CVE-2026-54429 (GCVE-0-2026-54429)
Vulnerability from cvelistv5 – Published: 2026-07-14 09:19 – Updated: 2026-07-14 12:15- CWE-770 - Allocation of Resources Without Limits or Throttling
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SIMATIC S7-PLCSIM Advanced |
Affected:
0 , < *
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54429",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T12:15:03.571205Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:15:38.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T09:19:17.249Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-828211.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-54429",
"datePublished": "2026-07-14T09:19:17.249Z",
"dateReserved": "2026-06-15T10:05:28.879Z",
"dateUpdated": "2026-07-14T12:15:38.712Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-54429",
"date": "2026-11-26",
"epss": "0.00265",
"percentile": "0.11444"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en SIMATIC S7-PLCSIM Advanced (Todas las versiones). Los dispositivos afectados no manejan adecuadamente el tr\u00e1fico de red multicast de alto volumen, lo que puede agotar los recursos de memoria disponibles en la aplicaci\u00f3n afectada. Esto podr\u00eda permitir a un atacante no autenticado en el segmento de red local causar una condici\u00f3n de denegaci\u00f3n de servicio de la aplicaci\u00f3n afectada. La aplicaci\u00f3n afectada se vuelve inaccesible y requiere un reinicio manual; no se pierden datos del proyecto. La explotaci\u00f3n exitosa requiere que una configuraci\u00f3n de proyecto espec\u00edfica ya est\u00e9 activa en la instancia objetivo."
}
],
"id": "CVE-2026-54429",
"lastModified": "2026-10-24T21:10:00.130",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.0,
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-54429",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T12:15:03.571205Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-07-14T10:16:33.123",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-828211.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54429",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T12:15:03.571205Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:15:24.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T09:19:17.249Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-828211.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-54429",
"datePublished": "2026-07-14T09:19:17.249Z",
"dateReserved": "2026-06-15T10:05:28.879Z",
"dateUpdated": "2026-07-14T12:15:38.712Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.