CVE-2023-3595 (GCVE-0-2023-3595)
Vulnerability from cvelistv5 – Published: 2023-07-12 12:37 – Updated: 2024-08-02 07:01- CWE-787 - Out-of-bounds Write
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.031Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TK Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TP Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPXT Series A",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
}
],
"datePublic": "2023-07-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\u003c/span\u003e\n\n"
}
],
"value": "\nWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-12T13:15:20.247Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eUpdate firmware.\u003c/strong\u003e\u0026nbsp;Update EN2* ControlLogix communications modules to mitigated firmware.\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eProperly segment networks.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eImplement detection signatures.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e\n\n"
}
],
"value": "\n * Update firmware.\u00a0Update EN2* ControlLogix communications modules to mitigated firmware.\n * Properly segment networks.\u00a0Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\n * Implement detection signatures.\u00a0Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-3595",
"datePublished": "2023-07-12T12:37:01.939Z",
"dateReserved": "2023-07-10T15:34:52.031Z",
"dateUpdated": "2024-08-02T07:01:57.031Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-3595",
"date": "2026-11-16",
"epss": "0.05526",
"percentile": "0.92942"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TK Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TP Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPXT Series A",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D4B3185-B776-46C4-B47F-CE48861A422B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2f_series_a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97AC710F-97B3-47A1-86EC-3148A21F16B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7242493E-0B2A-4AF3-BF44-15D3D1DB0021",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2f_series_b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FA49358A-F76E-4DEC-994C-B988DE38BF7F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "48F83304-EF89-48A4-AA0E-EBD5AE5E46E5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2f_series_c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C6E5B08F-BD0C-4B3F-9897-61C945981CC6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8E9CEA5-F039-484D-A234-1E3ADA352E32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BBB6A3C1-6419-4CDB-B7F5-57F20DA43C5A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ADCF431D-0F13-4037-BBDF-4199B5860CCA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9D2541-B0DB-4925-ACD6-FCC2A028FA4A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E9B8DEC1-3980-49E0-82B1-275FD7870EC9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "13581B79-89FF-42F0-93C1-CB77582E7303",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "88F147B7-96D5-4C52-AE8C-C5A24A103290",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2t_series_d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F71090C1-36AD-4A1B-92B5-CB391593DF4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "94271569-D658-4F95-B9A6-2C1DB2647EB2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2tr_series_a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A4A8E21A-3826-497C-9F3D-6D9091AD7647",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BAEF2D94-6224-4877-9169-E5B0DB3FAA25",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2tr_series_b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8607CD0D-0EE7-41CF-8E00-C0F5C83646A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EAB58AD4-EA1F-4106-ADD1-52EF2592B92C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en2tr_series_c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D58BA41B-3859-4489-9C74-730C27B1EFF0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE90B141-E680-4D15-8BCE-8D58909A3679",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en3tr_series_a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4824C266-82B1-4B74-AF72-BFCEF0547023",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "01816E19-DF07-4A48-BC59-4A9918AE94FA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en3tr_series_b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14CF3A11-7130-420A-B99E-8FADA7C23484",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\n\n"
}
],
"id": "CVE-2023-3595",
"lastModified": "2026-06-17T06:14:25.593",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-07-12T13:15:09.880",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T00:44:12+00:00",
"cve": "CVE-2023-3595",
"id": "CVE-2023-3595",
"initial_release_date": "2023-07-12T12:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-3595.json",
"version": "3"
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.