CVE-2026-27867 (GCVE-0-2026-27867)

Vulnerability from cvelistv5 – Published: 2026-09-25 10:32 – Updated: 2026-09-25 10:43
VLAI
Title
CROSS-SITE SCRIPTING (XSS) VIA THE CMDCOOKIE PARAMETER REGESTA SMART HD-PLC OF TELDAT
Summary
An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action is required) who has the vulnerable firmware version could inject a specific payload via the parameter "cmdcookie" withing the /upgrade/index.html resulting in to a Cross-Site Scripting (XSS). This issue affects Regesta Smart HD-PLC - TLDPH16D2:  11.02.06.00.02
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-25 10:42 UTC
CWE
  • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
Assigner
HackRTU CNA under the INCIBE root
CNA scorecard – unranked: 4 records in the last 180 days, 10 needed details
Impacted products
Vendor Product Version CPE status
Teldat Regesta Smart HD-PLC - TLDPH16D2 Affected: 11.02.06.00.02
Unaffected: 11.02.06.00.03
    cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2026-09-25 08:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-27867",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-25T10:42:56.136783Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-25T10:43:05.972Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Regesta Smart HD-PLC - TLDPH16D2",
          "vendor": "Teldat",
          "versions": [
            {
              "status": "affected",
              "version": "11.02.06.00.02"
            },
            {
              "status": "unaffected",
              "version": "11.02.06.00.03"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.03:*:*:*:*:*:*:*",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aar\u00f3n Flecha Men\u00e9ndez"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "V\u00edctor Bello Cuevas"
        }
      ],
      "datePublic": "2026-09-25T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action is required) who has the vulnerable firmware version could inject\na specific payload\u0026nbsp;via the parameter \"cmdcookie\" withing the\u003ci\u003e /upgrade/index.html\u003c/i\u003e resulting in to a Cross-Site Scripting (XSS).\u0026nbsp;This issue affects Regesta Smart HD-PLC - TLDPH16D2:\u0026nbsp;\n11.02.06.00.02"
            }
          ],
          "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action is required) who has the vulnerable firmware version could inject\na specific payload\u00a0via the parameter \"cmdcookie\" withing the /upgrade/index.html resulting in to a Cross-Site Scripting (XSS).\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2:\u00a0\n11.02.06.00.02"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        },
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-25T10:32:58.916Z",
        "orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
        "shortName": "HackRTU"
      },
      "references": [
        {
          "tags": [
            "patch",
            "technical-description"
          ],
          "url": "https://www.hackrtu.com/blog/CNA-HRTU-0004/"
        },
        {
          "tags": [
            "patch",
            "technical-description"
          ],
          "url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27867/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.teldat.com/es/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe\nprovider has implemented the new version \u003cb\u003e11.02.06.00.03 \u003c/b\u003ewhich solves the\nsecurity problems detected in the affected version. The end user has to\ndownload the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and\nimplement it in the device (\u003ca href=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e).\u003c/p\u003e"
            }
          ],
          "value": "The\nprovider has implemented the new version 11.02.06.00.03 which solves the\nsecurity problems detected in the affected version. The end user has to\ndownload the new version in the Teldat - Client Support Portal and\nimplement it in the device ( https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US )."
        }
      ],
      "source": {
        "advisory": "HRTU#0004",
        "discovery": "EXTERNAL"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2026-07-10T08:00:00.000Z",
          "value": "Vulnerability detection by the researchers"
        },
        {
          "lang": "en",
          "time": "2026-07-16T08:00:00.000Z",
          "value": "Report from researchers to the CNA of HackRTU"
        },
        {
          "lang": "en",
          "time": "2026-07-16T08:00:00.000Z",
          "value": "Report from HackRTU CNA to the provider"
        },
        {
          "lang": "en",
          "time": "2026-07-21T08:00:00.000Z",
          "value": "Second report from HackRTU CNA to the provider"
        },
        {
          "lang": "en",
          "time": "2026-09-25T08:00:00.000Z",
          "value": "Vulnerabilities published by HackRTU\u0027s CNA"
        }
      ],
      "title": "CROSS-SITE SCRIPTING (XSS) VIA THE CMDCOOKIE PARAMETER REGESTA SMART HD-PLC OF TELDAT",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
    "assignerShortName": "HackRTU",
    "cveId": "CVE-2026-27867",
    "datePublished": "2026-09-25T10:32:58.916Z",
    "dateReserved": "2026-02-24T08:59:28.139Z",
    "dateUpdated": "2026-09-25T10:43:05.972Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-27867",
      "date": "2026-11-16",
      "epss": "0.0037",
      "percentile": "0.31376"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "Regesta Smart HD-PLC - TLDPH16D2",
                "vendor": "Teldat",
                "versions": [
                  {
                    "status": "affected",
                    "version": "11.02.06.00.02"
                  },
                  {
                    "status": "unaffected",
                    "version": "11.02.06.00.03"
                  }
                ]
              }
            ],
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action is required) who has the vulnerable firmware version could inject\na specific payload\u00a0via the parameter \"cmdcookie\" withing the /upgrade/index.html resulting in to a Cross-Site Scripting (XSS).\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2:\u00a0\n11.02.06.00.02"
          }
        ],
        "id": "CVE-2026-27867",
        "lastModified": "2026-09-30T17:32:07.107",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-27867",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-25T10:42:56.136783Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-09-25T11:17:01.203",
        "references": [
          {
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
          },
          {
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
          },
          {
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27867/"
          },
          {
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "url": "https://www.hackrtu.com/blog/CNA-HRTU-0004/"
          },
          {
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "url": "https://www.teldat.com/es/"
          }
        ],
        "sourceIdentifier": "ffb98d57-deaa-4918-a669-5225ccc13e39",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27867",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-25T10:42:56.136783Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-25T10:43:01.692Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Regesta Smart HD-PLC - TLDPH16D2",
              "vendor": "Teldat",
              "versions": [
                {
                  "status": "affected",
                  "version": "11.02.06.00.02"
                },
                {
                  "status": "unaffected",
                  "version": "11.02.06.00.03"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*",
                      "vulnerable": true
                    },
                    {
                      "criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.03:*:*:*:*:*:*:*",
                      "vulnerable": false
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Aar\u00f3n Flecha Men\u00e9ndez"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "V\u00edctor Bello Cuevas"
            }
          ],
          "datePublic": "2026-09-25T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action is required) who has the vulnerable firmware version could inject\na specific payload\u0026nbsp;via the parameter \"cmdcookie\" withing the\u003ci\u003e /upgrade/index.html\u003c/i\u003e resulting in to a Cross-Site Scripting (XSS).\u0026nbsp;This issue affects Regesta Smart HD-PLC - TLDPH16D2:\u0026nbsp;\n11.02.06.00.02"
                }
              ],
              "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, registration action is required) who has the vulnerable firmware version could inject\na specific payload\u00a0via the parameter \"cmdcookie\" withing the /upgrade/index.html resulting in to a Cross-Site Scripting (XSS).\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2:\u00a0\n11.02.06.00.02"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            },
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-25T10:32:58.916Z",
            "orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
            "shortName": "HackRTU"
          },
          "references": [
            {
              "tags": [
                "patch",
                "technical-description"
              ],
              "url": "https://www.hackrtu.com/blog/CNA-HRTU-0004/"
            },
            {
              "tags": [
                "patch",
                "technical-description"
              ],
              "url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27867/"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.teldat.com/es/"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe\nprovider has implemented the new version \u003cb\u003e11.02.06.00.03 \u003c/b\u003ewhich solves the\nsecurity problems detected in the affected version. The end user has to\ndownload the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and\nimplement it in the device (\u003ca href=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e).\u003c/p\u003e"
                }
              ],
              "value": "The\nprovider has implemented the new version 11.02.06.00.03 which solves the\nsecurity problems detected in the affected version. The end user has to\ndownload the new version in the Teldat - Client Support Portal and\nimplement it in the device ( https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US )."
            }
          ],
          "source": {
            "advisory": "HRTU#0004",
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2026-07-10T08:00:00.000Z",
              "value": "Vulnerability detection by the researchers"
            },
            {
              "lang": "en",
              "time": "2026-07-16T08:00:00.000Z",
              "value": "Report from researchers to the CNA of HackRTU"
            },
            {
              "lang": "en",
              "time": "2026-07-16T08:00:00.000Z",
              "value": "Report from HackRTU CNA to the provider"
            },
            {
              "lang": "en",
              "time": "2026-07-21T08:00:00.000Z",
              "value": "Second report from HackRTU CNA to the provider"
            },
            {
              "lang": "en",
              "time": "2026-09-25T08:00:00.000Z",
              "value": "Vulnerabilities published by HackRTU\u0027s CNA"
            }
          ],
          "title": "CROSS-SITE SCRIPTING (XSS) VIA THE CMDCOOKIE PARAMETER REGESTA SMART HD-PLC OF TELDAT",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
        "assignerShortName": "HackRTU",
        "cveId": "CVE-2026-27867",
        "datePublished": "2026-09-25T10:32:58.916Z",
        "dateReserved": "2026-02-24T08:59:28.139Z",
        "dateUpdated": "2026-09-25T10:43:05.972Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Solutions

CNA · HackRTU
The provider has implemented the new version 11.02.06.00.03 which solves the security problems detected in the affected version. The end user has to download the new version in the Teldat - Client Support Portal and implement it in the device ( https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support&none=true&language=en-US ).

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.