SSA-828211

Vulnerability from csaf_siemens - Published: 2026-07-14 00:00 - Updated: 2026-07-14 00:00
Summary
SSA-828211: Denial of Service Vulnerability in SIMATIC S7-PLCSIM Advanced
Notes
Summary: SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.

CWE-770 - Allocation of Resources Without Limits or Throttling
Affected products
Product Identifier Version Remediation
SIMATIC S7-PLCSIM Advanced
Siemens / SIMATIC S7-PLCSIM Advanced
vers:all/*
Mitigation
Mitigation
Mitigation
None Available

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition.\n\nSiemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-828211: Denial of Service Vulnerability in SIMATIC S7-PLCSIM Advanced - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-828211.html"
      },
      {
        "category": "self",
        "summary": "SSA-828211: Denial of Service Vulnerability in SIMATIC S7-PLCSIM Advanced - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-828211.json"
      }
    ],
    "title": "SSA-828211: Denial of Service Vulnerability in SIMATIC S7-PLCSIM Advanced",
    "tracking": {
      "current_release_date": "2026-07-14T00:00:00.000Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-828211",
      "initial_release_date": "2026-07-14T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-07-14T00:00:00.000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC S7-PLCSIM Advanced",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC S7-PLCSIM Advanced"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2026-54429",
      "cwe": {
        "id": "CWE-770",
        "name": "Allocation of Resources Without Limits or Throttling"
      },
      "notes": [
        {
          "category": "description",
          "text": "Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Disable the S7-PLCSIM Virtual Switch binding on the network adapter used by the affected instance. This prevents the adapter from entering an external communication mode and removes the attack vector entirely. (see SIMATIC S7-PLCSIM Advanced Function Manual V8.0, 11/2025 Section 5.3 and Section 6.1.2.3; and SIMATIC S7-PLCSIM Advanced Function Manual API V8.0, 11/2025 Section 7.2)",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "mitigation",
          "details": "Restrict multicast traffic on the network segment hosting the SIMATIC S7-PLCSIM Advanced host.",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "mitigation",
          "details": "Use \u0027Softbus\u0027 / \u0027PLCSIM\u0027 network mode. This mode does not accept any packets from the network. This mode is a default network mode. (see SIMATIC S7-PLCSIM Advanced Function Manual V8.0, 11/2025 Section 5.0 and Section 5.1; and SIMATIC S7-PLCSIM Advanced Function Manual API V8.0, 11/2025 Section 7.2)",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "1"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2026-54429"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…