VDE-2023-030
Vulnerability from csaf_phoenixcontactgmbhcokg - Published: 2023-09-19 06:50 - Updated: 2023-11-13 11:00A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
PHOENIX CONTACT Activation Wizard in MORYX Software Platform 1.7
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard in MORYX Software Platform
|
1550589
|
1.7 | |
|
Activation Wizard 1.7
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard
|
1.7 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
E-Mobility Charging Suite <=1.7.0
Phoenix Contact / Software / E-Mobility Charging Suite
|
1153520
|
<=1.7.0 | |
|
FL Network Manager <=7.0
Phoenix Contact / Software / FL Network Manager
|
2702889
|
<=7.0 | |
|
IOL Conf <=1.7.0
Phoenix Contact / Software / IOL Conf
|
1083065
|
<=1.7.0 | |
|
MTP DESIGNER <=1.2.0 BETA
Phoenix Contact / Software / MTP DESIGNER
|
1636198
|
<=1.2.0 BETA | |
|
MTP DESIGNER TRIAL <=1.2.0 BETA
Phoenix Contact / Software / MTP DESIGNER TRIAL
|
1636200
|
<=1.2.0 BETA | |
|
PHOENIX CONTACT Activation Wizard <=1.6
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard
|
<=1.6 | ||
|
PHOENIX CONTACT Activation Wizard in MORYX Software Platform <=1.6
Phoenix Contact / Software / PHOENIX CONTACT Activation Wizard in MORYX Software Platform
|
1550589
|
<=1.6 | |
|
PLCnext Engineer <=2023.6
Phoenix Contact / Software / PLCnext Engineer
|
1046008
|
<=2023.6 | |
|
PLCnext Engineer EDU LIC <=2023.6
Phoenix Contact / Software / PLCnext Engineer EDU LIC
|
1165889
|
<=2023.6 |
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "A Vulnerability in WIBU-SYSTEMS CodeMeter Runtime affects multiple\u00a0Phoenix Contact\u00a0products.\nPhoenix Contact devices using CodeMeter embedded are not affected by\u00a0this\u00a0vulnerability.\nUpdate A, 2023-11-13\nRemoved CVE-2023-4701 because it was revoked.",
"title": "Summary"
},
{
"category": "description",
"text": "An attacker exploiting the vulnerability in WIBU CodeMeter Runtime in server mode could gain full access to the affected server via network access without any user interaction.\nExploiting the vulnerability in WIBU CodeMeter Runtime in non-networked workstation mode could lead to a privilege elevation and full admin access on this workstation.",
"title": "Impact"
},
{
"category": "description",
"text": "1. Use general security best practices to protect systems from local and network attacks like described in the application node AH EN INDUSTRIAL SECURITY.\n\n2. Run CodeMeter as client only and use localhost as binding for the CodeMeter communication. With binding to localhost an attack is no longer possible via remote network connection. The network server is disabled by default. If it is not possible to disable the network server, using a host-based firewall to restrict access to the network for reducing the risk is strongly recommended.\n\n3. The CmWAN server is disabled by default. Please check if CmWAN is enabled and disable the feature if it is not needed.\n\n4. Run the CmWAN server only behind a reverse proxy with user authentication to prevent attacks from unauthenticated users. The risk of an unauthenticated attacker can be further reduced by using a host-based firewall that only allows the reverse proxy to access the CmWAN port.",
"title": "Mitigation"
},
{
"category": "description",
"text": "PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V7.60c, which fixes these vulnerabilities. WIBU-SYSTEMS has already published this update for CodeMeter on their homepage. Since this current version of CodeMeter V7.60c has not yet been incorporated into Phoenix Contact products, we strongly recommend to download and install the current CodeMeter version directly from the WIBU-SYSTEMS homepage.\n\nInstall Phoenix Contact Activation Wizard from version 1.7 when available.Please check the Phoenix Contact e-Shop for your related Software product regularly.",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@phoenixcontact.com",
"name": "Phoenix Contact GmbH \u0026 Co. KG",
"namespace": "https://phoenixcontact.com/psirt"
},
"references": [
{
"category": "self",
"summary": "VDE-2023-030: Phoenix Contact: Multiple products affected by WIBU Codemeter Vulnerability (Update A) - HTML",
"url": "https://certvde.com/en/advisories/VDE-2023-030/"
},
{
"category": "self",
"summary": "VDE-2023-030: Phoenix Contact: Multiple products affected by WIBU Codemeter Vulnerability (Update A) - CSAF",
"url": "https://phoenixcontact.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-030.json"
},
{
"category": "external",
"summary": "Vendor PSIRT",
"url": "https://phoenixcontact.com/psirt"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories for Phoenix Contact GmbH \u0026 Co. KG",
"url": "https://certvde.com/en/advisories/vendor/phoenixcontact/"
}
],
"title": "Phoenix Contact: Multiple products affected by WIBU Codemeter Vulnerability (Update A)",
"tracking": {
"aliases": [
"VDE-2023-030"
],
"current_release_date": "2023-11-13T11:00:00.000Z",
"generator": {
"date": "2025-04-10T09:18:47.042Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.23"
}
},
"id": "VDE-2023-030",
"initial_release_date": "2023-09-19T06:50:00.000Z",
"revision_history": [
{
"date": "2023-09-19T06:50:00.000Z",
"number": "1",
"summary": "Initial revision."
},
{
"date": "2023-11-13T11:00:00.000Z",
"number": "2",
"summary": "Update A"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.7.0",
"product": {
"name": "E-Mobility Charging Suite \u003c=1.7.0",
"product_id": "CSAFPID-51001",
"product_identification_helper": {
"model_numbers": [
"1153520"
]
}
}
}
],
"category": "product_name",
"name": "E-Mobility Charging Suite"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=7.0",
"product": {
"name": "FL Network Manager \u003c=7.0",
"product_id": "CSAFPID-51002",
"product_identification_helper": {
"model_numbers": [
"2702889"
]
}
}
}
],
"category": "product_name",
"name": "FL Network Manager"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.7.0",
"product": {
"name": "IOL Conf \u003c=1.7.0",
"product_id": "CSAFPID-51003",
"product_identification_helper": {
"model_numbers": [
"1083065"
]
}
}
}
],
"category": "product_name",
"name": "IOL Conf"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.2.0 BETA",
"product": {
"name": "MTP DESIGNER \u003c=1.2.0 BETA",
"product_id": "CSAFPID-51004",
"product_identification_helper": {
"model_numbers": [
"1636198"
]
}
}
}
],
"category": "product_name",
"name": "MTP DESIGNER"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.2.0 BETA",
"product": {
"name": "MTP DESIGNER TRIAL \u003c=1.2.0 BETA",
"product_id": "CSAFPID-51005",
"product_identification_helper": {
"model_numbers": [
"1636200"
]
}
}
}
],
"category": "product_name",
"name": "MTP DESIGNER TRIAL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.6",
"product": {
"name": "PHOENIX CONTACT Activation Wizard \u003c=1.6",
"product_id": "CSAFPID-51006"
}
},
{
"category": "product_version",
"name": "1.7",
"product": {
"name": "Activation Wizard 1.7",
"product_id": "CSAFPID-52002"
}
}
],
"category": "product_name",
"name": "PHOENIX CONTACT Activation Wizard"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.6",
"product": {
"name": "PHOENIX CONTACT Activation Wizard in MORYX Software Platform \u003c=1.6",
"product_id": "CSAFPID-51007",
"product_identification_helper": {
"model_numbers": [
"1550589"
]
}
}
},
{
"category": "product_version",
"name": "1.7",
"product": {
"name": "PHOENIX CONTACT Activation Wizard in MORYX Software Platform 1.7",
"product_id": "CSAFPID-52001",
"product_identification_helper": {
"model_numbers": [
"1550589"
]
}
}
}
],
"category": "product_name",
"name": "PHOENIX CONTACT Activation Wizard in MORYX Software Platform"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2023.6",
"product": {
"name": "PLCnext Engineer \u003c=2023.6",
"product_id": "CSAFPID-51008",
"product_identification_helper": {
"model_numbers": [
"1046008"
]
}
}
}
],
"category": "product_name",
"name": "PLCnext Engineer"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2023.6",
"product": {
"name": "PLCnext Engineer EDU LIC \u003c=2023.6",
"product_id": "CSAFPID-51009",
"product_identification_helper": {
"model_numbers": [
"1165889"
]
}
}
}
],
"category": "product_name",
"name": "PLCnext Engineer EDU LIC"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "Phoenix Contact"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009"
],
"summary": "Affected products."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"summary": "Fixed products."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-3935",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"known_affected": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009"
]
},
"remediations": [
{
"category": "mitigation",
"details": "1. Use general security best practices to protect systems from local and network attacks like described in the application node AH EN INDUSTRIAL SECURITY.\n\n2. Run CodeMeter as client only and use localhost as binding for the CodeMeter communication. With binding to localhost an attack is no longer possible via remote network connection. The network server is disabled by default. If it is not possible to disable the network server, using a host-based firewall to restrict access to the network for reducing the risk is strongly recommended.\n\n3. The CmWAN server is disabled by default. Please check if CmWAN is enabled and disable the feature if it is not needed.\n\n4. Run the CmWAN server only behind a reverse proxy with user authentication to prevent attacks from unauthenticated users. The risk of an unauthenticated attacker can be further reduced by using a host-based firewall that only allows the reverse proxy to access the CmWAN port.",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "vendor_fix",
"details": "PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V7.60c, which fixes these vulnerabilities. WIBU-SYSTEMS has already published this update for CodeMeter on their homepage. Since this current version of CodeMeter V7.60c has not yet been incorporated into Phoenix Contact products, we strongly recommend to download and install the current CodeMeter version directly from the WIBU-SYSTEMS homepage.\n\nInstall Phoenix Contact Activation Wizard from version 1.7 when available.Please check the Phoenix Contact e-Shop for your related Software product regularly.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-51001",
"CSAFPID-51002",
"CSAFPID-51003",
"CSAFPID-51004",
"CSAFPID-51005",
"CSAFPID-51006",
"CSAFPID-51007",
"CSAFPID-51008",
"CSAFPID-51009"
]
}
],
"title": "CVE-2023-3935"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.