CVE-2017-6867 (GCVE-0-2017-6867)

Vulnerability from cvelistv5 – Published: 2017-05-11 10:00 – Updated: 2024-08-05 15:41
VLAI
Summary
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface.
CWE
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 98 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
n/a Siemens SIMATIC WinCC Affected: Siemens SIMATIC WinCC
Date Public
2017-05-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:41:17.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "98368",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98368"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Siemens SIMATIC WinCC",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Siemens SIMATIC WinCC"
            }
          ]
        }
      ],
      "datePublic": "2017-05-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-13T09:57:01.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "98368",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98368"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-6867",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Siemens SIMATIC WinCC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Siemens SIMATIC WinCC"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "98368",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98368"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-6867",
    "datePublished": "2017-05-11T10:00:00.000Z",
    "dateReserved": "2017-03-13T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:41:17.675Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-6867",
      "date": "2026-10-14",
      "epss": "0.01923",
      "percentile": "0.79515"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13:sp1:*:*:professional:*:*:*",
                    "matchCriteriaId": "F8FA6B17-FA61-44FC-BAA7-AAC63ECBD996",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14:*:*:*:professional:*:*:*",
                    "matchCriteriaId": "B0E21465-76ED-4803-A40A-539500B993F9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*",
                    "matchCriteriaId": "57CE0216-AA81-416B-88D2-3321D2A2A16D",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*",
                    "matchCriteriaId": "D8893E54-CF26-448A-9C32-90E5F8D8CC84",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface."
          },
          {
            "lang": "es",
            "value": "Se detect\u00f3 una vulnerabilidad en SIMATIC WinCC (versi\u00f3n V7.3 anterior a Upd 11 y versi\u00f3n V7.4 anterior a SP1), SIMATIC WinCC Runtime Professional (versi\u00f3n V13 anterior a SP2 y versi\u00f3n V14 anterior a SP1), SIMATIC WinCC (TIA Portal) Professional (versi\u00f3n V13 anterior a SP2 y versi\u00f3n V14 anterior a SP1) de Siemens, eso podr\u00eda permitir a un atacante remoto autenticado, quien es miembro del grupo de los \"administrators\" bloquear los servicios enviando mensajes especialmente dise\u00f1ados a la interfaz DCOM."
          }
        ],
        "id": "CVE-2017-6867",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-05-11T10:29:00.260",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98368"
          },
          {
            "source": "productcert@siemens.com",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"
          },
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98368"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.