Search criteria

762 vulnerabilities by Tenda

CVE-2026-11557 (GCVE-0-2026-11557)

Vulnerability from cvelistv5 – Published: 2026-06-08 18:15 – Updated: 2026-06-08 19:52
VLAI
Title
Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow
Summary
A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda F451 Affected: 1.0.0.7
Affected: 1.0.0.9
    cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hacker128 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11557",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T19:52:15.831128Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T19:52:29.251Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "F451",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.7"
            },
            {
              "status": "affected",
              "version": "1.0.0.9"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T18:15:10.637Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369167 | Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369167"
        },
        {
          "name": "VDB-369167 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369167/cti"
        },
        {
          "name": "CVE-2026-11557 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11557"
        },
        {
          "name": "Submit #836477 | Tenda Tenda F451 Wireless Router V1.0.0.7, V1.0.0.9 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836477"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/fromNatlimit/fromNatlimit.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-08T08:00:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F451 Web Management Natlimit fromNatlimit stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11557",
    "datePublished": "2026-06-08T18:15:10.637Z",
    "dateReserved": "2026-06-08T05:55:39.465Z",
    "dateUpdated": "2026-06-08T19:52:29.251Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11556 (GCVE-0-2026-11556)

Vulnerability from cvelistv5 – Published: 2026-06-08 18:00 – Updated: 2026-06-09 14:35
VLAI
Title
Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection
Summary
A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda F451 Affected: 1.0.0.7
Affected: 1.0.0.9
    cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hacker128 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11556",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-09T14:33:10.240378Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-09T14:35:15.927Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f451_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "F451",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.7"
            },
            {
              "status": "affected",
              "version": "1.0.0.9"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T18:00:15.317Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369166 | Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369166"
        },
        {
          "name": "VDB-369166 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369166/cti"
        },
        {
          "name": "CVE-2026-11556 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11556"
        },
        {
          "name": "Submit #836476 | Tenda Tenda F451 Wireless Router V1.0.0.7, V1.0.0.9 OS Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836476"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWriteFacMac2/formWriteFacMac.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-08T08:00:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F451 Web Management WriteFacMac formWriteFacMac os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11556",
    "datePublished": "2026-06-08T18:00:15.317Z",
    "dateReserved": "2026-06-08T05:55:33.297Z",
    "dateUpdated": "2026-06-09T14:35:15.927Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11553 (GCVE-0-2026-11553)

Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
VLAI
Title
Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
zhihua xie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11553",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T18:49:04.954919Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T18:49:14.135Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zhihua xie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T17:15:11.855Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369163"
        },
        {
          "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369163/cti"
        },
        {
          "name": "CVE-2026-11553 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11553"
        },
        {
          "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836778"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-08T07:48:34.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11553",
    "datePublished": "2026-06-08T17:15:11.855Z",
    "dateReserved": "2026-06-08T05:43:31.214Z",
    "dateUpdated": "2026-06-08T18:49:14.135Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11528 (GCVE-0-2026-11528)

Vulnerability from cvelistv5 – Published: 2026-06-08 15:15 – Updated: 2026-06-09 14:35
VLAI
Title
Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC18 Affected: 15.03.05.05
    cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hacker128 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11528",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-09T14:27:07.795609Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-09T14:35:55.593Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.05"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T15:15:12.614Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369145 | Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369145"
        },
        {
          "name": "VDB-369145 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369145/cti"
        },
        {
          "name": "CVE-2026-11528 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11528"
        },
        {
          "name": "Submit #836474 | Tenda Tenda AC18 Wireless Router  V15.03.05.05 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836474"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/getRebootStatus/getRebootStatus.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T21:47:18.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11528",
    "datePublished": "2026-06-08T15:15:12.614Z",
    "dateReserved": "2026-06-07T19:42:14.647Z",
    "dateUpdated": "2026-06-09T14:35:55.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11524 (GCVE-0-2026-11524)

Vulnerability from cvelistv5 – Published: 2026-06-08 15:00 – Updated: 2026-06-09 15:26
VLAI
Title
Tenda W20E Web Management modifyWifiFilterRules stack-based overflow
Summary
A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W20E Affected: 15.11.0.6
    cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hacker128 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11524",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-09T15:25:13.664719Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-09T15:26:03.032Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "W20E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T15:00:16.713Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369144 | Tenda W20E Web Management modifyWifiFilterRules stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369144"
        },
        {
          "name": "VDB-369144 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369144/cti"
        },
        {
          "name": "CVE-2026-11524 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11524"
        },
        {
          "name": "Submit #836478 | Tenda Tenda W20E Enterprise Router  V15.11.0.6 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836478"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWifiFilterRulesModify/modifyWifiFilterRules.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T18:12:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W20E Web Management modifyWifiFilterRules stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11524",
    "datePublished": "2026-06-08T15:00:16.713Z",
    "dateReserved": "2026-06-07T16:07:35.577Z",
    "dateUpdated": "2026-06-09T15:26:03.032Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11523 (GCVE-0-2026-11523)

Vulnerability from cvelistv5 – Published: 2026-06-08 14:45 – Updated: 2026-06-08 16:36
VLAI
Title
Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow
Summary
A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W20E Affected: 15.11.0.6
    cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hacker128 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11523",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T16:35:00.338505Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T16:36:03.017Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "W20E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T14:45:09.883Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369143 | Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369143"
        },
        {
          "name": "VDB-369143 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369143/cti"
        },
        {
          "name": "CVE-2026-11523 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11523"
        },
        {
          "name": "Submit #836471 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836471"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T18:11:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11523",
    "datePublished": "2026-06-08T14:45:09.883Z",
    "dateReserved": "2026-06-07T16:06:42.495Z",
    "dateUpdated": "2026-06-08T16:36:03.017Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11522 (GCVE-0-2026-11522)

Vulnerability from cvelistv5 – Published: 2026-06-08 14:30 – Updated: 2026-06-08 15:52
VLAI
Title
Tenda W20E setPortMirror formSetPortMirror stack-based overflow
Summary
A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W20E Affected: 15.11.0.6
    cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hacker128 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11522",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T15:52:11.957984Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T15:52:25.265Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "W20E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hacker128 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T14:30:11.465Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369142 | Tenda W20E setPortMirror formSetPortMirror stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369142"
        },
        {
          "name": "VDB-369142 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369142/cti"
        },
        {
          "name": "CVE-2026-11522 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11522"
        },
        {
          "name": "Submit #836469 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836469"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formSetPortMirror/portMirrorMirroredPorts.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T18:11:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W20E setPortMirror formSetPortMirror stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11522",
    "datePublished": "2026-06-08T14:30:11.465Z",
    "dateReserved": "2026-06-07T16:06:39.937Z",
    "dateUpdated": "2026-06-08T15:52:25.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11504 (GCVE-0-2026-11504)

Vulnerability from cvelistv5 – Published: 2026-06-08 10:00 – Updated: 2026-06-08 12:57
VLAI
Title
Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369124 vdb-entrytechnical-description
https://vuldb.com/vuln/369124/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11504 third-party-advisory
https://vuldb.com/submit/835649 third-party-advisory
https://github.com/cve-a/moist/issues/2 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda CX12L Affected: 16.03.53.12
    cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11504",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:57:07.691843Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T12:57:17.537Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Wi-Fi Schedule Configuration Endpoint"
          ],
          "product": "CX12L",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.53.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T10:00:13.594Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369124 | Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369124"
        },
        {
          "name": "VDB-369124 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369124/cti"
        },
        {
          "name": "CVE-2026-11504 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11504"
        },
        {
          "name": "Submit #835649 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/835649"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/cve-a/moist/issues/2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T16:06:25.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11504",
    "datePublished": "2026-06-08T10:00:13.594Z",
    "dateReserved": "2026-06-07T14:01:17.439Z",
    "dateUpdated": "2026-06-08T12:57:17.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11503 (GCVE-0-2026-11503)

Vulnerability from cvelistv5 – Published: 2026-06-08 09:45 – Updated: 2026-06-08 16:22
VLAI
Title
Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
Summary
A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369123 vdb-entrytechnical-description
https://vuldb.com/vuln/369123/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11503 third-party-advisory
https://vuldb.com/submit/835648 third-party-advisory
https://github.com/cve-a/moist/issues/1 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda CX12L Affected: 16.03.53.12
    cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11503",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:46:27.133276Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T16:22:19.524Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Wi-Fi Configuration Endpoint"
          ],
          "product": "CX12L",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.53.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T09:45:12.620Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369123 | Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369123"
        },
        {
          "name": "VDB-369123 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369123/cti"
        },
        {
          "name": "CVE-2026-11503 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11503"
        },
        {
          "name": "Submit #835648 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/835648"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/cve-a/moist/issues/1"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T16:06:22.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11503",
    "datePublished": "2026-06-08T09:45:12.620Z",
    "dateReserved": "2026-06-07T14:01:15.075Z",
    "dateUpdated": "2026-06-08T16:22:19.524Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11499 (GCVE-0-2026-11499)

Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
VLAI
Title
Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369119 vdb-entrytechnical-description
https://vuldb.com/vuln/369119/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
https://vuldb.com/submit/834888 third-party-advisory
https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11499",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:55:19.613788Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T12:55:29.374Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T07:00:23.672Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369119"
        },
        {
          "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369119/cti"
        },
        {
          "name": "CVE-2026-11499 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11499"
        },
        {
          "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834888"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T15:28:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11499",
    "datePublished": "2026-06-08T07:00:23.672Z",
    "dateReserved": "2026-06-07T13:23:38.138Z",
    "dateUpdated": "2026-06-08T12:55:29.374Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11498 (GCVE-0-2026-11498)

Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
VLAI
Title
Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369118 vdb-entrytechnical-description
https://vuldb.com/vuln/369118/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
https://vuldb.com/submit/834887 third-party-advisory
https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11498",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:47:31.920390Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T16:22:24.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T06:45:21.289Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369118"
        },
        {
          "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369118/cti"
        },
        {
          "name": "CVE-2026-11498 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11498"
        },
        {
          "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834887"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T15:27:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11498",
    "datePublished": "2026-06-08T06:45:21.289Z",
    "dateReserved": "2026-06-07T13:22:12.336Z",
    "dateUpdated": "2026-06-08T16:22:24.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11493 (GCVE-0-2026-11493)

Vulnerability from cvelistv5 – Published: 2026-06-08 05:45 – Updated: 2026-06-08 13:30
VLAI
Title
Tenda AC15 Samba smb.conf weak password
Summary
A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-521 - Weak Password Requirements
Assigner
References
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.05.19
    cpe:2.3:o:tenda:ac15_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
L-14 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11493",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T13:30:33.197769Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T13:30:41.606Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac15_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Samba"
          ],
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "L-14 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4.3,
            "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-521",
              "description": "Weak Password Requirements",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T05:45:09.868Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369113 | Tenda AC15 Samba smb.conf weak password",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/vuln/369113"
        },
        {
          "name": "VDB-369113 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369113/cti"
        },
        {
          "name": "CVE-2026-11493 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11493"
        },
        {
          "name": "Submit #834818 | Tenda AC15 V15.03.05.19 Misconfiguration",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834818"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.notion.so/Tenda-AC15-V15-03-05-19-3671f5ba98908023b508dc0330624dcd?source=copy_link"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T12:23:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 Samba smb.conf weak password"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11493",
    "datePublished": "2026-06-08T05:45:09.868Z",
    "dateReserved": "2026-06-07T10:18:43.938Z",
    "dateUpdated": "2026-06-08T13:30:41.606Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-10192 (GCVE-0-2026-10192)

Vulnerability from cvelistv5 – Published: 2026-05-31 16:00 – Updated: 2026-06-01 12:29
VLAI
Title
Tenda W12 httpd set_local_time_0 stack-based overflow
Summary
A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W12 Affected: 3.0.0.7(4763)
    cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CookedMelon (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-10192",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-01T12:29:33.921006Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-01T12:29:51.172Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "W12",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "3.0.0.7(4763)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CookedMelon (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-31T16:00:13.456Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-367473 | Tenda W12 httpd set_local_time_0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/367473"
        },
        {
          "name": "VDB-367473 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/367473/cti"
        },
        {
          "name": "CVE-2026-10192 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-10192"
        },
        {
          "name": "Submit #820024 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/820024"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "http://cdn2.v50to.cc/set_local_time_0_overflow.zip"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-30T18:52:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W12 httpd set_local_time_0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-10192",
    "datePublished": "2026-05-31T16:00:13.456Z",
    "dateReserved": "2026-05-30T16:45:18.912Z",
    "dateUpdated": "2026-06-01T12:29:51.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-10191 (GCVE-0-2026-10191)

Vulnerability from cvelistv5 – Published: 2026-05-31 15:45 – Updated: 2026-06-01 15:24
VLAI
Title
Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow
Summary
A vulnerability was determined in Tenda W12 3.0.0.7(4763). Impacted is the function cgiWifiMacFilterSet of the file /bin/httpd. This manipulation of the argument wifiMacFilterSet.macList.mac causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W12 Affected: 3.0.0.7(4763)
    cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CookedMelon (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-10191",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-01T15:16:43.874685Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-01T15:24:11.577Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "W12",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "3.0.0.7(4763)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CookedMelon (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda W12 3.0.0.7(4763). Impacted is the function cgiWifiMacFilterSet of the file /bin/httpd. This manipulation of the argument wifiMacFilterSet.macList.mac causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-31T15:45:14.535Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-367472 | Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/367472"
        },
        {
          "name": "VDB-367472 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/367472/cti"
        },
        {
          "name": "CVE-2026-10191 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-10191"
        },
        {
          "name": "Submit #820023 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/820023"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "http://cdn2.v50to.cc/cgiWifiMacFilterSet_overflow.zip"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-30T18:52:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W12 httpd cgiWifiMacFilterSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-10191",
    "datePublished": "2026-05-31T15:45:14.535Z",
    "dateReserved": "2026-05-30T16:45:16.184Z",
    "dateUpdated": "2026-06-01T15:24:11.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-10190 (GCVE-0-2026-10190)

Vulnerability from cvelistv5 – Published: 2026-05-31 15:30 – Updated: 2026-06-01 15:04
VLAI
Title
Tenda W12 Web Management httpd cgiSysWebTimeoutSet denial of service
Summary
A vulnerability was found in Tenda W12 3.0.0.7(4763). This issue affects the function cgiSysWebTimeoutSet of the file /bin/httpd of the component Web Management Interface. The manipulation of the argument web_over_time results in denial of service. It is possible to launch the attack remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/367471 vdb-entrytechnical-description
https://vuldb.com/vuln/367471/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-10190 third-party-advisory
https://vuldb.com/submit/820022 third-party-advisory
http://cdn2.v50to.cc/cgiSysWebTimeoutSet_dos.zip exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda W12 Affected: 3.0.0.7(4763)
    cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CookedMelon (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-10190",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-01T15:04:47.302906Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-01T15:04:52.891Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://vuldb.com/submit/820022"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "W12",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "3.0.0.7(4763)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CookedMelon (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W12 3.0.0.7(4763). This issue affects the function cgiSysWebTimeoutSet of the file /bin/httpd of the component Web Management Interface. The manipulation of the argument web_over_time results in denial of service. It is possible to launch the attack remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-31T15:30:13.999Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-367471 | Tenda W12 Web Management httpd cgiSysWebTimeoutSet denial of service",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/367471"
        },
        {
          "name": "VDB-367471 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/367471/cti"
        },
        {
          "name": "CVE-2026-10190 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-10190"
        },
        {
          "name": "Submit #820022 | Tenda W12 V3.0.0.7(4763) Denial of Service",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/820022"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "http://cdn2.v50to.cc/cgiSysWebTimeoutSet_dos.zip"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-30T18:52:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W12 Web Management httpd cgiSysWebTimeoutSet denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-10190",
    "datePublished": "2026-05-31T15:30:13.999Z",
    "dateReserved": "2026-05-30T16:45:13.485Z",
    "dateUpdated": "2026-06-01T15:04:52.891Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-10189 (GCVE-0-2026-10189)

Vulnerability from cvelistv5 – Published: 2026-05-31 15:00 – Updated: 2026-06-01 13:28
VLAI
Title
Tenda W12 httpd cgiSysTimeInfoSet stack-based overflow
Summary
A vulnerability has been found in Tenda W12 3.0.0.7(4763). This vulnerability affects the function cgiSysTimeInfoSet of the file /bin/httpd. The manipulation of the argument sec leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W12 Affected: 3.0.0.7(4763)
    cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CookedMelon (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-10189",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-01T13:28:26.403905Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-01T13:28:34.971Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "W12",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "3.0.0.7(4763)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CookedMelon (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda W12 3.0.0.7(4763). This vulnerability affects the function cgiSysTimeInfoSet of the file /bin/httpd. The manipulation of the argument sec leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-31T15:00:14.812Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-367470 | Tenda W12 httpd cgiSysTimeInfoSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/367470"
        },
        {
          "name": "VDB-367470 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/367470/cti"
        },
        {
          "name": "CVE-2026-10189 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-10189"
        },
        {
          "name": "Submit #820021 | Tenda W12 V3.0.0.7(4763) stack",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/820021"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "http://cdn2.v50to.cc/cgiSysTimeInfoSet_overflow.zip"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-30T18:52:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W12 httpd cgiSysTimeInfoSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-10189",
    "datePublished": "2026-05-31T15:00:14.812Z",
    "dateReserved": "2026-05-30T16:45:10.724Z",
    "dateUpdated": "2026-06-01T13:28:34.971Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-10188 (GCVE-0-2026-10188)

Vulnerability from cvelistv5 – Published: 2026-05-31 14:30 – Updated: 2026-06-02 14:53
VLAI
Title
Tenda W12 httpd cgistaKickOff stack-based overflow
Summary
A flaw has been found in Tenda W12 3.0.0.7(4763). This affects the function cgistaKickOff of the file /bin/httpd. Executing a manipulation of the argument staMac can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda W12 Affected: 3.0.0.7(4763)
    cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
CookedMelon (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-10188",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-02T14:53:02.632917Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-02T14:53:18.148Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:w12_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "W12",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "3.0.0.7(4763)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "CookedMelon (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda W12 3.0.0.7(4763). This affects the function cgistaKickOff of the file /bin/httpd. Executing a manipulation of the argument staMac can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-31T14:30:12.458Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-367469 | Tenda W12 httpd cgistaKickOff stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/367469"
        },
        {
          "name": "VDB-367469 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/367469/cti"
        },
        {
          "name": "CVE-2026-10188 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-10188"
        },
        {
          "name": "Submit #820018 | Tenda W12 V3.0.0.7(4763) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/820018"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "http://cdn2.v50to.cc/Tenda%20W12%20cgistaKickOff%20overflow.zip"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-30T18:52:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W12 httpd cgistaKickOff stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-10188",
    "datePublished": "2026-05-31T14:30:12.458Z",
    "dateReserved": "2026-05-30T16:45:07.942Z",
    "dateUpdated": "2026-06-02T14:53:18.148Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9431 (GCVE-0-2026-9431)

Vulnerability from cvelistv5 – Published: 2026-05-25 05:45 – Updated: 2026-05-26 13:12
VLAI
Title
Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow
Summary
A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda F1202 Affected: 1.2.0.20(408)
    cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
LtzHuster2 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9431",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-26T13:12:02.867879Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-26T13:12:09.259Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "F1202",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.20(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LtzHuster2 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-25T05:45:10.169Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-365412 | Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/365412"
        },
        {
          "name": "VDB-365412 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/365412/cti"
        },
        {
          "name": "Submit #813916 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/813916"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_35/README.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-24T09:08:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-9431",
    "datePublished": "2026-05-25T05:45:10.169Z",
    "dateReserved": "2026-05-24T07:03:29.836Z",
    "dateUpdated": "2026-05-26T13:12:09.259Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9430 (GCVE-0-2026-9430)

Vulnerability from cvelistv5 – Published: 2026-05-25 05:30 – Updated: 2026-05-28 12:38
VLAI
Title
Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow
Summary
A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda F1202 Affected: 1.2.0.20(408)
    cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
LtzHuster2 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9430",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-28T12:37:19.410093Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-28T12:38:04.357Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "F1202",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.20(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LtzHuster2 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-25T05:30:12.026Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-365411 | Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/365411"
        },
        {
          "name": "VDB-365411 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/365411/cti"
        },
        {
          "name": "Submit #813915 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/813915"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_32/README.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-24T09:08:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-9430",
    "datePublished": "2026-05-25T05:30:12.026Z",
    "dateReserved": "2026-05-24T07:03:24.648Z",
    "dateUpdated": "2026-05-28T12:38:04.357Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9429 (GCVE-0-2026-9429)

Vulnerability from cvelistv5 – Published: 2026-05-25 05:15 – Updated: 2026-05-26 16:05
VLAI
Title
Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow
Summary
A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/365410 vdb-entrytechnical-description
https://vuldb.com/vuln/365410/cti signaturepermissions-required
https://vuldb.com/submit/813912 third-party-advisory
https://github.com/Litengzheng/vuldb_new2/blob/ma… exploit
https://www.tenda.com.cn/ broken-linkproduct
Impacted products
Vendor Product Version
Tenda F1202 Affected: 1.2.0.20(408)
    cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
LtzHuster2 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9429",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-26T16:05:34.410649Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-26T16:05:41.704Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "F1202",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.20(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LtzHuster2 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-25T05:15:09.759Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-365410 | Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/365410"
        },
        {
          "name": "VDB-365410 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/365410/cti"
        },
        {
          "name": "Submit #813912 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/813912"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_31/README.md"
        },
        {
          "tags": [
            "broken-link",
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-24T09:08:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-9429",
    "datePublished": "2026-05-25T05:15:09.759Z",
    "dateReserved": "2026-05-24T07:03:22.153Z",
    "dateUpdated": "2026-05-26T16:05:41.704Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9428 (GCVE-0-2026-9428)

Vulnerability from cvelistv5 – Published: 2026-05-25 05:00 – Updated: 2026-05-28 18:37
VLAI
Title
Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow
Summary
A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda F1202 Affected: 1.2.0.20(408)
    cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
LtzHuster2 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9428",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-28T18:36:36.235807Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-28T18:37:05.367Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f1202_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "F1202",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.20(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LtzHuster2 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-25T05:00:14.895Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-365409 | Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/365409"
        },
        {
          "name": "VDB-365409 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/365409/cti"
        },
        {
          "name": "Submit #813911 | Tenda F1202 V1.2.0.20(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/813911"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Litengzheng/vuldb_new2/blob/main/F1202/vul_29/README.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-24T09:08:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-9428",
    "datePublished": "2026-05-25T05:00:14.895Z",
    "dateReserved": "2026-05-24T07:03:19.502Z",
    "dateUpdated": "2026-05-28T18:37:05.367Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9389 (GCVE-0-2026-9389)

Vulnerability from cvelistv5 – Published: 2026-05-24 14:45 – Updated: 2026-05-29 18:19
VLAI
Title
Tenda F456 L7Im frmL7ImForm buffer overflow
Summary
A security vulnerability has been detected in Tenda F456 1.0.0.5. This affects the function frmL7ImForm of the file /goform/L7Im. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda F456 Affected: 1.0.0.5
    cpe:2.3:o:tenda:f456_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
LtzHust (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9389",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-29T18:18:56.691204Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-29T18:19:04.590Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:f456_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "F456",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.5"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LtzHust (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda F456 1.0.0.5. This affects the function frmL7ImForm of the file /goform/L7Im. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-24T14:45:09.119Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-365352 | Tenda F456 L7Im frmL7ImForm buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/365352"
        },
        {
          "name": "VDB-365352 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/365352/cti"
        },
        {
          "name": "Submit #813444 | tenda F456 v1.0.0.5 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/813444"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Litengzheng/vuldb_new/blob/main/F456/vul_2/README.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-23T17:09:13.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F456 L7Im frmL7ImForm buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-9389",
    "datePublished": "2026-05-24T14:45:09.119Z",
    "dateReserved": "2026-05-23T15:04:09.855Z",
    "dateUpdated": "2026-05-29T18:19:04.590Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-8265 (GCVE-0-2026-8265)

Vulnerability from cvelistv5 – Published: 2026-05-11 02:30 – Updated: 2026-05-11 10:42
VLAI
Title
Tenda AC6 httpd getLogFile get_log_file os command injection
Summary
A security vulnerability has been detected in Tenda AC6 15.03.06.23. Affected by this issue is the function get_log_file of the file /goform/getLogFile of the component httpd. The manipulation of the argument wans.flag leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC6 Affected: 15.03.06.23
    cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
ST4R (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-8265",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-11T10:42:07.291164Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-11T10:42:35.091Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "httpd"
          ],
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.23"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ST4R (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC6 15.03.06.23. Affected by this issue is the function get_log_file of the file /goform/getLogFile of the component httpd. The manipulation of the argument wans.flag leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-11T02:30:14.220Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-362562 | Tenda AC6 httpd getLogFile get_log_file os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/362562"
        },
        {
          "name": "VDB-362562 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/362562/cti"
        },
        {
          "name": "Submit #810076 | Tenda AC6 V2.0 (AC1206)  Firmware V15.03.06.23 Command Injection via wans.flag",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/810076"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Tenda%20AC6V2%20get_log_file%20Command%20Injection%20via%20wans.flag.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-10T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-10T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-10T17:40:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6 httpd getLogFile get_log_file os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-8265",
    "datePublished": "2026-05-11T02:30:14.220Z",
    "dateReserved": "2026-05-10T15:35:42.308Z",
    "dateUpdated": "2026-05-11T10:42:35.091Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-8264 (GCVE-0-2026-8264)

Vulnerability from cvelistv5 – Published: 2026-05-11 02:15 – Updated: 2026-05-11 12:47
VLAI
Title
Tenda AC6 httpd WifiApScan formWifiApScan os command injection
Summary
A weakness has been identified in Tenda AC6 15.03.06.23. Affected by this vulnerability is the function formWifiApScan of the file /goform/WifiApScan of the component httpd. Executing a manipulation of the argument wl2g.public.country/wl5g.public.country can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC6 Affected: 15.03.06.23
    cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
ST4R (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-8264",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-11T12:47:50.499938Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-11T12:47:59.722Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "httpd"
          ],
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.23"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ST4R (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda AC6 15.03.06.23. Affected by this vulnerability is the function formWifiApScan of the file /goform/WifiApScan of the component httpd. Executing a manipulation of the argument wl2g.public.country/wl5g.public.country can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-11T02:15:09.627Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-362561 | Tenda AC6 httpd WifiApScan formWifiApScan os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/362561"
        },
        {
          "name": "VDB-362561 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/362561/cti"
        },
        {
          "name": "Submit #810075 | Tenda  AC6 V2.0 (AC1206) Firmware V15.03.06.23 Command Injection via country parameter",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/810075"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Tenda%20AC6V2%20formWifiApScan%20Command%20Injection%20via%20country%20parameter.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-10T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-10T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-10T17:40:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6 httpd WifiApScan formWifiApScan os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-8264",
    "datePublished": "2026-05-11T02:15:09.627Z",
    "dateReserved": "2026-05-10T15:35:39.391Z",
    "dateUpdated": "2026-05-11T12:47:59.722Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-8263 (GCVE-0-2026-8263)

Vulnerability from cvelistv5 – Published: 2026-05-11 02:00 – Updated: 2026-05-11 17:31
VLAI
Title
Tenda AC6 httpd WifiExtraSet fromSetWirelessRepeat os command injection
Summary
A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC6 Affected: 15.03.06.49_multi_TDE01
    cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
ST4R (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-8263",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-11T15:56:51.720245Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-11T17:31:16.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "httpd"
          ],
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ST4R (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-11T02:00:16.521Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-362560 | Tenda AC6 httpd WifiExtraSet fromSetWirelessRepeat os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/362560"
        },
        {
          "name": "VDB-362560 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/362560/cti"
        },
        {
          "name": "Submit #810074 | Tenda AC6 V2.0 (AC1206) Firmware V15.03.06.23 Command Injection via mac/ssid",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/810074"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromSetWirelessRepeat.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-10T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-10T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-10T17:40:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6 httpd WifiExtraSet fromSetWirelessRepeat os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-8263",
    "datePublished": "2026-05-11T02:00:16.521Z",
    "dateReserved": "2026-05-10T15:35:34.814Z",
    "dateUpdated": "2026-05-11T17:31:16.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-8259 (GCVE-0-2026-8259)

Vulnerability from cvelistv5 – Published: 2026-05-11 01:00 – Updated: 2026-05-11 10:55
VLAI
Title
Tenda AC6 httpd telnet os command injection
Summary
A vulnerability has been found in Tenda AC6 2.0/15.03.06.23. The affected element is an unknown function of the file /goform/telnet of the component httpd. The manipulation of the argument lan.ip leads to os command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC6 Affected: 2.0
Affected: 15.03.06.23
    cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
ST4R (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-8259",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-11T10:43:55.544959Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-11T10:55:16.853Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac6_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "httpd"
          ],
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0"
            },
            {
              "status": "affected",
              "version": "15.03.06.23"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ST4R (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC6 2.0/15.03.06.23. The affected element is an unknown function of the file /goform/telnet of the component httpd. The manipulation of the argument lan.ip leads to os command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-11T01:00:15.246Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-362556 | Tenda AC6 httpd telnet os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/362556"
        },
        {
          "name": "VDB-362556 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/362556/cti"
        },
        {
          "name": "Submit #809877 | Tenda AC6 V2.0 (AC1206) Firmware V15.03.06.23 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/809877"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Tenda%20AC6V2%20TendaTelnet%20Command%20Injection.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-10T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-10T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-10T17:13:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6 httpd telnet os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-8259",
    "datePublished": "2026-05-11T01:00:15.246Z",
    "dateReserved": "2026-05-10T15:07:35.155Z",
    "dateUpdated": "2026-05-11T10:55:16.853Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-8138 (GCVE-0-2026-8138)

Vulnerability from cvelistv5 – Published: 2026-05-08 04:15 – Updated: 2026-05-08 10:35
VLAI
Title
Tenda CX12L SetPptpServerCfg” formSetPPTPServer stack-based overflow
Summary
A vulnerability was found in Tenda CX12L 16.03.53.12. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg”. The manipulation results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/361927 vdb-entrytechnical-description
https://vuldb.com/vuln/361927/cti signaturepermissions-required
https://vuldb.com/submit/808867 third-party-advisory
https://github.com/cve-a/lvdan/issues/6 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda CX12L Affected: 16.03.53.12
    cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
lv1020 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-8138",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-08T10:29:13.853980Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-08T10:35:06.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "CX12L",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.53.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lv1020 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda CX12L 16.03.53.12. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg\u201d. The manipulation results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-08T04:15:10.228Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-361927 | Tenda CX12L SetPptpServerCfg\u201d formSetPPTPServer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/361927"
        },
        {
          "name": "VDB-361927 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/361927/cti"
        },
        {
          "name": "Submit #808867 | Tenda  CX12L  V16.03.53.12 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/808867"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/cve-a/lvdan/issues/6"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-05-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-05-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-05-07T20:03:09.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda CX12L SetPptpServerCfg\u201d formSetPPTPServer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-8138",
    "datePublished": "2026-05-08T04:15:10.228Z",
    "dateReserved": "2026-05-07T17:58:06.120Z",
    "dateUpdated": "2026-05-08T10:35:06.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-7470 (GCVE-0-2026-7470)

Vulnerability from cvelistv5 – Published: 2026-04-30 02:30 – Updated: 2026-05-04 13:22
VLAI
Title
Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow
Summary
A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/360206 vdb-entrytechnical-description
https://vuldb.com/vuln/360206/cti signaturepermissions-required
https://vuldb.com/submit/804269 third-party-advisory
https://github.com/Axelioc/CVE/blob/main/Tenda/US… broken-linkexploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda 4G300 Affected: US_4G300V1.0Mt_V1.01.42_CN_TDC01
    cpe:2.3:o:tenda:4g300_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Haaalion (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-7470",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-04T13:22:33.682577Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-04T13:22:41.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:4g300_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "US_4G300V1.0Mt_V1.01.42_CN_TDC01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Haaalion (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-30T02:30:13.346Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-360206 | Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/360206"
        },
        {
          "name": "VDB-360206 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/360206/cti"
        },
        {
          "name": "Submit #804269 | Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/804269"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/Axelioc/CVE/blob/main/Tenda/US_4G300/sub_427C3C/sub_427C3C.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-29T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-29T21:26:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-7470",
    "datePublished": "2026-04-30T02:30:13.346Z",
    "dateReserved": "2026-04-29T19:21:15.379Z",
    "dateUpdated": "2026-05-04T13:22:41.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-7469 (GCVE-0-2026-7469)

Vulnerability from cvelistv5 – Published: 2026-04-30 01:45 – Updated: 2026-04-30 13:44
VLAI
Title
Tenda 4G300 DelFil sub_425A28 command injection
Summary
A vulnerability was detected in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. This impacts the function sub_425A28 of the file /goform/DelFil. The manipulation of the argument delflag results in command injection. The attack may be launched remotely. The exploit is now public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/360205 vdb-entrytechnical-description
https://vuldb.com/vuln/360205/cti signaturepermissions-required
https://vuldb.com/submit/804268 third-party-advisory
https://github.com/Axelioc/CVE/blob/main/Tenda/US… broken-linkexploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda 4G300 Affected: US_4G300V1.0Mt_V1.01.42_CN_TDC01
    cpe:2.3:o:tenda:4g300_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Haaalion (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-7469",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-30T13:43:11.089602Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-30T13:44:18.276Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:4g300_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "US_4G300V1.0Mt_V1.01.42_CN_TDC01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Haaalion (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. This impacts the function sub_425A28 of the file /goform/DelFil. The manipulation of the argument delflag results in command injection. The attack may be launched remotely. The exploit is now public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-30T01:45:10.912Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-360205 | Tenda 4G300 DelFil sub_425A28 command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/360205"
        },
        {
          "name": "VDB-360205 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/360205/cti"
        },
        {
          "name": "Submit #804268 | Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/804268"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/Axelioc/CVE/blob/main/Tenda/US_4G300/sub_425A28/sub_425A28.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-04-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-04-29T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-04-29T21:26:20.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 DelFil sub_425A28 command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-7469",
    "datePublished": "2026-04-30T01:45:10.912Z",
    "dateReserved": "2026-04-29T19:21:10.675Z",
    "dateUpdated": "2026-04-30T13:44:18.276Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2018-25318 (GCVE-0-2018-25318)

Vulnerability from cvelistv5 – Published: 2026-04-29 19:24 – Updated: 2026-04-30 15:22
VLAI
Title
Tenda FH303/A300 V5.07.68_EN Cookie Session Weakness DNS Change
Summary
Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin cookie to change DNS servers and redirect user traffic to malicious sites.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-290 - Authentication Bypass by Spoofing
Assigner
References
Impacted products
Vendor Product Version
Tenda FH303/A300 Affected: 5.07.68
Create a notification for this product.
Date Public
2018-03-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2018-25318",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-30T13:13:33.905364Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-30T15:22:22.014Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH303/A300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "5.07.68"
            }
          ]
        }
      ],
      "datePublic": "2018-03-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin cookie to change DNS servers and redirect user traffic to malicious sites."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS"
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-290",
              "description": "Authentication Bypass by Spoofing",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-29T19:51:40.636Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "name": "ExploitDB-44381",
          "tags": [
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/44381"
        },
        {
          "name": "VulnCheck Advisory: Tenda FH303/A300 V5.07.68_EN Cookie Session Weakness DNS Change",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/tenda-fh303-a300-68-en-cookie-session-weakness-dns-change"
        }
      ],
      "title": "Tenda FH303/A300 V5.07.68_EN Cookie Session Weakness DNS Change",
      "x_generator": {
        "engine": "vulncheck"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2018-25318",
    "datePublished": "2026-04-29T19:24:46.207Z",
    "dateReserved": "2026-04-29T12:27:37.000Z",
    "dateUpdated": "2026-04-30T15:22:22.014Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}