CVE-2024-21920 (GCVE-0-2024-21920)

Vulnerability from cvelistv5 – Published: 2024-03-26 15:48 – Updated: 2024-08-06 18:02
VLAI
Title
Rockwell Automation Arena Simulation Vulnerable To Buffer Overflow
Summary
A memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-06 18:02 UTC
CWE
Assigner
Rockwell CNA under the icscert root
CNA scorecard C 74/100 over 47 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Rockwell Automation Arena Simulation Affected: Version 16.00 - 16.20.02
guessed Create a notification for this product.
Date Public
2024-03-26 14:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-21920",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-06T18:02:20.851838Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-06T18:02:34.744Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena Simulation",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 16.00 - 16.20.02"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Michael Heinzl"
        }
      ],
      "datePublic": "2024-03-26T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T15:48:59.735Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rockwell Automation Arena Simulation Vulnerable To Buffer Overflow",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted files from unknown sources.\u003c/li\u003e\u003cli\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability.\u003c/li\u003e\u003c/ul\u003e\n\n"
            }
          ],
          "value": "\n  *  Do not open untrusted files from unknown sources.\n  *  For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested  security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability.\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-21920",
    "datePublished": "2024-03-26T15:48:59.735Z",
    "dateReserved": "2024-01-03T16:40:50.368Z",
    "dateUpdated": "2024-08-06T18:02:34.744Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-21920",
      "date": "2026-11-17",
      "epss": "0.0022",
      "percentile": "0.12572"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Arena Simulation",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "Version 16.00 - 16.20.02"
                  }
                ]
              }
            ],
            "source": "PSIRT@rockwellautomation.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:arena:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C8A71AA4-C01D-47F2-B87F-96EF9B461BD1",
                    "versionStartIncluding": "16.00.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n"
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad del b\u00fafer de memoria en Rockwell Automation Arena Simulation podr\u00eda permitir que un actor de amenazas lea m\u00e1s all\u00e1 de los l\u00edmites de memoria previstos. Esto podr\u00eda revelar informaci\u00f3n confidencial e incluso provocar que la aplicaci\u00f3n falle, lo que provocar\u00eda una condici\u00f3n de denegaci\u00f3n de servicio. Para desencadenar esto, el usuario tendr\u00eda que abrir, sin saberlo, un archivo malicioso compartido por el actor de la amenaza."
          }
        ],
        "id": "CVE-2024-21920",
        "lastModified": "2026-06-17T07:10:24.973",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 2.5,
              "source": "PSIRT@rockwellautomation.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.2,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-21920",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-06T18:02:20.851838Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-03-26T16:15:11.277",
        "references": [
          {
            "source": "PSIRT@rockwellautomation.com",
            "tags": [
              "Broken Link"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Broken Link"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
          }
        ],
        "sourceIdentifier": "PSIRT@rockwellautomation.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-125"
              }
            ],
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-125"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T21:30:59+00:00",
      "cve": "CVE-2024-21920",
      "id": "CVE-2024-21920",
      "initial_release_date": "2024-03-26T14:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Rockwell Automation Arena Simulation Vulnerable To Buffer Overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-21920.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T22:35:34.484Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-21920",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-06T18:02:20.851838Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-06T18:02:29.128Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Arena Simulation",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 16.00 - 16.20.02"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Michael Heinzl"
            }
          ],
          "datePublic": "2024-03-26T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nA memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T15:48:59.735Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Arena Simulation Vulnerable To Buffer Overflow",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted files from unknown sources.\u003c/li\u003e\u003cli\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability.\u003c/li\u003e\u003c/ul\u003e\n\n"
                }
              ],
              "value": "\n  *  Do not open untrusted files from unknown sources.\n  *  For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested  security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability.\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2024-21920",
        "datePublished": "2024-03-26T15:48:59.735Z",
        "dateReserved": "2024-01-03T16:40:50.368Z",
        "dateUpdated": "2024-08-06T18:02:34.744Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Workarounds

CNA · Rockwell
* Do not open untrusted files from unknown sources. * For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight  to minimize the risk of the vulnerability.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.