CVE-2018-3657 (GCVE-0-2018-3657)

Vulnerability from cvelistv5 – Published: 2018-09-12 19:00 – Updated: 2024-09-16 20:01
VLAI
Summary
Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access.
CWE
  • Denial of Service, Information Disclosure
Assigner
intel CNA under the mitre root
CNA scorecard C 60/100 over 96 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Intel Corporation Intel(R) Active Management Technology Affected: Versions before version 12.0.5.
guessed Create a notification for this product.
Date Public
2018-09-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T04:50:30.304Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
          },
          {
            "name": "106996",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106996"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) Active Management Technology",
          "vendor": "Intel Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Versions before version 12.0.5."
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial of Service, Information Disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-25T22:57:01.000Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
        },
        {
          "name": "106996",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106996"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-3657",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) Active Management Technology",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions before version 12.0.5."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Intel Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial of Service, Information Disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
            },
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html",
              "refsource": "CONFIRM",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
            },
            {
              "name": "106996",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106996"
            },
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20180924-0003/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2018-3657",
    "datePublished": "2018-09-12T19:00:00.000Z",
    "dateReserved": "2017-12-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:01:21.908Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-3657",
      "date": "2026-10-21",
      "epss": "0.0059",
      "percentile": "0.47477"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "503E551C-FC5F-4ABC-8DEA-E360701F0B33",
                    "versionEndExcluding": "22.01.06",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "33F546AF-8F80-4E0A-9B92-86E3A1F931C0",
                    "versionEndExcluding": "21.01.09",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B5B6E6B-16A0-4236-AABE-82385B53EC78",
                    "versionEndExcluding": "21.01.09",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc547e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D476D093-4A97-499C-B40D-7A301BC9AA2E",
                    "versionEndExcluding": "r1.30.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_pc547e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F6A757F1-E478-4A3D-8D5F-C996E176A11A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_pc547g_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "30F129DB-51AC-4F40-A0D1-AB5CF90D9C2D",
                    "versionEndExcluding": "r1.23.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9EB339B5-602F-4AB5-9998-465FDC6ABD6C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "790D244A-AC3D-4BBC-9139-A90048FD375A",
                    "versionEndExcluding": "19.02.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc627d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "509AD120-3465-4C00-AAB3-B6F6ED708B51",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0C046182-BB33-41D0-B041-1566B8041917",
                    "versionEndExcluding": "19.01.14",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D0EF28FB-BAB3-4710-9D25-25F67ACADC60",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8DE74300-E061-452E-AD1D-6DD7C2C62729",
                    "versionEndExcluding": "19.02.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc677d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "057D9947-CE4A-4B4C-B721-4B29FB71350C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc827d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BE4A7C13-6F81-4629-9C28-9202028634AE",
                    "versionEndExcluding": "19.02.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc827d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E6D87239-40C1-4038-B734-D77AC4DDD571",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "93485235-481B-4BAF-BB7A-81BB5AA1BC53",
                    "versionEndExcluding": "19.01.14",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D8F37D88-E086-4060-8420-BD0F8D8FF580",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AD949046-46E5-48C9-883B-92F04926E8BC",
                    "versionEndExcluding": "23.01.04",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C23AFAB4-B286-4FD6-ABC3-86B2881E271C",
                    "versionEndExcluding": "12.0.5",
                    "versionStartIncluding": "11.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:intel:active_management_technology_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D5FAD938-027A-406F-9E7C-1BFD992839F4",
                    "versionEndExcluding": "12.0.5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:intel:manageability_engine_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "63591E72-6038-4417-BA10-54180507AF0F",
                    "versionEndExcluding": "11.0",
                    "versionStartIncluding": "9.0.0.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access."
          },
          {
            "lang": "es",
            "value": "M\u00faltiples desbordamientos de b\u00fafer en Intel AMT en el firmware Intel CSME en versiones anteriores a la 12.0.5 podr\u00edan permitir que un usuario privilegiado ejecute c\u00f3digo arbitrario con privilegios de ejecuci\u00f3n AMT mediante acceso local."
          }
        ],
        "id": "CVE-2018-3657",
        "lastModified": "2024-11-21T04:05:50.857",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 0.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-09-12T19:29:02.840",
        "references": [
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/106996"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/106996"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
          }
        ],
        "sourceIdentifier": "secure@intel.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.