Search
Find a vulnerability
Search criteria
7 vulnerabilities
CVE-2026-27869 (GCVE-0-2026-27869)
Vulnerability from cvelistv5 – Published: 2026-06-17 08:13 – Updated: 2026-07-01 11:17
VLAI
Title
WEB SERVICE (HTTP) DENIAL OF SERVICE VIA SLOW HEADERS ON REGESTA SMART HD-PLC OF TELDAT
Summary
An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could, with a Slow Loris attack, cause Denial of Service (DoS) on the web interface of the device. This issue affects Regesta Smart HD-PLC - TLDPH16D2:
11.02.05.10.02.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-770 - Allocation of resources without limits or throttling
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0003/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2026-27869/ | technical-descriptionpatch |
| https://www.teldat.com/es/ | product |
| https://support.teldat.com/images/content/docs/Te… | product |
| https://support.teldat.com/portal/supportcontent?… | patch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Teldat | Regesta Smart HD-PLC - TLDPH16D2 |
Affected:
11.02.05.10.02
Unaffected: 11.02.06.00.02 |
Date Public
2026-06-17 08:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-27869",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-17T14:20:10.059533Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-17T14:20:21.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Regesta Smart HD-PLC - TLDPH16D2",
"vendor": "Teldat",
"versions": [
{
"status": "affected",
"version": "11.02.05.10.02"
},
{
"status": "unaffected",
"version": "11.02.06.00.02"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.05.10.02:*:*:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-06-17T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could, with a Slow Loris attack, cause \u003cb\u003eDenial of Service (DoS)\u003c/b\u003e on the web interface of the device.\u0026nbsp;\u003cspan\u003eT\u003c/span\u003e\u003cspan\u003ehis issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could, with a Slow Loris attack, cause Denial of Service (DoS) on the web interface of the device.\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02."
}
],
"impacts": [
{
"capecId": "CAPEC-227",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-227 Sustained Client Engagement"
}
]
},
{
"capecId": "CAPEC-469",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-469 HTTP DoS"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of resources without limits or throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T11:17:35.841Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0003/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27869/"
},
{
"tags": [
"product"
],
"url": "https://www.teldat.com/es/"
},
{
"tags": [
"product"
],
"url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
},
{
"tags": [
"patch"
],
"url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implement the new version\u0026nbsp;\u003cb\u003e11.02.06.00.02\u003c/b\u003e\u0026nbsp;which solves the security problems detected in the affected version. The end user has to download the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and implement it in the device (\n\u003ca href=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\" title=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e)."
}
],
"value": "The provider has implement the new version\u00a011.02.06.00.02\u00a0which solves the security problems detected in the affected version. The end user has to download the new version in the Teldat - Client Support Portal and implement it in the device (\n https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US )."
}
],
"source": {
"advisory": "HRTU#0003",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2026-02-20T09:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2026-02-22T09:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2026-02-25T09:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-05-29T08:00:00.000Z",
"value": "New version published by the provider"
},
{
"lang": "en",
"time": "2026-06-17T08:00:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "WEB SERVICE (HTTP) DENIAL OF SERVICE VIA SLOW HEADERS ON REGESTA SMART HD-PLC OF TELDAT",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2026-27869",
"datePublished": "2026-06-17T08:13:37.802Z",
"dateReserved": "2026-02-24T08:59:28.139Z",
"dateUpdated": "2026-07-01T11:17:35.841Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-27870 (GCVE-0-2026-27870)
Vulnerability from cvelistv5 – Published: 2026-06-17 08:13 – Updated: 2026-07-01 11:18
VLAI
Title
CROSS-SITE SCRIPTING (XSS) VIA MALICIOUS FILE UPLOAD ON REGESTA SMART HD-PLC OF TELDAT
Summary
An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action IS required) who has the vulnerable software could, introduce arbitrary JavaScript by injecting a Cross-site Scripting (XSS) payload into the 'Hostname' field of the configuration file resulting in a XSS in the path /upgrade/query.php?cmd=p+3%3Bversion. This issue affects Regesta Smart HD-PLC - TLDPH16D2:
11.02.05.10.02.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0003/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2026-27870/ | technical-descriptionpatch |
| https://www.teldat.com/es/ | product |
| https://support.teldat.com/images/content/docs/Te… | product |
| https://support.teldat.com/portal/supportcontent?… | patch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Teldat | Regesta Smart HD-PLC - TLDPH16D2 |
Affected:
11.02.05.10.02
Unaffected: 11.02.06.00.02 |
Date Public
2026-06-17 08:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-27870",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-17T12:47:25.070527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-17T12:47:53.316Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Regesta Smart HD-PLC - TLDPH16D2",
"vendor": "Teldat",
"versions": [
{
"status": "affected",
"version": "11.02.05.10.02"
},
{
"status": "unaffected",
"version": "11.02.06.00.02"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.05.10.02:*:*:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-06-17T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action IS required) who has the vulnerable software could, introduce arbitrary JavaScript by injecting a\u0026nbsp;\u003cb\u003eCross-site Scripting (XSS)\u003c/b\u003e\u0026nbsp; payload into the \u0027\u003ci\u003eHostname\u003c/i\u003e\u0027 field of the configuration file resulting in a\u0026nbsp;XSS\u0026nbsp;in the path \u003ci\u003e\u003cb\u003e/upgrade/query.php?cmd=p+3%3Bversion\u003c/b\u003e\u003c/i\u003e.\u0026nbsp;\u003cspan\u003eT\u003c/span\u003e\u003cspan\u003ehis issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02.\u003c/span\u003e"
}
],
"value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action IS required) who has the vulnerable software could, introduce arbitrary JavaScript by injecting a\u00a0Cross-site Scripting (XSS)\u00a0 payload into the \u0027Hostname\u0027 field of the configuration file resulting in a\u00a0XSS\u00a0in the path /upgrade/query.php?cmd=p+3%3Bversion.\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02."
}
],
"impacts": [
{
"capecId": "CAPEC-242",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-242 Code Injection"
}
]
},
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T11:18:07.193Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0003/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27870/"
},
{
"tags": [
"product"
],
"url": "https://www.teldat.com/es/"
},
{
"tags": [
"product"
],
"url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
},
{
"tags": [
"patch"
],
"url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implement the new version\u0026nbsp;\u003cb\u003e11.02.06.00.02\u003c/b\u003e\u0026nbsp;which solves the security problems detected in the affected version. The end user has to download the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and implement it in the device (\n\u003ca href=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\" title=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e)."
}
],
"value": "The provider has implement the new version\u00a011.02.06.00.02\u00a0which solves the security problems detected in the affected version. The end user has to download the new version in the Teldat - Client Support Portal and implement it in the device (\n https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US )."
}
],
"source": {
"advisory": "HRTU#0003",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2026-02-20T09:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2026-02-22T09:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2026-02-25T09:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-05-29T08:00:00.000Z",
"value": "New version published by the provider"
},
{
"lang": "en",
"time": "2026-06-17T08:00:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "CROSS-SITE SCRIPTING (XSS) VIA MALICIOUS FILE UPLOAD ON REGESTA SMART HD-PLC OF TELDAT",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2026-27870",
"datePublished": "2026-06-17T08:13:37.162Z",
"dateReserved": "2026-02-24T08:59:28.139Z",
"dateUpdated": "2026-07-01T11:18:07.193Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-27868 (GCVE-0-2026-27868)
Vulnerability from cvelistv5 – Published: 2026-06-17 08:13 – Updated: 2026-07-01 11:16
VLAI
Title
PUBLICATION OF SENSITIVE INFORMATION ON REGESTA SMART HD-PLC OF TELDAT
Summary
An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command Version via the path: /upgrade/query.php?cmd=p+3&3Bversion resulting in a information disclosure. This issue affects Regesta Smart HD-PLC - TLDPH16D2:
11.02.05.10.02.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-201 - Insertion of sensitive information into sent data
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0003/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2026-27868/ | technical-descriptionpatch |
| https://www.teldat.com/es/ | product |
| https://support.teldat.com/images/content/docs/Te… | product |
| https://support.teldat.com/portal/supportcontent?… | patch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Teldat | Regesta Smart HD-PLC - TLDPH16D2 |
Affected:
11.02.05.10.02
Unaffected: 11.02.06.00.02 |
Date Public
2026-06-17 08:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-27868",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-17T12:48:11.401061Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-17T12:48:19.633Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Regesta Smart HD-PLC - TLDPH16D2",
"vendor": "Teldat",
"versions": [
{
"status": "affected",
"version": "11.02.05.10.02"
},
{
"status": "unaffected",
"version": "11.02.06.00.02"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.05.10.02:*:*:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-06-17T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command \u003cb\u003eVersion \u003c/b\u003evia the path: \u003ci\u003e/upgrade/query.php?cmd=p+3\u0026amp;3Bversion\u003c/i\u003e\u0026nbsp;resulting in a information disclosure.\u0026nbsp;\u003cspan\u003eT\u003c/span\u003e\u003cspan\u003ehis issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command Version via the path: /upgrade/query.php?cmd=p+3\u00263Bversion\u00a0resulting in a information disclosure.\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02."
}
],
"impacts": [
{
"capecId": "CAPEC-116",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-116 Excavation"
}
]
},
{
"capecId": "CAPEC-54",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-54 Query System for Information"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-201",
"description": "CWE-201 Insertion of sensitive information into sent data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-01T11:16:53.423Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0003/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27868/"
},
{
"tags": [
"product"
],
"url": "https://www.teldat.com/es/"
},
{
"tags": [
"product"
],
"url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
},
{
"tags": [
"patch"
],
"url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implemented the new version\u0026nbsp;\n\u003cb\u003e11.02.06.00.02\u003c/b\u003e\u0026nbsp;\u0026nbsp;which solves the security problems detected in the affected version. The end user has to download the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and implement it in the device (\n\u003ca href=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\" title=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e)."
}
],
"value": "The provider has implemented the new version\u00a0\n11.02.06.00.02\u00a0\u00a0which solves the security problems detected in the affected version. The end user has to download the new version in the Teldat - Client Support Portal and implement it in the device (\n https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US )."
}
],
"source": {
"advisory": "HRTU#0003",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2026-02-20T09:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2026-02-22T09:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2026-02-25T09:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-05-29T08:00:00.000Z",
"value": "New version published by the provider"
},
{
"lang": "en",
"time": "2026-06-17T08:00:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "PUBLICATION OF SENSITIVE INFORMATION ON REGESTA SMART HD-PLC OF TELDAT",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2026-27868",
"datePublished": "2026-06-17T08:13:36.554Z",
"dateReserved": "2026-02-24T08:59:28.139Z",
"dateUpdated": "2026-07-01T11:16:53.423Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-13651 (GCVE-0-2025-13651)
Vulnerability from cvelistv5 – Published: 2026-02-11 09:06 – Updated: 2026-02-11 15:44
VLAI
Title
LEAK OF SENSITIVE INFORMATION ON MICROCOM'S ZEUSWEB
Summary
Exposure of Sensitive System Information to an Unauthorized Actor vulnerability in Microcom ZeusWeb allows Web Application Fingerprinting of sensitive data. This issue affects ZeusWeb: 6.1.31.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0001/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2025-13651/ | technical-descriptionpatch |
| https://www.microcom360.com/servicio-zeus-web/ | product |
| https://zeus.microcom.es:4040/ | product |
Date Public
2026-02-11 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13651",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-11T15:41:17.555128Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T15:44:04.829Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ZeusWeb",
"vendor": "Microcom",
"versions": [
{
"status": "affected",
"version": "6.1.31"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microcom:zeusweb:6.1.31:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-02-11T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Exposure of Sensitive System Information to an Unauthorized Actor vulnerability in Microcom ZeusWeb allows Web Application Fingerprinting of sensitive data. This issue affects ZeusWeb: 6.1.31."
}
],
"value": "Exposure of Sensitive System Information to an Unauthorized Actor vulnerability in Microcom ZeusWeb allows Web Application Fingerprinting of sensitive data. This issue affects ZeusWeb: 6.1.31."
}
],
"impacts": [
{
"capecId": "CAPEC-224",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-224 Fingerprinting"
}
]
},
{
"capecId": "CAPEC-541",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-541 Application Fingerprinting"
}
]
},
{
"capecId": "CAPEC-170",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-170 Web Application Fingerprinting"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T09:06:09.297Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0001/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2025-13651/"
},
{
"tags": [
"product"
],
"url": "https://www.microcom360.com/servicio-zeus-web/"
},
{
"tags": [
"product"
],
"url": "https://zeus.microcom.es:4040/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implement the new version\u0026nbsp;6.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"value": "The provider has implement the new version\u00a06.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"source": {
"advisory": "HRTU#0001",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-11-06T11:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2025-11-11T11:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2025-11-12T15:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-02-11T09:10:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "LEAK OF SENSITIVE INFORMATION ON MICROCOM\u0027S ZEUSWEB",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2025-13651",
"datePublished": "2026-02-11T09:06:09.297Z",
"dateReserved": "2025-11-25T09:45:49.686Z",
"dateUpdated": "2026-02-11T15:44:04.829Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-13650 (GCVE-0-2025-13650)
Vulnerability from cvelistv5 – Published: 2026-02-11 09:05 – Updated: 2026-02-11 15:44
VLAI
Title
REFLECTED CROSS-SITE SCRIPTING (XSS) ON MICROCOM'S ZEUSWEB
Summary
An attacker with access to the web application ZeusWeb of the provider Microcom (in this case, registration is not necessary, but the action must be performed) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the ‘Surname’ parameter of the ‘Create Account’ operation at the URL: https://zeus.microcom.es:4040/index.html?zeus6=true . This issue affects ZeusWeb: 6.1.31.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0001/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2025-13650/ | technical-descriptionpatch |
| https://www.microcom360.com/servicio-zeus-web/ | product |
| https://zeus.microcom.es:4040/ | product |
Date Public
2026-02-11 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13650",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-11T15:36:57.738991Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T15:44:12.006Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ZeusWeb",
"vendor": "Microcom",
"versions": [
{
"status": "affected",
"version": "6.1.31"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microcom:zeusweb:6.1.31:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-02-11T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with access to the web application ZeusWeb of the provider Microcom (in this case, registration is not necessary, but the action must be performed) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the \u2018Surname\u2019 parameter of the \u2018Create Account\u2019 operation at the URL:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://zeus.microcom.es:4040/index.html?zeus6=true\"\u003ehttps://zeus.microcom.es:4040/index.html?zeus6=true\u003c/a\u003e.\u0026nbsp;This issue affects ZeusWeb: 6.1.31.\u003cbr\u003e"
}
],
"value": "An attacker with access to the web application ZeusWeb of the provider Microcom (in this case, registration is not necessary, but the action must be performed) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the \u2018Surname\u2019 parameter of the \u2018Create Account\u2019 operation at the URL:\u00a0 https://zeus.microcom.es:4040/index.html?zeus6=true .\u00a0This issue affects ZeusWeb: 6.1.31."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
},
{
"capecId": "CAPEC-591",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-591 Reflected XSS"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T09:05:55.452Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0001/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2025-13650/"
},
{
"tags": [
"product"
],
"url": "https://www.microcom360.com/servicio-zeus-web/"
},
{
"tags": [
"product"
],
"url": "https://zeus.microcom.es:4040/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implement the new version\u0026nbsp;6.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"value": "The provider has implement the new version\u00a06.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"source": {
"advisory": "HRTU#0001",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-11-06T11:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2025-11-11T11:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2025-11-12T15:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-02-11T09:10:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "REFLECTED CROSS-SITE SCRIPTING (XSS) ON MICROCOM\u0027S ZEUSWEB",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2025-13650",
"datePublished": "2026-02-11T09:05:55.452Z",
"dateReserved": "2025-11-25T09:45:48.429Z",
"dateUpdated": "2026-02-11T15:44:12.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-13649 (GCVE-0-2025-13649)
Vulnerability from cvelistv5 – Published: 2026-02-11 09:05 – Updated: 2026-02-11 15:44
VLAI
Title
REFLECTED CROSS-SITE SCRIPTING (XSS) ON MICROCOM'S ZEUSWEB
Summary
An attacker with access to the web application ZeusWeb of the provider Microcom
(in this case, registration is not necessary, but the action must be performed) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the ‘Email’ parameters within the ‘Recover password’ section at the URL: https://zeus.microcom.es:4040/index.html?zeus6=true . This issue affects ZeusWeb: 6.1.31.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0001/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2025-13649/ | technical-descriptionpatch |
| https://zeus.microcom.es:4040/ | product |
| https://www.microcom360.com/servicio-zeus-web/ | product |
Date Public
2026-02-11 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13649",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-11T15:36:59.095090Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T15:44:18.085Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ZeusWeb",
"vendor": "Microcom",
"versions": [
{
"status": "affected",
"version": "6.1.31"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microcom:zeusweb:6.1.31:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-02-11T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with access to the web application\u0026nbsp;ZeusWeb of the provider Microcom\n\n (in this case, registration is not necessary, but the action must be performed) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the \u2018Email\u2019 parameters within the \u2018Recover password\u2019 section at the URL: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://zeus.microcom.es:4040/index.html?zeus6=true\"\u003ehttps://zeus.microcom.es:4040/index.html?zeus6=true\u003c/a\u003e. This issue affects ZeusWeb: 6.1.31.\u003cbr\u003e"
}
],
"value": "An attacker with access to the web application\u00a0ZeusWeb of the provider Microcom\n\n (in this case, registration is not necessary, but the action must be performed) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the \u2018Email\u2019 parameters within the \u2018Recover password\u2019 section at the URL: https://zeus.microcom.es:4040/index.html?zeus6=true . This issue affects ZeusWeb: 6.1.31."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
},
{
"capecId": "CAPEC-591",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-591 Reflected XSS"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T09:05:28.204Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0001/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2025-13649/"
},
{
"tags": [
"product"
],
"url": "https://zeus.microcom.es:4040/"
},
{
"tags": [
"product"
],
"url": "https://www.microcom360.com/servicio-zeus-web/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implement the new version\u0026nbsp;6.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"value": "The provider has implement the new version\u00a06.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"source": {
"advisory": "HRTU#0001",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-11-06T11:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2025-11-11T11:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2025-11-12T15:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-02-11T09:10:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "REFLECTED CROSS-SITE SCRIPTING (XSS) ON MICROCOM\u0027S ZEUSWEB",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2025-13649",
"datePublished": "2026-02-11T09:05:28.204Z",
"dateReserved": "2025-11-25T09:45:47.332Z",
"dateUpdated": "2026-02-11T15:44:18.085Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-13648 (GCVE-0-2025-13648)
Vulnerability from cvelistv5 – Published: 2026-02-11 09:05 – Updated: 2026-02-11 15:44
VLAI
Title
STORED CROSS-SITE SCRIPTING (XSS) ON MICROCOM'S ZEUSWEB
Summary
An attacker with access to the web application ZeusWeb of the provider Microcom
(in this case, registration is required) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the ‘Name’ and “Surname” parameters within the ‘My Account’ section at the URL: https://zeus.microcom.es:4040/administracion-estaciones.html resulting in a stored XSS.
This issue affects ZeusWeb: 6.1.31.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.hackrtu.com/blog/CNA-HRTU-0001/ | technical-descriptionpatch |
| https://www.hackrtu.com/blog/CNA-CVE-2025-13648/ | technical-descriptionpatch |
| https://www.microcom360.com/servicio-zeus-web/ | product |
| https://zeus.microcom.es:4040/ | product |
Date Public
2026-02-11 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-13648",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-11T15:37:00.540527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T15:44:22.679Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ZeusWeb",
"vendor": "Microcom",
"versions": [
{
"status": "affected",
"version": "6.1.31"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microcom:zeusweb:6.1.31:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha Men\u00e9ndez"
},
{
"lang": "en",
"type": "finder",
"value": "V\u00edctor Bello Cuevas"
}
],
"datePublic": "2026-02-11T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker with access to the web application ZeusWeb of the provider Microcom\n\n (in this case, registration is required) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the \u2018Name\u2019 and \u201cSurname\u201d parameters within the \u2018My Account\u2019 section at the URL: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://zeus.microcom.es:4040/administracion-estaciones.html\"\u003ehttps://zeus.microcom.es:4040/administracion-estaciones.html\u003c/a\u003e\u0026nbsp;resulting in a stored XSS.\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eT\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ehis issue affects ZeusWeb: 6.1.31.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "An attacker with access to the web application ZeusWeb of the provider Microcom\n\n (in this case, registration is required) who has the vulnerable software could introduce arbitrary JavaScript by injecting an XSS payload into the \u2018Name\u2019 and \u201cSurname\u201d parameters within the \u2018My Account\u2019 section at the URL: https://zeus.microcom.es:4040/administracion-estaciones.html \u00a0resulting in a stored XSS.\nThis issue affects ZeusWeb: 6.1.31."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
},
{
"capecId": "CAPEC-592",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-592 Stored XSS"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-11T09:05:07.289Z",
"orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"shortName": "HackRTU"
},
"references": [
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-HRTU-0001/"
},
{
"tags": [
"technical-description",
"patch"
],
"url": "https://www.hackrtu.com/blog/CNA-CVE-2025-13648/"
},
{
"tags": [
"product"
],
"url": "https://www.microcom360.com/servicio-zeus-web/"
},
{
"tags": [
"product"
],
"url": "https://zeus.microcom.es:4040/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The provider has implement the new version\u0026nbsp;6.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"value": "The provider has implement the new version\u00a06.2.5 which solves the security problems detected in the previous version. The end user does not need to perform any update actions, as the software is cloud-based and managed by the provider, who has implemented the new version for all users."
}
],
"source": {
"advisory": "HRTU#0001",
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-11-06T11:00:00.000Z",
"value": "Vulnerability detection by the researchers"
},
{
"lang": "en",
"time": "2025-11-11T11:00:00.000Z",
"value": "Report from researchers to the CNA of HackRTU"
},
{
"lang": "en",
"time": "2025-11-12T15:00:00.000Z",
"value": "Report from HackRTU CNA to the provider"
},
{
"lang": "en",
"time": "2026-02-11T09:10:00.000Z",
"value": "Vulnerabilities published by HackRTU\u0027s CNA"
}
],
"title": "STORED CROSS-SITE SCRIPTING (XSS) ON MICROCOM\u0027S ZEUSWEB",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
"assignerShortName": "HackRTU",
"cveId": "CVE-2025-13648",
"datePublished": "2026-02-11T09:05:07.289Z",
"dateReserved": "2025-11-25T09:45:45.902Z",
"dateUpdated": "2026-02-11T15:44:22.679Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}