CVE-2017-6034 (GCVE-0-2017-6034)

Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2026-06-04 21:07
VLAI
Title
Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
Summary
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Date Public
2017-06-29 00:00
Credits
Eran Goldstein of CRITIFENCE reported the identified vulnerabilities.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.398Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
          },
          {
            "name": "97562",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97562"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2017-6034",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-28T19:09:00.802921Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-28T19:09:05.551Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Modbus Protocol",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eran Goldstein of CRITIFENCE reported the identified vulnerabilities."
        }
      ],
      "datePublic": "2017-06-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.\u003c/p\u003e"
            }
          ],
          "value": "An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-294",
              "description": "CWE-294",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-04T21:07:21.157Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
        },
        {
          "name": "97562",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97562"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-101-01.json"
        },
        {
          "url": "https://www.se.com/us/en/download/document/SEVD-2017-065-01/"
        }
      ],
      "source": {
        "advisory": "ICSA-17-101-01",
        "discovery": "UNKNOWN"
      },
      "title": "Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.\u003c/p\u003e\u003cp\u003eSchneider Electric\u2019s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:\u003c/p\u003e\u003cul\u003e\u003cli\u003eProtect access to M1E controllers by a firewall blocking all remote/external access to Port 502.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eSchneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:\u003c/p\u003e\u003cul\u003e\u003cli\u003eEnable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;\u003c/li\u003e\u003cli\u003eEnable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and\u003c/li\u003e\u003cli\u003eEnable the \u201cAccess Control List protection,\u201d where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:\u003c/p\u003e\u003cp\u003ehttps://www.se.com/us/en/download/document/SEVD-2017-065-01/\u0026nbsp;\u003c/p\u003e"
            }
          ],
          "value": "Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.\n\n\n\nSchneider Electric\u2019s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:\n\n  *  Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502.\n\n\n\n\nSchneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:\n\n  *  Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;\n  *  Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and\n  *  Enable the \u201cAccess Control List protection,\u201d where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.\n\n\n\n\nFor additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:\n\n\n\nhttps://www.se.com/us/en/download/document/SEVD-2017-065-01/"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6034",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modicon Modbus Protocol",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modicon Modbus Protocol"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-294"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
            },
            {
              "name": "97562",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97562"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6034",
    "datePublished": "2017-06-30T02:35:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2026-06-04T21:07:21.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-6034",
      "date": "2026-06-04",
      "epss": "0.00098",
      "percentile": "0.26855"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-6034\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-06-30T03:29:00.453\",\"lastModified\":\"2026-06-04T22:16:51.503\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema de omisi\u00f3n de autenticaci\u00f3n por captura por reproducci\u00f3n en el protocolo Modicon Modbus, de Schneider Electric. Se transmite informaci\u00f3n sensible en texto claro en el protocolo Modicon Modbus, lo que podr\u00eda permitir que un atacante reproduzca los siguientes comandos: run, stop, upload y download.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modbus_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDF59532-F8A6-4EFC-9B65-7FE1C37B6222\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modbus:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B98D3886-8E25-44A6-9BA0-97274DBE4D39\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/97562\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-101-01.json\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.se.com/us/en/download/document/SEVD-2017-065-01/\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.securityfocus.com/bid/97562\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"http://www.securityfocus.com/bid/97562\", \"name\": \"97562\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T15:18:49.398Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2017-6034\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-28T19:09:00.802921Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-28T19:08:53.847Z\"}}], \"cna\": {\"title\": \"Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay\", \"source\": {\"advisory\": \"ICSA-17-101-01\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Eran Goldstein of CRITIFENCE reported the identified vulnerabilities.\"}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Modicon Modbus Protocol\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2017-06-29T00:00:00.000Z\", \"references\": [{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01\"}, {\"url\": \"http://www.securityfocus.com/bid/97562\", \"name\": \"97562\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\"]}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-101-01.json\"}, {\"url\": \"https://www.se.com/us/en/download/document/SEVD-2017-065-01/\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.\\n\\n\\n\\nSchneider Electric\\u2019s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:\\n\\n  *  Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502.\\n\\n\\n\\n\\nSchneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:\\n\\n  *  Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;\\n  *  Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and\\n  *  Enable the \\u201cAccess Control List protection,\\u201d where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.\\n\\n\\n\\n\\nFor additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:\\n\\n\\n\\nhttps://www.se.com/us/en/download/document/SEVD-2017-065-01/\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eSchneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.\u003c/p\u003e\u003cp\u003eSchneider Electric\\u2019s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:\u003c/p\u003e\u003cul\u003e\u003cli\u003eProtect access to M1E controllers by a firewall blocking all remote/external access to Port 502.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eSchneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:\u003c/p\u003e\u003cul\u003e\u003cli\u003eEnable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;\u003c/li\u003e\u003cli\u003eEnable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and\u003c/li\u003e\u003cli\u003eEnable the \\u201cAccess Control List protection,\\u201d where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:\u003c/p\u003e\u003cp\u003ehttps://www.se.com/us/en/download/document/SEVD-2017-065-01/\u0026nbsp;\u003c/p\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.2\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAn authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-294\", \"description\": \"CWE-294\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2026-06-04T21:07:21.157Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"Schneider Electric Modicon Modbus Protocol\"}]}, \"product_name\": \"Schneider Electric Modicon Modbus Protocol\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01\", \"name\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01\", \"refsource\": \"MISC\"}, {\"url\": \"http://www.securityfocus.com/bid/97562\", \"name\": \"97562\", \"refsource\": \"BID\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-294\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2017-6034\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2017-6034\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-04T21:07:21.157Z\", \"dateReserved\": \"2017-02-16T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2017-06-30T02:35:00.000Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…