Vulnerability from variot - Updated: 2025-11-19 23:07A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used. The Tenda AC23 is a dual-band wireless router for home use, designed for large homes with excellent coverage and high-speed transmission. It supports 802.11ac Wave2 technology and boasts a maximum concurrent dual-band speed of 2033Mbps. This vulnerability stems from the fact that the parameter Time in the file /goform/saveParentControlInfo fails to properly validate the length of the input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202511-0090",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac23",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "16.03.07.52"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"cve": "CVE-2025-12596",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-12596",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-27900",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-12596",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-12596",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-12596",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-12596",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2025-27900",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"db": "NVD",
"id": "CVE-2025-12596"
},
{
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used. The Tenda AC23 is a dual-band wireless router for home use, designed for large homes with excellent coverage and high-speed transmission. It supports 802.11ac Wave2 technology and boasts a maximum concurrent dual-band speed of 2033Mbps. This vulnerability stems from the fact that the parameter Time in the file /goform/saveParentControlInfo fails to properly validate the length of the input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-12596"
},
{
"db": "CNVD",
"id": "CNVD-2025-27900"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-12596",
"trust": 1.6
},
{
"db": "VULDB",
"id": "330891",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2025-27900",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"id": "VAR-202511-0090",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
}
],
"trust": 1.05
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
}
]
},
"last_update_date": "2025-11-19T23:07:01.491000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-120",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/lx-lx88/cve/issues/9"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.330891"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?submit.677585"
},
{
"trust": 1.0,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?id.330891"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-11-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"date": "2025-11-02T11:15:35.373000",
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-11-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-27900"
},
{
"date": "2025-11-05T15:55:16.150000",
"db": "NVD",
"id": "CVE-2025-12596"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC23 saveParentControlInfo file buffer overflow vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-27900"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.