32 vulnerabilities found for SCALANCE W1788-2 EEC M12 by Siemens
VAR-202212-1134
Vulnerability from variot - Updated: 2025-01-14 21:45Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to storing passwords in a recoverable format.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-1134",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance w738-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "ruggedcom rm1224 lte\\ eu",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w788-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc208 poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb205-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc626-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xb213-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204-2ba",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w774-1 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m816-1 adsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr326-2c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc622-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xr328-4c wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr324wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m826-2 shdsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-3g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wum763-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp208eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-2ia m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1748-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm408-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm416-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m874-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w774-1 m12 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m876-4",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr524-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1 6ghz",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w786-2 sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr326-2c poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc646-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance w786-2 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance s615",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance wum766-1 6ghz",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr552-12m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-2 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204-2bca dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w786-2ia rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm408-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc636-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xb216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m804pb",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance s615 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-2 eec m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc206-2sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc642-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xp208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w778-1 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2g poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w761-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp208poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w734-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m812-1 adsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w721-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w786-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w778-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance mum856-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w722-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m874-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance mum853-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w1788-2 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w774-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w748-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance wum766-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1 ecc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr526-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb205-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr528-6m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-2 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc632-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance m876-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "ruggedcom rm1224 lte\\ nam",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb213-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204 dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam763-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance s615 eec",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m812-1 adsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m876-4",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance s615",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte eu",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-622-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-636-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte nam",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m816-1 adsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance mum856-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m876-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc626-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m874-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-642-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance mum853-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m826-2 shdsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m804pb",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-646-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-632-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m874-2",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
}
],
"trust": 0.6
},
"cve": "CVE-2022-46142",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "productcert@siemens.com",
"availabilityImpact": "LOW",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2022-46142",
"impactScore": 4.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2022-46142",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Physical",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 5.7,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2022-023552",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2022-46142",
"trust": 1.0,
"value": "Medium"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2022-46142",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2022-023552",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-3090",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to storing passwords in a recoverable format.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-46142"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-46142",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-413565",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-22-349-04",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU91561630",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023552",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3090",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"id": "VAR-202212-1134",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.638605728125
},
"last_update_date": "2025-01-14T21:45:05.891000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens part of the product Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218339"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-257",
"trust": 1.0
},
{
"problemtype": "CWE-522",
"trust": 1.0
},
{
"problemtype": "Password storage in recoverable form (CWE-257) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91561630/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-46142"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-46142/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
},
{
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"date": "2022-12-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-3090"
},
{
"date": "2022-12-13T16:15:25.067000",
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-29T03:03:00",
"db": "JVNDB",
"id": "JVNDB-2022-023552"
},
{
"date": "2023-03-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-3090"
},
{
"date": "2025-01-14T11:15:11.407000",
"db": "NVD",
"id": "CVE-2022-46142"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Recoverable password storage vulnerability in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023552"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3090"
}
],
"trust": 0.6
}
}
VAR-202212-1136
Vulnerability from variot - Updated: 2025-01-14 21:42Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain a vulnerability related to improper validation of quantities specified in input.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers.
The Siemens SCALANCE M-800/S615 series has an information disclosure vulnerability due to the affected device not properly checking the TFTP block size
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-1136",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance m876-4",
"scope": "lt",
"trust": 1.8,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m812-1 adsl-router",
"scope": "lt",
"trust": 1.2,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m816-1 adsl-router",
"scope": "lt",
"trust": 1.2,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m876-3",
"scope": "lt",
"trust": 1.2,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance mum856-1",
"scope": "lt",
"trust": 1.2,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance w738-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "ruggedcom rm1224 lte\\ eu",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w788-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc208 poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb205-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc626-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xb213-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204-2ba",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w774-1 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m816-1 adsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr326-2c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc622-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xr328-4c wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr324wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m826-2 shdsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-3g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wum763-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp208eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-2ia m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1748-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm408-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm416-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m874-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w774-1 m12 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m876-4",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr524-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1 6ghz",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w786-2 sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr326-2c poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc646-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance w786-2 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance s615",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance wum766-1 6ghz",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr552-12m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-2 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204-2bca dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w786-2ia rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm408-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc636-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xb216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m804pb",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance s615 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-2 eec m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc206-2sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc642-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xp208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w778-1 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2g poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w761-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp208poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w734-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m812-1 adsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w721-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w786-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w778-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance mum856-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w722-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m874-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance mum853-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w1788-2 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w774-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w748-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance wum766-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1 ecc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr526-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb205-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr528-6m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-2 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc632-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance m876-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "ruggedcom rm1224 lte\\ nam",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb213-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204 dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam763-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance s615 eec",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m812-1 adsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m876-4",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance s615",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte eu",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-622-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-636-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte nam",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m816-1 adsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance mum856-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m876-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc626-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m874-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-642-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance mum853-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m826-2 shdsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m804pb",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-646-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-632-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m874-2",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte eu",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "ruggedcom rm1224 lte nam",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m804pb",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m826-2 shdsl-router",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m874-2",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance m874-3",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance mum853-1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance s615",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "scalance s615 eec",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
}
],
"trust": 0.6
},
"cve": "CVE-2022-46143",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.4,
"id": "CNVD-2023-97251",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.2,
"id": "CVE-2022-46143",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 2.7,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2022-023553",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2022-46143",
"trust": 1.0,
"value": "Medium"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2022-46143",
"trust": 1.0,
"value": "LOW"
},
{
"author": "OTHER",
"id": "JVNDB-2022-023553",
"trust": 0.8,
"value": "Low"
},
{
"author": "CNVD",
"id": "CNVD-2023-97251",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-3089",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain a vulnerability related to improper validation of quantities specified in input.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. \n\r\n\r\nThe Siemens SCALANCE M-800/S615 series has an information disclosure vulnerability due to the affected device not properly checking the TFTP block size",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-46143"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "CNVD",
"id": "CNVD-2023-97251"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-46143",
"trust": 3.8
},
{
"db": "SIEMENS",
"id": "SSA-413565",
"trust": 2.4
},
{
"db": "SIEMENS",
"id": "SSA-180704",
"trust": 1.6
},
{
"db": "ICS CERT",
"id": "ICSA-22-349-04",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU91561630",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-97251",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3089",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"id": "VAR-202212-1136",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
}
],
"trust": 1.238605728125
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
}
]
},
"last_update_date": "2025-01-14T21:42:37.301000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SCALANCE M-800/S615 series information leakage vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/500346"
},
{
"title": "Siemens part of the product Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218338"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-1284",
"trust": 1.0
},
{
"problemtype": "Improper validation of quantity specified in input (CWE-1284) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"trust": 1.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91561630/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-46143"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-46143/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
},
{
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-12-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"date": "2023-11-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"date": "2022-12-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-3089"
},
{
"date": "2022-12-13T16:15:25.137000",
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-12-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-97251"
},
{
"date": "2023-11-29T03:03:00",
"db": "JVNDB",
"id": "JVNDB-2022-023553"
},
{
"date": "2022-12-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-3089"
},
{
"date": "2025-01-14T11:15:11.840000",
"db": "NVD",
"id": "CVE-2022-46143"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerability in multiple Siemens products related to improper validation of quantities specified in inputs",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023553"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3089"
}
],
"trust": 0.6
}
}
VAR-202212-1133
Vulnerability from variot - Updated: 2025-01-14 19:58Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to the use of cryptographic algorithms.Information may be obtained
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-1133",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance w738-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "ruggedcom rm1224 lte\\ eu",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w788-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc208 poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb205-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc626-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xb213-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204-2ba",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w774-1 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m816-1 adsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr326-2c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc622-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xr328-4c wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr324wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m826-2 shdsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-3g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wum763-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp208eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-2ia m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1748-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm408-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm416-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m874-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w774-1 m12 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m876-4",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr524-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1 6ghz",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w786-2 sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr326-2c poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc646-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance w786-2 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc224",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance s615",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance wum766-1 6ghz",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr552-12m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-2 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204-2bca dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w786-2ia rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm408-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc636-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xb216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance m804pb",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance s615 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w1788-2 eec m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc206-2sfp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc642-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance xp208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w778-1 m12 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2g poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w761-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp208poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w734-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m812-1 adsl-router",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w721-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w786-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w778-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance mum856-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208 eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w722-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m874-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance mum853-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w1788-2 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w774-1 rj45",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w748-1 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance wum766-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam766-1 ecc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr526-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb205-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "siplus net scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr528-6m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w788-2 m12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc206-2sfp eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance sc632-2c",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.3"
},
{
"model": "scalance m876-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "ruggedcom rm1224 lte\\ nam",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb213-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf204 dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance wam763-1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "scalance s615 eec",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m812-1 adsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m876-4",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance s615",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte eu",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-622-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-636-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "ruggedcom rm1224 lte nam",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m816-1 adsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance mum856-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m876-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc626-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m874-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-642-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance mum853-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m826-2 shdsl-router",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m804pb",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-646-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance sc-632-2c",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m874-2",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
}
],
"trust": 0.6
},
"cve": "CVE-2022-46140",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2022-46140",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2022-023551",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2022-46140",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2022-46140",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2022-023551",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-3091",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to the use of cryptographic algorithms.Information may be obtained",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-46140"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-46140",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-413565",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-22-349-04",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU91561630",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-023551",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3091",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"id": "VAR-202212-1133",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.638605728125
},
"last_update_date": "2025-01-14T19:58:57.346000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens part of the product Fixes for encryption problem vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218340"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-327",
"trust": 1.0
},
{
"problemtype": "Use of incomplete or dangerous cryptographic algorithms (CWE-327) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91561630/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-46140"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-46140/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
},
{
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"date": "2022-12-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-3091"
},
{
"date": "2022-12-13T16:15:25.007000",
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-29T03:03:00",
"db": "JVNDB",
"id": "JVNDB-2022-023551"
},
{
"date": "2022-12-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-3091"
},
{
"date": "2025-01-14T11:15:10.960000",
"db": "NVD",
"id": "CVE-2022-46140"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerabilities related to the use of cryptographic algorithms in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-023551"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-3091"
}
],
"trust": 0.6
}
}
VAR-202204-0217
Vulnerability from variot - Updated: 2024-11-23 22:36A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11 standard
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202204-0217",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance w1788-1 m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2 eec m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2 m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2ia m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
}
],
"trust": 0.6
},
"cve": "CVE-2022-27481",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 5.7,
"confidentialityImpact": "NONE",
"exploitabilityScore": 5.5,
"id": "CVE-2022-27481",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.1,
"vectorString": "AV:A/AC:M/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2022-28499",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.6,
"id": "CVE-2022-27481",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-27481",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2022-28499",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202204-3127",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2022-27481",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "VULMON",
"id": "CVE-2022-27481"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
},
{
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11 standard",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-27481"
},
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "VULMON",
"id": "CVE-2022-27481"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-392912",
"trust": 2.3
},
{
"db": "NVD",
"id": "CVE-2022-27481",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-22-104-08",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2022-28499",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022041912",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3127",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-27481",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "VULMON",
"id": "CVE-2022-27481"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
},
{
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"id": "VAR-202204-0217",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
}
]
},
"last_update_date": "2024-11-23T22:36:51.480000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability (CNVD-2022-28499)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/329186"
},
{
"title": "Siemens SCALANCE Repair measures for the competition condition problem loophole",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=190121"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-362",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022041912"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-08"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-27481/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/362.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-08"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "VULMON",
"id": "CVE-2022-27481"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
},
{
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"db": "VULMON",
"id": "CVE-2022-27481"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
},
{
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"date": "2022-04-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-27481"
},
{
"date": "2022-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-3127"
},
{
"date": "2022-04-12T09:15:15.150000",
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28499"
},
{
"date": "2022-04-19T00:00:00",
"db": "VULMON",
"id": "CVE-2022-27481"
},
{
"date": "2022-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-3127"
},
{
"date": "2024-11-21T06:55:48.617000",
"db": "NVD",
"id": "CVE-2022-27481"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability (CNVD-2022-28499)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28499"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "competition condition problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3127"
}
],
"trust": 0.6
}
}
VAR-202204-0216
Vulnerability from variot - Updated: 2024-11-23 22:36A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11 standard
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202204-0216",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance w1788-1 m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2 eec m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2 m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2ia m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
}
],
"trust": 0.6
},
"cve": "CVE-2022-28329",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CVE-2022-28329",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.1,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2022-28498",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2022-28329",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-28329",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2022-28498",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202204-3124",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2022-28329",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "VULMON",
"id": "CVE-2022-28329"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
},
{
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11 standard",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-28329"
},
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "VULMON",
"id": "CVE-2022-28329"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-28329",
"trust": 2.3
},
{
"db": "SIEMENS",
"id": "SSA-392912",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-22-104-08",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2022-28498",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022041912",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3124",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-28329",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "VULMON",
"id": "CVE-2022-28329"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
},
{
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"id": "VAR-202204-0216",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
}
]
},
"last_update_date": "2024-11-23T22:36:51.456000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability (CNVD-2022-28498)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/329191"
},
{
"title": "Siemens SCALANCE Enter the fix for the verification error vulnerability",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=190120"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022041912"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-28329/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-08"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-08"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "VULMON",
"id": "CVE-2022-28329"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
},
{
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"db": "VULMON",
"id": "CVE-2022-28329"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
},
{
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"date": "2022-04-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-28329"
},
{
"date": "2022-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-3124"
},
{
"date": "2022-04-12T09:15:15.240000",
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28498"
},
{
"date": "2022-04-19T00:00:00",
"db": "VULMON",
"id": "CVE-2022-28329"
},
{
"date": "2022-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-3124"
},
{
"date": "2024-11-21T06:57:10.490000",
"db": "NVD",
"id": "CVE-2022-28329"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability (CNVD-2022-28498)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28498"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "input validation error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3124"
}
],
"trust": 0.6
}
}
VAR-202204-0215
Vulnerability from variot - Updated: 2024-11-23 22:36A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11 standard
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202204-0215",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance w1788-1 m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2 eec m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2 m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
},
{
"model": "scalance w1788-2ia m12",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "3.0.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
}
],
"trust": 0.6
},
"cve": "CVE-2022-28328",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2022-28328",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 1.1,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2022-28500",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-28328",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-28328",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-28500",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202204-3125",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2022-28328",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "VULMON",
"id": "CVE-2022-28328"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
},
{
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11 standard",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-28328"
},
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "VULMON",
"id": "CVE-2022-28328"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-28328",
"trust": 2.3
},
{
"db": "SIEMENS",
"id": "SSA-392912",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-22-104-08",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2022-28500",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022041912",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3125",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-28328",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "VULMON",
"id": "CVE-2022-28328"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
},
{
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"id": "VAR-202204-0215",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
}
]
},
"last_update_date": "2024-11-23T22:36:51.431000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/329181"
},
{
"title": "Siemens SCALANCE Enter the fix for the verification error vulnerability",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=189478"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022041912"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-28328/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-08"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-08"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "VULMON",
"id": "CVE-2022-28328"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
},
{
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"db": "VULMON",
"id": "CVE-2022-28328"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
},
{
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"date": "2022-04-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-28328"
},
{
"date": "2022-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-3125"
},
{
"date": "2022-04-12T09:15:15.197000",
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28500"
},
{
"date": "2022-04-19T00:00:00",
"db": "VULMON",
"id": "CVE-2022-28328"
},
{
"date": "2022-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-3125"
},
{
"date": "2024-11-21T06:57:10.377000",
"db": "NVD",
"id": "CVE-2022-28328"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SCALANCE W-1700 (11ac) Series Denial of Service Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28500"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "input validation error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-3125"
}
],
"trust": 0.6
}
}
CVE-2024-30191 (GCVE-0-2024-30191)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-27 19:42- CWE-290 - Authentication Bypass by Spoofing
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1748-1_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1748-1_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-1_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-2_eec_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-2_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-2ia_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30191",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T19:49:06.194305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-27T19:42:29.913Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 3 \"Override client\u2019s security context\" of CVE-2022-47522.\r\n\r\nAffected devices can be tricked into associating a newly negotiated, attacker-controlled, security context with frames belonging to a victim. This could allow a physically proximate attacker to decrypt frames meant for the victim."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-09T08:34:42.970Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30191",
"datePublished": "2024-04-09T08:34:42.970Z",
"dateReserved": "2024-03-25T10:25:29.901Z",
"dateUpdated": "2024-08-27T19:42:29.913Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30190 (GCVE-0-2024-30190)
Vulnerability from nvd – Published: 2024-04-09 08:34 – Updated: 2024-08-02 01:25- CWE-290 - Authentication Bypass by Spoofing
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30190",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-12T18:59:59.427449Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:38:46.608Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 2 \"Abuse the queue for network disruptions\" of CVE-2022-47522.\r\n\r\nAffected devices can be tricked into enabling its power-saving mechanisms for a victim client. This could allow a physically proximate attacker to execute disconnection and denial-of-service attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-09T08:34:41.545Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30190",
"datePublished": "2024-04-09T08:34:41.545Z",
"dateReserved": "2024-03-25T10:25:29.901Z",
"dateUpdated": "2024-08-02T01:25:03.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46143 (GCVE-0-2022-46143)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-01-14 10:27- CWE-1284 - Improper Validation of Specified Quantity in Input
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284: Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:11.064Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46143",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-11-28T00:00:00",
"dateUpdated": "2025-01-14T10:27:11.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46142 (GCVE-0-2022-46142)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:43- CWE-257 - Storing Passwords in a Recoverable Format
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.321Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46142",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:14:43.501518Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:43:06.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-257",
"description": "CWE-257: Storing Passwords in a Recoverable Format",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:07.533Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46142",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-28T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:43:06.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46140 (GCVE-0-2022-46140)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:43- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.297Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46140",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:14:47.809679Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:43:14.878Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:03.863Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46140",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-28T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:43:14.878Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31765 (GCVE-0-2022-31765)
Vulnerability from nvd – Published: 2022-10-11 00:00 – Updated: 2025-04-21 13:48- CWE-862 - Missing Authorization
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.033Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-31765",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:51.272836Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:48:35.929Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly authorize the change password function of the web interface.\r\nThis could allow low privileged users to escalate their privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:02:25.347Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-31765",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-05-27T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:48:35.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36325 (GCVE-0-2022-36325)
Vulnerability from nvd – Published: 2022-08-10 11:18 – Updated: 2025-04-21 13:50- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36325",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:55.607913Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:50:56.289Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:04.880Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36325",
"datePublished": "2022-08-10T11:18:45.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:50:56.289Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36324 (GCVE-0-2022-36324)
Vulnerability from nvd – Published: 2022-08-10 11:18 – Updated: 2025-04-21 13:51- CWE-770 - Allocation of Resources Without Limits or Throttling
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.354Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36324",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:22.854913Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:51:04.290Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:02.321Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36324",
"datePublished": "2022-08-10T11:18:39.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:51:04.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36323 (GCVE-0-2022-36323)
Vulnerability from nvd – Published: 2022-08-10 11:18 – Updated: 2025-05-20 19:08- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.366Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36323",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-20T19:08:22.133863Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-20T19:08:26.770Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:20:59.701Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36323",
"datePublished": "2022-08-10T11:18:33.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2025-05-20T19:08:26.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28329 (GCVE-0-2022-28329)
Vulnerability from nvd – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:48- CWE-20 - Improper Input Validation
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:38.032Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-28329",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-28329",
"datePublished": "2022-04-12T09:08:07",
"dateReserved": "2022-04-01T00:00:00",
"dateUpdated": "2024-08-03T05:48:38.032Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28328 (GCVE-0-2022-28328)
Vulnerability from nvd – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:48- CWE-20 - Improper Input Validation
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:38.169Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:06",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-28328",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-28328",
"datePublished": "2022-04-12T09:08:06",
"dateReserved": "2022-04-01T00:00:00",
"dateUpdated": "2024-08-03T05:48:38.169Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27481 (GCVE-0-2022-27481)
Vulnerability from nvd – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:25- CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:25:32.886Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-362",
"description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:04",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-27481",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-27481",
"datePublished": "2022-04-12T09:08:04",
"dateReserved": "2022-03-21T00:00:00",
"dateUpdated": "2024-08-03T05:25:32.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30191 (GCVE-0-2024-30191)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-27 19:42- CWE-290 - Authentication Bypass by Spoofing
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1748-1_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1748-1_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-1_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-2_eec_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-2_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scalance_w1788-2ia_m12_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30191",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T19:49:06.194305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-27T19:42:29.913Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 3 \"Override client\u2019s security context\" of CVE-2022-47522.\r\n\r\nAffected devices can be tricked into associating a newly negotiated, attacker-controlled, security context with frames belonging to a victim. This could allow a physically proximate attacker to decrypt frames meant for the victim."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-09T08:34:42.970Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30191",
"datePublished": "2024-04-09T08:34:42.970Z",
"dateReserved": "2024-03-25T10:25:29.901Z",
"dateUpdated": "2024-08-27T19:42:29.913Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30190 (GCVE-0-2024-30190)
Vulnerability from cvelistv5 – Published: 2024-04-09 08:34 – Updated: 2024-08-02 01:25- CWE-290 - Authentication Bypass by Spoofing
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-30190",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-12T18:59:59.427449Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:38:46.608Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:25:03.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 2 \"Abuse the queue for network disruptions\" of CVE-2022-47522.\r\n\r\nAffected devices can be tricked into enabling its power-saving mechanisms for a victim client. This could allow a physically proximate attacker to execute disconnection and denial-of-service attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290: Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-09T08:34:41.545Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-30190",
"datePublished": "2024-04-09T08:34:41.545Z",
"dateReserved": "2024-03-25T10:25:29.901Z",
"dateUpdated": "2024-08-02T01:25:03.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46142 (GCVE-0-2022-46142)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:43- CWE-257 - Storing Passwords in a Recoverable Format
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.321Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46142",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:14:43.501518Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:43:06.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-257",
"description": "CWE-257: Storing Passwords in a Recoverable Format",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:07.533Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46142",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-28T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:43:06.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46143 (GCVE-0-2022-46143)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-01-14 10:27- CWE-1284 - Improper Validation of Specified Quantity in Input
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUB762-1 iFeatures",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (ME)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284: Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:11.064Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46143",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-11-28T00:00:00",
"dateUpdated": "2025-01-14T10:27:11.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46140 (GCVE-0-2022-46140)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:43- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.2
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.297Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46140",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:14:47.809679Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:43:14.878Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:03.863Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46140",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-28T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:43:14.878Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31765 (GCVE-0-2022-31765)
Vulnerability from cvelistv5 – Published: 2022-10-11 00:00 – Updated: 2025-04-21 13:48- CWE-862 - Missing Authorization
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.033Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-31765",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:51.272836Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:48:35.929Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly authorize the change password function of the web interface.\r\nThis could allow low privileged users to escalate their privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:02:25.347Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-31765",
"datePublished": "2022-10-11T00:00:00.000Z",
"dateReserved": "2022-05-27T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:48:35.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36325 (GCVE-0-2022-36325)
Vulnerability from cvelistv5 – Published: 2022-08-10 11:18 – Updated: 2025-04-21 13:50- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36325",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:55.607913Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:50:56.289Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:04.880Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36325",
"datePublished": "2022-08-10T11:18:45.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:50:56.289Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36324 (GCVE-0-2022-36324)
Vulnerability from cvelistv5 – Published: 2022-08-10 11:18 – Updated: 2025-04-21 13:51- CWE-770 - Allocation of Resources Without Limits or Throttling
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.354Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36324",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:22.854913Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:51:04.290Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:02.321Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36324",
"datePublished": "2022-08-10T11:18:39.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:51:04.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36323 (GCVE-0-2022-36323)
Vulnerability from cvelistv5 – Published: 2022-08-10 11:18 – Updated: 2025-05-20 19:08- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
All versions < V7.1.2
|
||
|
|
||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.366Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36323",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-20T19:08:22.133863Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-20T19:08:26.770Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex A)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router (Annex B)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (EVDO)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.1.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:20:59.701Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36323",
"datePublished": "2022-08-10T11:18:33.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2025-05-20T19:08:26.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28329 (GCVE-0-2022-28329)
Vulnerability from cvelistv5 – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:48- CWE-20 - Improper Input Validation
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:38.032Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-28329",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-28329",
"datePublished": "2022-04-12T09:08:07",
"dateReserved": "2022-04-01T00:00:00",
"dateUpdated": "2024-08-03T05:48:38.032Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28328 (GCVE-0-2022-28328)
Vulnerability from cvelistv5 – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:48- CWE-20 - Improper Input Validation
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:38.169Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:06",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-28328",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-28328",
"datePublished": "2022-04-12T09:08:06",
"dateReserved": "2022-04-01T00:00:00",
"dateUpdated": "2024-08-03T05:48:38.169Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27481 (GCVE-0-2022-27481)
Vulnerability from cvelistv5 – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:25- CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
All versions < V3.0.0
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:25:32.886Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
},
{
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-362",
"description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:08:04",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-27481",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0.0"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 EEC M12 (All versions \u003c V3.0.0), SCALANCE W1788-2 M12 (All versions \u003c V3.0.0), SCALANCE W1788-2IA M12 (All versions \u003c V3.0.0). Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-27481",
"datePublished": "2022-04-12T09:08:04",
"dateReserved": "2022-03-21T00:00:00",
"dateUpdated": "2024-08-03T05:25:32.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",