Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CERTFR-2025-AVI-0864
Vulnerability from certfr_avis - Published: 2025-10-13 - Updated: 2025-10-13
De multiples vulnérabilités ont été découvertes dans VMware Tanzu. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
Impacted products
References
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "VMWare Tanzu pour MySQL sur Kubernetes 2.0.0 toutes version",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2022-45061",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45061"
},
{
"name": "CVE-2022-3602",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3602"
},
{
"name": "CVE-2022-3786",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3786"
},
{
"name": "CVE-2022-3996",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3996"
},
{
"name": "CVE-2022-0391",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0391"
},
{
"name": "CVE-2022-1434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1434"
},
{
"name": "CVE-2022-1292",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1292"
},
{
"name": "CVE-2022-1343",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1343"
},
{
"name": "CVE-2022-1473",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1473"
},
{
"name": "CVE-2022-2068",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2068"
},
{
"name": "CVE-2022-2097",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2097"
},
{
"name": "CVE-2017-11164",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-11164"
},
{
"name": "CVE-2022-3358",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3358"
},
{
"name": "CVE-2021-4189",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-4189"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2022-4203",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4203"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2023-0401",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0401"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-0217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0217"
},
{
"name": "CVE-2023-0216",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0216"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2023-24329",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24329"
},
{
"name": "CVE-2023-0464",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0464"
},
{
"name": "CVE-2023-0466",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0466"
},
{
"name": "CVE-2023-0465",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0465"
},
{
"name": "CVE-2023-2650",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2650"
},
{
"name": "CVE-2023-1255",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1255"
},
{
"name": "CVE-2023-2975",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2975"
},
{
"name": "CVE-2023-3446",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3446"
},
{
"name": "CVE-2023-2953",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2953"
},
{
"name": "CVE-2023-3817",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3817"
},
{
"name": "CVE-2023-44487",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44487"
},
{
"name": "CVE-2023-22097",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22097"
},
{
"name": "CVE-2023-22084",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22084"
},
{
"name": "CVE-2023-22103",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22103"
},
{
"name": "CVE-2023-22068",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22068"
},
{
"name": "CVE-2023-22078",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22078"
},
{
"name": "CVE-2023-38546",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38546"
},
{
"name": "CVE-2023-22064",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22064"
},
{
"name": "CVE-2023-22059",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22059"
},
{
"name": "CVE-2023-22079",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22079"
},
{
"name": "CVE-2023-22066",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22066"
},
{
"name": "CVE-2023-22112",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22112"
},
{
"name": "CVE-2023-22092",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22092"
},
{
"name": "CVE-2023-22114",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22114"
},
{
"name": "CVE-2023-22070",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22070"
},
{
"name": "CVE-2023-22032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22032"
},
{
"name": "CVE-2023-5363",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5363"
},
{
"name": "CVE-2023-4807",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4807"
},
{
"name": "CVE-2023-5678",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5678"
},
{
"name": "CVE-2023-40217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40217"
},
{
"name": "CVE-2023-4813",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4813"
},
{
"name": "CVE-2023-4806",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4806"
},
{
"name": "CVE-2023-4039",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4039"
},
{
"name": "CVE-2023-5156",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5156"
},
{
"name": "CVE-2021-46848",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-46848"
},
{
"name": "CVE-2023-26604",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26604"
},
{
"name": "CVE-2023-4016",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4016"
},
{
"name": "CVE-2013-4235",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-4235"
},
{
"name": "CVE-2023-29383",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29383"
},
{
"name": "CVE-2023-5981",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5981"
},
{
"name": "CVE-2022-48560",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48560"
},
{
"name": "CVE-2023-48795",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-48795"
},
{
"name": "CVE-2023-6237",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6237"
},
{
"name": "CVE-2024-20970",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20970"
},
{
"name": "CVE-2024-20960",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20960"
},
{
"name": "CVE-2024-20983",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20983"
},
{
"name": "CVE-2024-20964",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20964"
},
{
"name": "CVE-2024-20963",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20963"
},
{
"name": "CVE-2024-20973",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20973"
},
{
"name": "CVE-2024-20961",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20961"
},
{
"name": "CVE-2024-20965",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20965"
},
{
"name": "CVE-2024-20967",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20967"
},
{
"name": "CVE-2024-20984",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20984"
},
{
"name": "CVE-2024-20976",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20976"
},
{
"name": "CVE-2024-20971",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20971"
},
{
"name": "CVE-2024-20966",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20966"
},
{
"name": "CVE-2024-20969",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20969"
},
{
"name": "CVE-2024-20981",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20981"
},
{
"name": "CVE-2024-20977",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20977"
},
{
"name": "CVE-2024-20962",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20962"
},
{
"name": "CVE-2024-20978",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20978"
},
{
"name": "CVE-2024-20982",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20982"
},
{
"name": "CVE-2024-20985",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20985"
},
{
"name": "CVE-2024-20972",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20972"
},
{
"name": "CVE-2024-20968",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20968"
},
{
"name": "CVE-2024-20974",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20974"
},
{
"name": "CVE-2023-39323",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39323"
},
{
"name": "CVE-2023-36054",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36054"
},
{
"name": "CVE-2023-7104",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-7104"
},
{
"name": "CVE-2023-6129",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6129"
},
{
"name": "CVE-2023-46218",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46218"
},
{
"name": "CVE-2024-0727",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-0727"
},
{
"name": "CVE-2023-47038",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-47038"
},
{
"name": "CVE-2023-39325",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39325"
},
{
"name": "CVE-2023-27043",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27043"
},
{
"name": "CVE-2022-48564",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48564"
},
{
"name": "CVE-2022-48565",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48565"
},
{
"name": "CVE-2024-28085",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-28085"
},
{
"name": "CVE-2024-2511",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2511"
},
{
"name": "CVE-2016-2781",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-2781"
},
{
"name": "CVE-2024-0553",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-0553"
},
{
"name": "CVE-2023-6597",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6597"
},
{
"name": "CVE-2024-21055",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21055"
},
{
"name": "CVE-2024-21000",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21000"
},
{
"name": "CVE-2024-21050",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21050"
},
{
"name": "CVE-2024-21015",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21015"
},
{
"name": "CVE-2024-20994",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20994"
},
{
"name": "CVE-2024-21056",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21056"
},
{
"name": "CVE-2024-21047",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21047"
},
{
"name": "CVE-2024-21051",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21051"
},
{
"name": "CVE-2024-21057",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21057"
},
{
"name": "CVE-2024-20998",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20998"
},
{
"name": "CVE-2024-21069",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21069"
},
{
"name": "CVE-2024-21013",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21013"
},
{
"name": "CVE-2024-21009",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21009"
},
{
"name": "CVE-2024-21096",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21096"
},
{
"name": "CVE-2024-21054",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21054"
},
{
"name": "CVE-2024-21008",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21008"
},
{
"name": "CVE-2024-21060",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21060"
},
{
"name": "CVE-2024-21052",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21052"
},
{
"name": "CVE-2024-21053",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21053"
},
{
"name": "CVE-2024-21062",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21062"
},
{
"name": "CVE-2024-21049",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21049"
},
{
"name": "CVE-2024-21061",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21061"
},
{
"name": "CVE-2024-21102",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21102"
},
{
"name": "CVE-2024-20993",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20993"
},
{
"name": "CVE-2024-21087",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21087"
},
{
"name": "CVE-2023-39326",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39326"
},
{
"name": "CVE-2023-45285",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45285"
},
{
"name": "CVE-2024-28182",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-28182"
},
{
"name": "CVE-2023-45288",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45288"
},
{
"name": "CVE-2024-4603",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-4603"
},
{
"name": "CVE-2023-45289",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45289"
},
{
"name": "CVE-2023-45290",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45290"
},
{
"name": "CVE-2024-24783",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24783"
},
{
"name": "CVE-2024-24784",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24784"
},
{
"name": "CVE-2024-24785",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24785"
},
{
"name": "CVE-2024-4741",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-4741"
},
{
"name": "CVE-2016-20013",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-20013"
},
{
"name": "CVE-2024-5535",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5535"
},
{
"name": "CVE-2024-2398",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2398"
},
{
"name": "CVE-2024-4032",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-4032"
},
{
"name": "CVE-2024-5642",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5642"
},
{
"name": "CVE-2024-3596",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-3596"
},
{
"name": "CVE-2023-6004",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6004"
},
{
"name": "CVE-2023-6918",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6918"
},
{
"name": "CVE-2024-0450",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-0450"
},
{
"name": "CVE-2024-26458",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26458"
},
{
"name": "CVE-2024-26461",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26461"
},
{
"name": "CVE-2024-28834",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-28834"
},
{
"name": "CVE-2024-2961",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2961"
},
{
"name": "CVE-2024-33599",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-33599"
},
{
"name": "CVE-2024-33600",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-33600"
},
{
"name": "CVE-2024-33601",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-33601"
},
{
"name": "CVE-2024-33602",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-33602"
},
{
"name": "CVE-2023-39804",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39804"
},
{
"name": "CVE-2023-4641",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4641"
},
{
"name": "CVE-2024-22365",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-22365"
},
{
"name": "CVE-2024-20996",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-20996"
},
{
"name": "CVE-2024-21125",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21125"
},
{
"name": "CVE-2024-21127",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21127"
},
{
"name": "CVE-2024-21129",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21129"
},
{
"name": "CVE-2024-21130",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21130"
},
{
"name": "CVE-2024-21134",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21134"
},
{
"name": "CVE-2024-21135",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21135"
},
{
"name": "CVE-2024-21137",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21137"
},
{
"name": "CVE-2024-21142",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21142"
},
{
"name": "CVE-2024-21157",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21157"
},
{
"name": "CVE-2024-21159",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21159"
},
{
"name": "CVE-2024-21160",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21160"
},
{
"name": "CVE-2024-21162",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21162"
},
{
"name": "CVE-2024-21163",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21163"
},
{
"name": "CVE-2024-21165",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21165"
},
{
"name": "CVE-2024-21166",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21166"
},
{
"name": "CVE-2024-21171",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21171"
},
{
"name": "CVE-2024-21173",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21173"
},
{
"name": "CVE-2024-21177",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21177"
},
{
"name": "CVE-2024-21179",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21179"
},
{
"name": "CVE-2024-21185",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21185"
},
{
"name": "CVE-2024-6923",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-6923"
},
{
"name": "CVE-2024-24787",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24787"
},
{
"name": "CVE-2022-40735",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40735"
},
{
"name": "CVE-2023-7008",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-7008"
},
{
"name": "CVE-2024-6232",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-6232"
},
{
"name": "CVE-2024-6119",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-6119"
},
{
"name": "CVE-2024-45491",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-45491"
},
{
"name": "CVE-2024-45492",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-45492"
},
{
"name": "CVE-2024-8096",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8096"
},
{
"name": "CVE-2024-24789",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24789"
},
{
"name": "CVE-2024-34155",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-34155"
},
{
"name": "CVE-2024-34156",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-34156"
},
{
"name": "CVE-2024-34158",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-34158"
},
{
"name": "CVE-2024-24790",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24790"
},
{
"name": "CVE-2024-21193",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21193"
},
{
"name": "CVE-2024-21194",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21194"
},
{
"name": "CVE-2024-21196",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21196"
},
{
"name": "CVE-2024-21197",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21197"
},
{
"name": "CVE-2024-21198",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21198"
},
{
"name": "CVE-2024-21199",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21199"
},
{
"name": "CVE-2024-21200",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21200"
},
{
"name": "CVE-2024-21201",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21201"
},
{
"name": "CVE-2024-21207",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21207"
},
{
"name": "CVE-2024-21212",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21212"
},
{
"name": "CVE-2024-21213",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21213"
},
{
"name": "CVE-2024-21219",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21219"
},
{
"name": "CVE-2024-21230",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21230"
},
{
"name": "CVE-2024-21231",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21231"
},
{
"name": "CVE-2024-21236",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21236"
},
{
"name": "CVE-2024-21237",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21237"
},
{
"name": "CVE-2024-21239",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21239"
},
{
"name": "CVE-2024-21241",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-21241"
},
{
"name": "CVE-2024-37370",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37370"
},
{
"name": "CVE-2024-37371",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37371"
},
{
"name": "CVE-2024-9143",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9143"
},
{
"name": "CVE-2024-45490",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-45490"
},
{
"name": "CVE-2024-8088",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8088"
},
{
"name": "CVE-2024-11168",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11168"
},
{
"name": "CVE-2024-10041",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-10041"
},
{
"name": "CVE-2024-12085",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12085"
},
{
"name": "CVE-2024-12087",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12087"
},
{
"name": "CVE-2024-12088",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12088"
},
{
"name": "CVE-2024-12747",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12747"
},
{
"name": "CVE-2025-21490",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21490"
},
{
"name": "CVE-2025-21491",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21491"
},
{
"name": "CVE-2025-21492",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21492"
},
{
"name": "CVE-2025-21494",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21494"
},
{
"name": "CVE-2025-21497",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21497"
},
{
"name": "CVE-2025-21500",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21500"
},
{
"name": "CVE-2025-21501",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21501"
},
{
"name": "CVE-2025-21503",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21503"
},
{
"name": "CVE-2025-21504",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21504"
},
{
"name": "CVE-2025-21505",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21505"
},
{
"name": "CVE-2025-21518",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21518"
},
{
"name": "CVE-2025-21519",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21519"
},
{
"name": "CVE-2025-21521",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21521"
},
{
"name": "CVE-2025-21522",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21522"
},
{
"name": "CVE-2025-21523",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21523"
},
{
"name": "CVE-2025-21525",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21525"
},
{
"name": "CVE-2025-21529",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21529"
},
{
"name": "CVE-2025-21534",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21534"
},
{
"name": "CVE-2025-21536",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21536"
},
{
"name": "CVE-2025-21540",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21540"
},
{
"name": "CVE-2025-21546",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21546"
},
{
"name": "CVE-2025-21555",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21555"
},
{
"name": "CVE-2025-21559",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21559"
},
{
"name": "CVE-2025-0938",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-0938"
},
{
"name": "CVE-2024-50602",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-50602"
},
{
"name": "CVE-2022-48566",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48566"
},
{
"name": "CVE-2024-24791",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-24791"
},
{
"name": "CVE-2024-45336",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-45336"
},
{
"name": "CVE-2024-45341",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-45341"
},
{
"name": "CVE-2025-22866",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-22866"
},
{
"name": "CVE-2025-21574",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21574"
},
{
"name": "CVE-2025-21575",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21575"
},
{
"name": "CVE-2025-21577",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21577"
},
{
"name": "CVE-2025-21579",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21579"
},
{
"name": "CVE-2025-21580",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21580"
},
{
"name": "CVE-2025-21581",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21581"
},
{
"name": "CVE-2025-21584",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21584"
},
{
"name": "CVE-2025-21585",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-21585"
},
{
"name": "CVE-2025-30681",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30681"
},
{
"name": "CVE-2025-30682",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30682"
},
{
"name": "CVE-2025-30683",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30683"
},
{
"name": "CVE-2025-30684",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30684"
},
{
"name": "CVE-2025-30685",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30685"
},
{
"name": "CVE-2025-30687",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30687"
},
{
"name": "CVE-2025-30688",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30688"
},
{
"name": "CVE-2025-30689",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30689"
},
{
"name": "CVE-2025-30693",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30693"
},
{
"name": "CVE-2025-30695",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30695"
},
{
"name": "CVE-2025-30696",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30696"
},
{
"name": "CVE-2025-30699",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30699"
},
{
"name": "CVE-2025-30703",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30703"
},
{
"name": "CVE-2025-30704",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30704"
},
{
"name": "CVE-2025-30705",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30705"
},
{
"name": "CVE-2025-30715",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30715"
},
{
"name": "CVE-2025-30721",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30721"
},
{
"name": "CVE-2025-30722",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30722"
},
{
"name": "CVE-2025-22871",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-22871"
},
{
"name": "CVE-2024-9287",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9287"
},
{
"name": "CVE-2023-45918",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45918"
},
{
"name": "CVE-2024-12133",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12133"
},
{
"name": "CVE-2024-12243",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12243"
},
{
"name": "CVE-2024-2236",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2236"
},
{
"name": "CVE-2025-0395",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-0395"
},
{
"name": "CVE-2025-29088",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-29088"
},
{
"name": "CVE-2025-24528",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-24528"
},
{
"name": "CVE-2025-4802",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-4802"
},
{
"name": "CVE-2025-3576",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-3576"
},
{
"name": "CVE-2025-4673",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-4673"
},
{
"name": "CVE-2025-27587",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-27587"
},
{
"name": "CVE-2025-40909",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-40909"
}
],
"initial_release_date": "2025-10-13T00:00:00",
"last_revision_date": "2025-10-13T00:00:00",
"links": [],
"reference": "CERTFR-2025-AVI-0864",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-10-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Injection SQL (SQLi)"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Falsification de requ\u00eates c\u00f4t\u00e9 serveur (SSRF)"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans VMware Tanzu. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans VMware Tanzu",
"vendor_advisories": [
{
"published_at": "2025-10-10",
"title": "Bulletin de s\u00e9curit\u00e9 VMware 36208",
"url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36208"
}
]
}
CVE-2024-34155 (GCVE-0-2024-34155)
Vulnerability from cvelistv5 – Published: 2024-09-06 20:42 – Updated: 2024-11-04 16:59
VLAI
EPSS
Title
Stack exhaustion in all Parse functions in go/parser
Summary
Calling any of the Parse functions on Go source code which contains deeply nested literals can cause a panic due to stack exhaustion.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-674 - Uncontrolled Recursion
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Go standard library | go/parser |
Affected:
0 , < 1.22.7
(semver)
Affected: 1.23.0-0 , < 1.23.1 (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-34155",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T13:55:36.320331Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-04T16:59:31.685Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-09-26T15:03:07.202Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20240926-0005/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://pkg.go.dev",
"defaultStatus": "unaffected",
"packageName": "go/parser",
"product": "go/parser",
"programRoutines": [
{
"name": "parser.parseLiteralValue"
},
{
"name": "ParseDir"
},
{
"name": "ParseExpr"
},
{
"name": "ParseExprFrom"
},
{
"name": "ParseFile"
}
],
"vendor": "Go standard library",
"versions": [
{
"lessThan": "1.22.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.1",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Calling any of the Parse functions on Go source code which contains deeply nested literals can cause a panic due to stack exhaustion."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-674: Uncontrolled Recursion",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-06T20:42:42.518Z",
"orgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"shortName": "Go"
},
"references": [
{
"url": "https://go.dev/cl/611238"
},
{
"url": "https://go.dev/issue/69138"
},
{
"url": "https://groups.google.com/g/golang-dev/c/S9POB9NCTdk"
},
{
"url": "https://pkg.go.dev/vuln/GO-2024-3105"
}
],
"title": "Stack exhaustion in all Parse functions in go/parser"
}
},
"cveMetadata": {
"assignerOrgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"assignerShortName": "Go",
"cveId": "CVE-2024-34155",
"datePublished": "2024-09-06T20:42:42.518Z",
"dateReserved": "2024-05-01T18:45:34.846Z",
"dateUpdated": "2024-11-04T16:59:31.685Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34156 (GCVE-0-2024-34156)
Vulnerability from cvelistv5 – Published: 2024-09-06 20:42 – Updated: 2024-09-26 15:03
VLAI
EPSS
Title
Stack exhaustion in Decoder.Decode in encoding/gob
Summary
Calling Decoder.Decode on a message which contains deeply nested structures can cause a panic due to stack exhaustion. This is a follow-up to CVE-2022-30635.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-674 - Uncontrolled Recursion
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Go standard library | encoding/gob |
Affected:
0 , < 1.22.7
(semver)
Affected: 1.23.0-0 , < 1.23.1 (semver) |
|
| go_standard_library | encoding\/gob |
Affected:
0 , < 1.22.7
(semver)
Affected: 1.23.0-0 , < 1.23.1 (semver) cpe:2.3:a:go_standard_library:encoding\/gob:*:*:*:*:*:*:*:* |
Credits
Md Sakib Anwar of The Ohio State University (anwar.40@osu.edu)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:go_standard_library:encoding\\/gob:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "encoding\\/gob",
"vendor": "go_standard_library",
"versions": [
{
"lessThan": "1.22.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.1",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-34156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T14:04:16.338747Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T14:29:46.867Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-09-26T15:03:08.203Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20240926-0004/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://pkg.go.dev",
"defaultStatus": "unaffected",
"packageName": "encoding/gob",
"product": "encoding/gob",
"programRoutines": [
{
"name": "Decoder.decIgnoreOpFor"
},
{
"name": "Decoder.Decode"
},
{
"name": "Decoder.DecodeValue"
}
],
"vendor": "Go standard library",
"versions": [
{
"lessThan": "1.22.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.1",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Md Sakib Anwar of The Ohio State University (anwar.40@osu.edu)"
}
],
"descriptions": [
{
"lang": "en",
"value": "Calling Decoder.Decode on a message which contains deeply nested structures can cause a panic due to stack exhaustion. This is a follow-up to CVE-2022-30635."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-674: Uncontrolled Recursion",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-06T20:42:42.661Z",
"orgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"shortName": "Go"
},
"references": [
{
"url": "https://go.dev/cl/611239"
},
{
"url": "https://go.dev/issue/69139"
},
{
"url": "https://groups.google.com/g/golang-dev/c/S9POB9NCTdk"
},
{
"url": "https://pkg.go.dev/vuln/GO-2024-3106"
}
],
"title": "Stack exhaustion in Decoder.Decode in encoding/gob"
}
},
"cveMetadata": {
"assignerOrgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"assignerShortName": "Go",
"cveId": "CVE-2024-34156",
"datePublished": "2024-09-06T20:42:42.661Z",
"dateReserved": "2024-05-01T18:45:34.846Z",
"dateUpdated": "2024-09-26T15:03:08.203Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34158 (GCVE-0-2024-34158)
Vulnerability from cvelistv5 – Published: 2024-09-06 20:42 – Updated: 2024-10-04 15:02
VLAI
EPSS
Title
Stack exhaustion in Parse in go/build/constraint
Summary
Calling Parse on a "// +build" build tag line with deeply nested expressions can cause a panic due to stack exhaustion.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-674 - Uncontrolled Recursion
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Go standard library | go/build/constraint |
Affected:
0 , < 1.22.7
(semver)
Affected: 1.23.0-0 , < 1.23.1 (semver) |
|
| go_build_constraint | go_standard_library |
Affected:
0 , < 1.22.7
(semver)
Affected: 1.23.0-0 , < 1.23.1 (semver) cpe:2.3:a:go_build_constraint:go_standard_library:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:go_build_constraint:go_standard_library:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "go_standard_library",
"vendor": "go_build_constraint",
"versions": [
{
"lessThan": "1.22.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.1",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-34158",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T13:59:30.881339Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-674",
"description": "CWE-674 Uncontrolled Recursion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T14:04:26.919Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-04T15:02:47.715Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20241004-0003/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://pkg.go.dev",
"defaultStatus": "unaffected",
"packageName": "go/build/constraint",
"product": "go/build/constraint",
"programRoutines": [
{
"name": "parsePlusBuildExpr"
},
{
"name": "exprParser.not"
},
{
"name": "Parse"
}
],
"vendor": "Go standard library",
"versions": [
{
"lessThan": "1.22.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.1",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Calling Parse on a \"// +build\" build tag line with deeply nested expressions can cause a panic due to stack exhaustion."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-674: Uncontrolled Recursion",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-06T20:42:42.822Z",
"orgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"shortName": "Go"
},
"references": [
{
"url": "https://go.dev/cl/611240"
},
{
"url": "https://go.dev/issue/69141"
},
{
"url": "https://groups.google.com/g/golang-dev/c/S9POB9NCTdk"
},
{
"url": "https://pkg.go.dev/vuln/GO-2024-3107"
}
],
"title": "Stack exhaustion in Parse in go/build/constraint"
}
},
"cveMetadata": {
"assignerOrgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"assignerShortName": "Go",
"cveId": "CVE-2024-34158",
"datePublished": "2024-09-06T20:42:42.822Z",
"dateReserved": "2024-05-01T18:45:34.846Z",
"dateUpdated": "2024-10-04T15:02:47.715Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3596 (GCVE-0-2024-3596)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:02 – Updated: 2026-06-09 09:01
VLAI
EPSS
Title
RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
13 references
Impacted products
478 products
| Vendor | Product | Version | |
|---|---|---|---|
| IETF | RFC |
Affected:
2865
|
|
| ietf | rfc |
Affected:
2865
cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:* |
|
| Siemens | CPC80 Central Processing/Communication |
Affected:
0 , < V16.51
(custom)
|
|
| Siemens | CPCI85 Central Processing/Communication |
Affected:
0 , < V6.20
(custom)
|
|
| Siemens | POWER METER SICAM Q100 family |
Affected:
0 , < V2.70
(custom)
|
|
| Siemens | POWER METER SICAM Q200 family |
Affected:
0 , < V2.83
(custom)
|
|
| Siemens | Powerlink IP |
Affected:
0 , < V4.22
(custom)
|
|
| Siemens | RUGGEDCOM APE1808 |
Affected:
0 , < *
(custom)
|
|
| Siemens | RUGGEDCOM CROSSBOW |
Affected:
0 , < V5.6
(custom)
|
|
| Siemens | RUGGEDCOM i800 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i800NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i801 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i801NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i802 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i802NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i803 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM i803NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2100 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2100NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2200 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M2200NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M969 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM M969NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | RUGGEDCOM RMC30 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC30NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX MX5000RE |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1400 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1500 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1501 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1510 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1511 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1512 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1524 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX1536 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM ROX RX5000 |
Affected:
0 , < V2.17.0
(custom)
|
|
| Siemens | RUGGEDCOM RP110 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RP110NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600F |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600FNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600T |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS1600TNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS400 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS400NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS401 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS401NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NCv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416NCv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416P |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNCv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416PNCv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS8000 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000A |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000ANC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000H |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000HNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000T |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS8000TNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900G |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GNC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GP |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900GPNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-GETS-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-GETS-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-STND-XX |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900MNC-STND-XX-C01 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS900NC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS910W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS920W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930L |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930LNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS930W |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS940G |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS940GNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS969 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RS969NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC(32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100NC(32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC (32M) V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100PNC (32M) V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200 |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200NC |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300PNC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300PNC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488NC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488NC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG907R |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG908C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG909R |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG910C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920PNC V4.X |
Affected:
0 , < V4.3.11
(custom)
|
|
| Siemens | RUGGEDCOM RSG920PNC V5.X |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910 |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910NC |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228 |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228P |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2428P |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | RUGGEDCOM RST916C |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | RUGGEDCOM RST916P |
Affected:
0 , < V5.10.0
(custom)
|
|
| Siemens | SCALANCE M804PB |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M812-1 ADSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M816-1 ADSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M826-2 SHDSL-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-2 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-3 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M874-3 3G-Router (CN) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-3 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-3 (ROK) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (NAM) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (A1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (B1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (A1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (B1) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (CN) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (EU) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (RoW) |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE S615 EEC LAN-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE S615 LAN-Router |
Affected:
0 , < V8.2
(custom)
|
|
| Siemens | SCALANCE SC622-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC626-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC632-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC636-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC642-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE SC646-2C |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 EEC M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2IA M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE WAB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUB762-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUB762-1 iFeatures |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 (US) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (ME) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (USA) |
Affected:
0 , < V3.0.0
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X302-7 EEC (2x 24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X304-2FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X306-1LD FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 230V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-2 EEC (2x 24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-3 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X307-3LD |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LD |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LH |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2LH+ |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M PoE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X308-2M TS |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X310 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X310FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X320-1 FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X320-1-2LD FE |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE X408-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XB205-3 (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 (SC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 (ST/BFOC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 LD |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 SC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2 ST |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB206-2LD |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB208 (E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB208 (PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB216 (E/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XB216 (PN) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2 (SC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2 (ST/BFOC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE EEC (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G (EIP DEF.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G (EIP def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC208G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE (54 V DC) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G (EIP Def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216-4C G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC216EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G (EIP Def.) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC224-4C G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XC316-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC324-4 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC324-4 EEC |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC332 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC416-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC424-4 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XC432 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XCH328 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM324 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM328 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XCM332 |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XF204 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204 DNA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204-2BA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204-2BA DNA |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XF204G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XM408-4C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-4C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-8C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM408-8C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM416-4C |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XM416-4C (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XP208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208 (Ethernet/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208G PP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP208PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 (Ethernet/IP) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216 (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216EEC (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216G PoE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216POE EEC |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XP216PoE EEC (V2) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR302-32 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR322-12 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR324-12M (230V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (230V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-12M TS (24V) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE (24V, ports on rear) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324-4M PoE TS (24V, ports on front) |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 x FE, AC 230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 X FE, DC 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG (without UL) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR326-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR326-8 EEC |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, AC 230V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, DC 24V) |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SCALANCE XR502-32 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR522-12 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR524-8WG |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR526-8 |
Affected:
0 , < V1.3
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2, L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR528-6M (L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2, L3 int.) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XRH334 (24 V DC, 8xFO, CC) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230 V AC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230 V AC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24 V DC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24 V DC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230 V AC, 12xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230 V AC, 8xFO) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) |
Affected:
0 , < V3.2
(custom)
|
|
| Siemens | SICAM AK 3 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM BC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridEdge (Classic) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridEdge Applications for SICAM 8 Platform |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICAM GridPass |
Affected:
0 , < V2.50
(custom)
|
|
| Siemens | SICAM TM |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICORE Base system |
Affected:
0 , < V2.20.0
(custom)
|
|
| Siemens | SINEC INS |
Affected:
0 , < V1.0 SP2 Update 4
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE X308-2 |
Affected:
0 , < V4.1.9
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2SFP |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC208 |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC216-4C |
Affected:
0 , < V4.6
(custom)
|
|
| Siemens | SIPROTEC 5 - CP200 Devices |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD84 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) V9.6x |
Affected:
0 , < V9.68
(custom)
|
|
| Siemens | SIPROTEC 5 6MU85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) V9.6x |
Affected:
0 , < V9.68
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) V9.8x |
Affected:
0 , < V9.83
(custom)
|
|
| Siemens | SIPROTEC 5 7SX82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SX85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SY82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UM85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP100) |
Affected:
V7.80 , < V8.90
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP150) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VE85 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP300) |
Affected:
V7.80 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VU85 (CP300) |
Affected:
0 , < V10.0
(custom)
|
|
| Siemens | SIPROTEC 5 Compact 7SX800 (CP050) |
Affected:
0 , < V10.0
(custom)
|
Credits
Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rfc",
"vendor": "ietf",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T03:55:37.141738Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-04T21:05:25.373Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:20:52.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
},
{
"url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"tags": [
"x_transferred"
],
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"tags": [
"x_transferred"
],
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.blastradius.fail/"
},
{
"tags": [
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"url": "https://www.kb.cert.org/vuls/id/456537"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "CPC80 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.51",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "CPCI85 Central Processing/Communication",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q200 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Powerlink IP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.22",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM CROSSBOW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX MX5000RE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600F",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600FNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416NCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416PNCv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000ANC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000H",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000HNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000TNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GNC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GPNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900MNC-STND-XX-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930LNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940GNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100NC(32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488NC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG907R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG908C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG909R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG910C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920PNC V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910NC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2428P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3 3G-Router (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (A1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (B1)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (CN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X304-2FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X306-1LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1 FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1-2LD FE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 SC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2 ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB206-2LD",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC316-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC324-4 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC416-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC424-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC432",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCH328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM324",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM328",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM332",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208G PP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216G PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216PoE EEC (V2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR302-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR322-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-8 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR502-32",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR522-12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRH334 (24 V DC, 8xFO, CC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24 V DC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 12xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230 V AC, 8xFO)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM AK 3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM BC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge (Classic)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridEdge Applications for SICAM 8 Platform",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM GridPass",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM TM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICORE Base system",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.20.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC INS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0 SP2 Update 4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 - CP200 Devices",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300) V9.8x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.90",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V7.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-09T09:01:52.617Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-364175.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-770770.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "RFC",
"vendor": "IETF",
"versions": [
{
"status": "affected",
"version": "2865"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability"
}
],
"descriptions": [
{
"lang": "en",
"value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-328: Use of Weak Hash",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-03T17:29:16.788Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://datatracker.ietf.org/doc/html/rfc2865"
},
{
"url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
},
{
"url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
},
{
"url": "https://www.blastradius.fail/"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT for SIPROTEC, SICAM and related product",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794185.html"
},
{
"name": "Siemens Security Advisory by Siemens ProductCERT to SCALANCE, RUGGEDCOM and related products.",
"tags": [
"vendor-advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-723487.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.",
"x_generator": {
"engine": "VINCE 3.0.4",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2024-3596"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2024-3596",
"datePublished": "2024-07-09T12:02:53.001Z",
"dateReserved": "2024-04-10T15:09:45.391Z",
"dateUpdated": "2026-06-09T09:01:52.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-37370 (GCVE-0-2024-37370)
Vulnerability from cvelistv5 – Published: 2024-06-28 00:00 – Updated: 2026-05-12 11:54
VLAI
EPSS
Summary
In MIT Kerberos 5 (aka krb5) before 1.21.3, an attacker can modify the plaintext Extra Count field of a confidential GSS krb5 wrap token, causing the unwrapped token to appear truncated to the application.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37370",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-01T15:25:49.407050Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-18T15:49:01.684Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-11-08T15:02:50.736Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://web.mit.edu/kerberos/www/advisories/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/krb5/krb5/commit/55fbf435edbe2e92dd8101669b1ce7144bc96fef"
},
{
"url": "https://security.netapp.com/advisory/ntap-20241108-0007/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T11:54:31.271Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-082556.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In MIT Kerberos 5 (aka krb5) before 1.21.3, an attacker can modify the plaintext Extra Count field of a confidential GSS krb5 wrap token, causing the unwrapped token to appear truncated to the application."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T22:04:28.292Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://web.mit.edu/kerberos/www/advisories/"
},
{
"url": "https://github.com/krb5/krb5/commit/55fbf435edbe2e92dd8101669b1ce7144bc96fef"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37370",
"datePublished": "2024-06-28T00:00:00.000Z",
"dateReserved": "2024-06-06T00:00:00.000Z",
"dateUpdated": "2026-05-12T11:54:31.271Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-37371 (GCVE-0-2024-37371)
Vulnerability from cvelistv5 – Published: 2024-06-28 00:00 – Updated: 2026-05-12 11:54
VLAI
EPSS
Summary
In MIT Kerberos 5 (aka krb5) before 1.21.3, an attacker can cause invalid memory reads during GSS message token handling by sending message tokens with invalid length fields.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37371",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T15:31:33.769366Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T20:28:07.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:38:01.079Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://web.mit.edu/kerberos/www/advisories/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/krb5/krb5/commit/55fbf435edbe2e92dd8101669b1ce7144bc96fef"
},
{
"url": "https://security.netapp.com/advisory/ntap-20241108-0009/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20250124-0010/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T11:54:32.455Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-082556.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In MIT Kerberos 5 (aka krb5) before 1.21.3, an attacker can cause invalid memory reads during GSS message token handling by sending message tokens with invalid length fields."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T22:06:30.396Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://web.mit.edu/kerberos/www/advisories/"
},
{
"url": "https://github.com/krb5/krb5/commit/55fbf435edbe2e92dd8101669b1ce7144bc96fef"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37371",
"datePublished": "2024-06-28T00:00:00.000Z",
"dateReserved": "2024-06-06T00:00:00.000Z",
"dateUpdated": "2026-05-12T11:54:32.455Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-4032 (GCVE-0-2024-4032)
Vulnerability from cvelistv5 – Published: 2024-06-17 15:05 – Updated: 2025-11-03 21:57
VLAI
EPSS
Title
Incorrect IPv4 and IPv6 private ranges
Summary
The “ipaddress” module contained incorrect information about whether certain IPv4 and IPv6 addresses were designated as “globally reachable” or “private”. This affected the is_private and is_global properties of the ipaddress.IPv4Address, ipaddress.IPv4Network, ipaddress.IPv6Address, and ipaddress.IPv6Network classes, where values wouldn’t be returned in accordance with the latest information from the IANA Special-Purpose Address Registries.
CPython 3.12.4 and 3.13.0a6 contain updated information from these registries and thus have the intended behavior.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-697 - Incorrect Comparison
Assigner
References
14 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Python Software Foundation | CPython |
Affected:
0 , < 3.8.20
(python)
Affected: 3.9.0 , < 3.9.20 (python) Affected: 3.10.0 , < 3.10.15 (python) Affected: 3.11.0 , < 3.11.10 (python) Affected: 3.12.0 , < 3.12.4 (python) Affected: 3.13.0a1 , < 3.13.0a6 (python) |
|
| python | cpython |
Affected:
0 , < 3.12.4
(custom)
Affected: 3.13.0a1 , < 3.13.0a6 (custom) cpe:2.3:a:python:cpython:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:57:16.975Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://github.com/python/cpython/issues/113171"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/pull/113179"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.iana.org/assignments/iana-ipv4-special-registry/iana-ipv4-special-registry.xhtml"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.iana.org/assignments/iana-ipv6-special-registry/iana-ipv6-special-registry.xhtml"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://mail.python.org/archives/list/security-announce@python.org/thread/NRUHDUS2IV2USIZM2CVMSFL6SCKU3RZA/"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/commit/22adf29da8d99933ffed8647d3e0726edd16f7f8"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/commit/40d75c2b7f5c67e254d0a025e0f2e2c7ada7f69f"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/commit/895f7e2ac23eff4743143beef0f0c5ac71ea27d3"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/commit/ba431579efdcbaed7a96f2ac4ea0775879a332fb"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/commit/c62c9e518b784fe44432a3f4fc265fb95b651906"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/python/cpython/commit/f86b17ac511e68192ba71f27e752321a3252cee3"
},
{
"tags": [
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2024/06/17/3"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240726-0004/"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/12/msg00000.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:python:cpython:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cpython",
"vendor": "python",
"versions": [
{
"lessThan": "3.12.4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "3.13.0a6",
"status": "affected",
"version": "3.13.0a1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-4032",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-08T18:21:11.207929Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-697",
"description": "CWE-697 Incorrect Comparison",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-17T15:55:55.506Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CPython",
"repo": "https://github.com/python/cpython",
"vendor": "Python Software Foundation",
"versions": [
{
"lessThan": "3.8.20",
"status": "affected",
"version": "0",
"versionType": "python"
},
{
"lessThan": "3.9.20",
"status": "affected",
"version": "3.9.0",
"versionType": "python"
},
{
"lessThan": "3.10.15",
"status": "affected",
"version": "3.10.0",
"versionType": "python"
},
{
"lessThan": "3.11.10",
"status": "affected",
"version": "3.11.0",
"versionType": "python"
},
{
"lessThan": "3.12.4",
"status": "affected",
"version": "3.12.0",
"versionType": "python"
},
{
"lessThan": "3.13.0a6",
"status": "affected",
"version": "3.13.0a1",
"versionType": "python"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eThe \u201cipaddress\u201d module contained incorrect information about whether certain IPv4 and IPv6 addresses were designated as \u201cglobally reachable\u201d or \u201cprivate\u201d. This affected the is_private and is_global properties of the ipaddress.IPv4Address, ipaddress.IPv4Network, ipaddress.IPv6Address, and ipaddress.IPv6Network classes, where values wouldn\u2019t be returned in accordance with the latest information from the IANA Special-Purpose Address Registries.\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eCPython 3.12.4 and 3.13.0a6 contain updated information from these registries and thus have the intended behavior.\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "The \u201cipaddress\u201d module contained incorrect information about whether certain IPv4 and IPv6 addresses were designated as \u201cglobally reachable\u201d or \u201cprivate\u201d. This affected the is_private and is_global properties of the ipaddress.IPv4Address, ipaddress.IPv4Network, ipaddress.IPv6Address, and ipaddress.IPv6Network classes, where values wouldn\u2019t be returned in accordance with the latest information from the IANA Special-Purpose Address Registries.\n\nCPython 3.12.4 and 3.13.0a6 contain updated information from these registries and thus have the intended behavior."
}
],
"providerMetadata": {
"dateUpdated": "2024-09-07T02:44:42.321Z",
"orgId": "28c92f92-d60d-412d-b760-e73465c3df22",
"shortName": "PSF"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://github.com/python/cpython/issues/113171"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/pull/113179"
},
{
"url": "https://www.iana.org/assignments/iana-ipv4-special-registry/iana-ipv4-special-registry.xhtml"
},
{
"url": "https://www.iana.org/assignments/iana-ipv6-special-registry/iana-ipv6-special-registry.xhtml"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://mail.python.org/archives/list/security-announce@python.org/thread/NRUHDUS2IV2USIZM2CVMSFL6SCKU3RZA/"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/commit/22adf29da8d99933ffed8647d3e0726edd16f7f8"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/commit/40d75c2b7f5c67e254d0a025e0f2e2c7ada7f69f"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/commit/895f7e2ac23eff4743143beef0f0c5ac71ea27d3"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/commit/ba431579efdcbaed7a96f2ac4ea0775879a332fb"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/commit/c62c9e518b784fe44432a3f4fc265fb95b651906"
},
{
"tags": [
"patch"
],
"url": "https://github.com/python/cpython/commit/f86b17ac511e68192ba71f27e752321a3252cee3"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/06/17/3"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240726-0004/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Incorrect IPv4 and IPv6 private ranges",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "28c92f92-d60d-412d-b760-e73465c3df22",
"assignerShortName": "PSF",
"cveId": "CVE-2024-4032",
"datePublished": "2024-06-17T15:05:58.827Z",
"dateReserved": "2024-04-22T17:15:47.895Z",
"dateUpdated": "2025-11-03T21:57:16.975Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45336 (GCVE-0-2024-45336)
Vulnerability from cvelistv5 – Published: 2025-01-28 01:03 – Updated: 2025-09-18 18:41
VLAI
EPSS
Title
Sensitive headers incorrectly sent after cross-domain redirect in net/http
Summary
The HTTP client drops sensitive headers after following a cross-domain redirect. For example, a request to a.com/ containing an Authorization header which is redirected to b.com/ will not send that header to b.com. In the event that the client received a subsequent same-domain redirect, however, the sensitive headers would be restored. For example, a chain of redirects from a.com/, to b.com/1, and finally to b.com/2 would incorrectly send the Authorization header to b.com/2.
Severity
6.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-201 - Insertion of Sensitive Information Into Sent Data
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Go standard library | net/http |
Affected:
0 , < 1.22.11
(semver)
Affected: 1.23.0-0 , < 1.23.5 (semver) Affected: 1.24.0-0 , < 1.24.0-rc.2 (semver) |
Credits
Kyle Seely
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-45336",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T14:56:59.058895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T15:16:38.044Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-02-21T18:03:31.299Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20250221-0003/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://pkg.go.dev",
"defaultStatus": "unaffected",
"packageName": "net/http",
"product": "net/http",
"programRoutines": [
{
"name": "Client.do"
},
{
"name": "Client.makeHeadersCopier"
},
{
"name": "shouldCopyHeaderOnRedirect"
},
{
"name": "Client.Do"
},
{
"name": "Client.Get"
},
{
"name": "Client.Head"
},
{
"name": "Client.Post"
},
{
"name": "Client.PostForm"
},
{
"name": "Get"
},
{
"name": "Head"
},
{
"name": "Post"
},
{
"name": "PostForm"
}
],
"vendor": "Go standard library",
"versions": [
{
"lessThan": "1.22.11",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.5",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
},
{
"lessThan": "1.24.0-rc.2",
"status": "affected",
"version": "1.24.0-0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Kyle Seely"
}
],
"descriptions": [
{
"lang": "en",
"value": "The HTTP client drops sensitive headers after following a cross-domain redirect. For example, a request to a.com/ containing an Authorization header which is redirected to b.com/ will not send that header to b.com. In the event that the client received a subsequent same-domain redirect, however, the sensitive headers would be restored. For example, a chain of redirects from a.com/, to b.com/1, and finally to b.com/2 would incorrectly send the Authorization header to b.com/2."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-201: Insertion of Sensitive Information Into Sent Data",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-18T18:41:11.116Z",
"orgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"shortName": "Go"
},
"references": [
{
"url": "https://go.dev/cl/643100"
},
{
"url": "https://go.dev/issue/70530"
},
{
"url": "https://groups.google.com/g/golang-dev/c/CAWXhan3Jww/m/bk9LAa-lCgAJ"
},
{
"url": "https://groups.google.com/g/golang-dev/c/bG8cv1muIBM/m/G461hA6lCgAJ"
},
{
"url": "https://pkg.go.dev/vuln/GO-2025-3420"
}
],
"title": "Sensitive headers incorrectly sent after cross-domain redirect in net/http"
}
},
"cveMetadata": {
"assignerOrgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"assignerShortName": "Go",
"cveId": "CVE-2024-45336",
"datePublished": "2025-01-28T01:03:24.869Z",
"dateReserved": "2024-08-27T19:41:58.555Z",
"dateUpdated": "2025-09-18T18:41:11.116Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45341 (GCVE-0-2024-45341)
Vulnerability from cvelistv5 – Published: 2025-01-28 01:03 – Updated: 2025-02-21 18:03
VLAI
EPSS
Title
Usage of IPv6 zone IDs can bypass URI name constraints in crypto/x509
Summary
A certificate with a URI which has a IPv6 address with a zone ID may incorrectly satisfy a URI name constraint that applies to the certificate chain. Certificates containing URIs are not permitted in the web PKI, so this only affects users of private PKIs which make use of URIs.
Severity
6.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Go standard library | crypto/x509 |
Affected:
0 , < 1.22.11
(semver)
Affected: 1.23.0-0 , < 1.23.5 (semver) Affected: 1.24.0-0 , < 1.24.0-rc.2 (semver) |
Credits
Juho Forsén of Mattermost
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-45341",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T14:57:00.467281Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T15:16:58.278Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-02-21T18:03:33.296Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20250221-0004/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://pkg.go.dev",
"defaultStatus": "unaffected",
"packageName": "crypto/x509",
"product": "crypto/x509",
"programRoutines": [
{
"name": "matchURIConstraint"
},
{
"name": "CertPool.AppendCertsFromPEM"
},
{
"name": "Certificate.CheckCRLSignature"
},
{
"name": "Certificate.CheckSignature"
},
{
"name": "Certificate.CheckSignatureFrom"
},
{
"name": "Certificate.CreateCRL"
},
{
"name": "Certificate.Verify"
},
{
"name": "Certificate.VerifyHostname"
},
{
"name": "CertificateRequest.CheckSignature"
},
{
"name": "CreateCertificate"
},
{
"name": "CreateCertificateRequest"
},
{
"name": "CreateRevocationList"
},
{
"name": "DecryptPEMBlock"
},
{
"name": "EncryptPEMBlock"
},
{
"name": "HostnameError.Error"
},
{
"name": "MarshalECPrivateKey"
},
{
"name": "MarshalPKCS1PrivateKey"
},
{
"name": "MarshalPKCS1PublicKey"
},
{
"name": "MarshalPKCS8PrivateKey"
},
{
"name": "MarshalPKIXPublicKey"
},
{
"name": "ParseCRL"
},
{
"name": "ParseCertificate"
},
{
"name": "ParseCertificateRequest"
},
{
"name": "ParseCertificates"
},
{
"name": "ParseDERCRL"
},
{
"name": "ParseECPrivateKey"
},
{
"name": "ParsePKCS1PrivateKey"
},
{
"name": "ParsePKCS1PublicKey"
},
{
"name": "ParsePKCS8PrivateKey"
},
{
"name": "ParsePKIXPublicKey"
},
{
"name": "ParseRevocationList"
},
{
"name": "RevocationList.CheckSignatureFrom"
},
{
"name": "SetFallbackRoots"
},
{
"name": "SystemCertPool"
}
],
"vendor": "Go standard library",
"versions": [
{
"lessThan": "1.22.11",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "1.23.5",
"status": "affected",
"version": "1.23.0-0",
"versionType": "semver"
},
{
"lessThan": "1.24.0-rc.2",
"status": "affected",
"version": "1.24.0-0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Juho Fors\u00e9n of Mattermost"
}
],
"descriptions": [
{
"lang": "en",
"value": "A certificate with a URI which has a IPv6 address with a zone ID may incorrectly satisfy a URI name constraint that applies to the certificate chain. Certificates containing URIs are not permitted in the web PKI, so this only affects users of private PKIs which make use of URIs."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-295: Improper Certificate Validation",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T19:14:21.421Z",
"orgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"shortName": "Go"
},
"references": [
{
"url": "https://go.dev/cl/643099"
},
{
"url": "https://go.dev/issue/71156"
},
{
"url": "https://groups.google.com/g/golang-dev/c/bG8cv1muIBM/m/G461hA6lCgAJ"
},
{
"url": "https://groups.google.com/g/golang-dev/c/CAWXhan3Jww/m/bk9LAa-lCgAJ"
},
{
"url": "https://pkg.go.dev/vuln/GO-2025-3373"
}
],
"title": "Usage of IPv6 zone IDs can bypass URI name constraints in crypto/x509"
}
},
"cveMetadata": {
"assignerOrgId": "1bb62c36-49e3-4200-9d77-64a1400537cc",
"assignerShortName": "Go",
"cveId": "CVE-2024-45341",
"datePublished": "2025-01-28T01:03:24.353Z",
"dateReserved": "2024-08-27T19:41:58.556Z",
"dateUpdated": "2025-02-21T18:03:33.296Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45490 (GCVE-0-2024-45490)
Vulnerability from cvelistv5 – Published: 2024-08-30 00:00 – Updated: 2026-05-12 11:57
VLAI
EPSS
Summary
An issue was discovered in libexpat before 2.6.3. xmlparse.c does not reject a negative length for XML_ParseBuffer.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
11 references
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| libexpat_project | libexpat |
Affected:
0 , < 2.6.3
(custom)
cpe:2.3:a:libexpat_project:libexpat:*:*:*:*:*:*:*:* |
|
| Siemens | RUGGEDCOM RST2428P |
Affected:
0 , < V3.1
(custom)
|
|
| Siemens | SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE XCM-/XRM-/XCH-/XRH-300 family |
Affected:
0 , < V3.1
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
|
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP |
Affected:
V3.1.5 , < *
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:libexpat_project:libexpat:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "libexpat",
"vendor": "libexpat_project",
"versions": [
{
"lessThan": "2.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-45490",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-30T18:17:03.200505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T19:07:39.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T16:15:47.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20241018-0004/"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Dec/12"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Dec/10"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Dec/8"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Dec/7"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Dec/6"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/09/msg00036.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2428P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XCM-/XRM-/XCH-/XRH-300 family",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V3.1.5",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T11:57:31.663Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-082556.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-613116.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in libexpat before 2.6.3. xmlparse.c does not reject a negative length for XML_ParseBuffer."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-30T02:10:04.584Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/libexpat/libexpat/pull/890"
},
{
"url": "https://github.com/libexpat/libexpat/issues/887"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-45490",
"datePublished": "2024-08-30T00:00:00.000Z",
"dateReserved": "2024-08-30T00:00:00.000Z",
"dateUpdated": "2026-05-12T11:57:31.663Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…