CWE-125
Weakness AllowedOut-of-bounds Read
Abstraction: Base · Status: Draft
The product reads data past the end, or before the beginning, of the intended buffer.
Dimensions
- Behavior-Type: Read
- Resource-Type: Memory Buffer
- Resource-Property: Out-of-bounds
Mapping guidance
This CWE entry is at the Base level of abstraction, which is a preferred level of abstraction for mapping to the root causes of vulnerabilities.
Carefully read both the name and description to ensure that this mapping is an appropriate fit. Do not try to 'force' a mapping to a lower-level Base/Variant simply to comply with this preferred level of abstraction.
Relationships and members
Modes of introduction
Detection methods
Fuzzing
Fuzz testing (fuzzing) is a powerful technique for generating large numbers of diverse inputs - either randomly or algorithmically - and dynamically invoking the code with those inputs. Even with random inputs, it is often capable of generating unexpected results such as crashes, memory corruption, or resource consumption. Fuzzing effectively produces repeatable test cases that clearly indicate bugs, which helps developers to diagnose the issues.
Effectiveness: High
Automated Static Analysis
Automated static analysis, commonly referred to as Static Application Security Testing (SAST), can find some instances of this weakness by analyzing source code (or binary/compiled code) without having to execute it. Typically, this is done by building a model of data flow and control flow, then searching for potentially-vulnerable patterns that connect "sources" (origins of input) with "sinks" (destinations where the data interacts with external components, a lower layer such as the OS, etc.)
Effectiveness: High
Automated Dynamic Analysis
Use tools that are integrated during compilation to insert runtime error-checking mechanisms related to memory safety errors, such as AddressSanitizer (ASan) for C/C++ [REF-1518].
Effectiveness: Moderate
Crafted inputs are necessary to reach the code containing the error, such as generated by fuzzers. Also, these tools may reduce performance, and they only report the error condition - not the original mistake that led to the error.
Content history
Provided diagram to improve CWE usability
updated Applicable_Platforms, Relationships, Taxonomy_Mappings, Weakness_Ordinalities
updated Description
updated Relationships
updated Common_Consequences
updated Demonstrative_Examples, References, Relationships
updated Related_Attack_Patterns
updated Relationships, Taxonomy_Mappings
updated Relationships
updated Causal_Nature, Observed_Examples, Taxonomy_Mappings
updated Description
updated Relationships
updated Description, Related_Attack_Patterns
updated Common_Consequences, Observed_Examples, Potential_Mitigations, References, Relationships
updated Potential_Mitigations, Relationships, Taxonomy_Mappings
updated Observed_Examples, Potential_Mitigations
updated Observed_Examples, Potential_Mitigations, Relationships
updated Related_Attack_Patterns, Relationships
updated Observed_Examples, Relationships
updated Research_Gaps
updated Observed_Examples, Relationships
updated Applicable_Platforms, Relationships, Taxonomy_Mappings
updated Description
updated Detection_Factors, References, Relationships
updated Mapping_Notes, Relationships
updated Observed_Examples
updated Alternate_Terms, Common_Consequences, Description, Diagram, Weakness_Ordinalities
updated Observed_Examples, Relationships
updated Affected_Resources, Demonstrative_Examples, Functional_Areas
updated Applicable_Platforms, Detection_Factors, References, Relationships
updated Applicable_Platforms, Demonstrative_Examples, Dimensions, Observed_Examples, References, Relationships, Taxonomy_Mappings
14392 vulnerabilities reference this CWE, most recent first.
CVE-2020-1821 (GCVE-0-2020-1821)
Vulnerability from cvelistv5 – Published: 2024-12-28 06:16 – Updated: 2024-12-30 16:13- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |
|---|---|---|---|
| Huawei | IPS Module |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NGFW Module |
Affected:
V500R002C00
Affected: V500R002C20 Affected: V500R005C00 |
|
| Huawei | NIP6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6600 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6800 |
Affected:
V500R001C60
Affected: V500R005C00 |
|
| Huawei | Secospace USG6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6500 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6600 |
Affected:
V500R001C30
Affected: V500R005C00 |
|
| Huawei | USG6000V |
Affected:
V500R003C00
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-1821",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-30T16:12:49.264838Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-30T16:13:03.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IPS Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NGFW Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R002C00"
},
{
"status": "affected",
"version": "V500R002C20"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6800",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6500",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "USG6000V",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R003C00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\u003c/p\u003e\u003cp\u003eThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824.\u003c/p\u003e"
}
],
"value": "There are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\n\nThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-28T06:16:58.770Z",
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei"
},
"references": [
{
"url": "https://www.huawei.com/en/psirt/security-advisories/2020/huawei-sa-20191218-01-cops-en"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"assignerShortName": "huawei",
"cveId": "CVE-2020-1821",
"datePublished": "2024-12-28T06:16:58.770Z",
"dateReserved": "2019-11-29T00:00:00.000Z",
"dateUpdated": "2024-12-30T16:13:03.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1820 (GCVE-0-2020-1820)
Vulnerability from cvelistv5 – Published: 2024-12-28 06:11 – Updated: 2024-12-31 17:17- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |
|---|---|---|---|
| Huawei | IPS Module |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NGFW Module |
Affected:
V500R002C00
Affected: V500R002C20 Affected: V500R005C00 |
|
| Huawei | NIP6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6600 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6800 |
Affected:
V500R001C60
Affected: V500R005C00 |
|
| Huawei | Secospace USG6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6500 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6600 |
Affected:
V500R001C30
Affected: V500R005C00 |
|
| Huawei | USG6000V |
Affected:
V500R003C00
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-1820",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-31T17:16:57.375041Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-31T17:17:05.860Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IPS Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NGFW Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R002C00"
},
{
"status": "affected",
"version": "V500R002C20"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6800",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6500",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "USG6000V",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R003C00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\u003c/p\u003e\u003cp\u003eThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824.\u003c/p\u003e"
}
],
"value": "There are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\n\nThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-28T06:11:17.446Z",
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei"
},
"references": [
{
"url": "https://www.huawei.com/en/psirt/security-advisories/2020/huawei-sa-20191218-01-cops-en"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"assignerShortName": "huawei",
"cveId": "CVE-2020-1820",
"datePublished": "2024-12-28T06:11:17.446Z",
"dateReserved": "2019-11-29T00:00:00.000Z",
"dateUpdated": "2024-12-31T17:17:05.860Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1819 (GCVE-0-2020-1819)
Vulnerability from cvelistv5 – Published: 2024-12-27 10:05 – Updated: 2024-12-27 14:56- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |
|---|---|---|---|
| Huawei | IPS Module |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NGFW Module |
Affected:
V500R002C00
Affected: V500R002C20 Affected: V500R005C00 |
|
| Huawei | NIP6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6600 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6800 |
Affected:
V500R001C60
Affected: V500R005C00 |
|
| Huawei | Secospace USG6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6500 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6600 |
Affected:
V500R001C30
Affected: V500R005C00 |
|
| Huawei | USG6000V |
Affected:
V500R003C00
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-1819",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-27T14:56:22.966063Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-27T14:56:31.845Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IPS Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NGFW Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R002C00"
},
{
"status": "affected",
"version": "V500R002C20"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6800",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6500",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "USG6000V",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R003C00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\u003c/p\u003e\u003cp\u003eThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824.\u003c/p\u003e"
}
],
"value": "There are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\n\nThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-27T10:05:47.224Z",
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei"
},
"references": [
{
"url": "https://www.huawei.com/en/psirt/security-advisories/2020/huawei-sa-20191218-01-cops-en"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"assignerShortName": "huawei",
"cveId": "CVE-2020-1819",
"datePublished": "2024-12-27T10:05:47.224Z",
"dateReserved": "2019-11-29T00:00:00.000Z",
"dateUpdated": "2024-12-27T14:56:31.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1818 (GCVE-0-2020-1818)
Vulnerability from cvelistv5 – Published: 2024-12-27 10:02 – Updated: 2024-12-27 14:57- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |
|---|---|---|---|
| Huawei | IPS Module |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NGFW Module |
Affected:
V500R002C00
Affected: V500R002C20 Affected: V500R005C00 |
|
| Huawei | NIP6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6600 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | NIP6800 |
Affected:
V500R001C60
Affected: V500R005C00 |
|
| Huawei | Secospace USG6300 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6500 |
Affected:
V500R001C30
Affected: V500R001C60 Affected: V500R005C00 |
|
| Huawei | Secospace USG6600 |
Affected:
V500R001C30
Affected: V500R005C00 |
|
| Huawei | USG6000V |
Affected:
V500R003C00
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-1818",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-27T14:56:47.972518Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-27T14:57:27.653Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IPS Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NGFW Module",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R002C00"
},
{
"status": "affected",
"version": "V500R002C20"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NIP6800",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6300",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6500",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R001C60"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secospace USG6600",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R001C30"
},
{
"status": "affected",
"version": "V500R005C00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "USG6000V",
"vendor": "Huawei",
"versions": [
{
"status": "affected",
"version": "V500R003C00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\u003c/p\u003e\u003cp\u003eThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824.\u003c/p\u003e"
}
],
"value": "There are multiple out of bounds (OOB) read vulnerabilities in the implementation of the Common Open Policy Service (COPS) protocol of some Huawei products. The specific decoding function may occur out-of-bounds read when processes an incoming data packet. Successful exploit of these vulnerabilities may disrupt service on the affected device. (Vulnerability ID: HWPSIRT-2018-12275,HWPSIRT-2018-12276,HWPSIRT-2018-12277,HWPSIRT-2018-12278,HWPSIRT-2018-12279,HWPSIRT-2018-12280 and HWPSIRT-2018-12289)\n\nThe seven vulnerabilities have been assigned seven Common Vulnerabilities and Exposures (CVE) IDs: CVE-2020-1818, CVE-2020-1819, CVE-2020-1820, CVE-2020-1821, CVE-2020-1822, CVE-2020-1823 and CVE-2020-1824."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-27T10:02:45.710Z",
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei"
},
"references": [
{
"url": "https://www.huawei.com/en/psirt/security-advisories/2020/huawei-sa-20191218-01-cops-en"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"assignerShortName": "huawei",
"cveId": "CVE-2020-1818",
"datePublished": "2024-12-27T10:02:45.710Z",
"dateReserved": "2019-11-29T00:00:00.000Z",
"dateUpdated": "2024-12-27T14:57:27.653Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1763 (GCVE-0-2020-1763)
Vulnerability from cvelistv5 – Published: 2020-05-12 13:41 – Updated: 2024-08-04 06:46| URL | Tags |
|---|---|
| https://libreswan.org/security/CVE-2020-1763/CVE-… | x_refsource_CONFIRM |
| https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2… | x_refsource_CONFIRM |
| https://bugzilla.redhat.com/show_bug.cgi?id=1813329 | x_refsource_MISC |
| https://github.com/libreswan/libreswan/commit/471… | x_refsource_CONFIRM |
| https://www.debian.org/security/2020/dsa-4684 | vendor-advisoryx_refsource_DEBIAN |
| https://security.gentoo.org/glsa/202007-21 | vendor-advisoryx_refsource_GENTOO |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| the libreswan Project | libreswan |
Affected:
from versions 3.27 till 3.31
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:46:30.902Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://libreswan.org/security/CVE-2020-1763/CVE-2020-1763.txt"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1763"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1813329"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/libreswan/libreswan/commit/471a3e41a449d7c753bc4edbba4239501bb62ba8"
},
{
"name": "DSA-4684",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2020/dsa-4684"
},
{
"name": "GLSA-202007-21",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202007-21"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-379803.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "libreswan",
"vendor": "the libreswan Project",
"versions": [
{
"status": "affected",
"version": "from versions 3.27 till 3.31"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An out-of-bounds buffer read flaw was found in the pluto daemon of libreswan from versions 3.27 till 3.31 where, an unauthenticated attacker could use this flaw to crash libreswan by sending specially-crafted IKEv1 Informational Exchange packets. The daemon respawns after the crash."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-12T05:48:52.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://libreswan.org/security/CVE-2020-1763/CVE-2020-1763.txt"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1763"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1813329"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/libreswan/libreswan/commit/471a3e41a449d7c753bc4edbba4239501bb62ba8"
},
{
"name": "DSA-4684",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2020/dsa-4684"
},
{
"name": "GLSA-202007-21",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO"
],
"url": "https://security.gentoo.org/glsa/202007-21"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-379803.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert@redhat.com",
"ID": "CVE-2020-1763",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "libreswan",
"version": {
"version_data": [
{
"version_value": "from versions 3.27 till 3.31"
}
]
}
}
]
},
"vendor_name": "the libreswan Project"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An out-of-bounds buffer read flaw was found in the pluto daemon of libreswan from versions 3.27 till 3.31 where, an unauthenticated attacker could use this flaw to crash libreswan by sending specially-crafted IKEv1 Informational Exchange packets. The daemon respawns after the crash."
}
]
},
"impact": {
"cvss": [
[
{
"vectorString": "7.5/CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
]
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://libreswan.org/security/CVE-2020-1763/CVE-2020-1763.txt",
"refsource": "CONFIRM",
"url": "https://libreswan.org/security/CVE-2020-1763/CVE-2020-1763.txt"
},
{
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1763",
"refsource": "CONFIRM",
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1763"
},
{
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=1813329",
"refsource": "MISC",
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1813329"
},
{
"name": "https://github.com/libreswan/libreswan/commit/471a3e41a449d7c753bc4edbba4239501bb62ba8",
"refsource": "CONFIRM",
"url": "https://github.com/libreswan/libreswan/commit/471a3e41a449d7c753bc4edbba4239501bb62ba8"
},
{
"name": "DSA-4684",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2020/dsa-4684"
},
{
"name": "GLSA-202007-21",
"refsource": "GENTOO",
"url": "https://security.gentoo.org/glsa/202007-21"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-379803.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-379803.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2020-1763",
"datePublished": "2020-05-12T13:41:20.000Z",
"dateReserved": "2019-11-27T00:00:00.000Z",
"dateUpdated": "2024-08-04T06:46:30.902Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1671 (GCVE-0-2020-1671)
Vulnerability from cvelistv5 – Published: 2020-10-16 20:31 – Updated: 2024-09-17 01:00| URL | Tags |
|---|---|
| https://kb.juniper.net/JSA11068 | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Juniper Networks | Junos OS |
Unaffected:
unspecified , < 17.4R1
(custom)
Affected: 17.4 , < 17.4R2-S12, 17.4R3-S3 (custom) Affected: 18.1 , < 18.1R3-S11 (custom) Affected: 18.2 , < 18.2R3-S6 (custom) Affected: 18.2X75 , < 18.2X75-D65 (custom) Affected: 18.3 , < 18.3R2-S4, 18.3R3-S3 (custom) Affected: 18.4 , < 18.4R2-S5, 18.4R3-S4 (custom) Affected: 19.1 , < 19.1R3-S2 (custom) Affected: 19.2 , < 19.2R1-S5, 19.2R3 (custom) Affected: 19.3 , < 19.3R2-S4, 19.3R3 (custom) Affected: 19.4 , < 19.4R1-S3, 19.4R2-S2, 19.4R3 (custom) Affected: 20.1 , < 20.1R1-S3, 20.1R2 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:46:29.907Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.juniper.net/JSA11068"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Junos OS",
"vendor": "Juniper Networks",
"versions": [
{
"lessThan": "17.4R1",
"status": "unaffected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "17.4R2-S12, 17.4R3-S3",
"status": "affected",
"version": "17.4",
"versionType": "custom"
},
{
"lessThan": "18.1R3-S11",
"status": "affected",
"version": "18.1",
"versionType": "custom"
},
{
"lessThan": "18.2R3-S6",
"status": "affected",
"version": "18.2",
"versionType": "custom"
},
{
"lessThan": "18.2X75-D65",
"status": "affected",
"version": "18.2X75",
"versionType": "custom"
},
{
"lessThan": "18.3R2-S4, 18.3R3-S3",
"status": "affected",
"version": "18.3",
"versionType": "custom"
},
{
"lessThan": "18.4R2-S5, 18.4R3-S4",
"status": "affected",
"version": "18.4",
"versionType": "custom"
},
{
"lessThan": "19.1R3-S2",
"status": "affected",
"version": "19.1",
"versionType": "custom"
},
{
"changes": [
{
"at": "19.2R2",
"status": "affected"
}
],
"lessThan": "19.2R1-S5, 19.2R3",
"status": "affected",
"version": "19.2",
"versionType": "custom"
},
{
"lessThan": "19.3R2-S4, 19.3R3",
"status": "affected",
"version": "19.3",
"versionType": "custom"
},
{
"lessThan": "19.4R1-S3, 19.4R2-S2, 19.4R3",
"status": "affected",
"version": "19.4",
"versionType": "custom"
},
{
"lessThan": "20.1R1-S3, 20.1R2",
"status": "affected",
"version": "20.1",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"value": "The example of DHCPv6 local server configuration stanza affected by this issue is:\n [system services dhcp-local-server dhcpv6]\n\nThe example of configuration stanza for DHCPv6 Relay Agent affected by this issue is: \n [forwarding-options dhcp-relay dhcpv6]"
}
],
"datePublic": "2020-10-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "On Juniper Networks Junos OS platforms configured as DHCPv6 local server or DHCPv6 Relay Agent, Juniper Networks Dynamic Host Configuration Protocol Daemon (JDHCPD) process might crash with a core dump if a malformed DHCPv6 packet is received, resulting with the restart of the daemon. This issue only affects DHCPv6, it does not affect DHCPv4. This issue affects: Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.2 version 19.2R2 and later versions; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R1-S3, 20.1R2; This issue does not affect Juniper Networks Junos OS prior to 17.4R1."
}
],
"exploits": [
{
"lang": "en",
"value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-16T20:31:30.000Z",
"orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
"shortName": "juniper"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.juniper.net/JSA11068"
}
],
"solutions": [
{
"lang": "en",
"value": "The following software releases have been updated to resolve this specific issue: Junos OS 17.4R2-S12, 17.4R3-S3, 18.1R3-S11, 18.2R3-S6, 18.2X75-D65, 18.3R2-S4, 18.3R3-S3, 18.4R2-S5, 18.4R3-S4, 19.1R3-S2, 19.2R1-S5, 19.2R3, 19.3R2-S4, 19.3R3, 19.4R1-S3, 19.4R2-S2, 19.4R3, 20.1R1-S3, 20.1R2, 20.2R1 and all subsequent releases."
}
],
"source": {
"advisory": "JSA11068",
"defect": [
"1511782"
],
"discovery": "USER"
},
"title": "Junos OS: Receipt of malformed DHCPv6 packets causes jdhcpd to crash.",
"workarounds": [
{
"lang": "en",
"value": "There are no viable workarounds for this issue."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "sirt@juniper.net",
"DATE_PUBLIC": "2020-10-14T07:00:00.000Z",
"ID": "CVE-2020-1671",
"STATE": "PUBLIC",
"TITLE": "Junos OS: Receipt of malformed DHCPv6 packets causes jdhcpd to crash."
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Junos OS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "17.4",
"version_value": "17.4R2-S12, 17.4R3-S3"
},
{
"version_affected": "\u003c",
"version_name": "18.1",
"version_value": "18.1R3-S11"
},
{
"version_affected": "\u003c",
"version_name": "18.2",
"version_value": "18.2R3-S6"
},
{
"version_affected": "\u003c",
"version_name": "18.2X75",
"version_value": "18.2X75-D65"
},
{
"version_affected": "\u003c",
"version_name": "18.3",
"version_value": "18.3R2-S4, 18.3R3-S3"
},
{
"version_affected": "\u003c",
"version_name": "18.4",
"version_value": "18.4R2-S5, 18.4R3-S4"
},
{
"version_affected": "\u003c",
"version_name": "19.1",
"version_value": "19.1R3-S2"
},
{
"version_affected": "\u003c",
"version_name": "19.2",
"version_value": "19.2R1-S5, 19.2R3"
},
{
"version_affected": "\u003e=",
"version_name": "19.2",
"version_value": "19.2R2"
},
{
"version_affected": "\u003c",
"version_name": "19.3",
"version_value": "19.3R2-S4, 19.3R3"
},
{
"version_affected": "\u003c",
"version_name": "19.4",
"version_value": "19.4R1-S3, 19.4R2-S2, 19.4R3"
},
{
"version_affected": "\u003c",
"version_name": "20.1",
"version_value": "20.1R1-S3, 20.1R2"
},
{
"version_affected": "!\u003c",
"version_value": "17.4R1"
}
]
}
}
]
},
"vendor_name": "Juniper Networks"
}
]
}
},
"configuration": [
{
"lang": "en",
"value": "The example of DHCPv6 local server configuration stanza affected by this issue is:\n [system services dhcp-local-server dhcpv6]\n\nThe example of configuration stanza for DHCPv6 Relay Agent affected by this issue is: \n [forwarding-options dhcp-relay dhcpv6]"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Juniper Networks Junos OS platforms configured as DHCPv6 local server or DHCPv6 Relay Agent, Juniper Networks Dynamic Host Configuration Protocol Daemon (JDHCPD) process might crash with a core dump if a malformed DHCPv6 packet is received, resulting with the restart of the daemon. This issue only affects DHCPv6, it does not affect DHCPv4. This issue affects: Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.2X75 versions prior to 18.2X75-D65; 18.3 versions prior to 18.3R2-S4, 18.3R3-S3; 18.4 versions prior to 18.4R2-S5, 18.4R3-S4; 19.1 versions prior to 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R3; 19.2 version 19.2R2 and later versions; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R1-S3, 20.1R2; This issue does not affect Juniper Networks Junos OS prior to 17.4R1."
}
]
},
"exploit": [
{
"lang": "en",
"value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
}
],
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.juniper.net/JSA11068",
"refsource": "CONFIRM",
"url": "https://kb.juniper.net/JSA11068"
}
]
},
"solution": [
{
"lang": "en",
"value": "The following software releases have been updated to resolve this specific issue: Junos OS 17.4R2-S12, 17.4R3-S3, 18.1R3-S11, 18.2R3-S6, 18.2X75-D65, 18.3R2-S4, 18.3R3-S3, 18.4R2-S5, 18.4R3-S4, 19.1R3-S2, 19.2R1-S5, 19.2R3, 19.3R2-S4, 19.3R3, 19.4R1-S3, 19.4R2-S2, 19.4R3, 20.1R1-S3, 20.1R2, 20.2R1 and all subsequent releases."
}
],
"source": {
"advisory": "JSA11068",
"defect": [
"1511782"
],
"discovery": "USER"
},
"work_around": [
{
"lang": "en",
"value": "There are no viable workarounds for this issue."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
"assignerShortName": "juniper",
"cveId": "CVE-2020-1671",
"datePublished": "2020-10-16T20:31:30.432Z",
"dateReserved": "2019-11-04T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:00:53.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18307 (GCVE-0-2019-18307)
Vulnerability from cvelistv5 – Published: 2019-12-12 19:08 – Updated: 2024-08-05 01:47- CWE-125 - Out-of-bounds Read
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://packetstormsecurity.com/files/155665/Sieme… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SPPA-T3000 MS3000 Migration Server |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:47:14.140Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SPPA-T3000 MS3000 Migration Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18306. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T17:51:51.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-18307",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SPPA-T3000 MS3000 Migration Server",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18306. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"name": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-18307",
"datePublished": "2019-12-12T19:08:48.000Z",
"dateReserved": "2019-10-23T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:47:14.140Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18306 (GCVE-0-2019-18306)
Vulnerability from cvelistv5 – Published: 2019-12-12 19:08 – Updated: 2024-08-05 01:47- CWE-125 - Out-of-bounds Read
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://packetstormsecurity.com/files/155665/Sieme… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SPPA-T3000 MS3000 Migration Server |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:47:14.163Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SPPA-T3000 MS3000 Migration Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T17:51:49.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-18306",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SPPA-T3000 MS3000 Migration Server",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"name": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-18306",
"datePublished": "2019-12-12T19:08:47.000Z",
"dateReserved": "2019-10-23T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:47:14.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-17138 (GCVE-0-2019-17138)
Vulnerability from cvelistv5 – Published: 2019-10-25 18:14 – Updated: 2024-08-05 01:33- CWE-125 - Out-of-bounds Read
| URL | Tags |
|---|---|
| https://www.foxitsoftware.com/support/security-bu… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Foxit | Studio Photo |
Affected:
3.6.6.909
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:33:17.294Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-908/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Studio Photo",
"vendor": "Foxit",
"versions": [
{
"status": "affected",
"version": "3.6.6.909"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Steven Seeley (mr_me) of Source Incite"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit Studio Photo 3.6.6.909. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion from JPEG to EPS. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-8809."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-25T18:14:18.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-908/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2019-17138",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Studio Photo",
"version": {
"version_data": [
{
"version_value": "3.6.6.909"
}
]
}
}
]
},
"vendor_name": "Foxit"
}
]
}
},
"credit": "Steven Seeley (mr_me) of Source Incite",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit Studio Photo 3.6.6.909. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion from JPEG to EPS. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-8809."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.foxitsoftware.com/support/security-bulletins.php",
"refsource": "MISC",
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-908/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-908/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2019-17138",
"datePublished": "2019-10-25T18:14:18.000Z",
"dateReserved": "2019-10-04T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:33:17.294Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-17136 (GCVE-0-2019-17136)
Vulnerability from cvelistv5 – Published: 2020-02-07 23:35 – Updated: 2024-08-05 01:33- CWE-125 - Out-of-bounds Read
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Foxit | PhantomPDF |
Affected:
9.5.0.20723
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:33:17.282Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-861/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PhantomPDF",
"vendor": "Foxit",
"versions": [
{
"status": "affected",
"version": "9.5.0.20723"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 9.5.0.20723. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of DXF files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-8776."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-07T23:35:17.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-861/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2019-17136",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PhantomPDF",
"version": {
"version_data": [
{
"version_value": "9.5.0.20723"
}
]
}
}
]
},
"vendor_name": "Foxit"
}
]
}
},
"credit": "Mat Powell of Trend Micro Zero Day Initiative",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 9.5.0.20723. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of DXF files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-8776."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-861/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-861/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2019-17136",
"datePublished": "2020-02-07T23:35:17.000Z",
"dateReserved": "2019-10-04T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:33:17.282Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-5
Strategy: Input Validation
- Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
- When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
- Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
- To reduce the likelihood of introducing an out-of-bounds read, ensure that you validate and ensure correct calculations for any length argument, buffer size calculation, or offset. Be especially careful of relying on a sentinel (i.e. special character such as NUL) in untrusted inputs.
Mitigation
Strategy: Language Selection
Use a language that provides appropriate memory abstractions.
CAPEC-540: Overread Buffers
An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.