Action not permitted
Modal body text goes here.
Modal Title
Modal Body
tid-407
Vulnerability from emb3d
Type
Description
Threat actors may be able to replay a message to a device to cause an unwanted function, send an unwanted command, or gain access to privileged data. Message replaying can be used to bypass nonexistent or poorly designed authentication mechanisms lacking proper protections, such as a nonce or timestamp.
CWE
- CWE-294: Authentication Bypass by Capture-replay (Base)
CVE-2013-2820 (GCVE-0-2013-2820)
Vulnerability from cvelistv5 – Published: 2014-01-15 16:00 – Updated: 2024-08-06 15:52
VLAI
EPSS
Summary
The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.sierrawireless.com/resources/support/a… | x_refsource_CONFIRM |
| http://ics-cert.us-cert.gov/advisories/ICSA-14-007-01A | x_refsource_MISC |
Date Public
2014-01-14 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T15:52:20.770Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.sierrawireless.com/resources/support/airlink/docs/raven%20security%20vulnerability%202014-01-10.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-007-01A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-01-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2014-01-15T16:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.sierrawireless.com/resources/support/airlink/docs/raven%20security%20vulnerability%202014-01-10.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-007-01A"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-2820",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.sierrawireless.com/resources/support/airlink/docs/raven%20security%20vulnerability%202014-01-10.pdf",
"refsource": "CONFIRM",
"url": "http://www.sierrawireless.com/resources/support/airlink/docs/raven%20security%20vulnerability%202014-01-10.pdf"
},
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-007-01A",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-007-01A"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-2820",
"datePublished": "2014-01-15T16:00:00.000Z",
"dateReserved": "2013-04-11T00:00:00.000Z",
"dateUpdated": "2024-08-06T15:52:20.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6034 (GCVE-0-2017-6034)
Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2026-06-04 21:07
VLAI
EPSS
Title
Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
Summary
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
4 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon Modbus Protocol |
Affected:
all versions
|
Date Public
2017-06-29 00:00
Credits
Eran Goldstein of CRITIFENCE reported the identified vulnerabilities.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:18:49.398Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
},
{
"name": "97562",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97562"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2017-6034",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T19:09:00.802921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T19:09:05.551Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon Modbus Protocol",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Eran Goldstein of CRITIFENCE reported the identified vulnerabilities."
}
],
"datePublic": "2017-06-29T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.\u003c/p\u003e"
}
],
"value": "An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-04T21:07:21.157Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
},
{
"name": "97562",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97562"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-101-01.json"
},
{
"url": "https://www.se.com/us/en/download/document/SEVD-2017-065-01/"
}
],
"source": {
"advisory": "ICSA-17-101-01",
"discovery": "UNKNOWN"
},
"title": "Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSchneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.\u003c/p\u003e\u003cp\u003eSchneider Electric\u2019s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:\u003c/p\u003e\u003cul\u003e\u003cli\u003eProtect access to M1E controllers by a firewall blocking all remote/external access to Port 502.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eSchneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:\u003c/p\u003e\u003cul\u003e\u003cli\u003eEnable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;\u003c/li\u003e\u003cli\u003eEnable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and\u003c/li\u003e\u003cli\u003eEnable the \u201cAccess Control List protection,\u201d where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:\u003c/p\u003e\u003cp\u003ehttps://www.se.com/us/en/download/document/SEVD-2017-065-01/\u0026nbsp;\u003c/p\u003e"
}
],
"value": "Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.\n\n\n\nSchneider Electric\u2019s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:\n\n * Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502.\n\n\n\n\nSchneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:\n\n * Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;\n * Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and\n * Enable the \u201cAccess Control List protection,\u201d where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.\n\n\n\n\nFor additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:\n\n\n\nhttps://www.se.com/us/en/download/document/SEVD-2017-065-01/"
}
],
"x_generator": {
"engine": "Vulnogram 1.0.2"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-6034",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric Modicon Modbus Protocol",
"version": {
"version_data": [
{
"version_value": "Schneider Electric Modicon Modbus Protocol"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-294"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
},
{
"name": "97562",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97562"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-6034",
"datePublished": "2017-06-30T02:35:00.000Z",
"dateReserved": "2017-02-16T00:00:00.000Z",
"dateUpdated": "2026-06-04T21:07:21.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…