Vulnerability from gsd - Updated: 2024-01-04 06:02Details
A memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
Aliases
{
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2024-21920"
],
"details": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n",
"id": "GSD-2024-21920",
"modified": "2024-01-04T06:02:16.298015Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@rockwellautomation.com",
"ID": "CVE-2024-21920",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Arena Simulation",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Version 16.00 - 16.20.02"
}
]
}
}
]
},
"vendor_name": "Rockwell Automation"
}
]
}
},
"credits": [
{
"lang": "en",
"value": "Michael Heinzl"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-125",
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html",
"refsource": "MISC",
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
}
]
},
"source": {
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted files from unknown sources.\u003c/li\u003e\u003cli\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability.\u003c/li\u003e\u003c/ul\u003e\n\n"
}
],
"value": "\n * Do not open untrusted files from unknown sources.\n * For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability.\n\n\n\n\n"
}
]
},
"nvd.nist.gov": {
"cve": {
"descriptions": [
{
"lang": "en",
"value": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n"
}
],
"id": "CVE-2024-21920",
"lastModified": "2024-03-26T17:09:53.043",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 2.5,
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
},
"published": "2024-03-26T16:15:11.277",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…