Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
415 vulnerabilities by schneider-electric
CVE-2026-2401 (GCVE-0-2026-2401)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:24 – Updated: 2026-04-14 16:27
VLAI?
Summary
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
Severity ?
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions 1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2401",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T16:23:13.716274Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T16:27:16.331Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker."
}
],
"value": "CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 2.4,
"baseSeverity": "LOW",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:24:17.233Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2401",
"datePublished": "2026-04-14T15:24:17.233Z",
"dateReserved": "2026-02-12T13:18:59.627Z",
"dateUpdated": "2026-04-14T16:27:16.331Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2400 (GCVE-0-2026-2400)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:22 – Updated: 2026-04-14 16:27
VLAI?
Summary
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.
Severity ?
CWE
- CWE-93 - Improper Neutralization of CRLF Sequences ('CRLF Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions 1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T16:23:35.812067Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T16:27:22.220Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027) vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload."
}
],
"value": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027) vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-93",
"description": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:22:53.245Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2400",
"datePublished": "2026-04-14T15:22:53.245Z",
"dateReserved": "2026-02-12T13:17:07.149Z",
"dateUpdated": "2026-04-14T16:27:22.220Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2403 (GCVE-0-2026-2403)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:21 – Updated: 2026-04-14 16:27
VLAI?
Summary
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.
Severity ?
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions 1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2403",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T16:23:47.895593Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T16:27:27.629Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload."
}
],
"value": "CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284 Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:21:10.802Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2403",
"datePublished": "2026-04-14T15:21:10.802Z",
"dateReserved": "2026-02-12T13:19:02.490Z",
"dateUpdated": "2026-04-14T16:27:27.629Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2405 (GCVE-0-2026-2405)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:19 – Updated: 2026-04-14 16:27
VLAI?
Summary
CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions 1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2405",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T16:25:50.086988Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T16:27:33.148Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests."
}
],
"value": "CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:19:40.765Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2405",
"datePublished": "2026-04-14T15:19:40.765Z",
"dateReserved": "2026-02-12T13:19:05.750Z",
"dateUpdated": "2026-04-14T16:27:33.148Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2402 (GCVE-0-2026-2402)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:16 – Updated: 2026-04-14 16:27
VLAI?
Summary
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.
Severity ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions v1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T16:26:07.842287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T16:27:38.566Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions v1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints."
}
],
"value": "CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:16:42.073Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2402",
"datePublished": "2026-04-14T15:16:17.583Z",
"dateReserved": "2026-02-12T13:19:01.113Z",
"dateUpdated": "2026-04-14T16:27:38.566Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2404 (GCVE-0-2026-2404)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:13 – Updated: 2026-04-14 16:27
VLAI?
Summary
CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.
Severity ?
CWE
- CWE-116 - Improper Encoding or Escaping of Output
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions 1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2404",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T16:26:32.467506Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T16:27:43.927Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload."
}
],
"value": "CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-116",
"description": "CWE-116 Improper Encoding or Escaping of Output",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:13:50.351Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2404",
"datePublished": "2026-04-14T15:13:50.351Z",
"dateReserved": "2026-02-12T13:19:03.924Z",
"dateUpdated": "2026-04-14T16:27:43.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2399 (GCVE-0-2026-2399)
Vulnerability from cvelistv5 – Published: 2026-04-14 15:09 – Updated: 2026-04-14 15:52
VLAI?
Summary
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.
Severity ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | PowerChute™ Serial Shutdown |
Affected:
Versions 1.4 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-14T15:51:11.359624Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:52:07.599Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerChute\u2122 Serial Shutdown",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 1.4 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload."
}
],
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T15:09:58.751Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-104-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2026-2399",
"datePublished": "2026-04-14T15:09:58.751Z",
"dateReserved": "2026-02-12T13:16:54.228Z",
"dateUpdated": "2026-04-14T15:52:07.599Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-13844 (GCVE-0-2025-13844)
Vulnerability from cvelistv5 – Published: 2026-01-15 18:28 – Updated: 2026-01-15 18:55
VLAI?
Summary
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
Severity ?
CWE
- CWE-415 - Double Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure Power Build Rapsody |
Affected:
FR v2.8.1 and prior
Affected: INT v2.8.6 and prior Affected: ES v2.8.5 and prior Affected: BEL (NL) v2.8.3 and prior Affected: BEL (FR) v2.8.8 and prior |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13844",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-15T18:55:20.238410Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-15T18:55:41.866Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Build Rapsody",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "FR v2.8.1 and prior"
},
{
"status": "affected",
"version": "INT v2.8.6 and prior"
},
{
"status": "affected",
"version": "ES v2.8.5 and prior"
},
{
"status": "affected",
"version": "BEL (NL) v2.8.3 and prior"
},
{
"status": "affected",
"version": "BEL (FR) v2.8.8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody."
}
],
"value": "CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-415",
"description": "CWE-415 Double Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-15T18:28:37.316Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-013-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-13844",
"datePublished": "2026-01-15T18:28:37.316Z",
"dateReserved": "2025-12-01T19:13:56.544Z",
"dateUpdated": "2026-01-15T18:55:41.866Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-10575 (GCVE-0-2024-10575)
Vulnerability from cvelistv5 – Published: 2024-11-13 04:35 – Updated: 2024-11-13 15:14
VLAI?
Summary
CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on
the network and potentially impacting connected devices.
Severity ?
9.8 (Critical)
CWE
- CWE-862 - Missing Authorization
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure IT Gateway |
Affected:
Version 1.21.0.6
Affected: Version 1.22.0.3 Affected: Version 1.22.1.5 Affected: Version 1.23.0.4 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ecostruxure_it_gateway",
"vendor": "schneider-electric",
"versions": [
{
"status": "affected",
"version": "1.21.0.6"
},
{
"status": "affected",
"version": "1.22.0.3"
},
{
"status": "affected",
"version": "1.22.1.5"
},
{
"status": "affected",
"version": "1.23.0.4"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10575",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-13T15:14:10.869591Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T15:14:17.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure IT Gateway",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 1.21.0.6"
},
{
"status": "affected",
"version": "Version 1.22.0.3"
},
{
"status": "affected",
"version": "Version 1.22.1.5"
},
{
"status": "affected",
"version": "Version 1.23.0.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\nthe network and potentially impacting connected devices."
}
],
"value": "CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\nthe network and potentially impacting connected devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T04:35:44.556Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/doc/SEVD-2024-317-04/SEVD-2024-317-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-10575",
"datePublished": "2024-11-13T04:35:44.556Z",
"dateReserved": "2024-10-31T08:33:14.823Z",
"dateUpdated": "2024-11-13T15:14:17.114Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8422 (GCVE-0-2024-8422)
Vulnerability from cvelistv5 – Published: 2024-10-08 10:09 – Updated: 2024-10-08 13:51
VLAI?
Summary
CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial
of service and loss of confidentiality & integrity when application user opens a malicious Zelio
Soft 2 project file.
Severity ?
7.8 (High)
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Zelio Soft 2 |
Affected:
Versions prior to 5.4.2.2
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:zelio_soft_2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "zelio_soft_2",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "5.4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8422",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-08T12:43:43.813201Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T13:51:54.776Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Zelio Soft 2",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.4.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial\nof service and loss of confidentiality \u0026amp; integrity when application user opens a malicious Zelio\nSoft 2 project file."
}
],
"value": "CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial\nof service and loss of confidentiality \u0026 integrity when application user opens a malicious Zelio\nSoft 2 project file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T10:09:34.543Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-8422",
"datePublished": "2024-10-08T10:09:34.543Z",
"dateReserved": "2024-09-04T14:02:49.645Z",
"dateUpdated": "2024-10-08T13:51:54.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8306 (GCVE-0-2024-8306)
Vulnerability from cvelistv5 – Published: 2024-09-11 15:05 – Updated: 2024-09-11 18:21
VLAI?
Summary
CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized
access, loss of confidentiality, integrity and availability of the workstation when non-admin
authenticated user tries to perform privilege escalation by tampering with the binaries.
Severity ?
7.8 (High)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Vijeo Designer |
Affected:
Prior to V6.3 SP1
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:vijeo_designer:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vijeo_designer",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "6.3 SP1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8306",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T18:16:24.377142Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:21:20.415Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Vijeo Designer",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Prior to V6.3 SP1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Vijeo Designer embedded in EcoStruxure\u2122 Machine Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries."
}
],
"value": "CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T15:05:31.560Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-254-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-254-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-8306",
"datePublished": "2024-09-11T15:05:31.560Z",
"dateReserved": "2024-08-29T09:01:34.777Z",
"dateUpdated": "2024-09-11T18:21:20.415Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2602 (GCVE-0-2024-2602)
Vulnerability from cvelistv5 – Published: 2024-07-11 08:46 – Updated: 2024-08-01 19:18
VLAI?
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path
Traversal') vulnerability exists that could result in remote code execution when an authenticated
user executes a saved project file that has been tampered by a malicious actor.
Severity ?
7.3 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | FoxRTU Station |
Affected:
All versions prior to v9.3.0
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:foxrtu_station:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "foxrtu_station",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "9.3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2602",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T20:16:22.283836Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T20:26:07.837Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.118Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-03.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FoxRTU Station",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions prior to v9.3.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path\nTraversal\u0027) vulnerability exists that could result in remote code execution when an authenticated\nuser executes a saved project file that has been tampered by a malicious actor.\n\n"
}
],
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path\nTraversal\u0027) vulnerability exists that could result in remote code execution when an authenticated\nuser executes a saved project file that has been tampered by a malicious actor."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T08:46:13.920Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-2602",
"datePublished": "2024-07-11T08:46:13.920Z",
"dateReserved": "2024-03-18T13:19:23.946Z",
"dateUpdated": "2024-08-01T19:18:48.118Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5681 (GCVE-0-2024-5681)
Vulnerability from cvelistv5 – Published: 2024-07-11 08:27 – Updated: 2025-08-27 21:33
VLAI?
Summary
CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service,
privilege escalation, and potentially kernel execution when a malicious actor with local user
access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
Severity ?
7.8 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure Foxboro DCS Core Control Services |
Affected:
Versions 9.8 and prior
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider_electric:ecostruxure_foxboro_dcs_core_control_services:9.8:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ecostruxure_foxboro_dcs_core_control_services",
"vendor": "schneider_electric",
"versions": [
{
"lessThan": "9.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T13:19:04.878587Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T21:33:27.004Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.902Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Foxboro DCS Core Control Services",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service,\nprivilege escalation, and potentially kernel execution when a malicious actor with local user\naccess crafts a script/program using an IOCTL call in the Foxboro.sys driver.\n\n\n\n"
}
],
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service,\nprivilege escalation, and potentially kernel execution when a malicious actor with local user\naccess crafts a script/program using an IOCTL call in the Foxboro.sys driver."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T08:27:49.614Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5681",
"datePublished": "2024-07-11T08:27:49.614Z",
"dateReserved": "2024-06-06T12:06:44.310Z",
"dateUpdated": "2025-08-27T21:33:27.004Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5680 (GCVE-0-2024-5680)
Vulnerability from cvelistv5 – Published: 2024-07-11 08:25 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL
call in the Foxboro.sys driver.
Severity ?
7.1 (High)
CWE
- CWE-129 - Improper Validation of Array Index
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure Foxboro DCS Core Control Services |
Affected:
Versions 9.8 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T14:11:30.265135Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T14:11:39.357Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.841Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Foxboro DCS Core Control Services",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nCWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver.\n\n\n\n"
}
],
"value": "CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL\ncall in the Foxboro.sys driver."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-129",
"description": "CWE-129 Improper Validation of Array Index",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T08:25:45.578Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5680",
"datePublished": "2024-07-11T08:25:45.578Z",
"dateReserved": "2024-06-06T12:06:41.878Z",
"dateUpdated": "2024-08-01T21:18:06.841Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5679 (GCVE-0-2024-5679)
Vulnerability from cvelistv5 – Published: 2024-07-11 08:18 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or
kernel memory leak when a malicious actor with local user access crafts a script/program using
an IOCTL call in the Foxboro.sys driver.
Severity ?
7.1 (High)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure Foxboro DCS Core Control Services |
Affected:
Versions 9.8 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5679",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T14:05:59.571941Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T18:01:50.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.706Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Foxboro DCS Core Control Services",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.8 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or\nkernel memory leak when a malicious actor with local user access crafts a script/program using\nan IOCTL call in the Foxboro.sys driver.\n\n"
}
],
"value": "CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or\nkernel memory leak when a malicious actor with local user access crafts a script/program using\nan IOCTL call in the Foxboro.sys driver."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T08:18:23.853Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-5679",
"datePublished": "2024-07-11T08:18:23.853Z",
"dateReserved": "2024-06-06T12:06:38.709Z",
"dateUpdated": "2024-08-01T21:18:06.706Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0865 (GCVE-0-2024-0865)
Vulnerability from cvelistv5 – Published: 2024-06-12 17:23 – Updated: 2024-08-01 18:18
VLAI?
Summary
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege
escalation when logged in as a non-administrative user.
Severity ?
7.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure IT Gateway |
Affected:
1.20.x and prior
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ecostruxure_it_gateway",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "1.20.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0865",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T19:59:08.710375Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T20:04:39.540Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:18:18.824Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure IT Gateway",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "1.20.x and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\nescalation when logged in as a non-administrative user."
}
],
"value": "CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\nescalation when logged in as a non-administrative user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T17:23:00.908Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-0865",
"datePublished": "2024-06-12T17:23:00.908Z",
"dateReserved": "2024-01-24T17:18:07.117Z",
"dateUpdated": "2024-08-01T18:18:18.824Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2747 (GCVE-0-2024-2747)
Vulnerability from cvelistv5 – Published: 2024-06-12 17:12 – Updated: 2024-08-19 17:40
VLAI?
Summary
CWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could
cause privilege escalation when a valid user replaces a trusted file name on the system and
reboots the machine.
Severity ?
7.8 (High)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Easergy Studio |
Affected:
v9.3.3 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:41.491Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-100-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-100-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:easergy_studio:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "easergy_studio",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "9.3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2747",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T17:39:11.706286Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-19T17:40:23.892Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Easergy Studio",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v9.3.3 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could\ncause privilege escalation when a valid user replaces a trusted file name on the system and\nreboots the machine.\n\n"
}
],
"value": "CWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could\ncause privilege escalation when a valid user replaces a trusted file name on the system and\nreboots the machine."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428 Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T17:12:20.482Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-100-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-100-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-2747",
"datePublished": "2024-06-12T17:12:20.482Z",
"dateReserved": "2024-03-20T16:57:16.005Z",
"dateUpdated": "2024-08-19T17:40:23.892Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-27975 (GCVE-0-2023-27975)
Vulnerability from cvelistv5 – Published: 2024-02-14 16:55 – Updated: 2024-08-02 12:23
VLAI?
Summary
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized
access to the project file in EcoStruxure Control Expert when a local user tampers with the
memory of the engineering workstation.
Severity ?
7.1 (High)
CWE
- CWE-522 - Insufficiently Protected Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure Control Expert |
Affected:
Versions prior to v16.0
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-27975",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-21T20:31:05.372971Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:24:48.765Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:23:30.803Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v16.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Process Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v2023"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized\naccess to the project file in EcoStruxure Control Expert when a local user tampers with the\nmemory of the engineering workstation.\n\n"
}
],
"value": "\nCWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized\naccess to the project file in EcoStruxure Control Expert when a local user tampers with the\nmemory of the engineering workstation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T16:55:41.495Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-27975",
"datePublished": "2024-02-14T16:55:41.495Z",
"dateReserved": "2023-03-09T05:25:56.973Z",
"dateUpdated": "2024-08-02T12:23:30.803Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6408 (GCVE-0-2023-6408)
Vulnerability from cvelistv5 – Published: 2024-02-14 16:52 – Updated: 2024-08-02 08:28
VLAI?
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a
Communication Channel vulnerability exists that could cause a denial of service and loss of
confidentiality, integrity of controllers when conducting a Man in the Middle attack.
Severity ?
8.1 (High)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
Versions prior to sv3.60
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m580_bmep585040_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "4.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m340_bmxp342030h_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "3.60",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m580_bmeh586040s_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6408",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T19:15:41.696437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-17T19:36:47.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to sv3.60"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to sv4.20"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v16.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Process Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v2023"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
}
],
"value": "\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T16:52:24.805Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-6408",
"datePublished": "2024-02-14T16:52:24.805Z",
"dateReserved": "2023-11-30T09:52:30.945Z",
"dateUpdated": "2024-08-02T08:28:21.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6409 (GCVE-0-2023-6409)
Vulnerability from cvelistv5 – Published: 2024-02-14 16:47 – Updated: 2025-05-12 14:07
VLAI?
Summary
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized
access to a project file protected with application password when opening the file with
EcoStruxure Control Expert.
Severity ?
7.7 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure Control Expert |
Affected:
Versions prior to v16.0
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.802Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6409",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:45:11.076269Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-12T14:07:03.007Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v16.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Process Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v2023"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized\naccess to a project file protected with application password when opening the file with\nEcoStruxure Control Expert.\n\n"
}
],
"value": "\nCWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized\naccess to a project file protected with application password when opening the file with\nEcoStruxure Control Expert.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T16:47:05.519Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-6409",
"datePublished": "2024-02-14T16:47:05.519Z",
"dateReserved": "2023-11-30T09:53:56.413Z",
"dateUpdated": "2025-05-12T14:07:03.007Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-7032 (GCVE-0-2023-7032)
Vulnerability from cvelistv5 – Published: 2024-01-09 19:30 – Updated: 2024-11-14 15:09
VLAI?
Summary
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker
logged in with a user level account to gain higher privileges by providing a harmful serialized
object.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Easergy Studio |
Affected:
All , ≤ <=9.3.5
(custom)
|
Date Public ?
2024-01-09 08:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:50:07.764Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-009-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-009-02.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-7032",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-20T05:00:32.605811Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-14T15:09:02.901Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Easergy Studio",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "\u003c=9.3.5",
"status": "affected",
"version": "All ",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-01-09T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker\nlogged in with a user level account to gain higher privileges by providing a harmful serialized\nobject.\n\n"
}
],
"value": "\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker\nlogged in with a user level account to gain higher privileges by providing a harmful serialized\nobject.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T19:30:19.835Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-009-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-009-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-7032",
"datePublished": "2024-01-09T19:30:19.835Z",
"dateReserved": "2023-12-20T22:29:58.270Z",
"dateUpdated": "2024-11-14T15:09:02.901Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6407 (GCVE-0-2023-6407)
Vulnerability from cvelistv5 – Published: 2023-12-14 05:02 – Updated: 2026-02-25 16:34
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by
a local and low-privileged attacker.
Severity ?
5.3 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Easy UPS Online Monitoring Software |
Affected:
2.6-GA-01-23116 and prior (Windows 10, 11, Windows Server 2016, 2019, 2022)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.777Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-346-03.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6407",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-23T05:01:13.272988Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-25T16:34:33.707Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "2.6-GA-01-23116 and prior (Windows 10, 11, Windows Server 2016, 2019, 2022)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\nvulnerability exists that could cause arbitrary file deletion upon service restart when accessed by\na local and low-privileged attacker.\n\n"
}
],
"value": "\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\nvulnerability exists that could cause arbitrary file deletion upon service restart when accessed by\na local and low-privileged attacker.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T05:02:30.242Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-346-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-6407",
"datePublished": "2023-12-14T05:02:30.242Z",
"dateReserved": "2023-11-30T09:44:49.961Z",
"dateUpdated": "2026-02-25T16:34:33.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-5987 (GCVE-0-2023-5987)
Vulnerability from cvelistv5 – Published: 2023-11-15 03:48 – Updated: 2024-08-02 08:14
VLAI?
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)
vulnerability that could cause a vulnerability leading to a cross site scripting condition where
attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing
the injected payload.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure Power Monitoring Expert (PME) |
Affected:
Version 2020 CU2 and prior
Affected: Version 2021 CU1 and prior |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.122Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2020 CU2 and prior"
},
{
"status": "affected",
"version": "Version 2021 CU1 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
},
{
"status": "affected",
"version": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
}
],
"value": "\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-15T03:48:50.993Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5987",
"datePublished": "2023-11-15T03:48:50.993Z",
"dateReserved": "2023-11-07T10:58:51.030Z",
"dateUpdated": "2024-08-02T08:14:25.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5986 (GCVE-0-2023-5986)
Vulnerability from cvelistv5 – Published: 2023-11-15 03:47 – Updated: 2024-12-02 21:11
VLAI?
Summary
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input
attackers can cause the software’s web application to redirect to the chosen domain after a
successful login is performed.
Severity ?
8.2 (High)
CWE
- CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure Power Monitoring Expert (PME) |
Affected:
Version 2020 CU2 and prior
Affected: Version 2021 CU1 and prior |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:25.141Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-11-30T19:15:01.048115Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T21:11:40.870Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2020 CU2 and prior"
},
{
"status": "affected",
"version": "Version 2021 CU1 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
},
{
"status": "affected",
"version": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"
}
],
"value": "\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-15T03:47:17.684Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5986",
"datePublished": "2023-11-15T03:47:17.684Z",
"dateReserved": "2023-11-07T10:57:54.715Z",
"dateUpdated": "2024-12-02T21:11:40.870Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5391 (GCVE-0-2023-5391)
Vulnerability from cvelistv5 – Published: 2023-10-04 18:13 – Updated: 2025-02-27 20:46
VLAI?
Summary
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to
execute arbitrary code on the targeted system by sending a specifically crafted packet to the
application.
Severity ?
9.8 (Critical)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure Power Monitoring Expert |
Affected:
All versions – prior to application of Hotfix-145271
|
||||||||||||
|
||||||||||||||
Date Public ?
2023-10-10 17:55
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.528Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-02.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5391",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:43.582116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:31.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Monitoring Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions \u2013 prior to application of Hotfix-145271"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power Operation (EPO) with Advanced Reports",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions \u2013 prior to application of Hotfix-145271"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Power SCADA Operation with Advanced Reports",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions \u2013 prior to application of Hotfix-145271"
}
]
}
],
"datePublic": "2023-10-10T17:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to\nexecute arbitrary code on the targeted system by sending a specifically crafted packet to the\napplication.\n\n\n\n\u003cbr\u003e"
}
],
"value": "\n\n\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to\nexecute arbitrary code on the targeted system by sending a specifically crafted packet to the\napplication.\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-11T08:25:11.967Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5391",
"datePublished": "2023-10-04T18:13:00.746Z",
"dateReserved": "2023-10-04T17:50:08.965Z",
"dateUpdated": "2025-02-27T20:46:31.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5399 (GCVE-0-2023-5399)
Vulnerability from cvelistv5 – Published: 2023-10-04 18:07 – Updated: 2025-02-27 20:46
VLAI?
Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path
Traversal') vulnerability exists that could cause tampering of files on the personal computer
running C-Bus when using the File Command.
Severity ?
9.8 (Critical)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | C-Bus Toolkit |
Affected:
v1.16.3 and prior
|
Date Public ?
2023-10-10 17:55
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.730Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:45.603735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:38.228Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "C-Bus Toolkit",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v1.16.3 and prior "
}
]
}
],
"datePublic": "2023-10-10T17:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\n\n\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path\nTraversal\u0027) vulnerability exists that could cause tampering of files on the personal computer\nrunning C-Bus when using the File Command.\n\n\n\n"
}
],
"value": "\n\n\n\n\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path\nTraversal\u0027) vulnerability exists that could cause tampering of files on the personal computer\nrunning C-Bus when using the File Command.\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-11T08:18:53.267Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5399",
"datePublished": "2023-10-04T18:07:29.571Z",
"dateReserved": "2023-10-04T17:50:51.357Z",
"dateUpdated": "2025-02-27T20:46:38.228Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5402 (GCVE-0-2023-5402)
Vulnerability from cvelistv5 – Published: 2023-10-04 17:59 – Updated: 2025-02-27 20:46
VLAI?
Summary
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote
code execution when the transfer command is used over the network.
Severity ?
9.8 (Critical)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | C-Bus Toolkit |
Affected:
v1.16.3 and prior
|
Date Public ?
2023-10-10 17:55
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.294Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:47.338346Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:53.296Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "C-Bus Toolkit",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v1.16.3 and prior "
}
]
}
],
"datePublic": "2023-10-10T17:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
}
],
"value": "\n\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a remote\ncode execution when the transfer command is used over the network.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-11T08:14:27.514Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-283-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-5402",
"datePublished": "2023-10-04T17:59:59.273Z",
"dateReserved": "2023-10-04T17:50:52.167Z",
"dateUpdated": "2025-02-27T20:46:53.296Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4516 (GCVE-0-2023-4516)
Vulnerability from cvelistv5 – Published: 2023-09-14 08:54 – Updated: 2025-02-27 20:52
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update
Service that could allow a local attacker to change update source, potentially leading to remote
code execution when the attacker force an update containing malicious content.
Severity ?
7.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | IGSS Update Service (IGSSupdateservice.exe) |
Affected:
v16.0.0.23211 and prior
|
Date Public ?
2023-09-12 08:53
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:31:06.157Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4516",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:51:14.783705Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:52:17.879Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IGSS Update Service (IGSSupdateservice.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v16.0.0.23211 and prior"
}
]
}
],
"datePublic": "2023-09-12T08:53:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-14T08:54:53.673Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-255-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-4516",
"datePublished": "2023-09-14T08:54:53.673Z",
"dateReserved": "2023-08-24T10:47:22.919Z",
"dateUpdated": "2025-02-27T20:52:17.879Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3953 (GCVE-0-2023-3953)
Vulnerability from cvelistv5 – Published: 2023-08-09 14:02 – Updated: 2024-10-09 18:10
VLAI?
Summary
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory
Buffer vulnerability exists that could cause memory corruption when an authenticated user
opens a tampered log file from GP-Pro EX.
Severity ?
5.3 (Medium)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | GP-Pro EX WinGP for iPC |
Affected:
v4.09.450 and prior
|
|||||||
|
|||||||||
Date Public ?
2023-08-08 13:56
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:08:50.790Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-220-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-220-01.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3953",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T17:55:24.434489Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T18:10:11.842Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GP-Pro EX WinGP for iPC",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v4.09.450 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GP-Pro EX WinGP for PC/AT",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "v4.09.450 and prior"
}
]
}
],
"datePublic": "2023-08-08T13:56:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-119: Improper Restriction of Operations within the Bounds of a Memory\nBuffer vulnerability exists that could cause memory corruption when an authenticated user\nopens a tampered log file from GP-Pro EX."
}
],
"value": "\nA CWE-119: Improper Restriction of Operations within the Bounds of a Memory\nBuffer vulnerability exists that could cause memory corruption when an authenticated user\nopens a tampered log file from GP-Pro EX."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-09T14:02:44.472Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-220-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-220-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-3953",
"datePublished": "2023-08-09T14:02:44.472Z",
"dateReserved": "2023-07-26T08:14:55.340Z",
"dateUpdated": "2024-10-09T18:10:11.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29414 (GCVE-0-2023-29414)
Vulnerability from cvelistv5 – Published: 2023-07-12 08:18 – Updated: 2024-11-07 14:44
VLAI?
Summary
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability
exists that could cause user privilege escalation if a local user sends specific string input to a
local function call.
Severity ?
7.8 (High)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Accutech Manager |
Affected:
Version 2.7 and prior
|
Date Public ?
2023-07-11 08:17
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:45.730Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-03.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:schneider-electric:accutech_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "accutech_manager",
"vendor": "schneider-electric",
"versions": [
{
"lessThanOrEqual": "2.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29414",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-07T14:42:01.511585Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-07T14:44:09.486Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Accutech Manager",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2.7 and prior"
}
]
}
],
"datePublic": "2023-07-11T08:17:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"
}
],
"value": "\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-12T08:18:01.709Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29414",
"datePublished": "2023-07-12T08:18:01.709Z",
"dateReserved": "2023-04-05T20:35:41.368Z",
"dateUpdated": "2024-11-07T14:44:09.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}