CVE-2026-13580 (GCVE-0-2026-13580)

Vulnerability from cvelistv5 – Published: 2026-06-29 15:00 – Updated: 2026-06-29 16:19
VLAI
Title
Edimax EW-7478APC POST Request formQoS buffer overflow
Summary
A security vulnerability has been detected in Edimax EW-7478APC 1.04. This affects the function formQoS of the file /goform/formQoS of the component POST Request Handler. The manipulation of the argument selSSID leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/374586 vdb-entrytechnical-description
https://vuldb.com/vuln/374586/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-13580 third-party-advisory
https://vuldb.com/submit/844115 third-party-advisory
https://lavender-bicycle-a5a.notion.site/EDIMAX-E… broken-linkexploit
Impacted products
Vendor Product Version
Edimax EW-7478APC Affected: 1.04
    cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User) VulDB CNA Team
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-13580",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-29T16:19:43.559040Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-29T16:19:48.827Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "POST Request Handler"
          ],
          "product": "EW-7478APC",
          "vendor": "Edimax",
          "versions": [
            {
              "status": "affected",
              "version": "1.04"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "VulDB CNA Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Edimax EW-7478APC 1.04. This affects the function formQoS of the file /goform/formQoS of the component POST Request Handler. The manipulation of the argument selSSID leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-29T15:00:18.232Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-374586 | Edimax EW-7478APC POST Request formQoS buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/374586"
        },
        {
          "name": "VDB-374586 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/374586/cti"
        },
        {
          "name": "CVE-2026-13580 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-13580"
        },
        {
          "name": "Submit #844115 | EDIMAX EW-7478APC EW-7478APC 1.04 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/844115"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-formQoS-34b53a41781f8095bffacdea103a82d1"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-29T00:34:27.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Edimax EW-7478APC POST Request formQoS buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-13580",
    "datePublished": "2026-06-29T15:00:18.232Z",
    "dateReserved": "2026-06-28T22:29:13.511Z",
    "dateUpdated": "2026-06-29T16:19:48.827Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-13580",
      "date": "2026-06-30",
      "epss": "0.00445",
      "percentile": "0.35555"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-13580\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2026-06-29T16:16:38.280\",\"lastModified\":\"2026-06-29T18:47:21.983\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A security vulnerability has been detected in Edimax EW-7478APC 1.04. This affects the function formQoS of the file /goform/formQoS of the component POST Request Handler. The manipulation of the argument selSSID leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}],\"affected\":[{\"source\":\"cna@vuldb.com\",\"affectedData\":[{\"vendor\":\"Edimax\",\"product\":\"EW-7478APC\",\"cpes\":[\"cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*\"],\"modules\":[\"POST Request Handler\"],\"versions\":[{\"version\":\"1.04\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-06-29T16:19:43.559040Z\",\"id\":\"CVE-2026-13580\",\"options\":[{\"exploitation\":\"poc\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"},{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-formQoS-34b53a41781f8095bffacdea103a82d1\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/cve/CVE-2026-13580\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/submit/844115\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/vuln/374586\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/vuln/374586/cti\",\"source\":\"cna@vuldb.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-13580\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-06-29T16:19:43.559040Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-06-29T16:19:45.673Z\"}}], \"cna\": {\"title\": \"Edimax EW-7478APC POST Request formQoS buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"wxhwxhwxh_mie (VulDB User)\"}, {\"lang\": \"en\", \"type\": \"coordinator\", \"value\": \"VulDB CNA Team\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*\"], \"vendor\": \"Edimax\", \"modules\": [\"POST Request Handler\"], \"product\": \"EW-7478APC\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.04\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2026-06-28T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2026-06-29T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2026-06-29T00:34:27.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/vuln/374586\", \"name\": \"VDB-374586 | Edimax EW-7478APC POST Request formQoS buffer overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/vuln/374586/cti\", \"name\": \"VDB-374586 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/cve/CVE-2026-13580\", \"name\": \"CVE-2026-13580 | CVE Analysis and Report\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://vuldb.com/submit/844115\", \"name\": \"Submit #844115 | EDIMAX EW-7478APC EW-7478APC 1.04 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-formQoS-34b53a41781f8095bffacdea103a82d1\", \"tags\": [\"broken-link\", \"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A security vulnerability has been detected in Edimax EW-7478APC 1.04. This affects the function formQoS of the file /goform/formQoS of the component POST Request Handler. The manipulation of the argument selSSID leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2026-06-29T15:00:18.232Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-13580\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-29T16:19:48.827Z\", \"dateReserved\": \"2026-06-28T22:29:13.511Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2026-06-29T15:00:18.232Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…