Search

Find a vulnerability

Search criteria

    378 vulnerabilities found for teamcenter_visualization by siemens

    CVE-2025-32454 (GCVE-0-2025-32454)

    Vulnerability from nvd – Published: 2025-05-13 09:38 – Updated: 2025-06-10 15:17
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 14:10 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-32454",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T14:10:31.587086Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T14:12:07.157Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0004",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.14), Teamcenter Visualization V2312 (All versions \u003c V2312.0010), Teamcenter Visualization V2406 (All versions \u003c V2406.0008), Teamcenter Visualization V2412 (All versions \u003c V2412.0004), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-10T15:17:24.833Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-542540.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-486186.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-32454",
        "datePublished": "2025-05-13T09:38:44.621Z",
        "dateReserved": "2025-04-08T15:46:35.199Z",
        "dateUpdated": "2025-06-10T15:17:24.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-27438 (GCVE-0-2025-27438)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:26
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:26 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27438",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:26:38.797340Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:26:49.545Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:31.489Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-27438",
        "datePublished": "2025-03-11T09:48:31.489Z",
        "dateReserved": "2025-02-25T16:39:12.235Z",
        "dateUpdated": "2025-03-11T13:26:49.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23402 (GCVE-0-2025-23402)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:29
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 14:28 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23402",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:28:48.184791Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:29:22.710Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416: Use After Free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:18.241Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23402",
        "datePublished": "2025-03-11T09:48:18.241Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T14:29:22.710Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23401 (GCVE-0-2025-23401)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:31
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 14:30 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23401",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:30:32.123564Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:31:03.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:16.806Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23401",
        "datePublished": "2025-03-11T09:48:16.806Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T14:31:03.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23400 (GCVE-0-2025-23400)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:59
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 14:57 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23400",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:57:36.559116Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:59:33.908Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:15.383Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23400",
        "datePublished": "2025-03-11T09:48:15.383Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T14:59:33.908Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23399 (GCVE-0-2025-23399)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 15:05
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 15:02 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23399",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:02:55.935480Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:05:09.830Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:13.954Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23399",
        "datePublished": "2025-03-11T09:48:13.954Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T15:05:09.830Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23398 (GCVE-0-2025-23398)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:45
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:45 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23398",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:45:05.413293Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:45:43.215Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:12.525Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23398",
        "datePublished": "2025-03-11T09:48:12.525Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T13:45:43.215Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23397 (GCVE-0-2025-23397)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:48
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:47 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23397",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:47:07.609257Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:48:23.588Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:11.135Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23397",
        "datePublished": "2025-03-11T09:48:11.135Z",
        "dateReserved": "2025-01-15T14:20:46.046Z",
        "dateUpdated": "2025-03-11T13:48:23.588Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23396 (GCVE-0-2025-23396)

    Vulnerability from nvd – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:49
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:49 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23396",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:49:04.408654Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:49:18.776Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:09.716Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23396",
        "datePublished": "2025-03-11T09:48:09.716Z",
        "dateReserved": "2025-01-15T14:20:46.046Z",
        "dateUpdated": "2025-03-11T13:49:18.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-53242 (GCVE-0-2024-53242)

    Vulnerability from nvd – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-12-10 15:17 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-53242",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-10T15:17:17.154033Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-10T17:17:29.175Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0016",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-10T13:54:13.403Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-53242",
        "datePublished": "2024-12-10T13:54:13.403Z",
        "dateReserved": "2024-11-19T17:51:57.294Z",
        "dateUpdated": "2024-12-10T17:17:29.175Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-53041 (GCVE-0-2024-53041)

    Vulnerability from nvd – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-12-10 15:17 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-53041",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-10T15:17:30.639993Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-10T17:17:19.652Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0016",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-10T13:54:12.113Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-53041",
        "datePublished": "2024-12-10T13:54:12.113Z",
        "dateReserved": "2024-11-19T16:38:17.725Z",
        "dateUpdated": "2024-12-10T17:17:19.652Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-7066 (GCVE-0-2023-7066)

    Vulnerability from nvd – Published: 2024-08-12 21:46 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read
    Summary
    The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-14 13:56 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V14.3.0.8 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization Affected: 0 , < V14.1.0.14 (custom)
    Affected: 0 , < V14.2.0.10 (custom)
    Affected: 0 , < V14.3.0.8 (custom)
    Affected: 0 , < V2312.0002 (custom)
    Create a notification for this product.
    siemens jt2go Affected: 0 , < 14.3.0.8 (custom)
        cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < 14.1.0.14 (custom)
    Affected: 0 , < 14.2.0.10 (custom)
    Affected: 0 , < 14.3.0.8 (custom)
    Affected: 0 , < 2312.0002 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "jt2go",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-7066",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T13:56:38.749766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:53.230Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Teamcenter Visualization",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.1.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V14.2.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V14.3.0.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V2312.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "MoyunSec reported this vulnerability to Siemens."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
                }
              ],
              "value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-12T21:46:38.910Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722010.html"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\nSiemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\u003c/p\u003e\u003cul\u003e\u003cli\u003eTeamcenter Visualization V14.1: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.1.0.14 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.2: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.2.0.10 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eJT2Go: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.3: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V2312: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV2312.0002 or later version\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\nFor more information see the associated Siemens security advisory SSA-722010\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\n\n  *  Teamcenter Visualization V14.1: Update to  V14.1.0.14 or later version https://support.sw.siemens.com/ \n  *  Teamcenter Visualization V14.2: Update to  V14.2.0.10 or later version https://support.sw.siemens.com/ \n  *  JT2Go: Update to  V14.3.0.8 or later version https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/ \n  *  Teamcenter Visualization V14.3: Update to  V14.3.0.8 or later version https://support.sw.siemens.com/ \n  *  Teamcenter Visualization V2312: Update to  V2312.0002 or later version https://support.sw.siemens.com/ \n\n\n\nFor more information see the associated Siemens security advisory SSA-722010"
            }
          ],
          "source": {
            "advisory": "ICSA-24-193-03",
            "discovery": "EXTERNAL"
          },
          "title": "Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eTo reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\u003cbr\u003e\u003c/p\u003e\u003cul\u003e\n\u003c/ul\u003e\n\u003cp\u003eAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eSiemens\u0027 operational guidelines for industrial security\u003c/a\u003e and following recommendations in the product manuals.\u003c/p\u003e\n\u003cp\u003eAdditional information on industrial security by Siemens can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens industrial security webpage\u003c/a\u003e\u003c/p\u003eFor more information see the associated Siemens security advisory SSA-722010\n\n\u003cbr\u003e"
                }
              ],
              "value": "To reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\n\n\n\n\n\n\nAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to  Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security  and following recommendations in the product manuals.\n\n\nAdditional information on industrial security by Siemens can be found on the  Siemens industrial security webpage https://www.siemens.com/industrialsecurity \n\nFor more information see the associated Siemens security advisory SSA-722010"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-7066",
        "datePublished": "2024-08-12T21:46:38.910Z",
        "dateReserved": "2023-12-21T19:40:53.933Z",
        "dateUpdated": "2025-08-27T20:42:53.230Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34086 (GCVE-0-2024-34086)

    Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 15:19 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V2312.0001 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.1 Affected: 0 , < V14.1.0.13 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.2 Affected: 0 , < V14.2.0.10 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.3 Affected: 0 , < V14.3.0.7 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2312 Affected: 0 , < V2312.0001 (custom)
    Create a notification for this product.
    siemens jt2go Affected: 0 , < V2312.0001 (custom)
        cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < V14.1.0.13 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < 14.2.0.10 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < V2312.0001 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < 14.3.0.7 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "jt2go",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V2312.0001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V14.1.0.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V2312.0001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.3.0.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34086",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T15:19:05.198442Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T18:22:25.821Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.863Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.1.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:55.854Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-34086",
        "datePublished": "2024-05-14T10:03:10.774Z",
        "dateReserved": "2024-04-30T09:05:07.900Z",
        "dateUpdated": "2024-08-02T02:42:59.863Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34085 (GCVE-0-2024-34085)

    Vulnerability from nvd – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 14:07 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V2312.0001 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.1 Affected: 0 , < V14.1.0.13 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.2 Affected: 0 , < V14.2.0.10 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.3 Affected: 0 , < V14.3.0.7 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2312 Affected: 0 , < V2312.0001 (custom)
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 14.1 , < 14.1.0.13 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 14.2 , < 14.2.0.10 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens jt2go Affected: 0 , < 2312.0001 (custom)
        cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 2312 , < 2312.0001 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.13",
                    "status": "affected",
                    "version": "14.1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "14.2",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "jt2go",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "2312.0001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "2312.0001",
                    "status": "affected",
                    "version": "2312",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34085",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T14:07:42.511828Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T18:03:43.492Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.891Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.1.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:54.668Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-34085",
        "datePublished": "2024-05-14T10:03:09.574Z",
        "dateReserved": "2024-04-30T09:05:07.900Z",
        "dateUpdated": "2024-08-02T02:42:59.891Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32637 (GCVE-0-2024-32637)

    Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 13:37 UTC
    CWE
    • CWE-476 - NULL Pointer Dereference
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V2312.0005 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.2 Affected: 0 , < V14.2.0.12 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.3 Affected: 0 , < V14.3.0.10 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2312 Affected: 0 , < V2312.0005 (custom)
    Create a notification for this product.
    siemens ps_iges_parasolid_translator_component Affected: 0 , < v27.1.215 (custom)
        cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ps_iges_parasolid_translator_component",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "v27.1.215 ",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32637",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T13:37:33.414539Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-18T18:07:35.849Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:13:40.086Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476: NULL Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-13T07:54:07.678Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32637",
        "datePublished": "2024-05-14T10:02:44.682Z",
        "dateReserved": "2024-04-16T10:52:15.707Z",
        "dateUpdated": "2024-08-13T07:54:07.678Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32636 (GCVE-0-2024-32636)

    Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 13:37 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V2312.0005 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.2 Affected: 0 , < V14.2.0.12 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.3 Affected: 0 , < V14.3.0.10 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2312 Affected: 0 , < V2312.0005 (custom)
    Create a notification for this product.
    siemens parasolid Affected: 35.1 , < 35.1.256 (custom)
        cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens parasolid Affected: 36.0 , < 36.0.208 (custom)
        cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens parasolid Affected: 36.1 , < 36.1.173 (custom)
        cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "parasolid",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "35.1.256",
                    "status": "affected",
                    "version": "35.1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "parasolid",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "36.0.208",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "parasolid",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "36.1.173",
                    "status": "affected",
                    "version": "36.1",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32636",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T13:37:41.622204Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:29:19.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:13:40.376Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-13T07:54:06.352Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32636",
        "datePublished": "2024-05-14T10:02:43.480Z",
        "dateReserved": "2024-04-16T10:52:15.707Z",
        "dateUpdated": "2024-08-13T07:54:06.352Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32635 (GCVE-0-2024-32635)

    Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 13:37 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V2312.0005 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.2 Affected: 0 , < V14.2.0.12 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.3 Affected: 0 , < V14.3.0.10 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2312 Affected: 0 , < V2312.0005 (custom)
    Create a notification for this product.
    siemens parasolid Affected: 35.1 , < 35.1.256 (custom)
        cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens parasolid Affected: 36.0 , < 36.0.208 (custom)
        cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens parasolid Affected: 36.1 , < 36.1.173 (custom)
        cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "parasolid",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "35.1.256",
                    "status": "affected",
                    "version": "35.1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "parasolid",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "36.0.208",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "parasolid",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "36.1.173",
                    "status": "affected",
                    "version": "36.1",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32635",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T13:37:49.970409Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T17:27:51.096Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:13:40.417Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-13T07:54:05.071Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-32635",
        "datePublished": "2024-05-14T10:02:42.291Z",
        "dateReserved": "2024-04-16T10:52:15.707Z",
        "dateUpdated": "2024-08-13T07:54:05.071Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-32454 (GCVE-0-2025-32454)

    Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-06-10 15:17
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 14:10 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-32454",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T14:10:31.587086Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T14:12:07.157Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0004",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.14), Teamcenter Visualization V2312 (All versions \u003c V2312.0010), Teamcenter Visualization V2406 (All versions \u003c V2406.0008), Teamcenter Visualization V2412 (All versions \u003c V2412.0004), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-10T15:17:24.833Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-542540.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-486186.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-32454",
        "datePublished": "2025-05-13T09:38:44.621Z",
        "dateReserved": "2025-04-08T15:46:35.199Z",
        "dateUpdated": "2025-06-10T15:17:24.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-27438 (GCVE-0-2025-27438)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:26
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:26 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27438",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:26:38.797340Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:26:49.545Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:31.489Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-27438",
        "datePublished": "2025-03-11T09:48:31.489Z",
        "dateReserved": "2025-02-25T16:39:12.235Z",
        "dateUpdated": "2025-03-11T13:26:49.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23402 (GCVE-0-2025-23402)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:29
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 14:28 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23402",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:28:48.184791Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:29:22.710Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416: Use After Free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:18.241Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23402",
        "datePublished": "2025-03-11T09:48:18.241Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T14:29:22.710Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23401 (GCVE-0-2025-23401)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:31
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 14:30 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23401",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:30:32.123564Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:31:03.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:16.806Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23401",
        "datePublished": "2025-03-11T09:48:16.806Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T14:31:03.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23400 (GCVE-0-2025-23400)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 14:59
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 14:57 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23400",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T14:57:36.559116Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T14:59:33.908Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:15.383Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23400",
        "datePublished": "2025-03-11T09:48:15.383Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T14:59:33.908Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23399 (GCVE-0-2025-23399)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 15:05
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 15:02 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23399",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T15:02:55.935480Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T15:05:09.830Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:13.954Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23399",
        "datePublished": "2025-03-11T09:48:13.954Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T15:05:09.830Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23398 (GCVE-0-2025-23398)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:45
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:45 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23398",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:45:05.413293Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:45:43.215Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:12.525Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23398",
        "datePublished": "2025-03-11T09:48:12.525Z",
        "dateReserved": "2025-01-15T14:20:46.047Z",
        "dateUpdated": "2025-03-11T13:45:43.215Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23397 (GCVE-0-2025-23397)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:48
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:47 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23397",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:47:07.609257Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:48:23.588Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:11.135Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23397",
        "datePublished": "2025-03-11T09:48:11.135Z",
        "dateReserved": "2025-01-15T14:20:46.046Z",
        "dateUpdated": "2025-03-11T13:48:23.588Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23396 (GCVE-0-2025-23396)

    Vulnerability from cvelistv5 – Published: 2025-03-11 09:48 – Updated: 2025-03-11 13:49
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-11 13:49 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23396",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-11T13:49:04.408654Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-11T13:49:18.776Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0009",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2406",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406.0007",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-11T09:48:09.716Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-23396",
        "datePublished": "2025-03-11T09:48:09.716Z",
        "dateReserved": "2025-01-15T14:20:46.046Z",
        "dateUpdated": "2025-03-11T13:49:18.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-53242 (GCVE-0-2024-53242)

    Vulnerability from cvelistv5 – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-12-10 15:17 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-53242",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-10T15:17:17.154033Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-10T17:17:29.175Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0016",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-10T13:54:13.403Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-53242",
        "datePublished": "2024-12-10T13:54:13.403Z",
        "dateReserved": "2024-11-19T17:51:57.294Z",
        "dateUpdated": "2024-12-10T17:17:29.175Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-53041 (GCVE-0-2024-53041)

    Vulnerability from cvelistv5 – Published: 2024-12-10 13:54 – Updated: 2024-12-10 17:17
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-12-10 15:17 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-53041",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-10T15:17:30.639993Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-10T17:17:19.652Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2302",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2302.0016",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation V2404",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2404.0005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-10T13:54:12.113Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-53041",
        "datePublished": "2024-12-10T13:54:12.113Z",
        "dateReserved": "2024-11-19T16:38:17.725Z",
        "dateUpdated": "2024-12-10T17:17:19.652Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-7066 (GCVE-0-2023-7066)

    Vulnerability from cvelistv5 – Published: 2024-08-12 21:46 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read
    Summary
    The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-14 13:56 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V14.3.0.8 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization Affected: 0 , < V14.1.0.14 (custom)
    Affected: 0 , < V14.2.0.10 (custom)
    Affected: 0 , < V14.3.0.8 (custom)
    Affected: 0 , < V2312.0002 (custom)
    Create a notification for this product.
    siemens jt2go Affected: 0 , < 14.3.0.8 (custom)
        cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < 14.1.0.14 (custom)
    Affected: 0 , < 14.2.0.10 (custom)
    Affected: 0 , < 14.3.0.8 (custom)
    Affected: 0 , < 2312.0002 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "jt2go",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.1.0.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "14.3.0.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "2312.0002",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-7066",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-14T13:56:38.749766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:53.230Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Teamcenter Visualization",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.1.0.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V14.2.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V14.3.0.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V2312.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "MoyunSec reported this vulnerability to Siemens."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
                }
              ],
              "value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-12T21:46:38.910Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722010.html"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\nSiemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\u003c/p\u003e\u003cul\u003e\u003cli\u003eTeamcenter Visualization V14.1: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.1.0.14 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.2: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.2.0.10 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eJT2Go: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.3: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V2312: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV2312.0002 or later version\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\nFor more information see the associated Siemens security advisory SSA-722010\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\n\n  *  Teamcenter Visualization V14.1: Update to  V14.1.0.14 or later version https://support.sw.siemens.com/ \n  *  Teamcenter Visualization V14.2: Update to  V14.2.0.10 or later version https://support.sw.siemens.com/ \n  *  JT2Go: Update to  V14.3.0.8 or later version https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/ \n  *  Teamcenter Visualization V14.3: Update to  V14.3.0.8 or later version https://support.sw.siemens.com/ \n  *  Teamcenter Visualization V2312: Update to  V2312.0002 or later version https://support.sw.siemens.com/ \n\n\n\nFor more information see the associated Siemens security advisory SSA-722010"
            }
          ],
          "source": {
            "advisory": "ICSA-24-193-03",
            "discovery": "EXTERNAL"
          },
          "title": "Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eTo reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\u003cbr\u003e\u003c/p\u003e\u003cul\u003e\n\u003c/ul\u003e\n\u003cp\u003eAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eSiemens\u0027 operational guidelines for industrial security\u003c/a\u003e and following recommendations in the product manuals.\u003c/p\u003e\n\u003cp\u003eAdditional information on industrial security by Siemens can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens industrial security webpage\u003c/a\u003e\u003c/p\u003eFor more information see the associated Siemens security advisory SSA-722010\n\n\u003cbr\u003e"
                }
              ],
              "value": "To reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\n\n\n\n\n\n\nAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to  Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security  and following recommendations in the product manuals.\n\n\nAdditional information on industrial security by Siemens can be found on the  Siemens industrial security webpage https://www.siemens.com/industrialsecurity \n\nFor more information see the associated Siemens security advisory SSA-722010"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-7066",
        "datePublished": "2024-08-12T21:46:38.910Z",
        "dateReserved": "2023-12-21T19:40:53.933Z",
        "dateUpdated": "2025-08-27T20:42:53.230Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34086 (GCVE-0-2024-34086)

    Vulnerability from cvelistv5 – Published: 2024-05-14 10:03 – Updated: 2024-08-02 02:42
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 15:19 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens JT2Go Affected: 0 , < V2312.0001 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.1 Affected: 0 , < V14.1.0.13 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.2 Affected: 0 , < V14.2.0.10 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V14.3 Affected: 0 , < V14.3.0.7 (custom)
    Create a notification for this product.
    Siemens Teamcenter Visualization V2312 Affected: 0 , < V2312.0001 (custom)
    Create a notification for this product.
    siemens jt2go Affected: 0 , < V2312.0001 (custom)
        cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < V14.1.0.13 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < 14.2.0.10 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < V2312.0001 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens teamcenter_visualization Affected: 0 , < 14.3.0.7 (custom)
        cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "jt2go",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V2312.0001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V14.1.0.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.2.0.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V2312.0001",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "teamcenter_visualization",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "14.3.0.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34086",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T15:19:05.198442Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-06T18:22:25.821Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.863Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.1.0.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.2.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V14.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V14.3.0.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter Visualization V2312",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-15T07:24:55.854Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-34086",
        "datePublished": "2024-05-14T10:03:10.774Z",
        "dateReserved": "2024-04-30T09:05:07.900Z",
        "dateUpdated": "2024-08-02T02:42:59.863Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }