Search criteria
114 vulnerabilities found for parasolid by siemens
CVE-2024-54091 (GCVE-0-2024-54091)
Vulnerability from nvd – Published: 2024-12-10 13:54 – Updated: 2025-04-08 08:22- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 12
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54091",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:15:24.096235Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:59.464Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 12), Solid Edge SE2025 (All versions \u003c V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T08:22:23.402Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-672923.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-54091",
"datePublished": "2024-12-10T13:54:17.315Z",
"dateReserved": "2024-11-28T12:05:26.694Z",
"dateUpdated": "2025-04-08T08:22:23.402Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32637 (GCVE-0-2024-32637)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54- CWE-476 - NULL Pointer Dereference
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ps_iges_parasolid_translator_component",
"vendor": "siemens",
"versions": [
{
"lessThan": "v27.1.215 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:33.414539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T18:07:35.849Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.086Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:07.678Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32637",
"datePublished": "2024-05-14T10:02:44.682Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:07.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32636 (GCVE-0-2024-32636)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:41.622204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:29:19.950Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:06.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32636",
"datePublished": "2024-05-14T10:02:43.480Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:06.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32635 (GCVE-0-2024-32635)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:49.970409Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:27:51.096Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:05.071Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32635",
"datePublished": "2024-05-14T10:02:42.291Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:05.071Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31980 (GCVE-0-2024-31980)
Vulnerability from nvd – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:59- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.256
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.210",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.185",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:39:14.173926Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:09:32.754Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:59:50.660Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.256",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.210",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.185",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.1 (All versions \u003c V35.1.256), Parasolid V36.0 (All versions \u003c V36.0.210), Parasolid V36.1 (All versions \u003c V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:15.740Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-31980",
"datePublished": "2024-05-14T10:02:27.405Z",
"dateReserved": "2024-04-08T12:20:23.712Z",
"dateUpdated": "2024-08-02T01:59:50.660Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26276 (GCVE-0-2024-26276)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54- CWE-770 - Allocation of Resources Without Limits or Throttling
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.207",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.147",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:40:25.505191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:53:58.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:02.376Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26276",
"datePublished": "2024-04-09T08:34:37.744Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:02.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26275 (GCVE-0-2024-26275)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "14.2",
"versionType": "custom"
},
{
"lessThan": "14.3.0.9",
"status": "affected",
"version": "14.3",
"versionType": "custom"
},
{
"lessThan": "2312.0004",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T15:24:40.222186Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:33:02.344Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:19.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:00.911Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26275",
"datePublished": "2024-04-09T08:34:36.604Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:00.911Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22043 (GCVE-0-2024-22043)
Vulnerability from nvd – Published: 2024-02-13 09:00 – Updated: 2024-08-01 22:35- CWE-476 - NULL Pointer Dereference
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 |
Affected:
0 , < V35.0.251
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22043",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T20:17:50.302341Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:55.873Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:35:34.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.0.251",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.170",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.251), Parasolid V35.1 (All versions \u003c V35.1.170). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XT files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-13T09:00:08.086Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-22043",
"datePublished": "2024-02-13T09:00:08.086Z",
"dateReserved": "2024-01-04T13:24:07.552Z",
"dateUpdated": "2024-08-01T22:35:34.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-49125 (GCVE-0-2023-49125)
Vulnerability from nvd – Published: 2024-02-13 08:59 – Updated: 2025-05-07 21:13- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 |
Affected:
0 , < V35.0.263
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:29.325Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-49125",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T15:41:44.834147Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T21:13:43.727Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.0.263",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.252",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.198",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V223.0 Update 11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.263), Parasolid V35.1 (All versions \u003c V35.1.252), Parasolid V36.0 (All versions \u003c V36.0.198), Solid Edge SE2023 (All versions \u003c V223.0 Update 11), Solid Edge SE2024 (All versions \u003c V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:23:49.243Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-49125",
"datePublished": "2024-02-13T08:59:57.813Z",
"dateReserved": "2023-11-22T14:43:13.524Z",
"dateUpdated": "2025-05-07T21:13:43.727Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45601 (GCVE-0-2023-45601)
Vulnerability from nvd – Published: 2023-10-10 10:21 – Updated: 2024-09-19 14:07- CWE-121 - Stack-based Buffer Overflow
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 |
Affected:
All versions < V35.0.262
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:21:16.597Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:07:38.593206Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:07:50.300Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.262"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.250"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V36.0.169"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0009"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0003"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.262), Parasolid V35.1 (All versions \u003c V35.1.250), Parasolid V36.0 (All versions \u003c V36.0.169), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0009), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:47.253Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-45601",
"datePublished": "2023-10-10T10:21:47.253Z",
"dateReserved": "2023-10-09T09:36:15.785Z",
"dateUpdated": "2024-09-19T14:07:50.300Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-54091 (GCVE-0-2024-54091)
Vulnerability from cvelistv5 – Published: 2024-12-10 13:54 – Updated: 2025-04-08 08:22- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2024 |
Affected:
0 , < V224.0 Update 12
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54091",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-10T15:15:24.096235Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T17:17:59.464Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions \u003c V224.0 Update 12), Solid Edge SE2025 (All versions \u003c V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T08:22:23.402Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-979056.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-672923.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-54091",
"datePublished": "2024-12-10T13:54:17.315Z",
"dateReserved": "2024-11-28T12:05:26.694Z",
"dateUpdated": "2025-04-08T08:22:23.402Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32637 (GCVE-0-2024-32637)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54- CWE-476 - NULL Pointer Dereference
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ps_iges_parasolid_translator_component",
"vendor": "siemens",
"versions": [
{
"lessThan": "v27.1.215 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:33.414539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T18:07:35.849Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.086Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:07.678Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32637",
"datePublished": "2024-05-14T10:02:44.682Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:07.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32636 (GCVE-0-2024-32636)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:41.622204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:29:19.950Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:06.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32636",
"datePublished": "2024-05-14T10:02:43.480Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:06.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32635 (GCVE-0-2024-32635)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-13 07:54- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0005
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:49.970409Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:27:51.096Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:05.071Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32635",
"datePublished": "2024-05-14T10:02:42.291Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:05.071Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31980 (GCVE-0-2024-31980)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 01:59- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.1 |
Affected:
0 , < V35.1.256
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.210",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.185",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:39:14.173926Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:09:32.754Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:59:50.660Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.256",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.210",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.185",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.1 (All versions \u003c V35.1.256), Parasolid V36.0 (All versions \u003c V36.0.210), Parasolid V36.1 (All versions \u003c V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:15.740Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-489698.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-31980",
"datePublished": "2024-05-14T10:02:27.405Z",
"dateReserved": "2024-04-08T12:20:23.712Z",
"dateUpdated": "2024-08-02T01:59:50.660Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26276 (GCVE-0-2024-26276)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54- CWE-770 - Allocation of Resources Without Limits or Throttling
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.207",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.147",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:40:25.505191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:53:58.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:02.376Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26276",
"datePublished": "2024-04-09T08:34:37.744Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:02.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26275 (GCVE-0-2024-26275)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-13 07:54- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Affected:
0 , < V2312.0004
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "14.2",
"versionType": "custom"
},
{
"lessThan": "14.3.0.9",
"status": "affected",
"version": "14.3",
"versionType": "custom"
},
{
"lessThan": "2312.0004",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T15:24:40.222186Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:33:02.344Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:19.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:00.911Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26275",
"datePublished": "2024-04-09T08:34:36.604Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:00.911Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22043 (GCVE-0-2024-22043)
Vulnerability from cvelistv5 – Published: 2024-02-13 09:00 – Updated: 2024-08-01 22:35- CWE-476 - NULL Pointer Dereference
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 |
Affected:
0 , < V35.0.251
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22043",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T20:17:50.302341Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:55.873Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:35:34.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.0.251",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.170",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.251), Parasolid V35.1 (All versions \u003c V35.1.170). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XT files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-13T09:00:08.086Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-22043",
"datePublished": "2024-02-13T09:00:08.086Z",
"dateReserved": "2024-01-04T13:24:07.552Z",
"dateUpdated": "2024-08-01T22:35:34.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-49125 (GCVE-0-2023-49125)
Vulnerability from cvelistv5 – Published: 2024-02-13 08:59 – Updated: 2025-05-07 21:13- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 |
Affected:
0 , < V35.0.263
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:29.325Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-49125",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-13T15:41:44.834147Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T21:13:43.727Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.0.263",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.252",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.198",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V223.0 Update 11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2024",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V224.0 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.263), Parasolid V35.1 (All versions \u003c V35.1.252), Parasolid V36.0 (All versions \u003c V36.0.198), Solid Edge SE2023 (All versions \u003c V223.0 Update 11), Solid Edge SE2024 (All versions \u003c V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:23:49.243Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-49125",
"datePublished": "2024-02-13T08:59:57.813Z",
"dateReserved": "2023-11-22T14:43:13.524Z",
"dateUpdated": "2025-05-07T21:13:43.727Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45601 (GCVE-0-2023-45601)
Vulnerability from cvelistv5 – Published: 2023-10-10 10:21 – Updated: 2024-09-19 14:07- CWE-121 - Stack-based Buffer Overflow
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V35.0 |
Affected:
All versions < V35.0.262
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:21:16.597Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:07:38.593206Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:07:50.300Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.262"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.250"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V36.0.169"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0009"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0003"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.262), Parasolid V35.1 (All versions \u003c V35.1.250), Parasolid V36.0 (All versions \u003c V36.0.169), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0009), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:47.253Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-45601",
"datePublished": "2023-10-10T10:21:47.253Z",
"dateReserved": "2023-10-09T09:36:15.785Z",
"dateUpdated": "2024-09-19T14:07:50.300Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-202310-0157
Vulnerability from variot - Updated: 2024-08-14 13:19A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290). Siemens' parasolid and tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of IGS files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202310-0157",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tecnomatix",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2201.0009"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "36.0.169"
},
{
"model": "tecnomatix",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2201"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.250"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "36.0"
},
{
"model": "tecnomatix",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2302"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.262"
},
{
"model": "tecnomatix",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0003"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "tecnomatix",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Anonymous",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
}
],
"trust": 0.7
},
"cve": "CVE-2023-45601",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-45601",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-45601",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-45601",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-45601",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-45601",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-45601",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2023-45601",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.262), Parasolid V35.1 (All versions \u003c V35.1.250), Parasolid V36.0 (All versions \u003c V36.0.169), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0009), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290). Siemens\u0027 parasolid and tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of IGS files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-45601"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "ZDI",
"id": "ZDI-23-1577"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-45601",
"trust": 3.3
},
{
"db": "SIEMENS",
"id": "SSA-524778",
"trust": 1.8
},
{
"db": "JVN",
"id": "JVNVU98753493",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-21290",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-1577",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"id": "VAR-202310-0157",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.2690208
},
"last_update_date": "2024-08-14T13:19:43.792000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-524778.html"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98753493/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-45601"
},
{
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-524778.html"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-19T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"date": "2023-12-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"date": "2023-10-10T11:15:13.247000",
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-19T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1577"
},
{
"date": "2023-12-22T05:15:00",
"db": "JVNDB",
"id": "JVNDB-2023-013979"
},
{
"date": "2023-10-12T00:44:25.833000",
"db": "NVD",
"id": "CVE-2023-45601"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0tecnomatix\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-013979"
}
],
"trust": 0.8
}
}
VAR-202308-0238
Vulnerability from variot - Updated: 2024-06-11 22:10A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0238",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.184"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.184",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"cve": "CVE-2023-38531",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38531",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38531",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38531",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38531"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38531",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021536",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"id": "VAR-202308-0238",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T22:10:34.568000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38531"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"date": "2023-08-08T10:15:16.317000",
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:49:00",
"db": "JVNDB",
"id": "JVNDB-2023-021536"
},
{
"date": "2024-06-11T12:15:11.907000",
"db": "NVD",
"id": "CVE-2023-38531"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021536"
}
],
"trust": 0.8
}
}
VAR-202308-0241
Vulnerability from variot - Updated: 2024-06-11 21:53A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0241",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.184"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.184",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"cve": "CVE-2023-38529",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38529",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38529",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38529",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38529"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38529",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021534",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"id": "VAR-202308-0241",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T21:53:35.315000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38529"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"date": "2023-08-08T10:15:16.127000",
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:47:00",
"db": "JVNDB",
"id": "JVNDB-2023-021534"
},
{
"date": "2024-06-11T12:15:11.633000",
"db": "NVD",
"id": "CVE-2023-38529"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021534"
}
],
"trust": 0.8
}
}
VAR-202308-0240
Vulnerability from variot - Updated: 2024-06-11 21:49A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0240",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.171"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.171",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"cve": "CVE-2023-38524",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38524",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38524",
"trust": 1.0,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
},
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
],
"trust": 1.0
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.0
},
{
"db": "NVD",
"id": "CVE-2023-38524",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"id": "VAR-202308-0240",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T21:49:47.580000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-476",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-08-08T10:15:15.627000",
"db": "NVD",
"id": "CVE-2023-38524"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-06-11T12:15:10.860000",
"db": "NVD",
"id": "CVE-2023-38524"
}
]
}
}
VAR-202308-0239
Vulnerability from variot - Updated: 2024-06-11 21:37A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0239",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"cve": "CVE-2023-38527",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38527",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38527",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38527",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38527"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38527",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021526",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"id": "VAR-202308-0239",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T21:37:33.070000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38527"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"date": "2023-08-08T10:15:15.923000",
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:45:00",
"db": "JVNDB",
"id": "JVNDB-2023-021526"
},
{
"date": "2024-06-11T12:15:11.363000",
"db": "NVD",
"id": "CVE-2023-38527"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021526"
}
],
"trust": 0.8
}
}
VAR-202308-0235
Vulnerability from variot - Updated: 2024-06-11 20:44A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.197), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0235",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.197"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.197",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"cve": "CVE-2023-38528",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38528",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38528",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38528",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.197), Parasolid V35.1 (All versions \u003c V35.1.184), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38528"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38528",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021528",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"id": "VAR-202308-0235",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T20:44:06.833000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38528"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"date": "2023-08-08T10:15:16.023000",
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:46:00",
"db": "JVNDB",
"id": "JVNDB-2023-021528"
},
{
"date": "2024-06-11T12:15:11.500000",
"db": "NVD",
"id": "CVE-2023-38528"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021528"
}
],
"trust": 0.8
}
}
VAR-202308-0236
Vulnerability from variot - Updated: 2024-06-11 20:39A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0236",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.171"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.171",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"cve": "CVE-2023-38525",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38525",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38525",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38525",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38525"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38525",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021522",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"id": "VAR-202308-0236",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T20:39:39.547000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38525"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"date": "2023-08-08T10:15:15.723000",
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:43:00",
"db": "JVNDB",
"id": "JVNDB-2023-021522"
},
{
"date": "2024-06-11T12:15:11.073000",
"db": "NVD",
"id": "CVE-2023-38525"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021522"
}
],
"trust": 0.8
}
}
VAR-202308-0242
Vulnerability from variot - Updated: 2024-06-11 20:29A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0242",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.171"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.171",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"cve": "CVE-2023-38530",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38530",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38530",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38530",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38530"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38530",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021535",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"id": "VAR-202308-0242",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T20:29:19.020000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38530"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"date": "2023-08-08T10:15:16.220000",
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:48:00",
"db": "JVNDB",
"id": "JVNDB-2023-021535"
},
{
"date": "2024-06-11T12:15:11.777000",
"db": "NVD",
"id": "CVE-2023-38530"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021535"
}
],
"trust": 0.8
}
}
VAR-202308-0237
Vulnerability from variot - Updated: 2024-06-11 20:04A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens' parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0237",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.171"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.171",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"cve": "CVE-2023-38526",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38526",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38526",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38526",
"trust": 1.0,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 parasolid and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38526"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38526",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021523",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"id": "VAR-202308-0237",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T20:04:39.157000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38526"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"date": "2023-08-08T10:15:15.817000",
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:44:00",
"db": "JVNDB",
"id": "JVNDB-2023-021523"
},
{
"date": "2024-06-11T12:15:11.213000",
"db": "NVD",
"id": "CVE-2023-38526"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021523"
}
],
"trust": 0.8
}
}
VAR-202308-0234
Vulnerability from variot - Updated: 2024-06-11 19:29A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition. Siemens' parasolid and Teamcenter Visualization Exists in a vulnerability in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-0234",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.6"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1.258"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0.254"
},
{
"model": "parasolid",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1.171"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "34.1"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.3"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.1.0.11"
},
{
"model": "parasolid",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "35.1"
},
{
"model": "parasolid",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "34.1.258",
"versionStartIncluding": "34.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.0.254",
"versionStartIncluding": "35.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.2.0.6",
"versionStartIncluding": "14.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "35.1.171",
"versionStartIncluding": "35.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.1.0.11",
"versionStartIncluding": "14.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.3.0.3",
"versionStartIncluding": "14.3",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"cve": "CVE-2023-38532",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 5.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-38532",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38532",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-38532",
"trust": 1.0,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Parasolid V34.1 (All versions \u003c V34.1.258), Parasolid V35.0 (All versions \u003c V35.0.254), Parasolid V35.1 (All versions \u003c V35.1.171), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition. Siemens\u0027 parasolid and Teamcenter Visualization Exists in a vulnerability in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38532"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38532",
"trust": 2.6
},
{
"db": "SIEMENS",
"id": "SSA-407785",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-222-06",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90056839",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021537",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"id": "VAR-202308-0234",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2024-06-11T19:29:50.522000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-770",
"trust": 1.0
},
{
"problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90056839/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38532"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-222-06"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"date": "2023-08-08T10:15:16.403000",
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T06:50:00",
"db": "JVNDB",
"id": "JVNDB-2023-021537"
},
{
"date": "2024-06-11T12:15:12.053000",
"db": "NVD",
"id": "CVE-2023-38532"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0parasolid\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Vulnerability in resource allocation without restrictions or throttling in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021537"
}
],
"trust": 0.8
}
}