorrecta y puede ser mitigado ajustando el ROS de forma apropiada y/o aplicando parches seg\u00fan sea apropiado. Actualmente, puede accederse completamente al gr\u00e1fico computacional del ROS desde los puertos expuestos cableados. En combinaci\u00f3n con otros fallos como CVE-2020-10269, el gr\u00e1fico computacional tambi\u00e9n puede ser recuperado e interactuado desde redes inal\u00e1mbricas. Esto permite a un operador malicioso tomar el control de la l\u00f3gica del ROS y, en consecuencia, del robot completo dado que las operaciones de MiR se centran en el framework (ROS)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"cve@aliasrobotics.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cve@aliasrobotics.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-668\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-668\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir100_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"BBDEDA2D-26AB-4F23-B672-D0C89A7BEFB9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0989373-02AB-4E05-BAC2-0522A641D73A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir200_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"78E261B1-C56F-4428-9D53-5BBCCACEAFCF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BF40B1F-0DD2-4B8A-BFBA-A7E641DC3316\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir250_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"877EEDC4-E86F-420D-81C6-3F632C787003\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD1AE2A0-D83D-441B-856B-7E6FAB065C0D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir500_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"335CA5FE-5AFD-4D49-9A88-1CD71C9281BE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F57611E0-5CB2-40FD-8420-ED13A1C4863F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir1000_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"6865A559-8CA9-4F51-AC43-35BDF5201B91\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04043B16-E401-4D2C-9812-71923CEA2716\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mobile-industrial-robotics:er200_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"39BD42AA-95E1-4A02-BB9D-C54AE6BAF9B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mobile-industrial-robotics:er200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8A47E5E-7754-47EA-B02D-8A7F54124ED4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enabled-robotics:er-lite_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"DF0E5CFB-6C15-4BB1-97D8-DD52F68190DD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enabled-robotics:er-lite:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"472A560B-547D-4C9F-BE86-ED602FA32799\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enabled-robotics:er-flex_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"D5528AFD-75DF-4296-9A29-4BD00AB76273\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enabled-robotics:er-flex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"654488E4-161E-40B5-9E0B-BE68F5F38E91\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enabled-robotics:er-one_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"CD6E62F4-9C15-49AA-BFB7-81443D40B9B9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enabled-robotics:er-one:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BB77317-78C0-4800-8E1D-498979B6CB06\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:uvd-robots:uvd_robots_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"A7452D74-36A5-4C87-AA20-8E9A80724EAA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:uvd-robots:uvd_robots:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FD4ACEB-1184-47AB-86E4-732DA183E8AE\"}]}]}],\"references\":[{\"url\":\"https://github.com/aliasrobotics/RVD/issues/2555\",\"source\":\"cve@aliasrobotics.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/aliasrobotics/RVD/issues/2555\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
FKIE_CVE-2020-10271
Vulnerability from fkie_nvd - Published: 2020-06-24 05:15 - Updated: 2024-11-21 04:55
Severity
Summary
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR's operations are centered around the framework (ROS).
References
| URL | Tags | ||
|---|---|---|---|
| cve@aliasrobotics.com | https://github.com/aliasrobotics/RVD/issues/2555 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/aliasrobotics/RVD/issues/2555 | Exploit, Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:aliasrobotics:mir100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BBDEDA2D-26AB-4F23-B672-D0C89A7BEFB9",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:aliasrobotics:mir100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0989373-02AB-4E05-BAC2-0522A641D73A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:aliasrobotics:mir200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "78E261B1-C56F-4428-9D53-5BBCCACEAFCF",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:aliasrobotics:mir200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7BF40B1F-0DD2-4B8A-BFBA-A7E641DC3316",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:aliasrobotics:mir250_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "877EEDC4-E86F-420D-81C6-3F632C787003",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:aliasrobotics:mir250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD1AE2A0-D83D-441B-856B-7E6FAB065C0D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:aliasrobotics:mir500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "335CA5FE-5AFD-4D49-9A88-1CD71C9281BE",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:aliasrobotics:mir500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F57611E0-5CB2-40FD-8420-ED13A1C4863F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:aliasrobotics:mir1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6865A559-8CA9-4F51-AC43-35BDF5201B91",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:aliasrobotics:mir1000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "04043B16-E401-4D2C-9812-71923CEA2716",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mobile-industrial-robotics:er200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "39BD42AA-95E1-4A02-BB9D-C54AE6BAF9B2",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mobile-industrial-robotics:er200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8A47E5E-7754-47EA-B02D-8A7F54124ED4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:enabled-robotics:er-lite_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DF0E5CFB-6C15-4BB1-97D8-DD52F68190DD",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:enabled-robotics:er-lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "472A560B-547D-4C9F-BE86-ED602FA32799",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:enabled-robotics:er-flex_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D5528AFD-75DF-4296-9A29-4BD00AB76273",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:enabled-robotics:er-flex:-:*:*:*:*:*:*:*",
"matchCriteriaId": "654488E4-161E-40B5-9E0B-BE68F5F38E91",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:enabled-robotics:er-one_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CD6E62F4-9C15-49AA-BFB7-81443D40B9B9",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:enabled-robotics:er-one:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BB77317-78C0-4800-8E1D-498979B6CB06",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:uvd-robots:uvd_robots_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7452D74-36A5-4C87-AA20-8E9A80724EAA",
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:uvd-robots:uvd_robots:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FD4ACEB-1184-47AB-86E4-732DA183E8AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS)."
},
{
"lang": "es",
"value": "MiR100, MiR200 y otros robots MiR usan los paquetes predeterminados del Robot Operating System (ROS) que exponen el gr\u00e1fico computacional a todas las interfaces de red, inal\u00e1mbricas y cableadas. Este es el resultado de una configuraci\u00f3n incorrecta y puede ser mitigado ajustando el ROS de forma apropiada y/o aplicando parches seg\u00fan sea apropiado. Actualmente, puede accederse completamente al gr\u00e1fico computacional del ROS desde los puertos expuestos cableados. En combinaci\u00f3n con otros fallos como CVE-2020-10269, el gr\u00e1fico computacional tambi\u00e9n puede ser recuperado e interactuado desde redes inal\u00e1mbricas. Esto permite a un operador malicioso tomar el control de la l\u00f3gica del ROS y, en consecuencia, del robot completo dado que las operaciones de MiR se centran en el framework (ROS)"
}
],
"id": "CVE-2020-10271",
"lastModified": "2024-11-21T04:55:06.540",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "cve@aliasrobotics.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-24T05:15:12.847",
"references": [
{
"source": "cve@aliasrobotics.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
],
"sourceIdentifier": "cve@aliasrobotics.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-668"
}
],
"source": "cve@aliasrobotics.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-668"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-W563-XMMW-PQWR
Vulnerability from github – Published: 2022-05-24 17:21 – Updated: 2022-05-24 17:21
VLAI
Details
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR's operations are centered around the framework (ROS).
{
"affected": [],
"aliases": [
"CVE-2020-10271"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-06-24T05:15:00Z",
"severity": "MODERATE"
},
"details": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS).",
"id": "GHSA-w563-xmmw-pqwr",
"modified": "2022-05-24T17:21:32Z",
"published": "2022-05-24T17:21:32Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-10271"
},
{
"type": "WEB",
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2020-10271
Vulnerability from gsd - Updated: 2023-12-13 01:22Details
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR's operations are centered around the framework (ROS).
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2020-10271",
"description": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS).",
"id": "GSD-2020-10271"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-10271"
],
"details": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS).",
"id": "GSD-2020-10271",
"modified": "2023-12-13T01:22:04.521757Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@aliasrobotics.com",
"DATE_PUBLIC": "2020-06-24T04:34:51 +00:00",
"ID": "CVE-2020-10271",
"STATE": "PUBLIC",
"TITLE": "RVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired ones"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MiR100",
"version": {
"version_data": [
{
"version_value": "v2.8.1.1 and before"
}
]
}
}
]
},
"vendor_name": "Mobile Industrial Robots A/S"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "V\u00edctor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier S\u00e1ez de C\u00e1mara (Alias Robotics)"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS)."
}
]
},
"generator": {
"engine": "Robot Vulnerability Database (RVD)"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "critical",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/aliasrobotics/RVD/issues/2555",
"refsource": "CONFIRM",
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
]
},
"source": {
"defect": [
"RVD#2555"
],
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:aliasrobotics:mir100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:aliasrobotics:mir100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:aliasrobotics:mir200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:aliasrobotics:mir200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:aliasrobotics:mir250_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:aliasrobotics:mir250:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:aliasrobotics:mir500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:aliasrobotics:mir500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:aliasrobotics:mir1000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:aliasrobotics:mir1000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mobile-industrial-robotics:er200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mobile-industrial-robotics:er200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:enabled-robotics:er-lite_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:enabled-robotics:er-lite:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:enabled-robotics:er-flex_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:enabled-robotics:er-flex:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:enabled-robotics:er-one_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:enabled-robotics:er-one:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:uvd-robots:uvd_robots_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.8.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:uvd-robots:uvd_robots:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@aliasrobotics.com",
"ID": "CVE-2020-10271"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR\u0027s operations are centered around the framework (ROS)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-668"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/aliasrobotics/RVD/issues/2555",
"refsource": "CONFIRM",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/aliasrobotics/RVD/issues/2555"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2020-07-06T15:54Z",
"publishedDate": "2020-06-24T05:15Z"
}
}
}
ICSA-21-280-02
Vulnerability from csaf_cisa - Published: 2021-10-07 00:00 - Updated: 2021-10-07 00:00Summary
Mobile Industrial Robots Vehicles and MiR Fleet Software
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation: Successful exploitation of these vulnerabilities could lead to privilege escalation, data exfiltration, control of the robot, and a denial-of-service condition.
Critical infrastructure sectors: Critical Manufacturing, Healthcare and Public Health, Transportation Systems
Countries/areas deployed: Worldwide
Company headquarters location: Denmark
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
7.8 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
7.8 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
9.8 (Critical)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
8.8 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
6.2 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
8.8 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
6.4 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
4.6 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
8.4 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
7.5 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1
Mobile Industrial Robots (MiR) / MiR Fleet in MiR Fleet Software
|
< 2.10.2.1 |
Mitigation
fix
Mitigation
fix
Mitigation
|
References
23 references
Acknowledgments
Alias Robotics
Victor Mayoral Vilches
{
"document": {
"acknowledgments": [
{
"names": [
"Victor Mayoral Vilches"
],
"organization": "Alias Robotics",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could lead to privilege escalation, data exfiltration, control of the robot, and a denial-of-service condition.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing, Healthcare and Public Health, Transportation Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Denmark",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-280-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-280-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-280-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-280-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Mobile Industrial Robots Vehicles and MiR Fleet Software",
"tracking": {
"current_release_date": "2021-10-07T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-280-02",
"initial_release_date": "2021-10-07T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-10-07T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-280-02 Mobile Industrial Robots MiR Fleet Vehicles"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 2.10.2.1",
"product": {
"name": "MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software: versions prior to 2.10.2.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "MiR100 MiR200 MiR250 MiR500 MiR1000 in MiR Robot Software"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 2.10.2.1",
"product": {
"name": "MiR Fleet in MiR Fleet Software: versions prior to 2.10.2.1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "MiR Fleet in MiR Fleet Software"
}
],
"category": "vendor",
"name": "Mobile Industrial Robots (MiR)"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-7184",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "An authenticated local attacker with an account on the MiR robot operating system can exploit a Linux kernel vulnerability to perform privilege escalation to root or cause a denial-of-service condition.CVE-2017-7184 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7184"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-18255",
"cwe": {
"id": "CWE-190",
"name": "Integer Overflow or Wraparound"
},
"notes": [
{
"category": "summary",
"text": "A handler in the Linux kernel prior to Version 4.11 allows local users to cause a denial-of-service condition or other unspecified impact(s) via use of a large value.CVE-2017-18255 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-18255"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10271",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"category": "summary",
"text": "Two APIs to the Robot Operating System (ROS) used in MiR robots were accessible from both wired and wireless network interfaces. Using these APIs, an attacker could take control of the robot, cause a denial-of-service condition, and exfiltrate data over the web interface.CVE-2020-10271 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10271"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10272",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "Robot Operating System (ROS) default packages are used, which expose the computational graph without any authentication. This could allow an attacker with access to the internal wireless and wired networks to take control of the robot.CVE-2020-10272 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10272"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10273",
"cwe": {
"id": "CWE-311",
"name": "Missing Encryption of Sensitive Data"
},
"notes": [
{
"category": "summary",
"text": "An attacker with physical access to the hard drive, or an attacker with a local account on the robot operating system could extract sensitive data.CVE-2020-10273 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10273"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10276",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "MiR robots shipped before June 2020 had default passwords set for the SICK safety PLC. An attacker with access to the internal network of the robot could use the default credentials to manipulate the safety PLC, effectively disabling the emergency stop function.CVE-2020-10276 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10276"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10277",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "MiR robots ship with the option to boot from a connected USB drive. The ability to boot from USB is an insecure default configuration that is changeable by integrators. Integrators are informed and instructed in writing to evaluate disabling USB boot. If left enabled, an attacker with physical access to the robot could abuse this functionality to manipulate or exfiltrate data stored on the robot \u0027s hard drive.CVE-2020-10277 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10277"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10278",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The lack of a BIOS password is an insecure default configuration, changeable by integrators. Integrators are informed and instructed in writing to evaluate BIOS protection.CVE-2020-10278 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10278"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10279",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"category": "summary",
"text": "MiR software versions prior to v2.8.3 contain system configurations with insecure defaults, allowing an authorized local attacker with access to the robot operating system (ROS) to perform privilege escalation or cause denial-of-service.CVE-2020-10279 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10279"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-10280",
"cwe": {
"id": "CWE-239",
"name": "Failure to Handle Incomplete Element"
},
"notes": [
{
"category": "summary",
"text": "The Apache server on Port 80 hosting the web interface is vulnerable to a denial-of-service condition when an attacker spams incomplete HTTP headers, effectively blocking the access to the dashboard.CVE-2020-10280 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-10280"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "MiR recommends users upgrade affected products to the latest version. New software versions can be found on the MiR Distributor portal (login required).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.mobile-industrial-robots.com/en/sitetools/distributor-login/"
},
{
"category": "mitigation",
"details": "For more information, refer to MiR\u0027s security advisories page.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mobile-industrial-robots.com/en/about-mir/security-advisories/"
},
{
"category": "mitigation",
"details": "MiR instructs customers to explicitly change default credentials upon configuring the robots, including default SSID and password to the WiFi access point.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…