Vulnerability from cvelistv5 – Published: 2023-09-13 13:19 – Updated: 2025-08-27 20:32- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | |
|---|---|---|---|
| Wibu | CodeMeter Runtime |
Affected:
0.0 , ≤ 7.60b
(custom)
|
|
| Wibu | CodeMeter Runtime |
Unaffected:
7.21g
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:08:50.775Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-031/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-030/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3935",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:55.835781Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:32:53.842Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CodeMeter Runtime",
"vendor": "Wibu",
"versions": [
{
"lessThanOrEqual": "7.60b",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "CodeMeter Runtime",
"vendor": "Wibu",
"versions": [
{
"status": "unaffected",
"version": "7.21g"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system."
}
],
"value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-19T07:00:20.911Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-031/"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-030/"
}
],
"source": {
"defect": [
"CERT@VDE#64566"
],
"discovery": "UNKNOWN"
},
"title": "Wibu: Buffer Overflow in CodeMeter Runtime",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-3935",
"datePublished": "2023-09-13T13:19:18.392Z",
"dateReserved": "2023-07-25T13:02:40.206Z",
"dateUpdated": "2025-08-27T20:32:53.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-3935",
"date": "2026-05-29",
"epss": "0.00413",
"percentile": "0.61792"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-3935\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-09-13T14:15:09.147\",\"lastModified\":\"2024-11-21T08:18:21.260\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Desbordamiento del B\u00fafer en el servicio de red Wibu CodeMeter Runtime hasta la versi\u00f3n 7.60b permite a un atacante remoto no autenticado lograr RCE y obtener acceso completo al sistema anfitri\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:wibu:codemeter_runtime:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.60c\",\"matchCriteriaId\":\"5F783582-7E13-457E-96E9-8FD2D58580F5\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:oseon:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndIncluding\":\"3.0.22\",\"matchCriteriaId\":\"6BCF0613-5F59-4DAA-9DDB-A9322892353A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:programmingtube:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.1\",\"versionEndIncluding\":\"4.6.3\",\"matchCriteriaId\":\"9648C643-3213-4D0B-A3E0-6C4A092E8DAE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:teczonebend:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"18.02.r8\",\"versionEndIncluding\":\"23.06.01\",\"matchCriteriaId\":\"56F0DB5E-5F18-4DA4-9488-242351FE5994\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:tops_unfold:05.03.00.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"926A92BB-2001-4176-9F73-F7F40F4D58CE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:topscalculation:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.00\",\"versionEndIncluding\":\"22.00.00\",\"matchCriteriaId\":\"903A6767-5E6D-4E98-A756-A3FC99BAF13F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trumpflicenseexpert:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.5.2\",\"versionEndIncluding\":\"1.11.1\",\"matchCriteriaId\":\"54F8DF4D-3C69-4117-88A4-9C0F6838C7DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutops:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"08.00\",\"versionEndIncluding\":\"12.01.00.00\",\"matchCriteriaId\":\"8360F8C5-1F88-420F-91B2-C75EC8A97A0C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutops_cell_classic:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"09.09.02\",\"matchCriteriaId\":\"3240055F-E26E-4BE9-89A9-D50A6FA5E8F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutops_cell_sw48:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"01.00\",\"versionEndIncluding\":\"02.26.0\",\"matchCriteriaId\":\"7CD0343C-7A91-4CF7-B70B-CB2569FFE679\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutops_mark_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"01.00\",\"versionEndIncluding\":\"06.01\",\"matchCriteriaId\":\"EB6D30E6-031C-4104-A573-2FD3773E1CDF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutopsboost:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"06.00.23.00\",\"versionEndIncluding\":\"16.0.22\",\"matchCriteriaId\":\"B55ED3C4-B111-4A8C-BB9F-A50FCCC38432\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutopsfab:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"15.00.23.00\",\"versionEndIncluding\":\"22.8.25\",\"matchCriteriaId\":\"A4180D87-1915-4868-9328-D310282DD7C4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutopsfab_storage_smallstore:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.06.20\",\"versionEndIncluding\":\"20.04.20.00\",\"matchCriteriaId\":\"3C7823FE-A87C-494B-AB35-AB2830884282\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutopsprint:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"00.06.00\",\"versionEndIncluding\":\"01.00\",\"matchCriteriaId\":\"A257AA96-76DA-47CC-A3BA-3CCFB719C62E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutopsprintmultilaserassistant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"01.02\",\"matchCriteriaId\":\"607CE0A6-C1CB-4B30-A7C7-FFEDF8DB0DA1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:trutopsweld:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.198.241\",\"versionEndIncluding\":\"9.0.28148.1\",\"matchCriteriaId\":\"1561DCB8-AEAF-45A8-9F6F-EEB6A49452C9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trumpf:tubedesign:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"08.00\",\"versionEndIncluding\":\"14.06.150\",\"matchCriteriaId\":\"D88C313D-95E2-44EA-A895-F4CA659A5846\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:activation_wizard:*:*:*:*:*:moryx:*:*\",\"versionEndIncluding\":\"1.6\",\"matchCriteriaId\":\"E8198A71-1EA7-4DAC-8D4F-EB646A0DC635\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:e-mobility_charging_suite:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.7.0\",\"matchCriteriaId\":\"2B2B109F-41E0-4CC9-9F9F-F1AD06E1EA77\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:fl_network_manager:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"C8751F63-3D03-434A-BF4E-67320F6672FD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:iol-conf:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.7.0\",\"matchCriteriaId\":\"907E5EB3-8346-4371-9CFF-0F885CC0529E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:module_type_package_designer:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.0\",\"matchCriteriaId\":\"C9659319-4AEC-4112-9EAC-7892C0A37AA8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:module_type_package_designer:1.2.0:beta:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB44DD6D-7685-4346-91BC-30CB9531982A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2023.6\",\"matchCriteriaId\":\"170FABD2-23D5-4885-AA09-B4130F945564\"}]}]}],\"references\":[{\"url\":\"https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-030/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-031/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-030/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-031/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert.vde.com/en/advisories/VDE-2023-031/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert.vde.com/en/advisories/VDE-2023-030/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:08:50.775Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-3935\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-26T21:50:55.835781Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-26T20:36:59.547Z\"}}], \"cna\": {\"title\": \"Wibu: Buffer Overflow in CodeMeter Runtime\", \"source\": {\"defect\": [\"CERT@VDE#64566\"], \"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Wibu\", \"product\": \"CodeMeter Runtime\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"7.60b\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Wibu\", \"product\": \"CodeMeter Runtime\", \"versions\": [{\"status\": \"unaffected\", \"version\": \"7.21g\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf\"}, {\"url\": \"https://cert.vde.com/en/advisories/VDE-2023-031/\"}, {\"url\": \"https://cert.vde.com/en/advisories/VDE-2023-030/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787 Out-of-bounds Write\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2023-09-19T07:00:20.911Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-3935\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-27T20:32:53.842Z\", \"dateReserved\": \"2023-07-25T13:02:40.206Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2023-09-13T13:19:18.392Z\", \"assignerShortName\": \"CERTVDE\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
ICSA-23-320-03
Vulnerability from csaf_cisa - Published: 2023-11-14 00:00 - Updated: 2024-08-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo CC family V5.0
Siemens / Desigo CC family V5.0
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V5.1
Siemens / Desigo CC family V5.1
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V6
Siemens / Desigo CC family V6
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON powermanager
Siemens / SENTRON powermanager
|
>=V4.0 |
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo CC family V5.0
Siemens / Desigo CC family V5.0
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V5.1
Siemens / Desigo CC family V5.1
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V6
Siemens / Desigo CC family V6
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON powermanager
Siemens / SENTRON powermanager
|
>=V4.0 |
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo CC family V5.0
Siemens / Desigo CC family V5.0
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V5.1
Siemens / Desigo CC family V5.1
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V6
Siemens / Desigo CC family V6
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V7
Siemens / Desigo CC family V7
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON powermanager
Siemens / SENTRON powermanager
|
>=V4.0 |
Vendor Fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON powermanager, are affected by multiple vulnerabilities in the underlying third-party component WIBU Systems CodeMeter Runtime.\nSuccessful exploitation of these vulnerabilities could allow remote attackers to execute arbitrary code on the Desigo CC server, or create a denial of service condition.\nWhile all Desigo CC version lines V5.0, V5.1 and V6 are affected by all listed vulnerabilities, V7 is only affected by CVE-2023-3935.\n\nSiemens has released a patch to update the CodeMeter Runtime component and recommends to apply the patch on affected systems.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family and SENTRON powermanager - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-625850.json"
},
{
"category": "self",
"summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family and SENTRON powermanager - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-625850.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-320-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-320-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Desigo CC product family",
"tracking": {
"current_release_date": "2024-08-13T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-320-03",
"initial_release_date": "2023-11-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-11-14T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-08-13T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added SENTRON powermanager"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V5.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Desigo CC family V5.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V5.1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Desigo CC family V5.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V6",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Desigo CC family V6"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V7",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Desigo CC family V7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V4.0",
"product": {
"name": "SENTRON powermanager",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SENTRON powermanager"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-20093",
"cwe": {
"id": "CWE-126",
"name": "Buffer Over-read"
},
"notes": [
{
"category": "summary",
"text": "A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.\n\nAn unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005"
]
}
],
"title": "CVE-2021-20093"
},
{
"cve": "CVE-2021-20094",
"cwe": {
"id": "CWE-126",
"name": "Buffer Over-read"
},
"notes": [
{
"category": "summary",
"text": "A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.\n\nAn unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005"
]
}
],
"title": "CVE-2021-20094"
},
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To\r\nexploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege. (WIBU-230704-01)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"title": "CVE-2023-3935"
}
]
}
ICSA-24-004-01
Vulnerability from csaf_cisa - Published: 2024-01-04 07:00 - Updated: 2024-01-04 07:00{
"document": {
"acknowledgments": [
{
"names": [
"an anonymous researcher"
],
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could result in a buffer overflow and allow the attacker to gain full access to the system.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "United States",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploits that specifically target these vulnerabilities have been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-24-004-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-004-01.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-24-004-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-004-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Rockwell Automation FactoryTalk Activation",
"tracking": {
"current_release_date": "2024-01-04T07:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-24-004-01",
"initial_release_date": "2024-01-04T07:00:00.000000Z",
"revision_history": [
{
"date": "2024-01-04T07:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV4.00_Utilizes_Wibu-Systems_CodeMeter_7.60c",
"product": {
"name": "Rockwell Automation Factory Talk Activation Manager: \u003cV4.00_Utilizes_Wibu-Systems_CodeMeter_7.60c",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Factory Talk Activation Manager"
}
],
"category": "vendor",
"name": "Rockwell Automation"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-38545",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Rockwell Automation FactoryTalk Activation Manager and Studio 5000 Logix Designer uses the affected Wibu-Systems\u0027 products which internally use a version of libcurl that is vulnerable to a buffer overflow attack if curl is configured to redirect traffic through a SOCKS5 proxy. A malicious proxy can exploit a bug in the implemented handshake to cause a buffer overflow. If no SOCKS5 proxy has been configured, there is no attack surface.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-38545"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Users of the affected software are encouraged to apply the risk mitigations, if possible:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Upgrade to FactoryTalk Activation Manager 5.01 which has been patched to mitigate these issues.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For information on how to mitigate security risks on industrial automation control systems see our suggested security best practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
},
{
"category": "mitigation",
"details": "Rockwell Automation encourages users to implement their suggested security best practices to minimize risk of the vulnerability.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, please see the security advisory from Rockwell Automation",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.rockwellautomation.com/en-us/company/about-us/sustainability/trust-security/security-advisories.html?sort=pubAsc"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Rockwell Automation FactoryTalk Activation Manager and Studio 5000 Logix Designer uses the affected Wibu-Systems\u0027 products which contain a heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to Version 7.60b that allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system. ",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-3935"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Users of the affected software are encouraged to apply the risk mitigations, if possible:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Upgrade to FactoryTalk Activation Manager 5.01 which has been patched to mitigate these issues.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For information on how to mitigate security risks on industrial automation control systems see our suggested security best practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
},
{
"category": "mitigation",
"details": "Rockwell Automation encourages users to implement their suggested security best practices to minimize risk of the vulnerability.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, please see the security advisory from Rockwell Automation",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.rockwellautomation.com/en-us/company/about-us/sustainability/trust-security/security-advisories.html?sort=pubAsc"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
ICSA-25-182-02
Vulnerability from csaf_cisa - Published: 2023-11-28 07:00 - Updated: 2023-12-05 07:00A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FESTO Festo Automation Suite <= 2.6.0.481
FESTO / Festo Automation Suite
|
<=2.6.0.481 |
Vendor Fix
|
|
|
FESTO FluidDraw P6 <= 6.2k
FESTO / FluidDraw
|
P6_<=6.2k |
Vendor Fix
|
|
|
FESTO FluidDraw 365 <= 7.0a
FESTO / FluidDraw
|
365_<=7.0a |
Vendor Fix
|
|
|
FESTO Didactic CIROS Studio / Education 6.0.0 - 6.4.6
FESTO Didactic / CIROS Studio / Education
|
>=6.0.0|<=6.4.6 |
Vendor Fix
fix
|
|
|
FESTO Didactic FluidSIM 5 all versions
FESTO Didactic / FluidSIM
|
5_all |
Vendor Fix
fix
|
|
|
FESTO Didactic MES-PC shipped before December 2023
FESTO Didactic / MES-PC
|
<shipped_December_2023 |
Vendor Fix
fix
|
|
|
FESTO Didactic CIROS Studio / Education 7.0.0 - 7.1.7
FESTO Didactic / CIROS Studio / Education
|
>=7.0.0|<=7.1.7 |
Vendor Fix
fix
|
|
|
FESTO Didactic FluidSIM 6 <= 6.1c
FESTO Didactic / FluidSIM
|
6_<=6.1c |
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination and support with this publication",
"urls": [
"https://cert.vde.com/"
]
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "general",
"text": "Users running communication over an untrusted network who require full protection should switch to an alternative solution such as running the communication over a VPN.\n\nFesto strongly recommends to minimize and protect network access to connected devices with state of the art techniques and processes. \n\nAs part of a security strategy, Festo recommends the following general defense measures to reduce the risk of exploits: \n- Use devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside \n- Use firewalls to protect and separate the control system network from other networks \n- Use VPN (Virtual Private Networks) tunnels if remote access is required \n- Activate and apply user management and password features \n- Use encrypted communication links \n- Limit the access to both development and control system by physical means, operating system features, etc. \n- Protect both development and control system by using up to date virus detecting solutions",
"title": "General recomendation"
},
{
"category": "summary",
"text": "A vulnerability in the Wibu CodeMeter Runtime, which is part of the installation packages of several Festo products, was found. An attacker exploiting the vulnerability in WIBU CodeMeter Runtime in server mode could gain full access to the affected server via network access without any user interaction. This could lead to remote code execution and escalation of privileges giving full admin access on the host system for an already authenticated user (logged in locally to the PC).",
"title": "Summary"
},
{
"category": "legal_disclaimer",
"text": "Festo assumes no liability whatsoever for indirect, collateral, accidental or consequential losses that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided free of charge and on good faith by Festo. Insofar as permissible by law, however, none of this information shall establish any warranty, guarantee, commitment or liability on the part of Festo. Note: In no case does these information release the operator or responsible person from the obligation to check the effect on his system or installation before using the information and, in the event of negative consequences, not to use the information.\n\nIn addition, the actual general terms and conditions of Festo for delivery, payment and software use shall apply, available under http://www.festo.com.",
"title": "Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Festo SE \u0026 Co. KG fsa-202305 from a direct conversion of their vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Festo SE \u0026 Co. KG directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-182-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-182-02.json"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories",
"url": "https://cert.vde.com/en/advisories/vendor/festo/"
},
{
"category": "external",
"summary": "For further security-related issues in Festo products please contact the Festo Product Security Incident Response Team (PSIRT)",
"url": "https://festo.com/psirt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-182-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "FESTO Automation Suite, FluidDraw, and Festo Didactic Products",
"tracking": {
"aliases": [
"VDE-2023-036"
],
"current_release_date": "2023-12-05T07:00:00.000000Z",
"generator": {
"date": "2025-07-01T15:37:43.746271Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-182-02",
"initial_release_date": "2023-11-28T07:00:00.000000Z",
"revision_history": [
{
"date": "2023-11-28T07:00:00.000000Z",
"number": "1.0.0",
"summary": "Initial version"
},
{
"date": "2023-12-05T08:00:00.000000Z",
"number": "1.1.0",
"summary": "Removed \u0027MES4 (v3)\u0027, \u0027MES4 (\u003c=v2)\u0027 and \u0027Energy-PC\u0027 from affected products as they do not install WIBU CodeMeter Runtime."
}
],
"status": "final",
"version": "1.1.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.6.0.481",
"product": {
"name": "FESTO Festo Automation Suite \u003c= 2.6.0.481",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"x_generic_uris": [
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:FestoAutomationSuite"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8074657"
}
]
}
}
}
],
"category": "product_name",
"name": "Festo Automation Suite"
},
{
"branches": [
{
"category": "product_version_range",
"name": "P6_\u003c=6.2k",
"product": {
"name": "FESTO FluidDraw P6 \u003c= 6.2k",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"x_generic_uris": [
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:FluidDraw"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8085496"
}
]
}
}
},
{
"category": "product_version_range",
"name": "365_\u003c=7.0a",
"product": {
"name": "FESTO FluidDraw 365 \u003c= 7.0a",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"x_generic_uris": [
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:FluidDraw"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8085497"
}
]
}
}
}
],
"category": "product_name",
"name": "FluidDraw"
}
],
"category": "vendor",
"name": "FESTO"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=6.0.0|\u003c=6.4.6",
"product": {
"name": "FESTO Didactic CIROS Studio / Education 6.0.0 - 6.4.6",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8038980"
}
]
}
}
},
{
"category": "product_version_range",
"name": "\u003e=7.0.0|\u003c=7.1.7",
"product": {
"name": "FESTO Didactic CIROS Studio / Education 7.0.0 - 7.1.7",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8140772"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8140773"
}
]
}
}
}
],
"category": "product_name",
"name": "CIROS Studio / Education"
},
{
"branches": [
{
"category": "product_version_range",
"name": "5_all",
"product": {
"name": "FESTO Didactic FluidSIM 5 all versions",
"product_id": "CSAFPID-0006"
}
},
{
"category": "product_version_range",
"name": "6_\u003c=6.1c",
"product": {
"name": "FESTO Didactic FluidSIM 6 \u003c= 6.1c",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8148657"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8148658"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8148659"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8148812"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8148813"
},
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8148814"
}
]
}
}
}
],
"category": "product_name",
"name": "FluidSIM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cshipped_December_2023",
"product": {
"name": "FESTO Didactic MES-PC shipped before December 2023",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "MES-PC"
}
],
"category": "vendor",
"name": "FESTO Didactic"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system."
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0005",
"CSAFPID-0007"
]
},
"remediations": [
{
"category": "vendor_fix",
"date": "2023-08-14T10:00:00.000000Z",
"details": "Update CodeMeter Runtime to version \u003e= 7.60c\nThe latest version of CodeMeter Runtime can be downloaded from WIBU System\u0027s web site.",
"product_ids": [
"CSAFPID-0004",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0005",
"CSAFPID-0008"
],
"url": "https://www.wibu.com/support/user/user-software.html"
},
{
"category": "vendor_fix",
"date": "2024-10-07T10:00:00.000000Z",
"details": "Planned Fix in Summer Release 2024",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to the latest version.",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0001"
]
},
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"availabilityRequirement": "LOW",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"confidentialityRequirement": "LOW",
"environmentalScore": 8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"integrityRequirement": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/CR:L/IR:L/AR:L",
"version": "3.1"
},
"products": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0008"
]
}
],
"title": "CVE-2023-3935"
}
]
}
ICSA-26-076-01
Vulnerability from csaf_cisa - Published: 2026-02-26 08:00 - Updated: 2026-03-17 06:00An unauthenticated remote attacker can bypass the user management in CODESYS Visualization and read visualization template files or static elements by means of forced browsing.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Untrusted search path vulnerability in the pthread_win32_process_attach_np function in pthreadGC2.dll in Pthreads-win32 2.8.0 allows local users to gain privileges via a Trojan horse quserex.dll file in the current working directory. NOTE: some of these details are obtained from third party information.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Constructed ASN.1 types with a recursive definition (such as can be found in PKCS7) could eventually exceed the stack given malicious input with excessive recursion. This could result in a Denial Of Service attack. There are no such structures used within SSL/TLS that come from untrusted sources so this is considered safe. Fixed in OpenSSL 1.1.0h (Affected 1.1.0-1.1.0g). Fixed in OpenSSL 1.0.2o (Affected 1.0.2b-1.0.2n).
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System).
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), an attacker can identify valid usernames.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user's password may be changed by an attacker without knowledge of the current password.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Inadequate Encryption Strength in CODESYS Development System V3 versions prior to V3.5.18.40 allows an unauthenticated local attacker to access and manipulate code of the encrypted boot application.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into memory which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple CODESYS products in multiple versions an unauthorized, remote attacker may use a improper input validation vulnerability to read from invalid addresses leading to a denial of service.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a improper input validation vulnerability in the CmpApp/CmpAppBP/CmpAppForce Components of multiple CODESYS products in multiple versions to read from an invalid address which can lead to a denial-of-service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated, remote attacker may use a Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in multiple versions of multiple CODESYS products to force a denial-of-service situation.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context .
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog.
CWE-307 - Improper Restriction of Excessive Authentication Attempts| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In CODESYS Development System 3.5.9.0 to 3.5.17.0 and CODESYS Scripting 4.0.0.0 to 4.1.0.0 unsafe directory permissions would allow an attacker with local access to the workstation to place potentially harmful and disguised scripts that could be executed by legitimate users.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unauthenticated local attacker may trick a user to open corrupted project files to crash the system due to use after free vulnerability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
In jQuery versions greater than or equal to 1.0.3 and before 3.5.0, passing HTML containing <option> elements from untrusted sources - even after sanitizing it - to one of jQuery's DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code. This problem is patched in jQuery 3.5.0.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0008 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-0007 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0009 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0010 | — |
Mitigation
|
|
| Unresolved product id: CSAFPID-0011 | — |
Mitigation
|
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination and support with this publication",
"urls": [
"https://certvde.com"
]
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
"text": "Critical"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.\n\nThis change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.\n\nPlease ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.",
"title": "Summary"
},
{
"category": "description",
"text": "The vulnerabilities covered by this advisory have a broad range of impacts ranging from denial-of-service to disclosure or manipulation/deletion of information.",
"title": "Impact"
},
{
"category": "description",
"text": "Download and install Festo Automation Suite version 2.8.0.138 and download the latest, patched version of Codesys directly from the official Codesys website.\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\nRegularly monitor Codesys security advisories and apply updates promptly.\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"title": "Remediation"
},
{
"category": "general",
"text": "As part of a security strategy, Festo recommends the following general defense measures to reduce the risk of exploits: \n- Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from outside.\n- Use firewalls to protect and separate the control system network from other networks.\n- Use VPN (Virtual Private Networks) tunnels if remote access is required.\n- Activate and apply user management and password features.\n- Use encrypted communication links.\n- Limit the access to both development and control system by physical means, operating system features, etc. \n- Protect both development and control systems by using up-to-date virus detection solutions.\n\nFesto strongly recommends minimizing and protecting network access to connected devices with state-of-the-art techniques and processes. \nTo ensure secure operation follow the recommendations in the product manuals.",
"title": "General recommendations"
},
{
"category": "legal_disclaimer",
"text": "Festo assumes no liability whatsoever for indirect, collateral, accidental or consequential losses that occur by the distribution and/or use of this document or any losses in connection with the distribution and/or use of this document. All information published in this document is provided free of charge and on good faith by Festo. Insofar as permissible by law, however, none of this information shall establish any warranty, guarantee, commitment, or liability on the part of Festo.\n\nNote: In no case does this information release the operator or responsible person from the obligation to check the effect on his system or installation before using the information and, in the event of negative consequences, not to use the information.\n\nIn addition, the actual general terms, and conditions for delivery, payment and software use of Festo, available under http://www.festo.com and the special provisions for the use of Festo Security Advisory available at https://www.festo.com/psirt shall apply.",
"title": "Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Festo SE \u0026 Co. KG FSA-202601 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Festo SE \u0026 Co. KG directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF",
"url": "https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories",
"url": "https://certvde.com/en/advisories/vendor/festo/"
},
{
"category": "external",
"summary": "For further security-related issues in Festo products please contact the Festo Product Security Incident Response Team (PSIRT)",
"url": "https://www.festo.com/psirt"
},
{
"category": "self",
"summary": "FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML",
"url": "https://certvde.com/en/advisories/VDE-2025-108"
},
{
"category": "external",
"summary": "https://nvd.nist.gov/vuln/detail/CVE-2025-2595",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2595"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-076-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-076-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-076-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "CODESYS in Festo Automation Suite",
"tracking": {
"aliases": [
"VDE-2025-108"
],
"current_release_date": "2026-03-17T06:00:00.000000Z",
"generator": {
"date": "2026-03-12T21:34:19.682905Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-26-076-01",
"initial_release_date": "2026-02-26T08:00:00.000000Z",
"revision_history": [
{
"date": "2026-02-26T08:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial version"
},
{
"date": "2026-03-17T06:00:00.000000Z",
"legacy_version": "CISA Republication",
"number": "2",
"summary": "Initial CISA Republication of Festo SE \u0026 Co. KG FSA-202601 advisory"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003c2.8.0.138",
"product": {
"name": "Festo Automation Suite \u003c2.8.0.138",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"8074657"
],
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8074657"
},
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Website",
"uri": "https://www.festo.com/us/en/a/8074657/?q=8074657%7E%3AfestoSortOrderScored"
}
]
}
}
},
{
"category": "product_version",
"name": "2.8.0.138",
"product": {
"name": "Festo Automation Suite 2.8.0.138",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"cpe": "cpe:2.3:a:festo:festo_automation_suite:2.8.0.138*:*:*:*:*:*:*:*",
"model_numbers": [
"8074657"
],
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Partnumber:8074657"
},
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Website",
"uri": "https://www.festo.com/us/en/a/8074657/?q=8074657%7E%3AfestoSortOrderScored"
}
]
}
}
},
{
"category": "product_version",
"name": "2.8.0.137",
"product": {
"name": "Festo Automation Suite 2.8.0.137",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"cpe": "cpe:2.3:a:festo:festo_automation_suite:2.8.0.138*:*:*:*:*:*:*:*",
"model_numbers": [
"8074657"
],
"x_generic_uris": [
{
"namespace": "Festo:Partnumber",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Ordercode",
"uri": "Festo:Ordercode:8074657"
},
{
"namespace": "Festo:Wesite",
"uri": "https://www.festo.com/us/en/a/8074657/?q=8074657%7E%3AfestoSortOrderScored"
}
]
}
}
}
],
"category": "product_name",
"name": "Festo Automation Suite"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "FESTO"
},
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "3.5.21.20",
"product": {
"name": "CODESYS Development System 3.5.21.20",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.21.20*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version",
"name": "3.0",
"product": {
"name": "CODESYS Development System 3.0",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version",
"name": "3.5.16.10",
"product": {
"name": "CODESYS Development System 3.5.16.10",
"product_id": "CSAFPID-0006",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*"
}
}
}
],
"category": "product_name",
"name": "CODESYS Development System"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "CODESYS"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
],
"summary": "Affected Products."
}
],
"relationships": [
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite \u003c2.8.0.138 installed with CODESYS Development System 3.0",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-0001",
"relates_to_product_reference": "CSAFPID-0005"
},
{
"category": "external_component_of",
"full_product_name": {
"name": "CODESYS Development System 3.5.21.20 external component of Festo Automation Suite 2.8.0.138",
"product_id": "CSAFPID-0008",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.21.20*:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-0004",
"relates_to_product_reference": "CSAFPID-0002"
},
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite \u003c2.8.0.138 installed with CODESYS Development System 3.5.16.10",
"product_id": "CSAFPID-0009",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-0001",
"relates_to_product_reference": "CSAFPID-0006"
},
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite 2.8.0.137 installed with CODESYS Development System 3.0",
"product_id": "CSAFPID-0010",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-0003",
"relates_to_product_reference": "CSAFPID-0005"
},
{
"category": "installed_with",
"full_product_name": {
"name": "Festo Automation Suite 2.8.0.137 installed with CODESYS Development System 3.5.16.10",
"product_id": "CSAFPID-0011",
"product_identification_helper": {
"cpe": "cpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*"
}
},
"product_reference": "CSAFPID-0003",
"relates_to_product_reference": "CSAFPID-0006"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-2595",
"cwe": {
"id": "CWE-425",
"name": "Direct Request (\u0027Forced Browsing\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can bypass the user management in CODESYS Visualization and read visualization template files or static elements by means of forced browsing.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2595"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/425.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\n\nDownload the latest, patched version of Codesys directly from the official Codesys website.\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\nRegularly monitor Codesys security advisories and apply updates promptly.\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2025-2595"
},
{
"cve": "CVE-2010-5250",
"cwe": {
"id": "CWE-426",
"name": "Untrusted Search Path"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Untrusted search path vulnerability in the pthread_win32_process_attach_np function in pthreadGC2.dll in Pthreads-win32 2.8.0 allows local users to gain privileges via a Trojan horse quserex.dll file in the current working directory. NOTE: some of these details are obtained from third party information.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2010-5250"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/426.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v2": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"environmentalScore": 6.9,
"integrityImpact": "COMPLETE",
"temporalScore": 6.9,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2010-5250"
},
{
"cve": "CVE-2017-3735",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-3735"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2017-3735"
},
{
"cve": "CVE-2018-0739",
"cwe": {
"id": "CWE-674",
"name": "Uncontrolled Recursion"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Constructed ASN.1 types with a recursive definition (such as can be found in PKCS7) could eventually exceed the stack given malicious input with excessive recursion. This could result in a Denial Of Service attack. There are no such structures used within SSL/TLS that come from untrusted sources so this is considered safe. Fixed in OpenSSL 1.1.0h (Affected 1.1.0-1.1.0g). Fixed in OpenSSL 1.0.2o (Affected 1.0.2b-1.0.2n).",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-0739"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/674.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2018-0739"
},
{
"cve": "CVE-2018-10612",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-10612"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/284.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2018-10612"
},
{
"cve": "CVE-2018-20025",
"cwe": {
"id": "CWE-330",
"name": "Use of Insufficiently Random Values"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20025"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/330.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2018-20025"
},
{
"cve": "CVE-2018-20026",
"cwe": {
"id": "CWE-923",
"name": "Improper Restriction of Communication Channel to Intended Endpoints"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20026"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/923.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2018-20026"
},
{
"cve": "CVE-2019-13532",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13532"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/22.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-13532"
},
{
"cve": "CVE-2019-13538",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13538"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/79.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.6,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 8.6,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-13538"
},
{
"cve": "CVE-2019-13542",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13542"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-13542"
},
{
"cve": "CVE-2019-13548",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13548"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/121.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-13548"
},
{
"cve": "CVE-2019-18858",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18858"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-18858"
},
{
"cve": "CVE-2019-19789",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19789"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-19789"
},
{
"cve": "CVE-2019-5105",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System).",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-5105"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-5105"
},
{
"cve": "CVE-2019-9008",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9008"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/732.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-9008"
},
{
"cve": "CVE-2019-9009",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9009"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/755.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-9009"
},
{
"cve": "CVE-2019-9010",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9010"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/284.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-9010"
},
{
"cve": "CVE-2019-9011",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), an attacker can identify valid usernames.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9011"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/668.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-9011"
},
{
"cve": "CVE-2019-9012",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9012"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-9012"
},
{
"cve": "CVE-2019-9013",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-9013"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/327.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2019-9013"
},
{
"cve": "CVE-2020-10245",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10245"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-10245"
},
{
"cve": "CVE-2020-12067",
"cwe": {
"id": "CWE-640",
"name": "Weak Password Recovery Mechanism for Forgotten Password"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user\u0027s password may be changed by an attacker without knowledge of the current password.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12067"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/640.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-12067"
},
{
"cve": "CVE-2020-12068",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12068"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/269.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-12068"
},
{
"cve": "CVE-2020-12069",
"cwe": {
"id": "CWE-916",
"name": "Use of Password Hash With Insufficient Computational Effort"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12069"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/916.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-12069"
},
{
"cve": "CVE-2020-14509",
"cwe": {
"id": "CWE-805",
"name": "Buffer Access with Incorrect Length Value"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14509"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/805.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-14509"
},
{
"cve": "CVE-2020-14513",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14513"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-14513"
},
{
"cve": "CVE-2020-14515",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14515"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/347.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-14515"
},
{
"cve": "CVE-2020-14517",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14517"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/326.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-14517"
},
{
"cve": "CVE-2020-14519",
"cwe": {
"id": "CWE-346",
"name": "Origin Validation Error"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14519"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/346.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-14519"
},
{
"cve": "CVE-2020-15806",
"cwe": {
"id": "CWE-401",
"name": "Missing Release of Memory after Effective Lifetime"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15806"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/401.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-15806"
},
{
"cve": "CVE-2020-16233",
"cwe": {
"id": "CWE-404",
"name": "Improper Resource Shutdown or Release"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-16233"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/404.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-16233"
},
{
"cve": "CVE-2020-7052",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7052"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-7052"
},
{
"cve": "CVE-2021-21863",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21863"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/502.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21863"
},
{
"cve": "CVE-2021-21864",
"cwe": {
"id": "CWE-50",
"name": "Path Equivalence: \u0027//multiple/leading/slash\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21864"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/50.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21864"
},
{
"cve": "CVE-2021-21865",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21865"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/502.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21865"
},
{
"cve": "CVE-2021-21866",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21866"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/502.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21866"
},
{
"cve": "CVE-2021-21867",
"cwe": {
"id": "CWE-50",
"name": "Path Equivalence: \u0027//multiple/leading/slash\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21867"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/50.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21867"
},
{
"cve": "CVE-2021-21868",
"cwe": {
"id": "CWE-50",
"name": "Path Equivalence: \u0027//multiple/leading/slash\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21868"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/50.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21868"
},
{
"cve": "CVE-2021-21869",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21869"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/502.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-21869"
},
{
"cve": "CVE-2021-29239",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29239"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/345.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-29239"
},
{
"cve": "CVE-2021-29240",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/345.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-29240"
},
{
"cve": "CVE-2021-29241",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-29241"
},
{
"cve": "CVE-2021-29242",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29242"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-29242"
},
{
"cve": "CVE-2021-30186",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30186"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-30186"
},
{
"cve": "CVE-2021-30187",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30187"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-30187"
},
{
"cve": "CVE-2021-30188",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30188"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-30188"
},
{
"cve": "CVE-2021-30190",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30190"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/306.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-30190"
},
{
"cve": "CVE-2021-30195",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30195"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/125.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-30195"
},
{
"cve": "CVE-2021-33485",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33485"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-33485"
},
{
"cve": "CVE-2021-33486",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33486"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/755.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-33486"
},
{
"cve": "CVE-2021-34593",
"cwe": {
"id": "CWE-75",
"name": "Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34593"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/75.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-34593"
},
{
"cve": "CVE-2021-34595",
"cwe": {
"id": "CWE-823",
"name": "Use of Out-of-range Pointer Offset"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34595"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/823.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-34595"
},
{
"cve": "CVE-2021-34596",
"cwe": {
"id": "CWE-82",
"name": "Improper Neutralization of Script in Attributes of IMG Tags in a Web Page"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34596"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/82.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-34596"
},
{
"cve": "CVE-2021-36763",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-36763"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/552.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-36763"
},
{
"cve": "CVE-2021-36764",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-36764"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-36764"
},
{
"cve": "CVE-2021-36765",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-36765"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2021-36765"
},
{
"cve": "CVE-2022-1965",
"cwe": {
"id": "CWE-755",
"name": "Improper Handling of Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1965"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/755.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-1965"
},
{
"cve": "CVE-2022-1989",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1989"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-1989"
},
{
"cve": "CVE-2022-22508",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22508"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 4.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 4.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22508"
},
{
"cve": "CVE-2022-22513",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22513"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22513"
},
{
"cve": "CVE-2022-22514",
"cwe": {
"id": "CWE-822",
"name": "Untrusted Pointer Dereference"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22514"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/822.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22514"
},
{
"cve": "CVE-2022-22515",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22515"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/668.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22515"
},
{
"cve": "CVE-2022-22516",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22516"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/732.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22516"
},
{
"cve": "CVE-2022-22517",
"cwe": {
"id": "CWE-33",
"name": "Path Traversal: \u0027....\u0027 (Multiple Dot)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22517"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/33.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22517"
},
{
"cve": "CVE-2022-22519",
"cwe": {
"id": "CWE-12",
"name": "ASP.NET Misconfiguration: Missing Custom Error Page"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22519"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/12.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-22519"
},
{
"cve": "CVE-2022-30791",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30791"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/400.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-30791"
},
{
"cve": "CVE-2022-30792",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30792"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/400.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-30792"
},
{
"cve": "CVE-2022-31805",
"cwe": {
"id": "CWE-523",
"name": "Unprotected Transport of Credentials"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31805"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/523.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-31805"
},
{
"cve": "CVE-2022-31806",
"cwe": {
"id": "CWE-1188",
"name": "Initialization of a Resource with an Insecure Default"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31806"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/1188.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-31806"
},
{
"cve": "CVE-2022-32136",
"cwe": {
"id": "CWE-82",
"name": "Improper Neutralization of Script in Attributes of IMG Tags in a Web Page"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32136"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/82.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32136"
},
{
"cve": "CVE-2022-32137",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32137"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/122.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32137"
},
{
"cve": "CVE-2022-32138",
"cwe": {
"id": "CWE-194",
"name": "Unexpected Sign Extension"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32138"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/194.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32138"
},
{
"cve": "CVE-2022-32139",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32139"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/125.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32139"
},
{
"cve": "CVE-2022-32140",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32140"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32140"
},
{
"cve": "CVE-2022-32141",
"cwe": {
"id": "CWE-126",
"name": "Buffer Over-read"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32141"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/126.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32141"
},
{
"cve": "CVE-2022-32142",
"cwe": {
"id": "CWE-823",
"name": "Use of Out-of-range Pointer Offset"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32142"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/823.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.1,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.1,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32142"
},
{
"cve": "CVE-2022-32143",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32143"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/552.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-32143"
},
{
"cve": "CVE-2022-4046",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4046"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-4046"
},
{
"cve": "CVE-2022-4048",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Inadequate Encryption Strength in CODESYS Development System V3 versions prior to V3.5.18.40 allows an unauthenticated local attacker to access and manipulate code of the encrypted boot application.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4048"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/326.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.7,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.7,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-4048"
},
{
"cve": "CVE-2022-4224",
"cwe": {
"id": "CWE-1188",
"name": "Initialization of a Resource with an Insecure Default"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4224"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/1188.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-4224"
},
{
"cve": "CVE-2022-47378",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47378"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47378"
},
{
"cve": "CVE-2022-47379",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into memory which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47379"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47379"
},
{
"cve": "CVE-2022-47380",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47380"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47380"
},
{
"cve": "CVE-2022-47381",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47381"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47381"
},
{
"cve": "CVE-2022-47383",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47383"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47383"
},
{
"cve": "CVE-2022-47384",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47384"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47384"
},
{
"cve": "CVE-2022-47385",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47385"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47385"
},
{
"cve": "CVE-2022-47386",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47386"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47386"
},
{
"cve": "CVE-2022-47387",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47387"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47387"
},
{
"cve": "CVE-2022-47388",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47388"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47388"
},
{
"cve": "CVE-2022-47389",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47389"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47389"
},
{
"cve": "CVE-2022-47390",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47390"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47390"
},
{
"cve": "CVE-2022-47391",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple CODESYS products in multiple versions an unauthorized, remote attacker may use a improper input validation vulnerability to read from invalid addresses leading to a denial of service.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47391"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47391"
},
{
"cve": "CVE-2022-47392",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a improper input validation vulnerability in the CmpApp/CmpAppBP/CmpAppForce Components of multiple CODESYS products in multiple versions to read from an invalid address which can lead to a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47392"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47392"
},
{
"cve": "CVE-2022-47393",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated, remote attacker may use a Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in multiple versions of multiple CODESYS products to force a denial-of-service situation.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47393"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47393"
},
{
"cve": "CVE-2023-3662",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context .",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3662"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/427.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-3662"
},
{
"cve": "CVE-2023-3663",
"cwe": {
"id": "CWE-940",
"name": "Improper Verification of Source of a Communication Channel"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3663"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/940.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-3663"
},
{
"cve": "CVE-2023-3669",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3669"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/307.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"environmentalScore": 3.3,
"environmentalSeverity": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 3.3,
"temporalSeverity": "LOW",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-3669"
},
{
"cve": "CVE-2023-3670",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In CODESYS Development System 3.5.9.0 to 3.5.17.0 and CODESYS Scripting 4.0.0.0 to 4.1.0.0 unsafe directory permissions would allow an attacker with local access to the workstation to place potentially harmful and disguised scripts that could be executed by legitimate users.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3670"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/668.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.3,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-3670"
},
{
"cve": "CVE-2023-37545",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37545"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37545"
},
{
"cve": "CVE-2023-37546",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37546"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37546"
},
{
"cve": "CVE-2023-37547",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37547"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37547"
},
{
"cve": "CVE-2023-37548",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37548"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37548"
},
{
"cve": "CVE-2023-37549",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37549"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37549"
},
{
"cve": "CVE-2023-37550",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37550"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37550"
},
{
"cve": "CVE-2023-37551",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37551"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/552.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37551"
},
{
"cve": "CVE-2023-37552",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37552"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37552"
},
{
"cve": "CVE-2023-37553",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37553"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37553"
},
{
"cve": "CVE-2023-37554",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37554"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37554"
},
{
"cve": "CVE-2023-37555",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37555"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37555"
},
{
"cve": "CVE-2023-37556",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37556"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37556"
},
{
"cve": "CVE-2023-37557",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37557"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37557"
},
{
"cve": "CVE-2023-37558",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37558"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37558"
},
{
"cve": "CVE-2023-37559",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37559"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-37559"
},
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3935"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-3935"
},
{
"cve": "CVE-2023-49675",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability.\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49675"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-49675"
},
{
"cve": "CVE-2023-49676",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated local attacker may trick a user to open corrupted project files to crash the system due to use after free vulnerability.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49676"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/416.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-49676"
},
{
"cve": "CVE-2023-6357",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6357"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2023-6357"
},
{
"cve": "CVE-2024-5000",
"cwe": {
"id": "CWE-13",
"name": "ASP.NET Misconfiguration: Password in Configuration File"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\r\n\r\n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-5000"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/13.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2024-5000"
},
{
"cve": "CVE-2024-8175",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8175"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/754.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2024-8175"
},
{
"cve": "CVE-2025-0694",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-0694"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/22.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.6,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.6,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2025-0694"
},
{
"cve": "CVE-2025-1468",
"cwe": {
"id": "CWE-203",
"name": "Observable Discrepancy"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-1468"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/203.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2025-1468"
},
{
"cve": "CVE-2025-41658",
"cwe": {
"id": "CWE-276",
"name": "Incorrect Default Permissions"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-41658"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/276.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 5.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 5.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2025-41658"
},
{
"cve": "CVE-2025-41659",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-41659"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/732.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.3,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.3,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2025-41659"
},
{
"cve": "CVE-2020-11023",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "In jQuery versions greater than or equal to 1.0.3 and before 3.5.0, passing HTML containing \u003coption\u003e elements from untrusted sources - even after sanitizing it - to one of jQuery\u0027s DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code. This problem is patched in jQuery 3.5.0.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11023"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/79.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.9,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 6.9,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2020-11023"
},
{
"cve": "CVE-2022-47382",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0008"
],
"known_affected": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47382"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to:\r\n\r\nDownload the latest, patched version of Codesys directly from the official Codesys website.\r\nFollow the installation and update instructions provided by Codesys to ensure all security fixes are applied.\r\nRegularly monitor Codesys security advisories and apply updates promptly.\r\nMaintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.",
"product_ids": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011"
]
}
],
"title": "CVE-2022-47382"
}
]
}
SCA-2023-0009
Vulnerability from csaf_sick - Published: 2023-09-29 10:00 - Updated: 2023-09-29 10:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SICK SIM2000ST-E >=1.8.0
SICK AG / SIM / SIM2000ST-E
|
11123451117588
|
>=1.8.0 |
Mitigation
fix
|
|
SICK AppEngine x86 all versions
SICK AG / AppEngine / AppEngine
|
1613796
|
vers:all/* |
Mitigation
fix
Vendor Fix
fix
|
|
SICK TDC-E >=FW L4M 2022.4
SICK AG / TDC-E / TDC-E
|
60703446079357
|
>=FW L4M 2022.4 |
Mitigation
fix
|
|
SICK LiDAR-LOC <2.4.1
SICK AG / LiDAR-Lokalisierung / LiDAR-LOC
|
11227521122751
|
<2.4.1 |
Mitigation
fix
Vendor Fix
|
|
SICK CODE-LOC <2.4.1
SICK AG / LiDAR-Lokalisierung / CODE-LOC
|
1132922
|
<2.4.1 |
Mitigation
fix
Vendor Fix
|
|
SICK FlowGate all versions
SICK AG / FlowGate / FlowGate
|
vers:all/* |
Mitigation
fix
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "As general security measures, SICK recommends to minimize network exposure of the devices, restrict network access and follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Security Measures"
},
{
"category": "general",
"text": "SICK performs vulnerability classification by using the CVSS scoring system (*CVSS v3.1*). The environmental score is dependent on the customer\u2019s environment and can affect the overall CVSS score. SICK recommends that customers individually evaluate the environmental score to achieve final scoring.",
"title": "Vulnerability Classification"
},
{
"category": "summary",
"text": "Wibu-Systems disclosed a security vulnerability in the CodeMeter Runtime. There is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to Wibu-Systems.\nTo exploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server.\nIf CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter."
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@sick.de",
"issuing_authority": "SICK AG issues and issues in EHS products (when related to the Endress+Hauser SICK (EHS) joint venture).",
"name": "SICK PSIRT",
"namespace": "https://www.sick.com/psirt"
},
"references": [
{
"summary": "SICK PSIRT Security Advisories",
"url": "https://www.sick.com/psirt"
},
{
"summary": "SICK Operating Guidelines",
"url": "https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf"
},
{
"summary": "ICS-CERT recommended practices on Industrial Security",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"summary": "CVSS v3.1 Calculator",
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"category": "self",
"summary": "The canonical URL.",
"url": "https://www.sick.com/.well-known/csaf/white/2023/sca-2023-0009.json"
},
{
"category": "self",
"summary": "The canonical PDF URL.",
"url": "https://www.sick.com/.well-known/csaf/white/2023/sca-2023-0009.pdf"
}
],
"title": "Vulnerability in Wibu-Systems CodeMeter Runtime affects multiple SICK products",
"tracking": {
"current_release_date": "2023-09-29T10:00:00.000Z",
"generator": {
"date": "2023-12-04T10:36:43.371Z",
"engine": {
"name": "Secvisogram",
"version": "2.2.16"
}
},
"id": "SCA-2023-0009",
"initial_release_date": "2023-09-29T10:00:00.000Z",
"revision_history": [
{
"date": "2023-09-29T10:00:00.000Z",
"number": "1",
"summary": "Initial Release"
},
{
"date": "2023-10-06T10:00:00.000Z",
"number": "2",
"summary": "Updated fixed version of LiDAR-LOC."
},
{
"date": "2023-12-04T11:00:00.000Z",
"number": "3",
"summary": "Added self reference in CSAF"
},
{
"date": "2025-07-30T07:30:00.000Z",
"number": "4",
"summary": "Updated Advisory: URL for SICK Operating Guidelines has been updated"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=1.8.0",
"product": {
"name": "SICK SIM2000ST-E \u003e=1.8.0",
"product_id": "CSAFPID-0016",
"product_identification_helper": {
"skus": [
"1112345",
"1117588"
]
}
}
}
],
"category": "product_name",
"name": "SIM2000ST-E"
}
],
"category": "product_family",
"name": "SIM"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICK AppEngine x86 all versions",
"product_id": "CSAFPID-0017",
"product_identification_helper": {
"skus": [
"1613796"
]
}
}
}
],
"category": "product_name",
"name": "AppEngine"
}
],
"category": "product_family",
"name": "AppEngine"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=FW L4M 2022.4",
"product": {
"name": "SICK TDC-E \u003e=FW L4M 2022.4",
"product_id": "CSAFPID-0018",
"product_identification_helper": {
"skus": [
"6070344",
"6079357"
]
}
}
}
],
"category": "product_name",
"name": "TDC-E"
}
],
"category": "product_family",
"name": "TDC-E"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.4.1",
"product": {
"name": "SICK LiDAR-LOC \u003c2.4.1",
"product_id": "CSAFPID-0019",
"product_identification_helper": {
"skus": [
"1122752",
"1122751"
]
}
}
}
],
"category": "product_name",
"name": "LiDAR-LOC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.4.1",
"product": {
"name": "SICK CODE-LOC \u003c2.4.1",
"product_id": "CSAFPID-0020",
"product_identification_helper": {
"skus": [
"1132922"
]
}
}
}
],
"category": "product_name",
"name": "CODE-LOC"
}
],
"category": "product_family",
"name": "LiDAR-Lokalisierung"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICK FlowGate all versions",
"product_id": "CSAFPID-0021"
}
}
],
"category": "product_name",
"name": "FlowGate"
}
],
"category": "product_family",
"name": "FlowGate"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=1.8.0",
"product": {
"name": "SICK SIM2000ST-E Firmware \u003e1.8.0",
"product_id": "CSAFPID-0022"
}
}
],
"category": "product_name",
"name": "SIM2000ST-E Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICK AppEngine Firmware all versions",
"product_id": "CSAFPID-0023"
}
}
],
"category": "product_name",
"name": "AppEngine Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=FW L4M 2022.4",
"product": {
"name": "SICK TDC-E Firmware \u003e=FW L4M 2022.4",
"product_id": "CSAFPID-0024"
}
}
],
"category": "product_name",
"name": "TDC-E Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICK LiDAR-LOC Firmware all versions",
"product_id": "CSAFPID-0025"
}
}
],
"category": "product_name",
"name": "LiDAR-LOC Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICK CODE-LOC Firmware all versions",
"product_id": "CSAFPID-0026"
}
}
],
"category": "product_name",
"name": "CODE-LOC Firmware"
}
],
"category": "vendor",
"name": "SICK AG"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "SICK SIM2000ST-E all Firmware versions",
"product_id": "CSAFPID-0027"
},
"product_reference": "CSAFPID-0022",
"relates_to_product_reference": "CSAFPID-0016"
},
{
"category": "installed_on",
"full_product_name": {
"name": "SICK AppEngine all Firmware versions",
"product_id": "CSAFPID-0028"
},
"product_reference": "CSAFPID-0023",
"relates_to_product_reference": "CSAFPID-0017"
},
{
"category": "installed_on",
"full_product_name": {
"name": "SICK TDC-E \u003c=FW L4M 2022.3 with Firmware \u003c=FW L4M 2022.3",
"product_id": "CSAFPID-0029"
},
"product_reference": "CSAFPID-0024",
"relates_to_product_reference": "CSAFPID-0018"
},
{
"category": "installed_on",
"full_product_name": {
"name": "SICK LiDAR-LOC all Firmware versions",
"product_id": "CSAFPID-0030"
},
"product_reference": "CSAFPID-0025",
"relates_to_product_reference": "CSAFPID-0019"
},
{
"category": "installed_on",
"full_product_name": {
"name": "SICK CODE-LOC all Firmware versions",
"product_id": "CSAFPID-0031"
},
"product_reference": "CSAFPID-0026",
"relates_to_product_reference": "CSAFPID-0020"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To exploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021"
]
},
"references": [
{
"category": "external",
"summary": "Wibu-Systems Advisory",
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
}
],
"remediations": [
{
"category": "mitigation",
"details": "If possible, run CodeMeter as client only. Otherwise restrict access to server to required clients only by implementing an access list.\nGeneral security best practices can help to protect systems from local and network attacks.",
"product_ids": [
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"category": "vendor_fix",
"details": "Update to a codemeter runtime version \u003e=7.60c.\n",
"product_ids": [
"CSAFPID-0021"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"category": "vendor_fix",
"details": "Update to a codemeter runtime version \u003e=7.60c.\n\n*\tLinux x86: \n\n * Stop running SICK AppEngine \n\n * Uninstall Codemeter: sudo dpkg -r CodeMeter\n\n * Download Codemeter \u003e= 7.60c \n\n * Install Codemeter: sudo dpkg -i ./codemeter_7.xx.xxxx.xxx_amd64.deb\n\n * Start SICK AppEngine \n\n*\tWindows: \n\n * Stop running SICK AppEngine \n\n * Uninstall Codemeter using Windows settings app \n\n * Download Codemeter \u003e= 7.60c \n\n * Install CodeMeterRuntime.exe \n\n * Enter URL in browser: http://localhost:22352/configuration/server_access.html\n\n * Configuration \u003e Server \u003e Server Access \n\n * Check Network Server enabled \n\n * Start SICK AppEngine",
"product_ids": [
"CSAFPID-0017"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"category": "vendor_fix",
"details": "Update to a version \u003e= 2.4.1.",
"product_ids": [
"CSAFPID-0019",
"CSAFPID-0020"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.1,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 9,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021"
]
}
],
"title": "Wibu-Systems CVE"
}
]
}
SSA-240541
Vulnerability from csaf_siemens - Published: 2023-09-12 00:00 - Updated: 2024-05-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
PSS(R)CAPE V14
Siemens / PSS(R)CAPE V14
|
All versions < V14.2023-08-23 |
Mitigation
Vendor Fix
Workaround
|
|
|
PSS(R)CAPE V15
Siemens / PSS(R)CAPE V15
|
<V15.0.22 |
Mitigation
Mitigation
Vendor Fix
Workaround
|
|
|
PSS(R)E V34
Siemens / PSS(R)E V34
|
<V34.9.6 |
Mitigation
Mitigation
Vendor Fix
Workaround
|
|
|
PSS(R)E V35
Siemens / PSS(R)E V35
|
<V35.6.1 |
Mitigation
Mitigation
Vendor Fix
Workaround
|
|
|
PSS(R)ODMS V13.0
Siemens / PSS(R)ODMS V13.0
|
vers:all/* |
Mitigation
Vendor Fix
Workaround
|
|
|
PSS(R)ODMS V13.1
Siemens / PSS(R)ODMS V13.1
|
<V13.1.12.1 |
Mitigation
Mitigation
Vendor Fix
Workaround
|
|
|
SIMATIC PCS neo V3
Siemens / SIMATIC PCS neo V3
|
vers:all/* |
Mitigation
No Fix Planned
Workaround
|
|
|
SIMATIC PCS neo V4.0
Siemens / SIMATIC PCS neo V4.0
|
vers:all/* |
Mitigation
No Fix Planned
Workaround
|
|
|
SIMATIC WinCC OA V3.17
Siemens / SIMATIC WinCC OA V3.17
|
All versions < V3.17 P030 |
Mitigation
Vendor Fix
fix
Workaround
|
|
|
SIMATIC WinCC OA V3.18
Siemens / SIMATIC WinCC OA V3.18
|
All versions < V3.18 P021 |
Mitigation
Vendor Fix
fix
Workaround
|
|
|
SIMATIC WinCC OA V3.19
Siemens / SIMATIC WinCC OA V3.19
|
All versions < V3.19 P006 |
Mitigation
Vendor Fix
fix
Workaround
|
|
|
SIMIT Simulation Platform
Siemens / SIMIT Simulation Platform
|
>=V10.0<V11.2 |
Mitigation
Vendor Fix
fix
Workaround
|
|
|
SINEC INS
Siemens / SINEC INS
|
All versions < V1.0 SP2 Update 2 |
Mitigation
Vendor Fix
fix
Workaround
|
|
|
SINEMA Remote Connect
Siemens / SINEMA Remote Connect
|
vers:all/* |
Mitigation
No Fix Planned
Workaround
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "WIBU Systems published information about a heap buffer overflow vulnerability and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products for license management.\n\nThe vulnerability is described in the section \u0027Vulnerability Classification\u0027 below and got assigned the CVE ID CVE-2023-3935.\nSuccessful exploitation of this vulnerability could allow\n\n- an unauthenticated remote attacker to execute code on vulnerable products, where CodeMeter Runtime (i.e., CodeMeter.exe) is configured as a server, or\n- an authenticated local attacker to gain root/admin privileges on vulnerable products, where CodeMeter Runtime is configured as a client.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-240541: WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-240541.html"
},
{
"category": "self",
"summary": "SSA-240541: WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-240541.json"
},
{
"category": "self",
"summary": "SSA-240541: WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-240541.pdf"
},
{
"category": "self",
"summary": "SSA-240541: WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-240541.txt"
}
],
"title": "SSA-240541: WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products",
"tracking": {
"current_release_date": "2024-05-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-240541",
"initial_release_date": "2023-09-12T00:00:00Z",
"revision_history": [
{
"date": "2023-09-12T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-10-10T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for PSS(R)E V35, SIMATIC WinCC OA V3.17 and SIMATIC WinCC OA V3.18; no fix planned for SIMATIC PCS neo V4.0"
},
{
"date": "2023-12-12T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for SINEC INS"
},
{
"date": "2024-05-14T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for SIMIT Simulation Platform"
}
],
"status": "interim",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V14.2023-08-23",
"product": {
"name": "PSS(R)CAPE V14",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "PSS(R)CAPE V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV15.0.22",
"product": {
"name": "PSS(R)CAPE V15",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "PSS(R)CAPE V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV34.9.6",
"product": {
"name": "PSS(R)E V34",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "PSS(R)E V34"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV35.6.1",
"product": {
"name": "PSS(R)E V35",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "PSS(R)E V35"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "PSS(R)ODMS V13.0",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "PSS(R)ODMS V13.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.1.12.1",
"product": {
"name": "PSS(R)ODMS V13.1",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "PSS(R)ODMS V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V3",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V4.0",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V4.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V3.17 P030",
"product": {
"name": "SIMATIC WinCC OA V3.17",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V3.18 P021",
"product": {
"name": "SIMATIC WinCC OA V3.18",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V3.19 P006",
"product": {
"name": "SIMATIC WinCC OA V3.19",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA V3.19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V10.0\u003cV11.2",
"product": {
"name": "SIMIT Simulation Platform",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "SIMIT Simulation Platform"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V1.0 SP2 Update 2",
"product": {
"name": "SINEC INS",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "SINEC INS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINEMA Remote Connect",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "SINEMA Remote Connect"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To\r\nexploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege. (WIBU-230704-01)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14"
]
},
"remediations": [
{
"category": "mitigation",
"details": "If CodeMeter Runtime is configured as server: Limit remote access to systems where the CodeMeter Runtime network server is running",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14"
]
},
{
"category": "mitigation",
"details": "For affected versions: Install WIBU Systems CodeMeter Runtime V7.60c or later version manually to fix the issue: Download the package from \nhttps://www.wibu.com/support/user/user-software.html and follow the installation instructions from WIBU Systems.",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "For affected versions: Install WIBU Systems CodeMeter Runtime V7.60c or later version manually to fix the issue: Download the package from \nhttps://www.wibu.com/support/user/user-software.html and follow the installation instructions from WIBU Systems.",
"product_ids": [
"2",
"3",
"6"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"7",
"8",
"14"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.0 SP2 Update 2 or later version",
"product_ids": [
"13"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/"
},
{
"category": "vendor_fix",
"details": "Update to V11.2 or later version",
"product_ids": [
"12"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109954445/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.12.1 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V15.0.22 or later version",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V3.17 P030 or later version",
"product_ids": [
"9"
],
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"category": "vendor_fix",
"details": "Update to V3.18 P021 or later version",
"product_ids": [
"10"
],
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"category": "vendor_fix",
"details": "Update to V3.19 P006 or later version",
"product_ids": [
"11"
],
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"category": "vendor_fix",
"details": "Update to V34.9.6 or later version",
"product_ids": [
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V35.6.1 or later version",
"product_ids": [
"4"
]
},
{
"category": "vendor_fix",
"details": "CAPE V14 installations installed from material dated 2023-08-23 or later are not affected, as they contain a fixed version of CodeMeter Runtime.\n\nFor installations of CAPE V14 using material earlier than 2023-08-23: Install WIBU Systems CodeMeter Runtime V7.60c or later version manually to fix the issue: Download the package from \nhttps://www.wibu.com/support/user/user-software.html and follow the installation instructions from WIBU Systems.",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Install WIBU Systems CodeMeter Runtime V7.60c or later version manually to \ufb01x the issue: Download the package from \nhttps://www.wibu.com/support/user/user-software.html and follow the installation instructions from WIBU Systems.",
"product_ids": [
"5"
]
},
{
"category": "workaround",
"details": "If CodeMeter Runtime is configured as client only in the affected product: Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14"
]
}
],
"title": "CVE-2023-3935"
}
]
}
SSA-625850
Vulnerability from csaf_siemens - Published: 2023-11-14 00:00 - Updated: 2024-08-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo CC family V5.0
Siemens / Desigo CC family V5.0
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V5.1
Siemens / Desigo CC family V5.1
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V6
Siemens / Desigo CC family V6
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON powermanager
Siemens / SENTRON powermanager
|
>=V4.0 |
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo CC family V5.0
Siemens / Desigo CC family V5.0
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V5.1
Siemens / Desigo CC family V5.1
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V6
Siemens / Desigo CC family V6
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON powermanager
Siemens / SENTRON powermanager
|
>=V4.0 |
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo CC family V5.0
Siemens / Desigo CC family V5.0
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V5.1
Siemens / Desigo CC family V5.1
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V6
Siemens / Desigo CC family V6
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V7
Siemens / Desigo CC family V7
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON powermanager
Siemens / SENTRON powermanager
|
>=V4.0 |
Vendor Fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON powermanager, are affected by multiple vulnerabilities in the underlying third-party component WIBU Systems CodeMeter Runtime.\nSuccessful exploitation of these vulnerabilities could allow remote attackers to execute arbitrary code on the Desigo CC server, or create a denial of service condition.\nWhile all Desigo CC version lines V5.0, V5.1 and V6 are affected by all listed vulnerabilities, V7 is only affected by CVE-2023-3935.\n\nSiemens has released a patch to update the CodeMeter Runtime component and recommends to apply the patch on affected systems.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family and SENTRON powermanager - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-625850.html"
},
{
"category": "self",
"summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family and SENTRON powermanager - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-625850.json"
}
],
"title": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family and SENTRON powermanager",
"tracking": {
"current_release_date": "2024-08-13T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-625850",
"initial_release_date": "2023-11-14T00:00:00Z",
"revision_history": [
{
"date": "2023-11-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-08-13T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added SENTRON powermanager"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V5.0",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Desigo CC family V5.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V5.1",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Desigo CC family V5.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V6",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Desigo CC family V6"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V7",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Desigo CC family V7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V4.0",
"product": {
"name": "SENTRON powermanager",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SENTRON powermanager"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-20093",
"cwe": {
"id": "CWE-126",
"name": "Buffer Over-read"
},
"notes": [
{
"category": "summary",
"text": "A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.\n\nAn unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions",
"product_ids": [
"1",
"2",
"3",
"5"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"5"
]
}
],
"title": "CVE-2021-20093"
},
{
"cve": "CVE-2021-20094",
"cwe": {
"id": "CWE-126",
"name": "Buffer Over-read"
},
"notes": [
{
"category": "summary",
"text": "A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.\n\nAn unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions",
"product_ids": [
"1",
"2",
"3",
"5"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"5"
]
}
],
"title": "CVE-2021-20094"
},
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To\r\nexploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege. (WIBU-230704-01)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions",
"product_ids": [
"1",
"2",
"3",
"4",
"5"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5"
]
}
],
"title": "CVE-2023-3935"
}
]
}
VAR-202309-0672
Vulnerability from variot - Updated: 2025-07-04 22:29A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system. Wibu-Systems AG of CodeMeter Runtime Products from multiple vendors, such as the following, contain out-of-bounds write vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. PSS(R)CAPE is a transmission and distribution network protection simulation software. PSS(R)E is a power system simulation and analysis tool for transmission operation and planning. PSS(R)ODMS is a CIM-based network model management tool with network analysis capabilities for planning and operational planning of transmission utilities. SIMATIC PCS neo is a distributed control system (DCS). SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications requiring a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functionality. SIMIT Simulation Platform allows simulating factory settings to predict failures at an early planning stage. SINEC INS (Infrastructure Network Services) is a web-based application that combines various network services in one tool. SINEMA Remote Connect is a management platform for remote networks that allows simple management of tunnel connections (VPN) between headquarters, service technicians and installed machines or plants.
Siemens Industrial product WIBU system CodeMeter has a heap buffer overflow vulnerability, which is caused by failure to perform correct boundary checks. An attacker could exploit this vulnerability to cause a buffer overflow and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202309-0672",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "oseon",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "3.0.22"
},
{
"model": "tubedesign",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "14.06.150"
},
{
"model": "programmingtube",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "4.6.3"
},
{
"model": "trutopsfab",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "15.00.23.00"
},
{
"model": "teczonebend",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "23.06.01"
},
{
"model": "trutopsweld",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "9.0.28148.1"
},
{
"model": "trutops cell sw48",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "02.26.0"
},
{
"model": "trutopsprint",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "01.00"
},
{
"model": "trutops",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "08.00"
},
{
"model": "e-mobility charging suite",
"scope": "lte",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "1.7.0"
},
{
"model": "module type package designer",
"scope": "lt",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "1.2.0"
},
{
"model": "trutopsfab",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "22.8.25"
},
{
"model": "trutopsfab storage smallstore",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "14.06.20"
},
{
"model": "activation wizard",
"scope": "lte",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "1.6"
},
{
"model": "trutops",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "12.01.00.00"
},
{
"model": "tubedesign",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "08.00"
},
{
"model": "iol-conf",
"scope": "lte",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "1.7.0"
},
{
"model": "trutopsboost",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "06.00.23.00"
},
{
"model": "topscalculation",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "22.00.00"
},
{
"model": "trutopsprint",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "00.06.00"
},
{
"model": "trutops cell classic",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "09.09.02"
},
{
"model": "programmingtube",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "1.0.1"
},
{
"model": "trutopsboost",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "16.0.22"
},
{
"model": "fl network manager",
"scope": "lte",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "7.0"
},
{
"model": "teczonebend",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "18.02.r8"
},
{
"model": "trutops mark 3d",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "06.01"
},
{
"model": "codemeter runtime",
"scope": "lt",
"trust": 1.0,
"vendor": "wibu",
"version": "7.60c"
},
{
"model": "trutopsprintmultilaserassistant",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "01.02"
},
{
"model": "trumpflicenseexpert",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "1.5.2"
},
{
"model": "trutops mark 3d",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "01.00"
},
{
"model": "module type package designer",
"scope": "eq",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "1.2.0"
},
{
"model": "plcnext engineer",
"scope": "lte",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "2023.6"
},
{
"model": "trumpflicenseexpert",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "1.11.1"
},
{
"model": "trutopsweld",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "7.0.198.241"
},
{
"model": "trutops cell sw48",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "01.00"
},
{
"model": "tops unfold",
"scope": "eq",
"trust": 1.0,
"vendor": "trumpf",
"version": "05.03.00.00"
},
{
"model": "oseon",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "1.0.0"
},
{
"model": "topscalculation",
"scope": "gte",
"trust": 1.0,
"vendor": "trumpf",
"version": "14.00"
},
{
"model": "trutopsfab storage smallstore",
"scope": "lte",
"trust": 1.0,
"vendor": "trumpf",
"version": "20.04.20.00"
},
{
"model": "trumpflicenseexpert",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutops cell classic",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutops",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "teczonebend",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutopsweld",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutopsprint",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "tubedesign",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "oseon",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutopsboost",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutops mark 3d",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutopsprintmultilaserassistant",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "programmingtube",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutops cell sw48",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "codemeter runtime",
"scope": null,
"trust": 0.8,
"vendor": "wibu",
"version": null
},
{
"model": "topscalculation",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutopsfab",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "tops unfold",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "trutopsfab storage smallstore",
"scope": null,
"trust": 0.8,
"vendor": "trumpf",
"version": null
},
{
"model": "sinec ins",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simit simulation platform",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinema remote connect",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc oa",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3.17"
},
{
"model": "simatic wincc oa",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3.18"
},
{
"model": "pss cape",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14\u003cv14.2023-08-23"
},
{
"model": "pss cape",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v15\u003cv15.0.22"
},
{
"model": "pss e",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v34\u003cv34.9.6"
},
{
"model": "pss odms",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v13.0"
},
{
"model": "pss odms",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v13.1\u003cv13.1.12.1"
},
{
"model": "simatic pcs neo",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3"
},
{
"model": "simatic pcs neo",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v4"
},
{
"model": "simatic wincc oa p006",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3.19\u003cv3.19"
},
{
"model": "pss e",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v35"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"cve": "CVE-2023-3935",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.6,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 4.9,
"id": "CNVD-2023-69811",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "info@cert.vde.com",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-3935",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2023-012536",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "info@cert.vde.com",
"id": "CVE-2023-3935",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2023-3935",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2023-012536",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2023-69811",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system. Wibu-Systems AG of CodeMeter Runtime Products from multiple vendors, such as the following, contain out-of-bounds write vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. PSS(R)CAPE is a transmission and distribution network protection simulation software. PSS(R)E is a power system simulation and analysis tool for transmission operation and planning. PSS(R)ODMS is a CIM-based network model management tool with network analysis capabilities for planning and operational planning of transmission utilities. SIMATIC PCS neo is a distributed control system (DCS). SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications requiring a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functionality. SIMIT Simulation Platform allows simulating factory settings to predict failures at an early planning stage. SINEC INS (Infrastructure Network Services) is a web-based application that combines various network services in one tool. SINEMA Remote Connect is a management platform for remote networks that allows simple management of tunnel connections (VPN) between headquarters, service technicians and installed machines or plants. \n\r\n\r\nSiemens Industrial product WIBU system CodeMeter has a heap buffer overflow vulnerability, which is caused by failure to perform correct boundary checks. An attacker could exploit this vulnerability to cause a buffer overflow and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-3935"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"db": "VULMON",
"id": "CVE-2023-3935"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-3935",
"trust": 3.3
},
{
"db": "CERT@VDE",
"id": "VDE-2023-031",
"trust": 1.9
},
{
"db": "CERT@VDE",
"id": "VDE-2023-030",
"trust": 1.8
},
{
"db": "JVN",
"id": "JVNVU97192309",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU98137233",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU92008538",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU92598492",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-25-182-02",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-320-03",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-257-06",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-24-004-01",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536",
"trust": 0.8
},
{
"db": "SIEMENS",
"id": "SSA-240541",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2023-69811",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-3935",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"db": "VULMON",
"id": "CVE-2023-3935"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"id": "VAR-202309-0672",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
}
],
"trust": 1.1685151266666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
}
]
},
"last_update_date": "2025-07-04T22:29:03.104000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens Industrial product WIBU system CodeMeter heap buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/460931"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/advisorywibu-230704-01-v3.0.pdf"
},
{
"trust": 1.9,
"url": "https://cert.vde.com/en/advisories/vde-2023-031/"
},
{
"trust": 1.8,
"url": "https://cert.vde.com/en/advisories/vde-2023-030/"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98137233/"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92598492/"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92008538/index.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu97192309/index.html"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-3935"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-06"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-03"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-004-01"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-02"
},
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-240541.html"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"db": "VULMON",
"id": "CVE-2023-3935"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"db": "VULMON",
"id": "CVE-2023-3935"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"date": "2023-09-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-3935"
},
{
"date": "2023-12-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"date": "2023-09-13T14:15:09.147000",
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-69811"
},
{
"date": "2023-09-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-3935"
},
{
"date": "2025-07-03T05:52:00",
"db": "JVNDB",
"id": "JVNDB-2023-012536"
},
{
"date": "2024-01-25T20:24:58.783000",
"db": "NVD",
"id": "CVE-2023-3935"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Wibu-Systems\u00a0AG\u00a0 of \u00a0CodeMeter\u00a0Runtime\u00a0 Out-of-bounds write vulnerability in products from multiple vendors such as",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-012536"
}
],
"trust": 0.8
}
}
VDE-2023-030
Vulnerability from csaf_phoenixcontactgmbhcokg - Published: 2023-09-19 06:50 - Updated: 2023-11-13 11:00A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
PHOENIX CONTACT Activation Wizard in MORYX Software Platform 1.7
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard in MORYX Software Platform
|
1550589
|
1.7 | |
|
Activation Wizard 1.7
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard
|
1.7 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
E-Mobility Charging Suite <=1.7.0
Phoenix Contact / Software / E-Mobility Charging Suite
|
1153520
|
<=1.7.0 | |
|
FL Network Manager <=7.0
Phoenix Contact / Software / FL Network Manager
|
2702889
|
<=7.0 | |
|
IOL Conf <=1.7.0
Phoenix Contact / Software / IOL Conf
|
1083065
|
<=1.7.0 | |
|
MTP DESIGNER <=1.2.0 BETA
Phoenix Contact / Software / MTP DESIGNER
|
1636198
|
<=1.2.0 BETA | |
|
MTP DESIGNER TRIAL <=1.2.0 BETA
Phoenix Contact / Software / MTP DESIGNER TRIAL
|
1636200
|
<=1.2.0 BETA | |
|
PHOENIX CONTACT Activation Wizard <=1.6
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard
|
<=1.6 | ||
|
PHOENIX CONTACT Activation Wizard in MORYX Software Platform <=1.6
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard in MORYX Software Platform
|
1550589
|
<=1.6 | |
|
PLCnext Engineer <=2023.6
Phoenix Contact / Software / PLCnext Engineer
|
1046008
|
<=2023.6 | |
|
PLCnext Engineer EDU LIC <=2023.6
Phoenix Contact / Software / PLCnext Engineer EDU LIC
|
1165889
|
<=2023.6 |
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "A Vulnerability in WIBU-SYSTEMS CodeMeter Runtime affects multiple\u00a0Phoenix Contact\u00a0products.\nPhoenix Contact devices using CodeMeter embedded are not affected by\u00a0this\u00a0vulnerability.\nUpdate A, 2023-11-13\nRemoved CVE-2023-4701 because it was revoked.",
"title": "Summary"
},
{
"category": "description",
"text": "An attacker exploiting the vulnerability in WIBU CodeMeter Runtime in server mode could gain full access to the affected server via network access without any user interaction.\nExploiting the vulnerability in WIBU CodeMeter Runtime in non-networked workstation mode could lead to a privilege elevation and full admin access on this workstation.",
"title": "Impact"
},
{
"category": "description",
"text": "1. Use general security best practices to protect systems from local and network attacks like described in the application node AH EN INDUSTRIAL SECURITY.\n\n2. Run CodeMeter as client only and use localhost as binding for the CodeMeter communication. With binding to localhost an attack is no longer possible via remote network connection. The network server is disabled by default. If it is not possible to disable the network server, using a host-based firewall to restrict access to the network for reducing the risk is strongly recommended.\n\n3. The CmWAN server is disabled by default. Please check if CmWAN is enabled and disable the feature if it is not needed.\n\n4. Run the CmWAN server only behind a reverse proxy with user authentication to prevent attacks from unauthenticated users. The risk of an unauthenticated attacker can be further reduced by using a host-based firewall that only allows the reverse proxy to access the CmWAN port.",
"title": "Mitigation"
},
{
"category": "description",
"text": "PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V7.60c, which fixes these vulnerabilities. WIBU-SYSTEMS has already published this update for CodeMeter on their homepage. Since this current version of CodeMeter V7.60c has not yet been incorporated into Phoenix Contact products, we strongly recommend to download and install the current CodeMeter version directly from the WIBU-SYSTEMS homepage.\n\nInstall Phoenix Contact Activation Wizard from version 1.7 when available.Please check the Phoenix Contact e-Shop for your related Software product regularly.",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@phoenixcontact.com",
"name": "Phoenix Contact GmbH \u0026 Co. KG",
"namespace": "https://phoenixcontact.com/psirt"
},
"references": [
{
"category": "self",
"summary": "VDE-2023-030: Phoenix Contact: Multiple products affected by WIBU Codemeter Vulnerability (Update A) - HTML",
"url": "https://certvde.com/en/advisories/VDE-2023-030/"
},
{
"category": "self",
"summary": "VDE-2023-030: Phoenix Contact: Multiple products affected by WIBU Codemeter Vulnerability (Update A) - CSAF",
"url": "https://phoenixcontact.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-030.json"
},
{
"category": "external",
"summary": "Vendor PSIRT",
"url": "https://phoenixcontact.com/psirt"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories for Phoenix Contact GmbH \u0026 Co. KG",
"url": "https://certvde.com/en/advisories/vendor/phoenixcontact/"
}
],
"title": "Phoenix Contact: Multiple products affected by WIBU Codemeter Vulnerability (Update A)",
"tracking": {
"aliases": [
"VDE-2023-030"
],
"current_release_date": "2023-11-13T11:00:00.000Z",
"generator": {
"date": "2025-04-10T09:18:47.042Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.23"
}
},
"id": "VDE-2023-030",
"initial_release_date": "2023-09-19T06:50:00.000Z",
"revision_history": [
{
"date": "2023-09-19T06:50:00.000Z",
"number": "1",
"summary": "Initial revision."
},
{
"date": "2023-11-13T11:00:00.000Z",
"number": "2",
"summary": "Update A"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.7.0",
"product": {
"name": "E-Mobility Charging Suite \u003c=1.7.0",
"product_id": "CSAFPID-51001",
"product_identification_helper": {
"model_numbers": [
"1153520"
]
}
}
}
],
"category": "product_name",
"name": "E-Mobility Charging Suite"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=7.0",
"product": {
"name": "FL Network Manager \u003c=7.0",
"product_id": "CSAFPID-51002",
"product_identification_helper": {
"model_numbers": [
"2702889"
]
}
}
}
],
"category": "product_name",
"name": "FL Network Manager"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.7.0",
"product": {
"name": "IOL Conf \u003c=1.7.0",
"product_id": "CSAFPID-51003",
"product_identification_helper": {
"model_numbers": [
"1083065"
]
}
}
}
],
"category": "product_name",
"name": "IOL Conf"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.2.0 BETA",
"product": {
"name": "MTP DESIGNER \u003c=1.2.0 BETA",
"product_id": "CSAFPID-51004",
"product_identification_helper": {
"model_numbers": [
"1636198"
]
}
}
}
],
"category": "product_name",
"name": "MTP DESIGNER"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.2.0 BETA",
"product": {
"name": "MTP DESIGNER TRIAL \u003c=1.2.0 BETA",
"product_id": "CSAFPID-51005",
"product_identification_helper": {
"model_numbers": [
"1636200"
]
}
}
}
],
"category": "product_name",
"name": "MTP DESIGNER TRIAL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.6",
"product": {
"name": "PHOENIX CONTACT Activation Wizard \u003c=1.6",
"product_id": "CSAFPID-51006"
}
},
{
"category": "product_version",
"name": "1.7",
"product": {
"name": "Activation Wizard 1.7",
"product_id": "CSAFPID-52002"
}
}
],
"category": "product_name",
"name": "PHOENIX CONTACT Activation Wizard"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.6",
"product": {
"name": "PHOENIX CONTACT Activation Wizard in MORYX Software Platform \u003c=1.6",
"product_id": "CSAFPID-51007",
"product_identification_helper": {
"model_numbers": [
"1550589"
]
}
}
},
{
"category": "product_version",
"name": "1.7",
"product": {
"name": "PHOENIX CONTACT Activation Wizard in MORYX Software Platform 1.7",
"product_id": "CSAFPID-52001",
"product_identification_helper": {
"model_numbers": [
"1550589"
]
}
}
}
],
"category": "product_name",
"name": "PHOENIX CONTACT Activation Wizard in MORYX Software Platform"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2023.6",
"product": {
"name": "PLCnext Engineer \u003c=2023.6",
"product_id": "CSAFPID-51008",
"product_identification_helper": {
"model_numbers": [
"1046008"
]
}
}
}
],
"category": "product_name",
"name": "PLCnext Engineer"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2023.6",
"product": {
"name": "PLCnext Engineer EDU LIC \u003c=2023.6",
"product_id": "CSAFPID-51009",
"product_identification_helper": {
"model_numbers": [
"1165889"
]
}
}
}
],
"category": "product_name",
"name": "PLCnext Engineer EDU LIC"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "Phoenix Contact"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009"
],
"summary": "Affected products."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"summary": "Fixed products."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"known_affected": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009"
]
},
"remediations": [
{
"category": "mitigation",
"details": "1. Use general security best practices to protect systems from local and network attacks like described in the application node AH EN INDUSTRIAL SECURITY.\n\n2. Run CodeMeter as client only and use localhost as binding for the CodeMeter communication. With binding to localhost an attack is no longer possible via remote network connection. The network server is disabled by default. If it is not possible to disable the network server, using a host-based firewall to restrict access to the network for reducing the risk is strongly recommended.\n\n3. The CmWAN server is disabled by default. Please check if CmWAN is enabled and disable the feature if it is not needed.\n\n4. Run the CmWAN server only behind a reverse proxy with user authentication to prevent attacks from unauthenticated users. The risk of an unauthenticated attacker can be further reduced by using a host-based firewall that only allows the reverse proxy to access the CmWAN port.",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "vendor_fix",
"details": "PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V7.60c, which fixes these vulnerabilities. WIBU-SYSTEMS has already published this update for CodeMeter on their homepage. Since this current version of CodeMeter V7.60c has not yet been incorporated into Phoenix Contact products, we strongly recommend to download and install the current CodeMeter version directly from the WIBU-SYSTEMS homepage.\n\nInstall Phoenix Contact Activation Wizard from version 1.7 when available.Please check the Phoenix Contact e-Shop for your related Software product regularly.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009"
]
}
],
"title": "CVE-2023-3935"
}
]
}
VDE-2023-031
Vulnerability from csaf_trumpfsecokg - Published: 2023-09-13 10:00 - Updated: 2023-11-13 11:00A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
MonitoringAnalyzer V1.0<=V1.3
Trumpf / Software / MonitoringAnalyzer
|
V1.0<=V1.3 | ||
|
Oseon V1.0.0<=V3.0.22
Trumpf / Software / Oseon
|
V1.0.0<=V3.0.22 | ||
|
ProgrammingTube V1.0.1<=V4.6.3
Trumpf / Software / ProgrammingTube
|
V1.0.1<=V4.6.3 | ||
|
TecZoneBend V18.02.R8<=V23.06.01
Trumpf / Software / TecZoneBend
|
V18.02.R8<=V23.06.01 | ||
|
ToPsCalculation V14.00<=V22.00.00
Trumpf / Software / ToPsCalculation
|
V14.00<=V22.00.00 | ||
|
Tops Unfold V05.03.00.00
Trumpf / Software / Tops Unfold
|
V05.03.00.00 | ||
|
TrumpfLicenseExpert V1.5.2<=V1.11.1
Trumpf / Software / TrumpfLicenseExpert
|
V1.5.2<=V1.11.1 | ||
|
TruTops V08.00<=V12.01.00.00
Trumpf / Software / TruTops
|
V08.00<=V12.01.00.00 | ||
|
TruTopsBoost V06.00.23.00<=V16.0.22
Trumpf / Software / TruTopsBoost
|
V06.00.23.00<=V16.0.22 | ||
|
TruTops Cell Classic <=V09.09.02
Trumpf / Software / TruTops Cell Classic
|
<=V09.09.02 | ||
|
TruTops Cell SW48 V01.00<=V02.26.0
Trumpf / Software / TruTops Cell SW48
|
V01.00<=V02.26.0 | ||
|
TruTopsFab (inkl.TruTops Monitor) V15.00.23.00<=V22.8.25
Trumpf / Software / TruTopsFab (inkl.TruTops Monitor)
|
V15.00.23.00<=V22.8.25 | ||
|
TruTopsFab_Storage_SmallStore V14.06.20<=V20.04.20.00
Trumpf / Software / TruTopsFab_Storage_SmallStore
|
V14.06.20<=V20.04.20.00 | ||
|
TruTops Mark 3D V01.00<=V06.01
Trumpf / Software / TruTops Mark 3D
|
V01.00<=V06.01 | ||
|
TruTopsPrint V00.06.00<=V01.00
Trumpf / Software / TruTopsPrint
|
V00.06.00<=V01.00 | ||
|
TruTopsPrintMultilaserAssistant >=V01.02
Trumpf / Software / TruTopsPrintMultilaserAssistant
|
>=V01.02 | ||
|
TruTopsWeld V7.0.198.241<=V9.0.28148.1
Trumpf / Software / TruTopsWeld
|
V7.0.198.241<=V9.0.28148.1 | ||
|
TubeDesign V08.00<=V14.06.150
Trumpf / Software / TubeDesign
|
V08.00<=V14.06.150 |
| URL | Category |
|---|---|
| https://certvde.com/en/advisories/VDE-2023-031/ | self |
| https://trumpf.csaf-tp.certvde.com/.well-known/cs… | self |
| https://www.trumpf.com | external |
| https://certvde.com/en/advisories/vendor/trumpf/ | external |
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "The TRUMPF CAD/CAM software tools mentioned above use the vulnerable CodeMeter Runtime (up to version 7.60b) application from WIBU-SYSTEMS AG to manage licenses within the component TRUMPF License Expert. This CodeMeter application contains new vulnerabilities, which may enable an attacker to gain full access to the server or workstation on which the TRUMPF License Expert has been installed on. A new version of the TRUMPF License Expert which fixes this vulnerability is available.Machines with a running and correctly installed mGuard hardware firewall cannot be exploited by this vulnerability if used as intended (according to the manual).\n\nUpdate A, 2023-11-13\nRemoved CVE-2023-4701 because it was revoked.",
"title": "Summary"
},
{
"category": "description",
"text": "An attacker exploiting the vulnerability in WIBU CodeMeter Runtime in server mode could gain full access to the affected server via network access without any user interaction.\nExploiting the vulnerability in WIBU CodeMeter Runtime in non-networked workstation mode could lead to a privilege elevation and full access on this workstation for an already authenticated user (logged in locally to the PC).",
"title": "Impact"
},
{
"category": "description",
"text": "Implement general security best practices like network segmentation, endpoint protection and system hardening.\nRestrict network access to the TRUMPF License Expert server component to required clients only by using firewalls or other suitable products.",
"title": "Mitigation"
},
{
"category": "description",
"text": "Get the latest version of the TRUMPF License Expert software (\u003e= V2.0.0)\u00a0at\u00a0trumpf.com/de_DE/produkte/software/software-lizenzierung\u00a0and install it on all affected servers and workstations.",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "product.security@trumpf.com",
"name": "Trumpf SE + Co. KG",
"namespace": "https://www.trumpf.com"
},
"references": [
{
"category": "self",
"summary": "VDE-2023-031: Trumpf: Multiple Products affected by WIBU Codemeter Vulnerability - HTML",
"url": "https://certvde.com/en/advisories/VDE-2023-031/"
},
{
"category": "self",
"summary": "VDE-2023-031: Trumpf: Multiple Products affected by WIBU Codemeter Vulnerability - CSAF",
"url": "https://trumpf.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-031.json"
},
{
"category": "external",
"summary": "Vendor PSIRT",
"url": "https://www.trumpf.com"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories for Trumpf SE + Co. KG",
"url": "https://certvde.com/en/advisories/vendor/trumpf/"
}
],
"title": "Trumpf: Multiple Products affected by WIBU Codemeter Vulnerability",
"tracking": {
"aliases": [
"VDE-2023-031"
],
"current_release_date": "2023-11-13T11:00:00.000Z",
"generator": {
"date": "2025-05-14T13:50:48.706Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.25"
}
},
"id": "VDE-2023-031",
"initial_release_date": "2023-09-13T10:00:00.000Z",
"revision_history": [
{
"date": "2023-09-13T10:00:00.000Z",
"number": "1",
"summary": "Initial revision."
},
{
"date": "2023-11-13T11:00:00.000Z",
"number": "2",
"summary": "Update A"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "V1.0\u003c=V1.3",
"product": {
"name": "MonitoringAnalyzer V1.0\u003c=V1.3",
"product_id": "CSAFPID-51001"
}
}
],
"category": "product_name",
"name": "MonitoringAnalyzer"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V1.0.0\u003c=V3.0.22",
"product": {
"name": "Oseon V1.0.0\u003c=V3.0.22",
"product_id": "CSAFPID-51002"
}
}
],
"category": "product_name",
"name": "Oseon"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V1.0.1\u003c=V4.6.3",
"product": {
"name": "ProgrammingTube V1.0.1\u003c=V4.6.3",
"product_id": "CSAFPID-51003"
}
}
],
"category": "product_name",
"name": "ProgrammingTube"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V18.02.R8\u003c=V23.06.01",
"product": {
"name": "TecZoneBend V18.02.R8\u003c=V23.06.01",
"product_id": "CSAFPID-51004"
}
}
],
"category": "product_name",
"name": "TecZoneBend"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V14.00\u003c=V22.00.00",
"product": {
"name": "ToPsCalculation V14.00\u003c=V22.00.00",
"product_id": "CSAFPID-51005"
}
}
],
"category": "product_name",
"name": "ToPsCalculation"
},
{
"branches": [
{
"category": "product_version",
"name": "V05.03.00.00",
"product": {
"name": "Tops Unfold V05.03.00.00",
"product_id": "CSAFPID-51006"
}
}
],
"category": "product_name",
"name": "Tops Unfold"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V1.5.2\u003c=V1.11.1",
"product": {
"name": "TrumpfLicenseExpert V1.5.2\u003c=V1.11.1",
"product_id": "CSAFPID-51007"
}
}
],
"category": "product_name",
"name": "TrumpfLicenseExpert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V08.00\u003c=V12.01.00.00",
"product": {
"name": "TruTops V08.00\u003c=V12.01.00.00",
"product_id": "CSAFPID-51008"
}
}
],
"category": "product_name",
"name": "TruTops"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V06.00.23.00\u003c=V16.0.22",
"product": {
"name": "TruTopsBoost V06.00.23.00\u003c=V16.0.22",
"product_id": "CSAFPID-51009"
}
}
],
"category": "product_name",
"name": "TruTopsBoost"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V09.09.02",
"product": {
"name": "TruTops Cell Classic \u003c=V09.09.02",
"product_id": "CSAFPID-510010"
}
}
],
"category": "product_name",
"name": "TruTops Cell Classic"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V01.00\u003c=V02.26.0",
"product": {
"name": "TruTops Cell SW48 V01.00\u003c=V02.26.0",
"product_id": "CSAFPID-510011"
}
}
],
"category": "product_name",
"name": "TruTops Cell SW48"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V15.00.23.00\u003c=V22.8.25",
"product": {
"name": "TruTopsFab (inkl.TruTops Monitor) V15.00.23.00\u003c=V22.8.25",
"product_id": "CSAFPID-510012"
}
}
],
"category": "product_name",
"name": "TruTopsFab (inkl.TruTops Monitor)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V14.06.20\u003c=V20.04.20.00",
"product": {
"name": "TruTopsFab_Storage_SmallStore V14.06.20\u003c=V20.04.20.00",
"product_id": "CSAFPID-510013"
}
}
],
"category": "product_name",
"name": "TruTopsFab_Storage_SmallStore"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V01.00\u003c=V06.01",
"product": {
"name": "TruTops Mark 3D V01.00\u003c=V06.01",
"product_id": "CSAFPID-510014"
}
}
],
"category": "product_name",
"name": "TruTops Mark 3D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V00.06.00\u003c=V01.00",
"product": {
"name": "TruTopsPrint V00.06.00\u003c=V01.00",
"product_id": "CSAFPID-510015"
}
}
],
"category": "product_name",
"name": "TruTopsPrint"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V01.02",
"product": {
"name": "TruTopsPrintMultilaserAssistant \u003e=V01.02",
"product_id": "CSAFPID-510016"
}
}
],
"category": "product_name",
"name": "TruTopsPrintMultilaserAssistant"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V7.0.198.241\u003c=V9.0.28148.1",
"product": {
"name": "TruTopsWeld V7.0.198.241\u003c=V9.0.28148.1",
"product_id": "CSAFPID-510017"
}
}
],
"category": "product_name",
"name": "TruTopsWeld"
},
{
"branches": [
{
"category": "product_version_range",
"name": "V08.00\u003c=V14.06.150",
"product": {
"name": "TubeDesign V08.00\u003c=V14.06.150",
"product_id": "CSAFPID-510018"
}
}
],
"category": "product_name",
"name": "TubeDesign"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "Trumpf"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009",
"CSAFPID-510010",
"CSAFPID-510011",
"CSAFPID-510012",
"CSAFPID-510013",
"CSAFPID-510014",
"CSAFPID-510015",
"CSAFPID-510016",
"CSAFPID-510017",
"CSAFPID-510018"
],
"summary": "Affected products."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009",
"CSAFPID-510010",
"CSAFPID-510011",
"CSAFPID-510012",
"CSAFPID-510013",
"CSAFPID-510014",
"CSAFPID-510015",
"CSAFPID-510016",
"CSAFPID-510017",
"CSAFPID-510018"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Implement general security best practices like network segmentation, endpoint protection and system hardening.\nRestrict network access to the TRUMPF License Expert server component to required clients only by using firewalls or other suitable products.",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "vendor_fix",
"details": "Get the latest version of the TRUMPF License Expert software (\u003e= V2.0.0)\u00a0at\u00a0trumpf.com/de_DE/produkte/software/software-lizenzierung\u00a0and install it on all affected servers and workstations.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009",
"CSAFPID-510010",
"CSAFPID-510011",
"CSAFPID-510012",
"CSAFPID-510013",
"CSAFPID-510014",
"CSAFPID-510015",
"CSAFPID-510016",
"CSAFPID-510017",
"CSAFPID-510018"
]
}
],
"title": "CVE-2023-3935"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.