CVE-2026-3802 (GCVE-0-2026-3802)

Vulnerability from cvelistv5 – Published: 2026-03-09 04:32 – Updated: 2026-03-10 15:50
VLAI
Title
Tenda i3 exeCommand formexeCommand stack-based overflow
Summary
A vulnerability was determined in Tenda i3 1.0.0.6(2204). Affected by this issue is the function formexeCommand of the file /goform/exeCommand. Executing a manipulation of the argument cmdinput can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-03-10 15:50 UTC
CWE
Assigner
VulDB CNA under the mitre root
CNA scorecard B 82/100 over 3882 records in the last 180 days details
References
URL Tags
https://vuldb.com/?id.349769 vdb-entrytechnical-description
https://vuldb.com/?ctiid.349769 signaturepermissions-required
https://vuldb.com/?submit.768983 third-party-advisory
https://github.com/Svigo-o/Tenda_vul/tree/main/te… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version CPE status
Tenda i3 Affected: 1.0.0.6(2204)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-3802",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T15:50:36.819601Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T15:50:45.837Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "i3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.6(2204)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Svigo (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda i3 1.0.0.6(2204). Affected by this issue is the function formexeCommand of the file /goform/exeCommand. Executing a manipulation of the argument cmdinput can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-09T04:32:09.989Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-349769 | Tenda i3 exeCommand formexeCommand stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.349769"
        },
        {
          "name": "VDB-349769 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.349769"
        },
        {
          "name": "Submit #768983 | Tenda i3 V1.0.0.6(2204) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.768983"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-i3-formexeCommand-cmdinput-buffer-overflow"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-03-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-03-08T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-03-08T13:44:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda i3 exeCommand formexeCommand stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-3802",
    "datePublished": "2026-03-09T04:32:09.989Z",
    "dateReserved": "2026-03-08T12:39:31.711Z",
    "dateUpdated": "2026-03-10T15:50:45.837Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-3802",
      "date": "2026-10-15",
      "epss": "0.01048",
      "percentile": "0.63549"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "i3",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.6(2204)"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:i3_firmware:1.0.0.6\\(2204\\):*:*:*:*:*:*:*",
                    "matchCriteriaId": "70DC8153-3B2F-4369-B01A-DF0C4804AFA5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:i3:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "50D0C1A4-AA5F-426A-B82C-00D1CEFE20FC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was determined in Tenda i3 1.0.0.6(2204). Affected by this issue is the function formexeCommand of the file /goform/exeCommand. Executing a manipulation of the argument cmdinput can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad fue determinada en Tenda i3 1.0.0.6(2204). Afectada por este problema es la funci\u00f3n formexeCommand del archivo /goform/exeCommand. La ejecuci\u00f3n de una manipulaci\u00f3n del argumento cmdinput puede llevar a desbordamiento de b\u00fafer basado en pila. El ataque puede ser realizado desde remoto. El exploit ha sido divulgado p\u00fablicamente y puede ser utilizado."
          }
        ],
        "id": "CVE-2026-3802",
        "lastModified": "2026-06-17T10:44:15.410",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-3802",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T15:50:36.819601Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-03-09T05:15:48.403",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-i3-formexeCommand-cmdinput-buffer-overflow"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?ctiid.349769"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?id.349769"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?submit.768983"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Product"
            ],
            "url": "https://www.tenda.com.cn/"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              },
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T07:35:06+00:00",
      "cve": "CVE-2026-3802",
      "id": "CVE-2026-3802",
      "initial_release_date": "2026-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Tenda i3 exeCommand formexeCommand stack-based overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-3802.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3802",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T15:50:36.819601Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T15:50:41.301Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.6(2204)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Svigo (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda i3 1.0.0.6(2204). Affected by this issue is the function formexeCommand of the file /goform/exeCommand. Executing a manipulation of the argument cmdinput can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-09T04:32:09.989Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-349769 | Tenda i3 exeCommand formexeCommand stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.349769"
            },
            {
              "name": "VDB-349769 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.349769"
            },
            {
              "name": "Submit #768983 | Tenda i3 V1.0.0.6(2204) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.768983"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-i3-formexeCommand-cmdinput-buffer-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-08T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-08T13:44:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i3 exeCommand formexeCommand stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-3802",
        "datePublished": "2026-03-09T04:32:09.989Z",
        "dateReserved": "2026-03-08T12:39:31.711Z",
        "dateUpdated": "2026-03-10T15:50:45.837Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.