Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CERTFR-2024-AVI-0476
Vulnerability from certfr_avis - Published: 2024-06-11 - Updated: 2024-06-14
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | Sage 2400 | Sage 2400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions | ||
| Schneider Electric | Sage 1450 | Sage 1450 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1430 | Sage 1430 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 3030 Magnum | Sage 3030 Magnum avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | Sage 1410 | Sage 1410 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | EVlink Home Smart | EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 antérieures à 2.0.5.0.0_134 | ||
| Schneider Electric | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 | ||
| Schneider Electric | Modicon M340 | Modicon M340 toutes versions | ||
| Schneider Electric | PowerLogic P5 | PowerLogic P5 versions antérieures à 02.501.101 | ||
| Schneider Electric | Sage 4400 | Sage 4400 avec un microgiciel antérieur à C3414-500-S02K5_P9 | ||
| Schneider Electric | N/A | SpaceLogic AS-P et SpaceLogic AS-B versions antérieures à 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de sécurité | ||
| Schneider Electric | Network module, Modicon M340, Modbus/TCP BMXNOE0100 | Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Sage 2400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 2400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1450 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1450",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1430 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1430",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 3030 Magnum avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 3030 Magnum",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 1410 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 1410",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 ant\u00e9rieures \u00e0 2.0.5.0.0_134",
"product": {
"name": "EVlink Home Smart",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"product": {
"name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PowerLogic P5 versions ant\u00e9rieures \u00e0 02.501.101",
"product": {
"name": "PowerLogic P5",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Sage 4400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
"product": {
"name": "Sage 4400",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic AS-P et SpaceLogic AS-B versions ant\u00e9rieures \u00e0 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions",
"product": {
"name": "Network module, Modicon M340, Modbus/TCP BMXNOE0100",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-5557",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5557"
},
{
"name": "CVE-2024-37039",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37039"
},
{
"name": "CVE-2024-5558",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5558"
},
{
"name": "CVE-2024-5056",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5056"
},
{
"name": "CVE-2024-37037",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37037"
},
{
"name": "CVE-2024-5559",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5559"
},
{
"name": "CVE-2024-5313",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5313"
},
{
"name": "CVE-2024-37038",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37038"
},
{
"name": "CVE-2024-37040",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37040"
},
{
"name": "CVE-2024-5560",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5560"
},
{
"name": "CVE-2024-37036",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-37036"
}
],
"initial_release_date": "2024-06-11T00:00:00",
"last_revision_date": "2024-06-14T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0476",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-06-11T00:00:00.000000"
},
{
"description": "Ajout des identifiants CVE.",
"revision_date": "2024-06-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
]
}
CVE-2024-37036 (GCVE-0-2024-37036)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:48 – Updated: 2024-08-02 03:43- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Sage 1410 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1430 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1450 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 2400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 3030 Magnum |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 4400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| schneider_electric | sage_4400_firmware |
Affected:
0 , ≤ C3414-500-S02K5_P8
(custom)
cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sage_4400_firmware",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "C3414-500-S02K5_P8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37036",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T17:43:17.841310Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T17:57:45.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:43:50.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Sage 1410",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1430",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1450",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 2400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 3030 Magnum",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 4400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nCWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set.\n\n\n\n"
}
],
"value": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:48:09.163Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-37036",
"datePublished": "2024-06-12T16:48:09.163Z",
"dateReserved": "2024-05-31T06:52:05.762Z",
"dateUpdated": "2024-08-02T03:43:50.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37037 (GCVE-0-2024-37037)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:50 – Updated: 2024-08-02 03:43- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Sage 1410 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1430 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1450 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 2400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 3030 Magnum |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 4400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| schneider-electric | sage_4400 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_4400",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37037",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:28:51.967522Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T18:33:38.098Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:43:50.902Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Sage 1410",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1430",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1450",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 2400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 3030 Magnum",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 4400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\n\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.\n\n\n\n\n\n"
}
],
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:50:09.159Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-37037",
"datePublished": "2024-06-12T16:50:09.159Z",
"dateReserved": "2024-05-31T06:52:05.762Z",
"dateUpdated": "2024-08-02T03:43:50.902Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37038 (GCVE-0-2024-37038)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:51 – Updated: 2024-08-02 03:43- CWE-276 - Incorrect Default Permissions
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Sage 1410 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1430 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1450 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 2400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 3030 Magnum |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 4400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| schneider_electric | sage_4400 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider_electric:sage_4400:*:*:*:*:*:*:*:* |
|
| schneider_electric | sage_1430 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider_electric:sage_1430:*:*:*:*:*:*:*:* |
|
| schneider_electric | sage_2400 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider_electric:sage_2400:*:*:*:*:*:*:*:* |
|
| schneider_electric | sage_3030m |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider_electric:sage_3030m:*:*:*:*:*:*:*:* |
|
| schneider_electric | sage_1410 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider_electric:sage_1410:*:*:*:*:*:*:*:* |
|
| schneider_electric | sage_1450 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider_electric:sage_1450:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider_electric:sage_4400:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_4400",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider_electric:sage_1430:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_1430",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider_electric:sage_2400:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_2400",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider_electric:sage_3030m:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_3030m",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider_electric:sage_1410:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_1410",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider_electric:sage_1450:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_1450",
"vendor": "schneider_electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37038",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T17:44:53.062764Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T17:54:11.618Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:43:50.738Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Sage 1410",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1430",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1450",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 2400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 3030 Magnum",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 4400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\n\n\n\n\nCWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests.\n\n\n\n\n\n\n\n"
}
],
"value": "CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:51:55.800Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-37038",
"datePublished": "2024-06-12T16:51:55.800Z",
"dateReserved": "2024-05-31T06:52:05.762Z",
"dateUpdated": "2024-08-02T03:43:50.738Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37039 (GCVE-0-2024-37039)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:54 – Updated: 2024-08-02 03:43- CWE-252 - Unchecked Return Value
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Sage 1410 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1430 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1450 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 2400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 3030 Magnum |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 4400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| schneider-electric | sage_4400 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_4400",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37039",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:24:08.466465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T18:33:50.964Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:43:50.886Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Sage 1410",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1430",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1450",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 2400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 3030 Magnum",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 4400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\n\n\n\n\n\n\nCWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request.\n\n\n\n\n\n\n\n\n\n"
}
],
"value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-252",
"description": "CWE-252 Unchecked Return Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:54:23.117Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-37039",
"datePublished": "2024-06-12T16:54:23.117Z",
"dateReserved": "2024-05-31T06:52:05.762Z",
"dateUpdated": "2024-08-02T03:43:50.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37040 (GCVE-0-2024-37040)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:56 – Updated: 2024-08-02 03:43- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Sage 1410 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1430 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 1450 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 2400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 3030 Magnum |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| Schneider Electric | Sage 4400 |
Affected:
Versions C3414-500-S02K5_P8 and prior
|
|
| schneider-electric | sage_4400 |
Affected:
0 , ≤ c3414-500-s02k5_p8
(custom)
cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "sage_4400",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "c3414-500-s02k5_p8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37040",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:27:09.666436Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T18:34:05.093Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:43:50.968Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Sage 1410",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1430",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 1450",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 2400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 3030 Magnum",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Sage 4400",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\n\n\n\n\n\n\n\n\nCWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request.\n\n\n\n\n\n\n\n\n\n\n\n"
}
],
"value": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:56:06.117Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-37040",
"datePublished": "2024-06-12T16:56:06.117Z",
"dateReserved": "2024-05-31T06:52:05.762Z",
"dateUpdated": "2024-08-02T03:43:50.968Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5056 (GCVE-0-2024-5056)
Vulnerability from cvelistv5 – Published: 2024-06-12 12:10 – Updated: 2024-08-01 21:03- CWE-552 - Files or Directories Accessible to External Parties
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon M340 |
Affected:
All versions
|
|
| Schneider Electric | Network module, Modicon M340, Modbus/TCP BMXNOE0100 |
Affected:
All versions
|
|
| Schneider Electric | Network module, Modicon M340, Ethernet TCP/IP BMXNOE0110 |
Affected:
All Versions
|
|
| schneider-electric | modicom_m340_firmware |
Affected:
0 , < *
(custom)
cpe:2.3:o:schneider-electric:modicom_m340_firmware:-:*:*:*:*:*:*:* |
|
| schneider-electric | modicom_m340 |
Affected:
0 , < *
(custom)
cpe:2.3:h:schneider-electric:modicom_m340:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicom_m340_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicom_m340_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:modicom_m340:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicom_m340",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5056",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T14:14:02.243238Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T14:17:06.480Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:03:10.683Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Network module, Modicon M340, Modbus/TCP BMXNOE0100",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Network module, Modicon M340, Ethernet TCP/IP BMXNOE0110",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-552: Files or Directories Accessible to External Parties vulnerability exists which may\nprevent user to update the device firmware and prevent proper behavior of the webserver when\nspecific files or directories are removed from the filesystem.\n\n"
}
],
"value": "CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may\nprevent user to update the device firmware and prevent proper behavior of the webserver when\nspecific files or directories are removed from the filesystem."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:10:43.250Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5056",
"datePublished": "2024-06-12T12:10:43.250Z",
"dateReserved": "2024-05-17T10:06:08.565Z",
"dateUpdated": "2024-08-01T21:03:10.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5313 (GCVE-0-2024-5313)
Vulnerability from cvelistv5 – Published: 2024-06-12 12:14 – Updated: 2024-08-01 21:11- CWE-668 - Exposure of Resource to Wrong Sphere
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EVlink Home Smart |
Affected:
v2.0.4.1.2_131
Affected: v2.0.3.8.2_128 |
|
| schneider-electric | evlink_home_smart |
Affected:
2.0.4.1.2_131
Affected: 2.0.3.8.2_128 cpe:2.3:a:schneider-electric:evlink_home_smart:2.0.4.1.2_131:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:evlink_home_smart:2.0.4.1.2_131:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "evlink_home_smart",
"vendor": "schneider-electric",
"versions": [
{
"status": "affected",
"version": "2.0.4.1.2_131"
},
{
"status": "affected",
"version": "2.0.3.8.2_128"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5313",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T14:57:54.307091Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T15:04:51.869Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:11:12.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EVlink Home Smart",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v2.0.4.1.2_131"
},
{
"status": "affected",
"version": "v2.0.3.8.2_128"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface.\n\n"
}
],
"value": "CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:14:58.979Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5313",
"datePublished": "2024-06-12T12:14:58.979Z",
"dateReserved": "2024-05-24T08:29:40.058Z",
"dateUpdated": "2024-08-01T21:11:12.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5557 (GCVE-0-2024-5557)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:28 – Updated: 2024-08-01 21:18- CWE-532 - Insertion of Sensitive Information into Log File
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | SpaceLogic AS-P |
Affected:
V5.0.3 and prior
|
|
| Schneider Electric | SpaceLogic AS-B |
Affected:
V5.0.3 and prior
|
|
| schneider-electric | spacelogic_as-b |
Affected:
0 , ≤ 5.0.3
(custom)
cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:* |
|
| schneider-electric | spacelogic_as-p |
Affected:
0 , ≤ 5.0.3
(custom)
cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "spacelogic_as-b",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "5.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "spacelogic_as-p",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "5.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:09:17.413313Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T18:09:28.568Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SpaceLogic AS-P",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V5.0.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SpaceLogic AS-B",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V5.0.3 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
}
],
"value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-13T19:01:56.888Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5557",
"datePublished": "2024-06-12T16:28:56.844Z",
"dateReserved": "2024-05-31T06:58:40.277Z",
"dateUpdated": "2024-08-01T21:18:06.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5558 (GCVE-0-2024-5558)
Vulnerability from cvelistv5 – Published: 2024-06-12 16:26 – Updated: 2024-08-01 21:18- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | SpaceLogic AS-P |
Affected:
V5.0.3 and prior
|
|
| Schneider Electric | SpaceLogic AS-B |
Affected:
V5.0.3 and prior
|
|
| schneider-electric | spacelogic_as-b |
Affected:
0 , ≤ 5.0.3
(custom)
cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:* |
|
| schneider-electric | spacelogic_as-p |
Affected:
0 , ≤ 5.0.3
(custom)
cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "spacelogic_as-b",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "5.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "spacelogic_as-p",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "5.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:07:10.554620Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T16:20:36.411Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.335Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SpaceLogic AS-P",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V5.0.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SpaceLogic AS-B",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V5.0.3 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account.\n\n"
}
],
"value": "CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T16:26:26.294Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5558",
"datePublished": "2024-06-12T16:26:26.294Z",
"dateReserved": "2024-05-31T06:58:47.453Z",
"dateUpdated": "2024-08-01T21:18:06.335Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5559 (GCVE-0-2024-5559)
Vulnerability from cvelistv5 – Published: 2024-06-12 17:18 – Updated: 2024-08-01 21:18- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | PowerLogic P5 |
Affected:
v01.500.104 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-01T20:49:53.165251Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-01T21:26:14.765Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerLogic P5",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v01.500.104 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could\ncause denial of service, device reboot, or an attacker gaining full control of the relay when a\nspecially crafted reset token is entered into the front panel of the device.\n\n\n"
}
],
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could\ncause denial of service, device reboot, or an attacker gaining full control of the relay when a\nspecially crafted reset token is entered into the front panel of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T17:18:04.604Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5559",
"datePublished": "2024-06-12T17:18:04.604Z",
"dateReserved": "2024-05-31T06:58:51.639Z",
"dateUpdated": "2024-08-01T21:18:06.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.