VAR-202411-0572
Vulnerability from variot - Updated: 2024-11-16 22:57A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter wpapsk_crypto in the file /goform/WifiExtraSet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202411-0572",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac10",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac10",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac10 firmware 16.03.10.13"
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"cve": "CVE-2024-11056",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-11056",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-012643",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-44853",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-11056",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-012643",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-11056",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-11056",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-012643",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-44853",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC10 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter wpapsk_crypto in the file /goform/WifiExtraSet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-11056"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "CNVD",
"id": "CNVD-2024-44853"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-11056",
"trust": 3.2
},
{
"db": "VULDB",
"id": "283800",
"trust": 1.6
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-44853",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"id": "VAR-202411-0572",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
}
],
"trust": 0.86649562
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
}
]
},
"last_update_date": "2024-11-16T22:57:32.307000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC10 Buffer Overflow Vulnerability (CNVD-2024-44853)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/618211"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://tasty-foxtrot-3a8.notion.site/tenda-ac10v4-stack-overflow-1380448e619580409bb1e1ac85f45570"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.439358"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.6,
"url": "https://vuldb.com/?id.283800"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.283800"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-11056"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"date": "2024-11-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"date": "2024-11-10T17:15:15.697000",
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-44853"
},
{
"date": "2024-11-15T01:10:00",
"db": "JVNDB",
"id": "JVNDB-2024-012643"
},
{
"date": "2024-11-14T15:21:09.907000",
"db": "NVD",
"id": "CVE-2024-11056"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-012643"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.