CVE-2026-108936 (GCVE-0-2026-108936)
Vulnerability from nvd – Published: 2026-10-12 22:30 – Updated: 2026-10-14 12:43
VLAI
EPSS
VEX
Title
Edimax BR-6208AC QoS Page formQoS cross site scripting
Summary
A security vulnerability has been detected in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formQoS of the component QoS Page. The manipulation leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-14 12:42 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416760 | vdb-entry |
| https://vuldb.com/vuln/416760/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108936 | third-party-advisory |
| https://vuldb.com/submit/1005198 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108936",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-14T12:42:37.088378Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-14T12:43:57.632Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"QoS Page"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formQoS of the component QoS Page. The manipulation leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:30:14.458Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416760 | Edimax BR-6208AC QoS Page formQoS cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416760"
},
{
"name": "VDB-416760 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416760/cti"
},
{
"name": "CVE-2026-108936 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108936"
},
{
"name": "Submit #1005198 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005198"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_QOS"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC QoS Page formQoS cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108936",
"datePublished": "2026-10-12T22:30:14.458Z",
"dateReserved": "2026-10-11T18:22:32.233Z",
"dateUpdated": "2026-10-14T12:43:57.632Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108935 (GCVE-0-2026-108935)
Vulnerability from nvd – Published: 2026-10-12 22:15 – Updated: 2026-10-15 14:02
VLAI
EPSS
VEX
Title
Edimax BR-6208AC Port Forwarding formPortFw cross site scripting
Summary
A weakness has been identified in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formPortFw of the component Port Forwarding Page. Executing a manipulation can lead to cross site scripting. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 14:01 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416759 | vdb-entry |
| https://vuldb.com/vuln/416759/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108935 | third-party-advisory |
| https://vuldb.com/submit/1005197 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108935",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T14:01:53.690549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T14:02:03.883Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Port Forwarding Page"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formPortFw of the component Port Forwarding Page. Executing a manipulation can lead to cross site scripting. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:15:11.734Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416759 | Edimax BR-6208AC Port Forwarding formPortFw cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416759"
},
{
"name": "VDB-416759 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416759/cti"
},
{
"name": "CVE-2026-108935 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108935"
},
{
"name": "Submit #1005197 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005197"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_Port_Forwarding"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC Port Forwarding formPortFw cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108935",
"datePublished": "2026-10-12T22:15:11.734Z",
"dateReserved": "2026-10-11T18:22:28.877Z",
"dateUpdated": "2026-10-15T14:02:03.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108934 (GCVE-0-2026-108934)
Vulnerability from nvd – Published: 2026-10-12 22:00 – Updated: 2026-10-13 13:44
VLAI
EPSS
VEX
Title
Edimax BR-6208AC HTTP Blocking formUrlb cross site scripting
Summary
A security flaw has been discovered in Edimax BR-6208AC 1.32. Affected by this vulnerability is an unknown functionality of the file /goform/formUrlb of the component HTTP Blocking Page. Performing a manipulation results in cross site scripting. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-13 13:44 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416758 | vdb-entry |
| https://vuldb.com/vuln/416758/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108934 | third-party-advisory |
| https://vuldb.com/submit/1005176 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108934",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T13:44:10.439114Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T13:44:20.684Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"HTTP Blocking Page"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Edimax BR-6208AC 1.32. Affected by this vulnerability is an unknown functionality of the file /goform/formUrlb of the component HTTP Blocking Page. Performing a manipulation results in cross site scripting. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:00:16.792Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416758 | Edimax BR-6208AC HTTP Blocking formUrlb cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416758"
},
{
"name": "VDB-416758 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416758/cti"
},
{
"name": "CVE-2026-108934 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108934"
},
{
"name": "Submit #1005176 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005176"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_HTTP_Blocking"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC HTTP Blocking formUrlb cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108934",
"datePublished": "2026-10-12T22:00:16.792Z",
"dateReserved": "2026-10-11T18:22:24.954Z",
"dateUpdated": "2026-10-13T13:44:20.684Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108933 (GCVE-0-2026-108933)
Vulnerability from nvd – Published: 2026-10-12 21:45 – Updated: 2026-10-16 17:19
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formFilter cross site scripting
Summary
A vulnerability was identified in Edimax BR-6208AC 1.32. Affected is an unknown function of the file /goform/formFilter. Such manipulation leads to cross site scripting. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-16 16:27 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416757 | vdb-entry |
| https://vuldb.com/vuln/416757/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108933 | third-party-advisory |
| https://vuldb.com/submit/1005175 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108933",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-16T16:27:48.237763Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-16T17:19:10.453Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.32. Affected is an unknown function of the file /goform/formFilter. Such manipulation leads to cross site scripting. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T21:45:11.710Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416757 | Edimax BR-6208AC formFilter cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416757"
},
{
"name": "VDB-416757 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416757/cti"
},
{
"name": "CVE-2026-108933 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108933"
},
{
"name": "Submit #1005175 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005175"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_Access_Control"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:38.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formFilter cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108933",
"datePublished": "2026-10-12T21:45:11.710Z",
"dateReserved": "2026-10-11T18:22:20.810Z",
"dateUpdated": "2026-10-16T17:19:10.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108918 (GCVE-0-2026-108918)
Vulnerability from nvd – Published: 2026-10-12 18:00 – Updated: 2026-10-15 13:37 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formWlanMP command injection
Summary
A vulnerability was identified in Edimax BR-6208AC 1.32. Impacted is an unknown function of the file /goform/formWlanMP. The manipulation of the argument readE2P leads to command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 13:37 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416730 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416730/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108918 | third-party-advisory |
| https://vuldb.com/submit/977200 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108918",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T13:37:14.278528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T13:37:32.864Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.32. Impacted is an unknown function of the file /goform/formWlanMP. The manipulation of the argument readE2P leads to command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T18:00:18.352Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416730 | Edimax BR-6208AC formWlanMP command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416730"
},
{
"name": "VDB-416730 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416730/cti"
},
{
"name": "CVE-2026-108918 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108918"
},
{
"name": "Submit #977200 | Edimax BR-6208AC BR-6208AC_1.32 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977200"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formWlanMP"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:57:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formWlanMP command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108918",
"datePublished": "2026-10-12T18:00:18.352Z",
"dateReserved": "2026-10-11T15:51:44.327Z",
"dateUpdated": "2026-10-15T13:37:32.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108917 (GCVE-0-2026-108917)
Vulnerability from nvd – Published: 2026-10-12 17:45 – Updated: 2026-10-13 16:04 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formAutoFWupgrade command injection
Summary
A vulnerability was determined in Edimax BR-6208AC 1.32. This issue affects some unknown processing of the file /goform/formAutoFWupgrade. Executing a manipulation of the argument tftpsIP can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-13 16:03 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416729 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416729/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108917 | third-party-advisory |
| https://vuldb.com/submit/977199 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploitpatch |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108917",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T16:03:40.017470Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T16:04:13.730Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Edimax BR-6208AC 1.32. This issue affects some unknown processing of the file /goform/formAutoFWupgrade. Executing a manipulation of the argument tftpsIP can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:45:15.881Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416729 | Edimax BR-6208AC formAutoFWupgrade command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416729"
},
{
"name": "VDB-416729 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416729/cti"
},
{
"name": "CVE-2026-108917 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108917"
},
{
"name": "Submit #977199 | Edimax BR-6208AC BR-6208AC_1.32 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977199"
},
{
"tags": [
"exploit",
"patch"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formAutoFWupgrade"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:57:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formAutoFWupgrade command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108917",
"datePublished": "2026-10-12T17:45:15.881Z",
"dateReserved": "2026-10-11T15:51:40.725Z",
"dateUpdated": "2026-10-13T16:04:13.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108916 (GCVE-0-2026-108916)
Vulnerability from nvd – Published: 2026-10-12 17:30 – Updated: 2026-10-15 15:14 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formAccept command injection
Summary
A vulnerability was found in Edimax BR-6208AC 1.32. This vulnerability affects unknown code of the file /goform/formAccept. Performing a manipulation of the argument submit-url results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 14:52 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416728 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416728/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108916 | third-party-advisory |
| https://vuldb.com/submit/977198 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108916",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T14:52:28.434483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T15:14:35.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Edimax BR-6208AC 1.32. This vulnerability affects unknown code of the file /goform/formAccept. Performing a manipulation of the argument submit-url results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:30:22.828Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416728 | Edimax BR-6208AC formAccept command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416728"
},
{
"name": "VDB-416728 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416728/cti"
},
{
"name": "CVE-2026-108916 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108916"
},
{
"name": "Submit #977198 | Edimax BR-6208AC BR-6208AC_1.32 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977198"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formAccept"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:56:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formAccept command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108916",
"datePublished": "2026-10-12T17:30:22.828Z",
"dateReserved": "2026-10-11T15:51:36.800Z",
"dateUpdated": "2026-10-15T15:14:35.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108915 (GCVE-0-2026-108915)
Vulnerability from nvd – Published: 2026-10-12 17:15 – Updated: 2026-10-13 16:25 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formWlanMP buffer overflow
Summary
A vulnerability has been found in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formWlanMP. Such manipulation of the argument ateBW leads to buffer overflow. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
9.9 (Critical)
9.9 (Critical)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-13 16:24 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416727 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416727/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108915 | third-party-advisory |
| https://vuldb.com/submit/977196 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108915",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T16:24:51.866322Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T16:25:29.040Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formWlanMP. Such manipulation of the argument ateBW leads to buffer overflow. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:15:16.448Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416727 | Edimax BR-6208AC formWlanMP buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416727"
},
{
"name": "VDB-416727 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416727/cti"
},
{
"name": "CVE-2026-108915 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108915"
},
{
"name": "Submit #977196 | Edimax BR-6208AC BR-6208AC_1.32 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977196"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/BufferOverflow_formWlanMP"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:56:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formWlanMP buffer overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108915",
"datePublished": "2026-10-12T17:15:16.448Z",
"dateReserved": "2026-10-11T15:51:32.570Z",
"dateUpdated": "2026-10-13T16:25:29.040Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108914 (GCVE-0-2026-108914)
Vulnerability from nvd – Published: 2026-10-12 17:00 – Updated: 2026-10-15 13:34 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formWlSiteSurvey buffer overflow
Summary
A flaw has been found in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formWlSiteSurvey. This manipulation of the argument ifname causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
9.9 (Critical)
9.9 (Critical)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 13:34 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416726 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416726/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108914 | third-party-advisory |
| https://vuldb.com/submit/977194 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108914",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T13:34:48.739764Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T13:34:58.383Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formWlSiteSurvey. This manipulation of the argument ifname causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:00:20.439Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416726 | Edimax BR-6208AC formWlSiteSurvey buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416726"
},
{
"name": "VDB-416726 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416726/cti"
},
{
"name": "CVE-2026-108914 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108914"
},
{
"name": "Submit #977194 | Edimax BR-6208AC BR-6208AC_1.32 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977194"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/BufferOverflow_formWlSiteSurvey"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:56:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formWlSiteSurvey buffer overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108914",
"datePublished": "2026-10-12T17:00:20.439Z",
"dateReserved": "2026-10-11T15:51:27.820Z",
"dateUpdated": "2026-10-15T13:34:58.383Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-100745 (GCVE-0-2026-100745)
Vulnerability from nvd – Published: 2026-09-27 02:00 – Updated: 2026-09-28 15:57
VLAI
EPSS
VEX
Title
Edimax BR-6428nC Wireless Wizard formWizSurvey stack-based overflow
Summary
A vulnerability has been found in Edimax BR-6428nC 1.16. The impacted element is an unknown function of the file /goform/formWizSurvey of the component Wireless Wizard Handler. The manipulation of the argument interface1/interface2 leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-28 15:56 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/410616 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/410616/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-100745 | third-party-advisory |
| https://vuldb.com/submit/906337 | third-party-advisory |
| https://tzh00203.notion.site/Edimax-BR-6428nC-for… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-100745",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-28T15:56:37.229449Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-28T15:57:54.488Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6428nc:*:*:*:*:*:*:*:*"
],
"modules": [
"Wireless Wizard Handler"
],
"product": "BR-6428nC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.16"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "tian (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Edimax BR-6428nC 1.16. The impacted element is an unknown function of the file /goform/formWizSurvey of the component Wireless Wizard Handler. The manipulation of the argument interface1/interface2 leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-27T02:00:16.547Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-410616 | Edimax BR-6428nC Wireless Wizard formWizSurvey stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/410616"
},
{
"name": "VDB-410616 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/410616/cti"
},
{
"name": "CVE-2026-100745 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-100745"
},
{
"name": "Submit #906337 | Edimax BR-6428nC v1.16 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/906337"
},
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/Edimax-BR-6428nC-formWizSurvey-Interface-Stack-Overflow-33db5c52018a80b5b950feb29846006c"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-09-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-09-26T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-09-26T13:31:17.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6428nC Wireless Wizard formWizSurvey stack-based overflow",
"x_generator": [
"VulDB PVTS v202609"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-100745",
"datePublished": "2026-09-27T02:00:16.547Z",
"dateReserved": "2026-09-26T11:26:12.447Z",
"dateUpdated": "2026-09-28T15:57:54.488Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-96892 (GCVE-0-2026-96892)
Vulnerability from nvd – Published: 2026-09-24 03:15 – Updated: 2026-09-24 12:49
VLAI
EPSS
VEX
Title
Edimax BR-6428nC goform websRedirect redirect
Summary
A flaw has been found in Edimax BR-6428nC 1.16. The impacted element is the function websRedirect of the component goform Handler. Executing a manipulation of the argument submit-url can lead to open redirect. The attack may be launched remotely. The exploit has been published and may be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-24 12:48 UTC
CWE
- CWE-601 - Open Redirect
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/409175 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/409175/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-96892 | third-party-advisory |
| https://vuldb.com/submit/906338 | third-party-advisory |
| https://tzh00203.notion.site/Edimax-BR-6428nC-Ope… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-96892",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-24T12:48:59.165927Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T12:49:51.062Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6428nc:*:*:*:*:*:*:*:*"
],
"modules": [
"goform Handler"
],
"product": "BR-6428nC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.16"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "tian (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Edimax BR-6428nC 1.16. The impacted element is the function websRedirect of the component goform Handler. Executing a manipulation of the argument submit-url can lead to open redirect. The attack may be launched remotely. The exploit has been published and may be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "Open Redirect",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T03:15:07.690Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-409175 | Edimax BR-6428nC goform websRedirect redirect",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/409175"
},
{
"name": "VDB-409175 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/409175/cti"
},
{
"name": "CVE-2026-96892 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-96892"
},
{
"name": "Submit #906338 | Edimax BR-6428nC v1.16 Open Redirect",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/906338"
},
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/Edimax-BR-6428nC-Open-Redirect-via-submit-url-33db5c52018a808a8c34c1cb68db7aab"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-09-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-09-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-09-23T21:35:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6428nC goform websRedirect redirect",
"x_generator": [
"VulDB PVTS v202609"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-96892",
"datePublished": "2026-09-24T03:15:07.690Z",
"dateReserved": "2026-09-23T19:29:38.464Z",
"dateUpdated": "2026-09-24T12:49:51.062Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82703 (GCVE-0-2026-82703)
Vulnerability from nvd – Published: 2026-08-31 14:45 – Updated: 2026-08-31 21:58
VLAI
EPSS
VEX
Title
Edimax BR-6214K asp_setPing Endpoint ping.asp system os command injection
Summary
A security flaw has been discovered in Edimax BR-6214K 1.40. This vulnerability affects the function system of the file www/ping.asp of the component asp_setPing Endpoint. Performing a manipulation of the argument pingstr results in os command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-31 21:50 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/397192 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/397192/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-82703 | third-party-advisory |
| https://vuldb.com/submit/881276 | third-party-advisory |
| https://github.com/dxz0069/WAVLINK-WN530H4-Comman… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82703",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-31T21:50:17.054406Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T21:58:04.333Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6214k:*:*:*:*:*:*:*:*"
],
"modules": [
"asp_setPing Endpoint"
],
"product": "BR-6214K",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ST4R0002 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Edimax BR-6214K 1.40. This vulnerability affects the function system of the file www/ping.asp of the component asp_setPing Endpoint. Performing a manipulation of the argument pingstr results in os command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T14:45:09.220Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-397192 | Edimax BR-6214K asp_setPing Endpoint ping.asp system os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/397192"
},
{
"name": "VDB-397192 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/397192/cti"
},
{
"name": "CVE-2026-82703 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-82703"
},
{
"name": "Submit #881276 | Edimax Edimax BR-6214K Router 1.40 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/881276"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Edimax-setPing__Edimax__other.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-30T20:33:10.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6214K asp_setPing Endpoint ping.asp system os command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-82703",
"datePublished": "2026-08-31T14:45:09.220Z",
"dateReserved": "2026-08-30T18:27:32.519Z",
"dateUpdated": "2026-08-31T21:58:04.333Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82702 (GCVE-0-2026-82702)
Vulnerability from nvd – Published: 2026-08-31 14:30 – Updated: 2026-08-31 14:44
VLAI
EPSS
VEX
Title
Edimax BR-6214K asp_WlanMP Endpoint wlanMP.asp system os command injection
Summary
A vulnerability was identified in Edimax BR-6214K 1.40. This affects the function system of the file www/wlanMP.asp of the component asp_WlanMP Endpoint. Such manipulation of the argument ateFunc leads to os command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-31 14:44 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/397191 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/397191/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-82702 | third-party-advisory |
| https://vuldb.com/submit/881275 | third-party-advisory |
| https://github.com/dxz0069/WAVLINK-WN530H4-Comman… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82702",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-31T14:44:30.317180Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T14:44:39.188Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6214k:*:*:*:*:*:*:*:*"
],
"modules": [
"asp_WlanMP Endpoint"
],
"product": "BR-6214K",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ST4R0002 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6214K 1.40. This affects the function system of the file www/wlanMP.asp of the component asp_WlanMP Endpoint. Such manipulation of the argument ateFunc leads to os command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T14:30:07.775Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-397191 | Edimax BR-6214K asp_WlanMP Endpoint wlanMP.asp system os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/397191"
},
{
"name": "VDB-397191 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/397191/cti"
},
{
"name": "CVE-2026-82702 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-82702"
},
{
"name": "Submit #881275 | Edimax Edimax BR-6214K Router 1.40 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/881275"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Edimax-WlanMP__Edimax__other.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-30T20:33:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6214K asp_WlanMP Endpoint wlanMP.asp system os command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-82702",
"datePublished": "2026-08-31T14:30:07.775Z",
"dateReserved": "2026-08-30T18:27:17.236Z",
"dateUpdated": "2026-08-31T14:44:39.188Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19963 (GCVE-0-2026-19963)
Vulnerability from nvd – Published: 2026-08-16 23:30 – Updated: 2026-08-17 15:25
VLAI
EPSS
VEX
Title
Edimax EW-7478APC stainfo command injection
Summary
A vulnerability has been found in Edimax EW-7478APC 1.04. Affected by this issue is the function stainfo of the file /goform/stainfo. The manipulation of the argument interface leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 15:25 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/391140 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/391140/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-19963 | third-party-advisory |
| https://vuldb.com/submit/872877 | third-party-advisory |
| https://lavender-bicycle-a5a.notion.site/EDIMAX-E… | exploit |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Edimax | EW-7478APC |
Affected:
1.04
cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19963",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T15:25:45.492013Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T15:25:57.747Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*"
],
"product": "EW-7478APC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.04"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Edimax EW-7478APC 1.04. Affected by this issue is the function stainfo of the file /goform/stainfo. The manipulation of the argument interface leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-16T23:30:10.002Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-391140 | Edimax EW-7478APC stainfo command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/391140"
},
{
"name": "VDB-391140 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/391140/cti"
},
{
"name": "CVE-2026-19963 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-19963"
},
{
"name": "Submit #872877 | EDIMAX EW-7478APC EW-7478APC 1.04 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/872877"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-stainfo-34b53a41781f80ed8e15c109f7a50844?source=copy_link"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-16T09:13:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax EW-7478APC stainfo command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-19963",
"datePublished": "2026-08-16T23:30:10.002Z",
"dateReserved": "2026-08-16T07:07:53.770Z",
"dateUpdated": "2026-08-17T15:25:57.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19962 (GCVE-0-2026-19962)
Vulnerability from nvd – Published: 2026-08-16 23:15 – Updated: 2026-08-18 14:12
VLAI
EPSS
VEX
Title
Edimax EW-7478APC setWAN command injection
Summary
A flaw has been found in Edimax EW-7478APC 1.04. Affected by this vulnerability is the function setWAN of the file /goform/setWAN. Executing a manipulation of the argument pppUserName/pptpUserName/L2TPUserName can lead to command injection. The attack may be performed from remote. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-18 14:12 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/391139 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/391139/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-19962 | third-party-advisory |
| https://vuldb.com/submit/872876 | third-party-advisory |
| https://lavender-bicycle-a5a.notion.site/EDIMAX-E… | exploit |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Edimax | EW-7478APC |
Affected:
1.04
cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19962",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-18T14:12:11.411560Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-18T14:12:31.511Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*"
],
"product": "EW-7478APC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.04"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Edimax EW-7478APC 1.04. Affected by this vulnerability is the function setWAN of the file /goform/setWAN. Executing a manipulation of the argument pppUserName/pptpUserName/L2TPUserName can lead to command injection. The attack may be performed from remote. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-16T23:15:11.641Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-391139 | Edimax EW-7478APC setWAN command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/391139"
},
{
"name": "VDB-391139 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/391139/cti"
},
{
"name": "CVE-2026-19962 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-19962"
},
{
"name": "Submit #872876 | EDIMAX EW-7478APC EW-7478APC 1.04 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/872876"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-setWAN-34b53a41781f808aaf2bc972cc6d38d3?source=copy_link"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-16T09:13:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax EW-7478APC setWAN command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-19962",
"datePublished": "2026-08-16T23:15:11.641Z",
"dateReserved": "2026-08-16T07:07:49.713Z",
"dateUpdated": "2026-08-18T14:12:31.511Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19961 (GCVE-0-2026-19961)
Vulnerability from nvd – Published: 2026-08-16 23:00 – Updated: 2026-08-17 16:14
VLAI
EPSS
VEX
Title
Edimax EW-7478APC formWlSiteSurvey buffer overflow
Summary
A vulnerability was detected in Edimax EW-7478APC 1.04. Affected is the function formWlSiteSurvey of the file /goform/formWlSiteSurvey. Performing a manipulation of the argument selSSID results in buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
9.9 (Critical)
9.9 (Critical)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 16:12 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/391138 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/391138/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-19961 | third-party-advisory |
| https://vuldb.com/submit/872875 | third-party-advisory |
| https://lavender-bicycle-a5a.notion.site/EDIMAX-E… | exploit |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Edimax | EW-7478APC |
Affected:
1.04
cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19961",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T16:12:35.931232Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T16:14:40.396Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*"
],
"product": "EW-7478APC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.04"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Edimax EW-7478APC 1.04. Affected is the function formWlSiteSurvey of the file /goform/formWlSiteSurvey. Performing a manipulation of the argument selSSID results in buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-16T23:00:15.655Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-391138 | Edimax EW-7478APC formWlSiteSurvey buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/391138"
},
{
"name": "VDB-391138 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/391138/cti"
},
{
"name": "CVE-2026-19961 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-19961"
},
{
"name": "Submit #872875 | EDIMAX EW-7478APC EW-7478APC 1.04 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/872875"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-formWlSiteSurvey-34b53a41781f804fb328d87416095401?source=copy_link"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-16T09:13:09.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax EW-7478APC formWlSiteSurvey buffer overflow",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-19961",
"datePublished": "2026-08-16T23:00:15.655Z",
"dateReserved": "2026-08-16T07:07:45.859Z",
"dateUpdated": "2026-08-17T16:14:40.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108936 (GCVE-0-2026-108936)
Vulnerability from cvelistv5 – Published: 2026-10-12 22:30 – Updated: 2026-10-14 12:43
VLAI
EPSS
VEX
Title
Edimax BR-6208AC QoS Page formQoS cross site scripting
Summary
A security vulnerability has been detected in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formQoS of the component QoS Page. The manipulation leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-14 12:42 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416760 | vdb-entry |
| https://vuldb.com/vuln/416760/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108936 | third-party-advisory |
| https://vuldb.com/submit/1005198 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108936",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-14T12:42:37.088378Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-14T12:43:57.632Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"QoS Page"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formQoS of the component QoS Page. The manipulation leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:30:14.458Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416760 | Edimax BR-6208AC QoS Page formQoS cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416760"
},
{
"name": "VDB-416760 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416760/cti"
},
{
"name": "CVE-2026-108936 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108936"
},
{
"name": "Submit #1005198 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005198"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_QOS"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC QoS Page formQoS cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108936",
"datePublished": "2026-10-12T22:30:14.458Z",
"dateReserved": "2026-10-11T18:22:32.233Z",
"dateUpdated": "2026-10-14T12:43:57.632Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108935 (GCVE-0-2026-108935)
Vulnerability from cvelistv5 – Published: 2026-10-12 22:15 – Updated: 2026-10-15 14:02
VLAI
EPSS
VEX
Title
Edimax BR-6208AC Port Forwarding formPortFw cross site scripting
Summary
A weakness has been identified in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formPortFw of the component Port Forwarding Page. Executing a manipulation can lead to cross site scripting. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 14:01 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416759 | vdb-entry |
| https://vuldb.com/vuln/416759/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108935 | third-party-advisory |
| https://vuldb.com/submit/1005197 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108935",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T14:01:53.690549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T14:02:03.883Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Port Forwarding Page"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formPortFw of the component Port Forwarding Page. Executing a manipulation can lead to cross site scripting. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:15:11.734Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416759 | Edimax BR-6208AC Port Forwarding formPortFw cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416759"
},
{
"name": "VDB-416759 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416759/cti"
},
{
"name": "CVE-2026-108935 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108935"
},
{
"name": "Submit #1005197 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005197"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_Port_Forwarding"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC Port Forwarding formPortFw cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108935",
"datePublished": "2026-10-12T22:15:11.734Z",
"dateReserved": "2026-10-11T18:22:28.877Z",
"dateUpdated": "2026-10-15T14:02:03.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108934 (GCVE-0-2026-108934)
Vulnerability from cvelistv5 – Published: 2026-10-12 22:00 – Updated: 2026-10-13 13:44
VLAI
EPSS
VEX
Title
Edimax BR-6208AC HTTP Blocking formUrlb cross site scripting
Summary
A security flaw has been discovered in Edimax BR-6208AC 1.32. Affected by this vulnerability is an unknown functionality of the file /goform/formUrlb of the component HTTP Blocking Page. Performing a manipulation results in cross site scripting. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-13 13:44 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416758 | vdb-entry |
| https://vuldb.com/vuln/416758/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108934 | third-party-advisory |
| https://vuldb.com/submit/1005176 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108934",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T13:44:10.439114Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T13:44:20.684Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"HTTP Blocking Page"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Edimax BR-6208AC 1.32. Affected by this vulnerability is an unknown functionality of the file /goform/formUrlb of the component HTTP Blocking Page. Performing a manipulation results in cross site scripting. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T22:00:16.792Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416758 | Edimax BR-6208AC HTTP Blocking formUrlb cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416758"
},
{
"name": "VDB-416758 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416758/cti"
},
{
"name": "CVE-2026-108934 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108934"
},
{
"name": "Submit #1005176 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005176"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_HTTP_Blocking"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC HTTP Blocking formUrlb cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108934",
"datePublished": "2026-10-12T22:00:16.792Z",
"dateReserved": "2026-10-11T18:22:24.954Z",
"dateUpdated": "2026-10-13T13:44:20.684Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108933 (GCVE-0-2026-108933)
Vulnerability from cvelistv5 – Published: 2026-10-12 21:45 – Updated: 2026-10-16 17:19
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formFilter cross site scripting
Summary
A vulnerability was identified in Edimax BR-6208AC 1.32. Affected is an unknown function of the file /goform/formFilter. Such manipulation leads to cross site scripting. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-16 16:27 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416757 | vdb-entry |
| https://vuldb.com/vuln/416757/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108933 | third-party-advisory |
| https://vuldb.com/submit/1005175 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108933",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-16T16:27:48.237763Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-16T17:19:10.453Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.32. Affected is an unknown function of the file /goform/formFilter. Such manipulation leads to cross site scripting. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T21:45:11.710Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416757 | Edimax BR-6208AC formFilter cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/416757"
},
{
"name": "VDB-416757 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416757/cti"
},
{
"name": "CVE-2026-108933 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108933"
},
{
"name": "Submit #1005175 | Edimax BR-6208AC BR-6208AC_1.32 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/1005175"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/XSS_Access_Control"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T20:27:38.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formFilter cross site scripting",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108933",
"datePublished": "2026-10-12T21:45:11.710Z",
"dateReserved": "2026-10-11T18:22:20.810Z",
"dateUpdated": "2026-10-16T17:19:10.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108918 (GCVE-0-2026-108918)
Vulnerability from cvelistv5 – Published: 2026-10-12 18:00 – Updated: 2026-10-15 13:37 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formWlanMP command injection
Summary
A vulnerability was identified in Edimax BR-6208AC 1.32. Impacted is an unknown function of the file /goform/formWlanMP. The manipulation of the argument readE2P leads to command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 13:37 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416730 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416730/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108918 | third-party-advisory |
| https://vuldb.com/submit/977200 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108918",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T13:37:14.278528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T13:37:32.864Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.32. Impacted is an unknown function of the file /goform/formWlanMP. The manipulation of the argument readE2P leads to command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T18:00:18.352Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416730 | Edimax BR-6208AC formWlanMP command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416730"
},
{
"name": "VDB-416730 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416730/cti"
},
{
"name": "CVE-2026-108918 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108918"
},
{
"name": "Submit #977200 | Edimax BR-6208AC BR-6208AC_1.32 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977200"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formWlanMP"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:57:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formWlanMP command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108918",
"datePublished": "2026-10-12T18:00:18.352Z",
"dateReserved": "2026-10-11T15:51:44.327Z",
"dateUpdated": "2026-10-15T13:37:32.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108917 (GCVE-0-2026-108917)
Vulnerability from cvelistv5 – Published: 2026-10-12 17:45 – Updated: 2026-10-13 16:04 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formAutoFWupgrade command injection
Summary
A vulnerability was determined in Edimax BR-6208AC 1.32. This issue affects some unknown processing of the file /goform/formAutoFWupgrade. Executing a manipulation of the argument tftpsIP can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-13 16:03 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416729 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416729/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108917 | third-party-advisory |
| https://vuldb.com/submit/977199 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploitpatch |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108917",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T16:03:40.017470Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T16:04:13.730Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Edimax BR-6208AC 1.32. This issue affects some unknown processing of the file /goform/formAutoFWupgrade. Executing a manipulation of the argument tftpsIP can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:45:15.881Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416729 | Edimax BR-6208AC formAutoFWupgrade command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416729"
},
{
"name": "VDB-416729 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416729/cti"
},
{
"name": "CVE-2026-108917 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108917"
},
{
"name": "Submit #977199 | Edimax BR-6208AC BR-6208AC_1.32 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977199"
},
{
"tags": [
"exploit",
"patch"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formAutoFWupgrade"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:57:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formAutoFWupgrade command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108917",
"datePublished": "2026-10-12T17:45:15.881Z",
"dateReserved": "2026-10-11T15:51:40.725Z",
"dateUpdated": "2026-10-13T16:04:13.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108916 (GCVE-0-2026-108916)
Vulnerability from cvelistv5 – Published: 2026-10-12 17:30 – Updated: 2026-10-15 15:14 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formAccept command injection
Summary
A vulnerability was found in Edimax BR-6208AC 1.32. This vulnerability affects unknown code of the file /goform/formAccept. Performing a manipulation of the argument submit-url results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 14:52 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416728 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416728/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108916 | third-party-advisory |
| https://vuldb.com/submit/977198 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108916",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T14:52:28.434483Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T15:14:35.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Edimax BR-6208AC 1.32. This vulnerability affects unknown code of the file /goform/formAccept. Performing a manipulation of the argument submit-url results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:30:22.828Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416728 | Edimax BR-6208AC formAccept command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416728"
},
{
"name": "VDB-416728 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416728/cti"
},
{
"name": "CVE-2026-108916 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108916"
},
{
"name": "Submit #977198 | Edimax BR-6208AC BR-6208AC_1.32 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977198"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formAccept"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:56:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formAccept command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108916",
"datePublished": "2026-10-12T17:30:22.828Z",
"dateReserved": "2026-10-11T15:51:36.800Z",
"dateUpdated": "2026-10-15T15:14:35.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108915 (GCVE-0-2026-108915)
Vulnerability from cvelistv5 – Published: 2026-10-12 17:15 – Updated: 2026-10-13 16:25 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formWlanMP buffer overflow
Summary
A vulnerability has been found in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formWlanMP. Such manipulation of the argument ateBW leads to buffer overflow. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
9.9 (Critical)
9.9 (Critical)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-13 16:24 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416727 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416727/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108915 | third-party-advisory |
| https://vuldb.com/submit/977196 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108915",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T16:24:51.866322Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T16:25:29.040Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Edimax BR-6208AC 1.32. This affects an unknown part of the file /goform/formWlanMP. Such manipulation of the argument ateBW leads to buffer overflow. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:15:16.448Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416727 | Edimax BR-6208AC formWlanMP buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416727"
},
{
"name": "VDB-416727 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416727/cti"
},
{
"name": "CVE-2026-108915 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108915"
},
{
"name": "Submit #977196 | Edimax BR-6208AC BR-6208AC_1.32 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977196"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/BufferOverflow_formWlanMP"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:56:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formWlanMP buffer overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108915",
"datePublished": "2026-10-12T17:15:16.448Z",
"dateReserved": "2026-10-11T15:51:32.570Z",
"dateUpdated": "2026-10-13T16:25:29.040Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-108914 (GCVE-0-2026-108914)
Vulnerability from cvelistv5 – Published: 2026-10-12 17:00 – Updated: 2026-10-15 13:34 Unsupported When Assigned
VLAI
EPSS
VEX
Title
Edimax BR-6208AC formWlSiteSurvey buffer overflow
Summary
A flaw has been found in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formWlSiteSurvey. This manipulation of the argument ifname causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
Severity
9.9 (Critical)
9.9 (Critical)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 13:34 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/416726 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/416726/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-108914 | third-party-advisory |
| https://vuldb.com/submit/977194 | third-party-advisory |
| https://github.com/fizz-is-on-the-way/Iot_vuls/tr… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108914",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-15T13:34:48.739764Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-15T13:34:58.383Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "lcyf-fizz (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formWlSiteSurvey. This manipulation of the argument ifname causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-12T17:00:20.439Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416726 | Edimax BR-6208AC formWlSiteSurvey buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416726"
},
{
"name": "VDB-416726 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416726/cti"
},
{
"name": "CVE-2026-108914 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108914"
},
{
"name": "Submit #977194 | Edimax BR-6208AC BR-6208AC_1.32 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/977194"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/BufferOverflow_formWlSiteSurvey"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2026-10-11T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-11T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-11T17:56:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC formWlSiteSurvey buffer overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108914",
"datePublished": "2026-10-12T17:00:20.439Z",
"dateReserved": "2026-10-11T15:51:27.820Z",
"dateUpdated": "2026-10-15T13:34:58.383Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-100745 (GCVE-0-2026-100745)
Vulnerability from cvelistv5 – Published: 2026-09-27 02:00 – Updated: 2026-09-28 15:57
VLAI
EPSS
VEX
Title
Edimax BR-6428nC Wireless Wizard formWizSurvey stack-based overflow
Summary
A vulnerability has been found in Edimax BR-6428nC 1.16. The impacted element is an unknown function of the file /goform/formWizSurvey of the component Wireless Wizard Handler. The manipulation of the argument interface1/interface2 leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-28 15:56 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/410616 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/410616/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-100745 | third-party-advisory |
| https://vuldb.com/submit/906337 | third-party-advisory |
| https://tzh00203.notion.site/Edimax-BR-6428nC-for… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-100745",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-28T15:56:37.229449Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-28T15:57:54.488Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6428nc:*:*:*:*:*:*:*:*"
],
"modules": [
"Wireless Wizard Handler"
],
"product": "BR-6428nC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.16"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "tian (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Edimax BR-6428nC 1.16. The impacted element is an unknown function of the file /goform/formWizSurvey of the component Wireless Wizard Handler. The manipulation of the argument interface1/interface2 leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-27T02:00:16.547Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-410616 | Edimax BR-6428nC Wireless Wizard formWizSurvey stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/410616"
},
{
"name": "VDB-410616 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/410616/cti"
},
{
"name": "CVE-2026-100745 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-100745"
},
{
"name": "Submit #906337 | Edimax BR-6428nC v1.16 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/906337"
},
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/Edimax-BR-6428nC-formWizSurvey-Interface-Stack-Overflow-33db5c52018a80b5b950feb29846006c"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-09-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-09-26T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-09-26T13:31:17.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6428nC Wireless Wizard formWizSurvey stack-based overflow",
"x_generator": [
"VulDB PVTS v202609"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-100745",
"datePublished": "2026-09-27T02:00:16.547Z",
"dateReserved": "2026-09-26T11:26:12.447Z",
"dateUpdated": "2026-09-28T15:57:54.488Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-96892 (GCVE-0-2026-96892)
Vulnerability from cvelistv5 – Published: 2026-09-24 03:15 – Updated: 2026-09-24 12:49
VLAI
EPSS
VEX
Title
Edimax BR-6428nC goform websRedirect redirect
Summary
A flaw has been found in Edimax BR-6428nC 1.16. The impacted element is the function websRedirect of the component goform Handler. Executing a manipulation of the argument submit-url can lead to open redirect. The attack may be launched remotely. The exploit has been published and may be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-24 12:48 UTC
CWE
- CWE-601 - Open Redirect
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/409175 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/409175/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-96892 | third-party-advisory |
| https://vuldb.com/submit/906338 | third-party-advisory |
| https://tzh00203.notion.site/Edimax-BR-6428nC-Ope… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-96892",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-24T12:48:59.165927Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T12:49:51.062Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6428nc:*:*:*:*:*:*:*:*"
],
"modules": [
"goform Handler"
],
"product": "BR-6428nC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.16"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "tian (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Edimax BR-6428nC 1.16. The impacted element is the function websRedirect of the component goform Handler. Executing a manipulation of the argument submit-url can lead to open redirect. The attack may be launched remotely. The exploit has been published and may be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "Open Redirect",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T03:15:07.690Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-409175 | Edimax BR-6428nC goform websRedirect redirect",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/409175"
},
{
"name": "VDB-409175 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/409175/cti"
},
{
"name": "CVE-2026-96892 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-96892"
},
{
"name": "Submit #906338 | Edimax BR-6428nC v1.16 Open Redirect",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/906338"
},
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/Edimax-BR-6428nC-Open-Redirect-via-submit-url-33db5c52018a808a8c34c1cb68db7aab"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-09-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-09-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-09-23T21:35:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6428nC goform websRedirect redirect",
"x_generator": [
"VulDB PVTS v202609"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-96892",
"datePublished": "2026-09-24T03:15:07.690Z",
"dateReserved": "2026-09-23T19:29:38.464Z",
"dateUpdated": "2026-09-24T12:49:51.062Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82703 (GCVE-0-2026-82703)
Vulnerability from cvelistv5 – Published: 2026-08-31 14:45 – Updated: 2026-08-31 21:58
VLAI
EPSS
VEX
Title
Edimax BR-6214K asp_setPing Endpoint ping.asp system os command injection
Summary
A security flaw has been discovered in Edimax BR-6214K 1.40. This vulnerability affects the function system of the file www/ping.asp of the component asp_setPing Endpoint. Performing a manipulation of the argument pingstr results in os command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-31 21:50 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/397192 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/397192/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-82703 | third-party-advisory |
| https://vuldb.com/submit/881276 | third-party-advisory |
| https://github.com/dxz0069/WAVLINK-WN530H4-Comman… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82703",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-31T21:50:17.054406Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T21:58:04.333Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6214k:*:*:*:*:*:*:*:*"
],
"modules": [
"asp_setPing Endpoint"
],
"product": "BR-6214K",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ST4R0002 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Edimax BR-6214K 1.40. This vulnerability affects the function system of the file www/ping.asp of the component asp_setPing Endpoint. Performing a manipulation of the argument pingstr results in os command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T14:45:09.220Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-397192 | Edimax BR-6214K asp_setPing Endpoint ping.asp system os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/397192"
},
{
"name": "VDB-397192 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/397192/cti"
},
{
"name": "CVE-2026-82703 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-82703"
},
{
"name": "Submit #881276 | Edimax Edimax BR-6214K Router 1.40 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/881276"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Edimax-setPing__Edimax__other.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-30T20:33:10.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6214K asp_setPing Endpoint ping.asp system os command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-82703",
"datePublished": "2026-08-31T14:45:09.220Z",
"dateReserved": "2026-08-30T18:27:32.519Z",
"dateUpdated": "2026-08-31T21:58:04.333Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82702 (GCVE-0-2026-82702)
Vulnerability from cvelistv5 – Published: 2026-08-31 14:30 – Updated: 2026-08-31 14:44
VLAI
EPSS
VEX
Title
Edimax BR-6214K asp_WlanMP Endpoint wlanMP.asp system os command injection
Summary
A vulnerability was identified in Edimax BR-6214K 1.40. This affects the function system of the file www/wlanMP.asp of the component asp_WlanMP Endpoint. Such manipulation of the argument ateFunc leads to os command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-31 14:44 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/397191 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/397191/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-82702 | third-party-advisory |
| https://vuldb.com/submit/881275 | third-party-advisory |
| https://github.com/dxz0069/WAVLINK-WN530H4-Comman… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82702",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-31T14:44:30.317180Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T14:44:39.188Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:br-6214k:*:*:*:*:*:*:*:*"
],
"modules": [
"asp_WlanMP Endpoint"
],
"product": "BR-6214K",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ST4R0002 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6214K 1.40. This affects the function system of the file www/wlanMP.asp of the component asp_WlanMP Endpoint. Such manipulation of the argument ateFunc leads to os command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-31T14:30:07.775Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-397191 | Edimax BR-6214K asp_WlanMP Endpoint wlanMP.asp system os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/397191"
},
{
"name": "VDB-397191 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/397191/cti"
},
{
"name": "CVE-2026-82702 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-82702"
},
{
"name": "Submit #881275 | Edimax Edimax BR-6214K Router 1.40 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/881275"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/dxz0069/WAVLINK-WN530H4-Command-Injection-in-set_add_routing/blob/main/Edimax-WlanMP__Edimax__other.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-30T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-30T20:33:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6214K asp_WlanMP Endpoint wlanMP.asp system os command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-82702",
"datePublished": "2026-08-31T14:30:07.775Z",
"dateReserved": "2026-08-30T18:27:17.236Z",
"dateUpdated": "2026-08-31T14:44:39.188Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19963 (GCVE-0-2026-19963)
Vulnerability from cvelistv5 – Published: 2026-08-16 23:30 – Updated: 2026-08-17 15:25
VLAI
EPSS
VEX
Title
Edimax EW-7478APC stainfo command injection
Summary
A vulnerability has been found in Edimax EW-7478APC 1.04. Affected by this issue is the function stainfo of the file /goform/stainfo. The manipulation of the argument interface leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 15:25 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/391140 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/391140/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-19963 | third-party-advisory |
| https://vuldb.com/submit/872877 | third-party-advisory |
| https://lavender-bicycle-a5a.notion.site/EDIMAX-E… | exploit |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Edimax | EW-7478APC |
Affected:
1.04
cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19963",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T15:25:45.492013Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T15:25:57.747Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:edimax:ew-7478apc:*:*:*:*:*:*:*:*"
],
"product": "EW-7478APC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.04"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Edimax EW-7478APC 1.04. Affected by this issue is the function stainfo of the file /goform/stainfo. The manipulation of the argument interface leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-16T23:30:10.002Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-391140 | Edimax EW-7478APC stainfo command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/391140"
},
{
"name": "VDB-391140 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/391140/cti"
},
{
"name": "CVE-2026-19963 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-19963"
},
{
"name": "Submit #872877 | EDIMAX EW-7478APC EW-7478APC 1.04 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/872877"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-stainfo-34b53a41781f80ed8e15c109f7a50844?source=copy_link"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-08-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-08-16T09:13:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax EW-7478APC stainfo command injection",
"x_generator": [
"VulDB PVTS v202608"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-19963",
"datePublished": "2026-08-16T23:30:10.002Z",
"dateReserved": "2026-08-16T07:07:53.770Z",
"dateUpdated": "2026-08-17T15:25:57.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}