CVE-2026-8312 (GCVE-0-2026-8312)
Vulnerability from nvd – Published: 2026-07-14 12:43 – Updated: 2026-07-14 13:27
VLAI
EPSS
VEX
Title
Rockwell Automation Arena® - Memory Corruption Vulnerability
Summary
A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-14 13:27 UTC
CWE
- CWE-787 - Out-of-bounds write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Auotmation | Arena® Simulation |
Affected:
V17.00.00 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8312",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T13:27:44.823243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T13:27:53.655Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Arena\u00ae Simulation",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "V17.00.00 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security issue exists within Arena\u00ae Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file."
}
],
"value": "A security issue exists within Arena\u00ae Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:43:09.839Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1784.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to\u0026nbsp;\u0026nbsp;V17.00.01 or later"
}
],
"value": "Upgrade to\u00a0\u00a0V17.00.01 or later"
}
],
"source": {
"advisory": "SD1784",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation Arena\u00ae - Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2026-8312",
"datePublished": "2026-07-14T12:43:09.839Z",
"dateReserved": "2026-05-11T12:39:37.355Z",
"dateUpdated": "2026-07-14T13:27:53.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-10577 (GCVE-0-2026-10577)
Vulnerability from nvd – Published: 2026-07-14 12:52 – Updated: 2026-07-14 13:19
VLAI
EPSS
VEX
Title
Rockwell Automation 1715 Redundant IO – Access Control Vulnerability
Summary
A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-14 13:19 UTC
CWE
- CWE-306 - Missing authentication for critical function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Auotmation | 1715 EtherNet/IP Communications Module |
Affected:
3.003 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-10577",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T13:19:42.350747Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T13:19:49.516Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1715 EtherNet/IP Communications Module",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "3.003 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device."
}
],
"value": "A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing authentication for critical function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:52:40.986Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to\u0026nbsp;\n3.011 or later"
}
],
"value": "Upgrade to\u00a0\n3.011 or later"
}
],
"source": {
"advisory": "SD1785",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation 1715 Redundant IO \u2013 Access Control Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2026-10577",
"datePublished": "2026-07-14T12:52:40.986Z",
"dateReserved": "2026-06-01T17:15:25.549Z",
"dateUpdated": "2026-07-14T13:19:49.516Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-2262 (GCVE-0-2023-2262)
Vulnerability from nvd – Published: 2023-09-20 15:20 – Updated: 2024-09-25 15:44
VLAI
EPSS
VEX
Title
Rockwell Automation Select Logix Communication Modules Vulnerable to Email Object Buffer Overflow
Summary
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-25 14:39 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
23 products
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | 1756-EN2T Series A, B, C |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2T Series D |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TK Series A, B, C |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TXT Series A, B, C |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TXT Series D |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TP Series A |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TPK Series A |
Affected:
<=11.002
|
|
| Rockwell Auotmation | 1756-EN2TPXT Series A |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TR Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TR Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TRK Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TRK Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TRXT Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TRXT Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2F Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2F Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2FK Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2FK Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN3TR Series A |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN3TR Series B |
Affected:
<=11.003
|
|
| Rockwell Automation | 1756-EN3TRK Series A |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN3TRK Series B |
Affected:
<=11.002
|
|
| rockwellautomation | 1756-en2fk_series_c_firmware |
Affected:
5.008 , ≤ 5.028
(custom)
Affected: 0 , ≤ 11.0002 (custom) cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tk_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tp_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tpk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trk_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trxt_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trxt_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trxt_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2fk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2fk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2fk_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3trk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3trk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tpxt_series_a_firmware:*:*:*:*:*:*:*:* |
Date Public
2023-09-12 12:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:19:14.686Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140786"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tk_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_d_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tp_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tpk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trk_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trxt_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trxt_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trxt_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2fk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2fk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2fk_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3trk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3trk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tpxt_series_a_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "1756-en2fk_series_c_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.028",
"status": "affected",
"version": "5.008",
"versionType": "custom"
},
{
"lessThanOrEqual": "11.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2262",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T14:39:20.985093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T15:44:30.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TK Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TP Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPXT Series A",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
}
],
"datePublic": "2023-09-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
}
],
"value": "\n\n\nA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-20T15:47:00.968Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140786"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eUpdate firmware.\u003c/strong\u003e\u0026nbsp;Update EN2* ControlLogix communications modules to mitigated firmware.\u003cbr\u003e\u003cul\u003e\u003cli\u003eRestrict traffic to the SMTP port (25), if not needed.\u003c/li\u003e\u003cli\u003eCustomers using the EN2/EN3 versions 10.x and higher can disable the email object, if not needed. Instructions can be found in the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/um/enet-um006_-en-p.pdf\"\u003eEtherNet/IP Network Devices User Manual (rockwellautomation.com)\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e, publication ENET-UM006.\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n"
}
],
"value": "Update firmware.\u00a0Update EN2* ControlLogix communications modules to mitigated firmware.\n * Restrict traffic to the SMTP port (25), if not needed.\n * Customers using the EN2/EN3 versions 10.x and higher can disable the email object, if not needed. Instructions can be found in the EtherNet/IP Network Devices User Manual (rockwellautomation.com) https://literature.rockwellautomation.com/idc/groups/literature/documents/um/enet-um006_-en-p.pdf , publication ENET-UM006.\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation Select Logix Communication Modules Vulnerable to Email Object Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-2262",
"datePublished": "2023-09-20T15:20:23.700Z",
"dateReserved": "2023-04-24T21:35:54.200Z",
"dateUpdated": "2024-09-25T15:44:30.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3595 (GCVE-0-2023-3595)
Vulnerability from nvd – Published: 2023-07-12 12:37 – Updated: 2024-08-02 07:01
VLAI
EPSS
VEX
Title
Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution
Summary
Where this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.
Severity
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
22 products
Date Public
2023-07-12 12:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.031Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TK Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TP Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPXT Series A",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
}
],
"datePublic": "2023-07-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\u003c/span\u003e\n\n"
}
],
"value": "\nWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-12T13:15:20.247Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eUpdate firmware.\u003c/strong\u003e\u0026nbsp;Update EN2* ControlLogix communications modules to mitigated firmware.\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eProperly segment networks.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eImplement detection signatures.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e\n\n"
}
],
"value": "\n * Update firmware.\u00a0Update EN2* ControlLogix communications modules to mitigated firmware.\n * Properly segment networks.\u00a0Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\n * Implement detection signatures.\u00a0Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-3595",
"datePublished": "2023-07-12T12:37:01.939Z",
"dateReserved": "2023-07-10T15:34:52.031Z",
"dateUpdated": "2024-08-02T07:01:57.031Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-10577 (GCVE-0-2026-10577)
Vulnerability from cvelistv5 – Published: 2026-07-14 12:52 – Updated: 2026-07-14 13:19
VLAI
EPSS
VEX
Title
Rockwell Automation 1715 Redundant IO – Access Control Vulnerability
Summary
A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-14 13:19 UTC
CWE
- CWE-306 - Missing authentication for critical function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Auotmation | 1715 EtherNet/IP Communications Module |
Affected:
3.003 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-10577",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T13:19:42.350747Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T13:19:49.516Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1715 EtherNet/IP Communications Module",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "3.003 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device."
}
],
"value": "A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing authentication for critical function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:52:40.986Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to\u0026nbsp;\n3.011 or later"
}
],
"value": "Upgrade to\u00a0\n3.011 or later"
}
],
"source": {
"advisory": "SD1785",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation 1715 Redundant IO \u2013 Access Control Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2026-10577",
"datePublished": "2026-07-14T12:52:40.986Z",
"dateReserved": "2026-06-01T17:15:25.549Z",
"dateUpdated": "2026-07-14T13:19:49.516Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8312 (GCVE-0-2026-8312)
Vulnerability from cvelistv5 – Published: 2026-07-14 12:43 – Updated: 2026-07-14 13:27
VLAI
EPSS
VEX
Title
Rockwell Automation Arena® - Memory Corruption Vulnerability
Summary
A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-14 13:27 UTC
CWE
- CWE-787 - Out-of-bounds write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Auotmation | Arena® Simulation |
Affected:
V17.00.00 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8312",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T13:27:44.823243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T13:27:53.655Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Arena\u00ae Simulation",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "V17.00.00 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security issue exists within Arena\u00ae Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file."
}
],
"value": "A security issue exists within Arena\u00ae Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:43:09.839Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1784.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to\u0026nbsp;\u0026nbsp;V17.00.01 or later"
}
],
"value": "Upgrade to\u00a0\u00a0V17.00.01 or later"
}
],
"source": {
"advisory": "SD1784",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation Arena\u00ae - Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2026-8312",
"datePublished": "2026-07-14T12:43:09.839Z",
"dateReserved": "2026-05-11T12:39:37.355Z",
"dateUpdated": "2026-07-14T13:27:53.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-2262 (GCVE-0-2023-2262)
Vulnerability from cvelistv5 – Published: 2023-09-20 15:20 – Updated: 2024-09-25 15:44
VLAI
EPSS
VEX
Title
Rockwell Automation Select Logix Communication Modules Vulnerable to Email Object Buffer Overflow
Summary
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-25 14:39 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
23 products
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | 1756-EN2T Series A, B, C |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2T Series D |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TK Series A, B, C |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TXT Series A, B, C |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TXT Series D |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TP Series A |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TPK Series A |
Affected:
<=11.002
|
|
| Rockwell Auotmation | 1756-EN2TPXT Series A |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TR Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TR Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TRK Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TRK Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2TRXT Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2TRXT Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2F Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2F Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN2FK Series A, B |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN2FK Series C |
Affected:
<=11.002
|
|
| Rockwell Automation | 1756-EN3TR Series A |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN3TR Series B |
Affected:
<=11.003
|
|
| Rockwell Automation | 1756-EN3TRK Series A |
Affected:
<=5.008 & 5.028
|
|
| Rockwell Automation | 1756-EN3TRK Series B |
Affected:
<=11.002
|
|
| rockwellautomation | 1756-en2fk_series_c_firmware |
Affected:
5.008 , ≤ 5.028
(custom)
Affected: 0 , ≤ 11.0002 (custom) cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tk_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2txt_series_d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tp_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tpk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trk_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trxt_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trxt_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2trxt_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2fk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2fk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2fk_series_c_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3trk_series_a_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en3trk_series_b_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:rockwellautomation:1756-en2tpxt_series_a_firmware:*:*:*:*:*:*:*:* |
Date Public
2023-09-12 12:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:19:14.686Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140786"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tk_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2txt_series_d_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tp_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tpk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trk_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trxt_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trxt_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2trxt_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2fk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2fk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2fk_series_c_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3trk_series_a_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en3trk_series_b_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:rockwellautomation:1756-en2tpxt_series_a_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "1756-en2fk_series_c_firmware",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.028",
"status": "affected",
"version": "5.008",
"versionType": "custom"
},
{
"lessThanOrEqual": "11.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2262",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T14:39:20.985093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T15:44:30.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TK Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TP Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPXT Series A",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.002"
}
]
}
],
"datePublic": "2023-09-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
}
],
"value": "\n\n\nA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-20T15:47:00.968Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140786"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eUpdate firmware.\u003c/strong\u003e\u0026nbsp;Update EN2* ControlLogix communications modules to mitigated firmware.\u003cbr\u003e\u003cul\u003e\u003cli\u003eRestrict traffic to the SMTP port (25), if not needed.\u003c/li\u003e\u003cli\u003eCustomers using the EN2/EN3 versions 10.x and higher can disable the email object, if not needed. Instructions can be found in the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/um/enet-um006_-en-p.pdf\"\u003eEtherNet/IP Network Devices User Manual (rockwellautomation.com)\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e, publication ENET-UM006.\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n"
}
],
"value": "Update firmware.\u00a0Update EN2* ControlLogix communications modules to mitigated firmware.\n * Restrict traffic to the SMTP port (25), if not needed.\n * Customers using the EN2/EN3 versions 10.x and higher can disable the email object, if not needed. Instructions can be found in the EtherNet/IP Network Devices User Manual (rockwellautomation.com) https://literature.rockwellautomation.com/idc/groups/literature/documents/um/enet-um006_-en-p.pdf , publication ENET-UM006.\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation Select Logix Communication Modules Vulnerable to Email Object Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-2262",
"datePublished": "2023-09-20T15:20:23.700Z",
"dateReserved": "2023-04-24T21:35:54.200Z",
"dateUpdated": "2024-09-25T15:44:30.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3595 (GCVE-0-2023-3595)
Vulnerability from cvelistv5 – Published: 2023-07-12 12:37 – Updated: 2024-08-02 07:01
VLAI
EPSS
VEX
Title
Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution
Summary
Where this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.
Severity
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
22 products
Date Public
2023-07-12 12:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.031Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2T Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TK Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series A, B, C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TXT Series D",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TP Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TPXT Series A",
"vendor": "Rockwell Auotmation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TR Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2TRXT Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2F Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series A, B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN2FK Series C",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TR Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.008 \u0026 5.028"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN3TRK Series B",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=11.003"
}
]
}
],
"datePublic": "2023-07-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\u003c/span\u003e\n\n"
}
],
"value": "\nWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-12T13:15:20.247Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eUpdate firmware.\u003c/strong\u003e\u0026nbsp;Update EN2* ControlLogix communications modules to mitigated firmware.\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eProperly segment networks.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eImplement detection signatures.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e\n\n"
}
],
"value": "\n * Update firmware.\u00a0Update EN2* ControlLogix communications modules to mitigated firmware.\n * Properly segment networks.\u00a0Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\n * Implement detection signatures.\u00a0Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-3595",
"datePublished": "2023-07-12T12:37:01.939Z",
"dateReserved": "2023-07-10T15:34:52.031Z",
"dateUpdated": "2024-08-02T07:01:57.031Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}