Search

Find a vulnerability

Search criteria

    3692 vulnerabilities by Tenda

    CVE-2026-115797 (GCVE-0-2026-115797)

    Vulnerability from nvd – Published: 2026-10-23 20:00 – Updated: 2026-10-23 20:00
    VLAI
    Title
    Tenda F6 Web Management cleartext transmission
    Summary
    A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks.
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    • CWE-310 - Cryptographic Issues
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 2.6,
                "vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-310",
                  "description": "Cryptographic Issues",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-23T20:00:16.370Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425975 | Tenda F6 Web Management cleartext transmission",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/425975"
            },
            {
              "name": "VDB-425975 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425975/cti"
            },
            {
              "name": "CVE-2026-115797 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115797"
            },
            {
              "name": "Submit #1022076 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cleartext Transmission of Sensitive Information (CWE-319)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022076"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/edit/main/02-Cleartext_Transmission.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-23T18:17:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cleartext transmission",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115797",
        "datePublished": "2026-10-23T20:00:16.370Z",
        "dateReserved": "2026-10-23T14:57:47.218Z",
        "dateUpdated": "2026-10-23T20:00:16.370Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115796 (GCVE-0-2026-115796)

    Vulnerability from nvd – Published: 2026-10-23 19:45 – Updated: 2026-10-23 19:45
    VLAI
    Title
    Tenda F6 Web Management cross-site request forgery
    Summary
    A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.
    CWE
    • CWE-352 - Cross-Site Request Forgery
    • CWE-862 - Missing Authorization
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-23T19:45:19.860Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425974 | Tenda F6 Web Management cross-site request forgery",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/425974"
            },
            {
              "name": "VDB-425974 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425974/cti"
            },
            {
              "name": "CVE-2026-115796 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115796"
            },
            {
              "name": "Submit #1022074 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cross-Site Request Forgery (CWE-352)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022074"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/blob/main/01-csrf.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-23T18:17:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cross-site request forgery",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115796",
        "datePublished": "2026-10-23T19:45:19.860Z",
        "dateReserved": "2026-10-23T14:57:43.016Z",
        "dateUpdated": "2026-10-23T19:45:19.860Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-114268 (GCVE-0-2026-114268)

    Vulnerability from nvd – Published: 2026-10-21 18:45 – Updated: 2026-10-21 18:45
    VLAI
    Title
    Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow
    Summary
    A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/424700 vdb-entrytechnical-description
    https://vuldb.com/vuln/424700/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-114268 third-party-advisory
    https://vuldb.com/submit/1018994 third-party-advisory
    https://github.com/Tmzop/Tenda-CVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda BE3L Pro Affected: 16.03.60.62
        cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*"
              ],
              "product": "BE3L Pro",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.60.62"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T18:45:12.143Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-424700 | Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/424700"
            },
            {
              "name": "VDB-424700 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/424700/cti"
            },
            {
              "name": "CVE-2026-114268 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-114268"
            },
            {
              "name": "Submit #1018994 | Tenda Tenda Router BE3L Pro V16.03.60.62 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018994"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-CVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-21T09:01:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-114268",
        "datePublished": "2026-10-21T18:45:12.143Z",
        "dateReserved": "2026-10-21T06:51:52.604Z",
        "dateUpdated": "2026-10-21T18:45:12.143Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-113744 (GCVE-0-2026-113744)

    Vulnerability from nvd – Published: 2026-10-21 01:30 – Updated: 2026-10-21 01:30
    VLAI
    Title
    Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/422925 vdb-entrytechnical-description
    https://vuldb.com/vuln/422925/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-113744 third-party-advisory
    https://vuldb.com/submit/1018542 third-party-advisory
    https://github.com/henrythekingofuk/TendaCVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Service"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeming Hu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T01:30:24.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-422925 | Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/422925"
            },
            {
              "name": "VDB-422925 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/422925/cti"
            },
            {
              "name": "CVE-2026-113744 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-113744"
            },
            {
              "name": "Submit #1018542 | Tenda AC19 V16.03.10.07 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018542"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/henrythekingofuk/TendaCVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-20T18:58:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-113744",
        "datePublished": "2026-10-21T01:30:24.075Z",
        "dateReserved": "2026-10-20T16:53:34.154Z",
        "dateUpdated": "2026-10-21T01:30:24.075Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-105778 (GCVE-0-2026-105778)

    Vulnerability from nvd – Published: 2026-10-06 06:45 – Updated: 2026-10-06 17:40
    VLAI
    Title
    Tenda AC5 Wifi setWifi stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-06 17:07 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda AC5 Affected: 02.03.01.111_multi
        cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-105778",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-06T17:07:05.050647Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-06T17:40:19.337Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wifi Handler"
              ],
              "product": "AC5",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "02.03.01.111_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "raisecnull (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-06T06:45:13.774Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-413811 | Tenda AC5 Wifi setWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/413811"
            },
            {
              "name": "VDB-413811 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/413811/cti"
            },
            {
              "name": "CVE-2026-105778 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-105778"
            },
            {
              "name": "Submit #992587 | Tenda AC5 V02.03.01.111_multi Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/992587"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/raisecnull/Tenda-AC5v3-BOF/blob/main/blog.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-05T22:40:11.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC5 Wifi setWifi stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-105778",
        "datePublished": "2026-10-06T06:45:13.774Z",
        "dateReserved": "2026-10-05T20:34:57.881Z",
        "dateUpdated": "2026-10-06T17:40:19.337Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-104611 (GCVE-0-2026-104611)

    Vulnerability from nvd – Published: 2026-10-02 12:15 – Updated: 2026-10-02 13:30
    VLAI
    Title
    Tenda AC9 POST Request fast_setting_internet_set stack-based overflow
    Summary
    A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:30 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:30:30.834838Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:30:49.550Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hodor (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:15:15.494Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412918 | Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412918"
            },
            {
              "name": "VDB-412918 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412918/cti"
            },
            {
              "name": "CVE-2026-104611 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104611"
            },
            {
              "name": "Submit #962720 | Tenda RouterOS AC9V1.0BR_V15.03.2.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962720"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/ZaneBoden/CVEs/blob/main/Tenda-AC9-fast_setting_internet_set.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:56:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104611",
        "datePublished": "2026-10-02T12:15:15.494Z",
        "dateReserved": "2026-10-02T03:51:51.618Z",
        "dateUpdated": "2026-10-02T13:30:49.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-104610 (GCVE-0-2026-104610)

    Vulnerability from nvd – Published: 2026-10-02 12:00 – Updated: 2026-10-02 13:50
    VLAI
    Title
    Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:49 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/412917 vdb-entrytechnical-description
    https://vuldb.com/vuln/412917/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-104610 third-party-advisory
    https://vuldb.com/submit/962541 third-party-advisory
    https://github.com/Expl0rer-Ct/CVE/issues/1 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104610",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:49:47.985467Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:50:12.393Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Expl0rer.Ct (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:00:18.544Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412917 | Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412917"
            },
            {
              "name": "VDB-412917 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412917/cti"
            },
            {
              "name": "CVE-2026-104610 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104610"
            },
            {
              "name": "Submit #962541 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962541"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/Expl0rer-Ct/CVE/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:54:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104610",
        "datePublished": "2026-10-02T12:00:18.544Z",
        "dateReserved": "2026-10-02T03:49:26.992Z",
        "dateUpdated": "2026-10-02T13:50:12.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-90689 (GCVE-0-2026-90689)

    Vulnerability from nvd – Published: 2026-09-14 06:15 – Updated: 2026-09-14 10:55
    VLAI
    Title
    Tenda W20E formDelWebAuthWhiteUser stack-based overflow
    Summary
    A security flaw has been discovered in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. Impacted is the function formDelWebAuthWhiteUser. Performing a manipulation of the argument webAuthWhiteUserIndex results in stack-based buffer overflow. The attack can be initiated remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 10:54 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.61068_1546_841_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-90689",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T10:54:39.870335Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T10:55:57.386Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.61068_1546_841_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "AmaIIl (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. Impacted is the function formDelWebAuthWhiteUser. Performing a manipulation of the argument webAuthWhiteUserIndex results in stack-based buffer overflow. The attack can be initiated remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:15:08.707Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-403222 | Tenda W20E formDelWebAuthWhiteUser stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/403222"
            },
            {
              "name": "VDB-403222 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/403222/cti"
            },
            {
              "name": "CVE-2026-90689 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-90689"
            },
            {
              "name": "Submit #914981 | Tenda Router US_W20EV4.0br_V15.11.0.61068_1546_841_CN_TDC Memory Corruption",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/914981"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Amalll-Sec/router-vulnerability-research/blob/main/advisories/Tenda/W20E/formDelWebAuthWhiteUser/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-13T07:06:59.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E formDelWebAuthWhiteUser stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-90689",
        "datePublished": "2026-09-14T06:15:08.707Z",
        "dateReserved": "2026-09-13T05:01:50.679Z",
        "dateUpdated": "2026-09-14T10:55:57.386Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-90688 (GCVE-0-2026-90688)

    Vulnerability from nvd – Published: 2026-09-14 06:00 – Updated: 2026-09-15 15:57
    VLAI
    Title
    Tenda W20E HTTP formIPMacBindAdd stack-based overflow
    Summary
    A vulnerability was identified in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. This issue affects the function formIPMacBindAdd of the component HTTP Handler. Such manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to launch the attack remotely.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-15 15:57 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.61068_1546_841_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-90688",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-15T15:57:29.684776Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-15T15:57:34.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Amalll-Sec/router-vulnerability-research/blob/main/advisories/Tenda/W20E/formIPMacBindAdd/README.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "HTTP Handler"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.61068_1546_841_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "AmaIIl (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. This issue affects the function formIPMacBindAdd of the component HTTP Handler. Such manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to launch the attack remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:00:12.401Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-403221 | Tenda W20E HTTP formIPMacBindAdd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/403221"
            },
            {
              "name": "VDB-403221 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/403221/cti"
            },
            {
              "name": "CVE-2026-90688 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-90688"
            },
            {
              "name": "Submit #914958 | Tenda Router US_W20EV4.0br_V15.11.0.61068_1546_841_CN_TDC Memory Corruption",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/914958"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Amalll-Sec/router-vulnerability-research/blob/main/advisories/Tenda/W20E/formIPMacBindAdd/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-13T07:06:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E HTTP formIPMacBindAdd stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-90688",
        "datePublished": "2026-09-14T06:00:12.401Z",
        "dateReserved": "2026-09-13T05:01:47.157Z",
        "dateUpdated": "2026-09-15T15:57:34.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86300 (GCVE-0-2026-86300)

    Vulnerability from nvd – Published: 2026-09-07 11:30 – Updated: 2026-09-08 15:03
    VLAI
    Title
    Tenda AC9 Web Management R7WebsSecurityHandler improper authentication
    Summary
    A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 15:03 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86300",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T15:03:18.638512Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T15:03:32.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sleep (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-07T11:30:09.363Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399464 | Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399464"
            },
            {
              "name": "VDB-399464 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399464/cti"
            },
            {
              "name": "CVE-2026-86300 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86300"
            },
            {
              "name": "Submit #906606 | Tenda AC9 V15.03.05.14 Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906606"
            },
            {
              "name": "Submit #906607 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906607"
            },
            {
              "name": "Submit #906608 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906608"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_fast_setting_wifi_set_Unauth_Password.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-06T18:38:25.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86300",
        "datePublished": "2026-09-07T11:30:09.363Z",
        "dateReserved": "2026-09-06T16:33:21.215Z",
        "dateUpdated": "2026-09-08T15:03:32.769Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86167 (GCVE-0-2026-86167)

    Vulnerability from nvd – Published: 2026-09-06 04:30 – Updated: 2026-09-08 17:46
    VLAI
    Title
    Tenda HG10 Boa formgponConf os command injection
    Summary
    A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 17:45 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86167",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T17:45:51.458509Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T17:46:03.504Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T04:30:12.687Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399306 | Tenda HG10 Boa formgponConf os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399306"
            },
            {
              "name": "VDB-399306 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399306/cti"
            },
            {
              "name": "CVE-2026-86167 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86167"
            },
            {
              "name": "Submit #895596 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895596"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/command-formgponConf-fmgpon_loid.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T12:38:06.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa formgponConf os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86167",
        "datePublished": "2026-09-06T04:30:12.687Z",
        "dateReserved": "2026-09-05T10:32:11.111Z",
        "dateUpdated": "2026-09-08T17:46:03.504Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86166 (GCVE-0-2026-86166)

    Vulnerability from nvd – Published: 2026-09-06 04:00 – Updated: 2026-09-11 20:36
    VLAI
    Title
    Tenda HG10 Boa Web Server formWanRedirect buffer overflow
    Summary
    A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-11 20:15 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86166",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-11T20:15:48.470389Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-11T20:36:58.513Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T04:00:10.577Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399305 | Tenda HG10 Boa Web Server formWanRedirect buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399305"
            },
            {
              "name": "VDB-399305 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399305/cti"
            },
            {
              "name": "CVE-2026-86166 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86166"
            },
            {
              "name": "Submit #895595 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895595"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formWanRedirect-if.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T12:38:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Web Server formWanRedirect buffer overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86166",
        "datePublished": "2026-09-06T04:00:10.577Z",
        "dateReserved": "2026-09-05T10:32:03.953Z",
        "dateUpdated": "2026-09-11T20:36:58.513Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86165 (GCVE-0-2026-86165)

    Vulnerability from nvd – Published: 2026-09-06 03:30 – Updated: 2026-09-08 13:26
    VLAI
    Title
    Tenda HG10 formURL buffer overflow
    Summary
    A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 13:25 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86165",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T13:25:42.334376Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T13:26:12.197Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formURL-keywd.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T03:30:08.850Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399304 | Tenda HG10 formURL buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399304"
            },
            {
              "name": "VDB-399304 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399304/cti"
            },
            {
              "name": "CVE-2026-86165 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86165"
            },
            {
              "name": "Submit #895583 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895583"
            },
            {
              "name": "Submit #895594 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895594"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formURL-keywd.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T12:37:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 formURL buffer overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86165",
        "datePublished": "2026-09-06T03:30:08.850Z",
        "dateReserved": "2026-09-05T10:31:59.598Z",
        "dateUpdated": "2026-09-08T13:26:12.197Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86153 (GCVE-0-2026-86153)

    Vulnerability from nvd – Published: 2026-09-06 01:45 – Updated: 2026-09-08 17:13
    VLAI
    Title
    Tenda CP3 Redirect.cpp SetRedirectEnable privileges management
    Summary
    A vulnerability has been found in Tenda CP3 27.5.57.101. This affects the function CRedirServer::SetRedirectEnable of the file Functions/Redirect.cpp. The manipulation leads to improper privilege management. Remote exploitation of the attack is possible.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 17:09 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/399276 vdb-entrytechnical-description
    https://vuldb.com/vuln/399276/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-86153 third-party-advisory
    https://vuldb.com/submit/895354 third-party-advisory
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CP3 Affected: 27.5.57.101
        cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86153",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T17:09:30.443814Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T17:13:56.577Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CP3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "27.5.57.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "FengZi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB Vulnerability Moderation Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda CP3 27.5.57.101. This affects the function CRedirServer::SetRedirectEnable of the file Functions/Redirect.cpp. The manipulation leads to improper privilege management. Remote exploitation of the attack is possible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T01:45:15.067Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399276 | Tenda CP3 Redirect.cpp SetRedirectEnable privileges management",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399276"
            },
            {
              "name": "VDB-399276 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399276/cti"
            },
            {
              "name": "CVE-2026-86153 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86153"
            },
            {
              "name": "Submit #895354 | Tenda CP3 V3.2 V27.5.57.101 Improper Access Controls",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895354"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T09:45:59.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CP3 Redirect.cpp SetRedirectEnable privileges management",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86153",
        "datePublished": "2026-09-06T01:45:15.067Z",
        "dateReserved": "2026-09-05T07:40:34.443Z",
        "dateUpdated": "2026-09-08T17:13:56.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86152 (GCVE-0-2026-86152)

    Vulnerability from nvd – Published: 2026-09-06 01:30 – Updated: 2026-09-10 18:06
    VLAI
    Title
    Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection
    Summary
    A flaw has been found in Tenda CP3 27.5.57.101. The impacted element is the function CAutoAddWifi::ThreadProc of the file Functions/AutoAddWifi.cpp of the component Kylin. Executing a manipulation can lead to os command injection. The attack may be launched remotely.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 18:06 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/399275 vdb-entrytechnical-description
    https://vuldb.com/vuln/399275/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-86152 third-party-advisory
    https://vuldb.com/submit/895353 third-party-advisory
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CP3 Affected: 27.5.57.101
        cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86152",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T18:06:19.059653Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T18:06:27.153Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Kylin"
              ],
              "product": "CP3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "27.5.57.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "FengZi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB Vulnerability Moderation Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda CP3 27.5.57.101. The impacted element is the function CAutoAddWifi::ThreadProc of the file Functions/AutoAddWifi.cpp of the component Kylin. Executing a manipulation can lead to os command injection. The attack may be launched remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T01:30:10.981Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399275 | Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399275"
            },
            {
              "name": "VDB-399275 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399275/cti"
            },
            {
              "name": "CVE-2026-86152 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86152"
            },
            {
              "name": "Submit #895353 | Tenda CP3 V3.2 V27.5.57.101 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895353"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T09:45:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86152",
        "datePublished": "2026-09-06T01:30:10.981Z",
        "dateReserved": "2026-09-05T07:40:31.001Z",
        "dateUpdated": "2026-09-10T18:06:27.153Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115797 (GCVE-0-2026-115797)

    Vulnerability from cvelistv5 – Published: 2026-10-23 20:00 – Updated: 2026-10-23 20:00
    VLAI
    Title
    Tenda F6 Web Management cleartext transmission
    Summary
    A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks.
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    • CWE-310 - Cryptographic Issues
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 2.6,
                "vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-310",
                  "description": "Cryptographic Issues",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-23T20:00:16.370Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425975 | Tenda F6 Web Management cleartext transmission",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/425975"
            },
            {
              "name": "VDB-425975 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425975/cti"
            },
            {
              "name": "CVE-2026-115797 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115797"
            },
            {
              "name": "Submit #1022076 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cleartext Transmission of Sensitive Information (CWE-319)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022076"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/edit/main/02-Cleartext_Transmission.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-23T18:17:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cleartext transmission",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115797",
        "datePublished": "2026-10-23T20:00:16.370Z",
        "dateReserved": "2026-10-23T14:57:47.218Z",
        "dateUpdated": "2026-10-23T20:00:16.370Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-115796 (GCVE-0-2026-115796)

    Vulnerability from cvelistv5 – Published: 2026-10-23 19:45 – Updated: 2026-10-23 19:45
    VLAI
    Title
    Tenda F6 Web Management cross-site request forgery
    Summary
    A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.
    CWE
    • CWE-352 - Cross-Site Request Forgery
    • CWE-862 - Missing Authorization
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Tenda F6 Affected: 12.02.01.73
        cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:f6:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "F6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "12.02.01.73"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "WKZER (VulDB User)"
            },
            {
              "lang": "en",
              "type": "analyst",
              "value": "WKZER (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda F6 12.02.01.73. This impacts an unknown function of the component Web Management Interface. Performing a manipulation results in cross-site request forgery. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-23T19:45:19.860Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-425974 | Tenda F6 Web Management cross-site request forgery",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/425974"
            },
            {
              "name": "VDB-425974 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/425974/cti"
            },
            {
              "name": "CVE-2026-115796 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-115796"
            },
            {
              "name": "Submit #1022074 | Tenda F6 (N300) Wireless Router Firmware V12.02.01.73 (Hardware V5.0) Cross-Site Request Forgery (CWE-352)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1022074"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/0xWKZER/tenda-f6-vulnerabilities/blob/main/01-csrf.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-23T18:17:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda F6 Web Management cross-site request forgery",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-115796",
        "datePublished": "2026-10-23T19:45:19.860Z",
        "dateReserved": "2026-10-23T14:57:43.016Z",
        "dateUpdated": "2026-10-23T19:45:19.860Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-114268 (GCVE-0-2026-114268)

    Vulnerability from cvelistv5 – Published: 2026-10-21 18:45 – Updated: 2026-10-21 18:45
    VLAI
    Title
    Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow
    Summary
    A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/424700 vdb-entrytechnical-description
    https://vuldb.com/vuln/424700/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-114268 third-party-advisory
    https://vuldb.com/submit/1018994 third-party-advisory
    https://github.com/Tmzop/Tenda-CVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda BE3L Pro Affected: 16.03.60.62
        cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:be3l_pro:*:*:*:*:*:*:*:*"
              ],
              "product": "BE3L Pro",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.60.62"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "tmzhou (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda BE3L Pro 16.03.60.62. Affected by this vulnerability is the function formWifiBasicSet of the file /goform/WifiBasicSet. This manipulation of the argument security_5g causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T18:45:12.143Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-424700 | Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/424700"
            },
            {
              "name": "VDB-424700 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/424700/cti"
            },
            {
              "name": "CVE-2026-114268 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-114268"
            },
            {
              "name": "Submit #1018994 | Tenda Tenda Router BE3L Pro V16.03.60.62 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018994"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Tmzop/Tenda-CVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-21T09:01:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda BE3L Pro WifiBasicSet formWifiBasicSet buffer overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-114268",
        "datePublished": "2026-10-21T18:45:12.143Z",
        "dateReserved": "2026-10-21T06:51:52.604Z",
        "dateUpdated": "2026-10-21T18:45:12.143Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-113744 (GCVE-0-2026-113744)

    Vulnerability from cvelistv5 – Published: 2026-10-21 01:30 – Updated: 2026-10-21 01:30
    VLAI
    Title
    Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/422925 vdb-entrytechnical-description
    https://vuldb.com/vuln/422925/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-113744 third-party-advisory
    https://vuldb.com/submit/1018542 third-party-advisory
    https://github.com/henrythekingofuk/TendaCVE exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC19 Affected: 16.03.10.07
        cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:ac19:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "httpd Web Management Service"
              ],
              "product": "AC19",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.10.07"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Zeming Hu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T01:30:24.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-422925 | Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/422925"
            },
            {
              "name": "VDB-422925 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/422925/cti"
            },
            {
              "name": "CVE-2026-113744 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-113744"
            },
            {
              "name": "Submit #1018542 | Tenda AC19 V16.03.10.07 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1018542"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/henrythekingofuk/TendaCVE"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-20T18:58:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC19 httpd Web Management Service SetFirewallCfg formSetFirewallCfg stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-113744",
        "datePublished": "2026-10-21T01:30:24.075Z",
        "dateReserved": "2026-10-20T16:53:34.154Z",
        "dateUpdated": "2026-10-21T01:30:24.075Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-105778 (GCVE-0-2026-105778)

    Vulnerability from cvelistv5 – Published: 2026-10-06 06:45 – Updated: 2026-10-06 17:40
    VLAI
    Title
    Tenda AC5 Wifi setWifi stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-06 17:07 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda AC5 Affected: 02.03.01.111_multi
        cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-105778",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-06T17:07:05.050647Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-06T17:40:19.337Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac5_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Wifi Handler"
              ],
              "product": "AC5",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "02.03.01.111_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "raisecnull (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-06T06:45:13.774Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-413811 | Tenda AC5 Wifi setWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/413811"
            },
            {
              "name": "VDB-413811 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/413811/cti"
            },
            {
              "name": "CVE-2026-105778 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-105778"
            },
            {
              "name": "Submit #992587 | Tenda AC5 V02.03.01.111_multi Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/992587"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/raisecnull/Tenda-AC5v3-BOF/blob/main/blog.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-05T22:40:11.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC5 Wifi setWifi stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-105778",
        "datePublished": "2026-10-06T06:45:13.774Z",
        "dateReserved": "2026-10-05T20:34:57.881Z",
        "dateUpdated": "2026-10-06T17:40:19.337Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-104611 (GCVE-0-2026-104611)

    Vulnerability from cvelistv5 – Published: 2026-10-02 12:15 – Updated: 2026-10-02 13:30
    VLAI
    Title
    Tenda AC9 POST Request fast_setting_internet_set stack-based overflow
    Summary
    A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:30 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:30:30.834838Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:30:49.550Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "hodor (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:15:15.494Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412918 | Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412918"
            },
            {
              "name": "VDB-412918 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412918/cti"
            },
            {
              "name": "CVE-2026-104611 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104611"
            },
            {
              "name": "Submit #962720 | Tenda RouterOS AC9V1.0BR_V15.03.2.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962720"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/ZaneBoden/CVEs/blob/main/Tenda-AC9-fast_setting_internet_set.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:56:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request fast_setting_internet_set stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104611",
        "datePublished": "2026-10-02T12:15:15.494Z",
        "dateReserved": "2026-10-02T03:51:51.618Z",
        "dateUpdated": "2026-10-02T13:30:49.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-104610 (GCVE-0-2026-104610)

    Vulnerability from cvelistv5 – Published: 2026-10-02 12:00 – Updated: 2026-10-02 13:50
    VLAI
    Title
    Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:49 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/412917 vdb-entrytechnical-description
    https://vuldb.com/vuln/412917/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-104610 third-party-advisory
    https://vuldb.com/submit/962541 third-party-advisory
    https://github.com/Expl0rer-Ct/CVE/issues/1 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104610",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:49:47.985467Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:50:12.393Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Expl0rer.Ct (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:00:18.544Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412917 | Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412917"
            },
            {
              "name": "VDB-412917 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412917/cti"
            },
            {
              "name": "CVE-2026-104610 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104610"
            },
            {
              "name": "Submit #962541 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962541"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/Expl0rer-Ct/CVE/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:54:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104610",
        "datePublished": "2026-10-02T12:00:18.544Z",
        "dateReserved": "2026-10-02T03:49:26.992Z",
        "dateUpdated": "2026-10-02T13:50:12.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-90689 (GCVE-0-2026-90689)

    Vulnerability from cvelistv5 – Published: 2026-09-14 06:15 – Updated: 2026-09-14 10:55
    VLAI
    Title
    Tenda W20E formDelWebAuthWhiteUser stack-based overflow
    Summary
    A security flaw has been discovered in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. Impacted is the function formDelWebAuthWhiteUser. Performing a manipulation of the argument webAuthWhiteUserIndex results in stack-based buffer overflow. The attack can be initiated remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 10:54 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.61068_1546_841_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-90689",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T10:54:39.870335Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T10:55:57.386Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.61068_1546_841_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "AmaIIl (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. Impacted is the function formDelWebAuthWhiteUser. Performing a manipulation of the argument webAuthWhiteUserIndex results in stack-based buffer overflow. The attack can be initiated remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:15:08.707Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-403222 | Tenda W20E formDelWebAuthWhiteUser stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/403222"
            },
            {
              "name": "VDB-403222 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/403222/cti"
            },
            {
              "name": "CVE-2026-90689 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-90689"
            },
            {
              "name": "Submit #914981 | Tenda Router US_W20EV4.0br_V15.11.0.61068_1546_841_CN_TDC Memory Corruption",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/914981"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Amalll-Sec/router-vulnerability-research/blob/main/advisories/Tenda/W20E/formDelWebAuthWhiteUser/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-13T07:06:59.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E formDelWebAuthWhiteUser stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-90689",
        "datePublished": "2026-09-14T06:15:08.707Z",
        "dateReserved": "2026-09-13T05:01:50.679Z",
        "dateUpdated": "2026-09-14T10:55:57.386Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-90688 (GCVE-0-2026-90688)

    Vulnerability from cvelistv5 – Published: 2026-09-14 06:00 – Updated: 2026-09-15 15:57
    VLAI
    Title
    Tenda W20E HTTP formIPMacBindAdd stack-based overflow
    Summary
    A vulnerability was identified in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. This issue affects the function formIPMacBindAdd of the component HTTP Handler. Such manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to launch the attack remotely.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-15 15:57 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda W20E Affected: 15.11.0.61068_1546_841_CN_TDC
        cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-90688",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-15T15:57:29.684776Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-15T15:57:34.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Amalll-Sec/router-vulnerability-research/blob/main/advisories/Tenda/W20E/formIPMacBindAdd/README.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "HTTP Handler"
              ],
              "product": "W20E",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.11.0.61068_1546_841_CN_TDC"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "AmaIIl (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda W20E 15.11.0.61068_1546_841_CN_TDC. This issue affects the function formIPMacBindAdd of the component HTTP Handler. Such manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to launch the attack remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:00:12.401Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-403221 | Tenda W20E HTTP formIPMacBindAdd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/403221"
            },
            {
              "name": "VDB-403221 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/403221/cti"
            },
            {
              "name": "CVE-2026-90688 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-90688"
            },
            {
              "name": "Submit #914958 | Tenda Router US_W20EV4.0br_V15.11.0.61068_1546_841_CN_TDC Memory Corruption",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/914958"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/Amalll-Sec/router-vulnerability-research/blob/main/advisories/Tenda/W20E/formIPMacBindAdd/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-13T07:06:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda W20E HTTP formIPMacBindAdd stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-90688",
        "datePublished": "2026-09-14T06:00:12.401Z",
        "dateReserved": "2026-09-13T05:01:47.157Z",
        "dateUpdated": "2026-09-15T15:57:34.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86300 (GCVE-0-2026-86300)

    Vulnerability from cvelistv5 – Published: 2026-09-07 11:30 – Updated: 2026-09-08 15:03
    VLAI
    Title
    Tenda AC9 Web Management R7WebsSecurityHandler improper authentication
    Summary
    A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 15:03 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86300",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T15:03:18.638512Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T15:03:32.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sleep (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AC9 15.03.05.14. This impacts the function R7WebsSecurityHandler of the component Web Management. This manipulation causes improper authentication. The attack may be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-07T11:30:09.363Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399464 | Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399464"
            },
            {
              "name": "VDB-399464 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399464/cti"
            },
            {
              "name": "CVE-2026-86300 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86300"
            },
            {
              "name": "Submit #906606 | Tenda AC9 V15.03.05.14 Information Disclosure",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906606"
            },
            {
              "name": "Submit #906607 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906607"
            },
            {
              "name": "Submit #906608 | Tenda AC9 V15.03.05.14_multi / V15.03.05.16_multi Improper Access Controls (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906608"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_getProduct_Info_Disclosure.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Tenda_AC9_fast_setting_wifi_set_Unauth_Password.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-06T18:38:25.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Web Management R7WebsSecurityHandler improper authentication",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86300",
        "datePublished": "2026-09-07T11:30:09.363Z",
        "dateReserved": "2026-09-06T16:33:21.215Z",
        "dateUpdated": "2026-09-08T15:03:32.769Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86167 (GCVE-0-2026-86167)

    Vulnerability from cvelistv5 – Published: 2026-09-06 04:30 – Updated: 2026-09-08 17:46
    VLAI
    Title
    Tenda HG10 Boa formgponConf os command injection
    Summary
    A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 17:45 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86167",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T17:45:51.458509Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T17:46:03.504Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T04:30:12.687Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399306 | Tenda HG10 Boa formgponConf os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399306"
            },
            {
              "name": "VDB-399306 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399306/cti"
            },
            {
              "name": "CVE-2026-86167 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86167"
            },
            {
              "name": "Submit #895596 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895596"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/command-formgponConf-fmgpon_loid.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T12:38:06.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa formgponConf os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86167",
        "datePublished": "2026-09-06T04:30:12.687Z",
        "dateReserved": "2026-09-05T10:32:11.111Z",
        "dateUpdated": "2026-09-08T17:46:03.504Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86166 (GCVE-0-2026-86166)

    Vulnerability from cvelistv5 – Published: 2026-09-06 04:00 – Updated: 2026-09-11 20:36
    VLAI
    Title
    Tenda HG10 Boa Web Server formWanRedirect buffer overflow
    Summary
    A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-11 20:15 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86166",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-11T20:15:48.470389Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-11T20:36:58.513Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T04:00:10.577Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399305 | Tenda HG10 Boa Web Server formWanRedirect buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399305"
            },
            {
              "name": "VDB-399305 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399305/cti"
            },
            {
              "name": "CVE-2026-86166 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86166"
            },
            {
              "name": "Submit #895595 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895595"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formWanRedirect-if.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T12:38:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Web Server formWanRedirect buffer overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86166",
        "datePublished": "2026-09-06T04:00:10.577Z",
        "dateReserved": "2026-09-05T10:32:03.953Z",
        "dateUpdated": "2026-09-11T20:36:58.513Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86165 (GCVE-0-2026-86165)

    Vulnerability from cvelistv5 – Published: 2026-09-06 03:30 – Updated: 2026-09-08 13:26
    VLAI
    Title
    Tenda HG10 formURL buffer overflow
    Summary
    A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 13:25 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: 300001138
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86165",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T13:25:42.334376Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T13:26:12.197Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formURL-keywd.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sunnyyaya (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T03:30:08.850Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399304 | Tenda HG10 formURL buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399304"
            },
            {
              "name": "VDB-399304 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399304/cti"
            },
            {
              "name": "CVE-2026-86165 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86165"
            },
            {
              "name": "Submit #895583 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895583"
            },
            {
              "name": "Submit #895594 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895594"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/bof-formURL-keywd.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T12:37:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 formURL buffer overflow",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86165",
        "datePublished": "2026-09-06T03:30:08.850Z",
        "dateReserved": "2026-09-05T10:31:59.598Z",
        "dateUpdated": "2026-09-08T13:26:12.197Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86153 (GCVE-0-2026-86153)

    Vulnerability from cvelistv5 – Published: 2026-09-06 01:45 – Updated: 2026-09-08 17:13
    VLAI
    Title
    Tenda CP3 Redirect.cpp SetRedirectEnable privileges management
    Summary
    A vulnerability has been found in Tenda CP3 27.5.57.101. This affects the function CRedirServer::SetRedirectEnable of the file Functions/Redirect.cpp. The manipulation leads to improper privilege management. Remote exploitation of the attack is possible.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 17:09 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/399276 vdb-entrytechnical-description
    https://vuldb.com/vuln/399276/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-86153 third-party-advisory
    https://vuldb.com/submit/895354 third-party-advisory
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CP3 Affected: 27.5.57.101
        cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86153",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T17:09:30.443814Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T17:13:56.577Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "CP3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "27.5.57.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "FengZi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB Vulnerability Moderation Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda CP3 27.5.57.101. This affects the function CRedirServer::SetRedirectEnable of the file Functions/Redirect.cpp. The manipulation leads to improper privilege management. Remote exploitation of the attack is possible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T01:45:15.067Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399276 | Tenda CP3 Redirect.cpp SetRedirectEnable privileges management",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399276"
            },
            {
              "name": "VDB-399276 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399276/cti"
            },
            {
              "name": "CVE-2026-86153 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86153"
            },
            {
              "name": "Submit #895354 | Tenda CP3 V3.2 V27.5.57.101 Improper Access Controls",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895354"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T09:45:59.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CP3 Redirect.cpp SetRedirectEnable privileges management",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86153",
        "datePublished": "2026-09-06T01:45:15.067Z",
        "dateReserved": "2026-09-05T07:40:34.443Z",
        "dateUpdated": "2026-09-08T17:13:56.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86152 (GCVE-0-2026-86152)

    Vulnerability from cvelistv5 – Published: 2026-09-06 01:30 – Updated: 2026-09-10 18:06
    VLAI
    Title
    Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection
    Summary
    A flaw has been found in Tenda CP3 27.5.57.101. The impacted element is the function CAutoAddWifi::ThreadProc of the file Functions/AutoAddWifi.cpp of the component Kylin. Executing a manipulation can lead to os command injection. The attack may be launched remotely.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 18:06 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3814 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/vuln/399275 vdb-entrytechnical-description
    https://vuldb.com/vuln/399275/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-86152 third-party-advisory
    https://vuldb.com/submit/895353 third-party-advisory
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda CP3 Affected: 27.5.57.101
        cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86152",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T18:06:19.059653Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T18:06:27.153Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Kylin"
              ],
              "product": "CP3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "27.5.57.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "FengZi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB Vulnerability Moderation Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda CP3 27.5.57.101. The impacted element is the function CAutoAddWifi::ThreadProc of the file Functions/AutoAddWifi.cpp of the component Kylin. Executing a manipulation can lead to os command injection. The attack may be launched remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-06T01:30:10.981Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399275 | Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399275"
            },
            {
              "name": "VDB-399275 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399275/cti"
            },
            {
              "name": "CVE-2026-86152 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86152"
            },
            {
              "name": "Submit #895353 | Tenda CP3 V3.2 V27.5.57.101 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895353"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T09:45:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CP3 Kylin AutoAddWifi.cpp ThreadProc os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86152",
        "datePublished": "2026-09-06T01:30:10.981Z",
        "dateReserved": "2026-09-05T07:40:31.001Z",
        "dateUpdated": "2026-09-10T18:06:27.153Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }