Search

Find a vulnerability

Search criteria

    780 vulnerabilities by solarwinds

    CVE-2026-28321 (GCVE-0-2026-28321)

    Vulnerability from nvd – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:29
    VLAI
    Title
    SolarWinds Serv-U Broken Access Control Vulnerability
    Summary
    SolarWinds Serv-U is affected by a broken access control vulnerability that could allow arbitrary file read and write, which can then be used to escalate privileges and execute code as root. A domain administrator access is required, and the impact is lower in Windows installations.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28321",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:28:48.551068Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:29:02.375Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that could allow arbitrary file read and write, which can then be used to escalate privileges and execute code as root. A domain administrator access is required, and the impact is lower in Windows installations.\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that could allow arbitrary file read and write, which can then be used to escalate privileges and execute code as root. A domain administrator access is required, and the impact is lower in Windows installations."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-1",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            },
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            },
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:46.561Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28321"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Broken Access Control Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28321",
        "datePublished": "2026-07-21T15:39:46.561Z",
        "dateReserved": "2026-02-26T14:46:41.520Z",
        "dateUpdated": "2026-07-21T17:29:02.375Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28317 (GCVE-0-2026-28317)

    Vulnerability from nvd – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:36
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation. This issue requires domain administrator access. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28317",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:32:58.823221Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:36:54.334Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation. This issue requires domain administrator access. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation. This issue requires domain administrator access. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:30.473Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28317"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28317",
        "datePublished": "2026-07-21T15:39:30.473Z",
        "dateReserved": "2026-02-26T14:46:41.520Z",
        "dateUpdated": "2026-07-21T17:36:54.334Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28316 (GCVE-0-2026-28316)

    Vulnerability from nvd – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:43
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation to a system administrator with the ability to execute commands as the root user. This issue requires a domain account with administrator access. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28316",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:40:11.861053Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:43:16.991Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation to a system administrator with the ability to execute commands as the root user. This issue requires a domain account with administrator access. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation to a system administrator with the ability to execute commands as the root user. This issue requires a domain account with administrator access. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-1",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:17.464Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28316"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28316",
        "datePublished": "2026-07-21T15:39:17.464Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-21T17:43:16.991Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28315 (GCVE-0-2026-28315)

    Vulnerability from nvd – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:44
    VLAI
    Title
    SolarWinds Serv-U Authenticated Stored Cross-site Scripting (XSS) Vulnerability
    Summary
    SolarWinds Serv-U was found to be affected by a stored cross-site scripting vulnerability that could lead to session hijacking or information disclosure from an administrator account.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28315",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:43:48.275527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:44:05.421Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U was found to be affected by a stored cross-site scripting vulnerability that could lead to session hijacking or information disclosure from an administrator account."
                }
              ],
              "value": "SolarWinds Serv-U was found to be affected by a stored cross-site scripting vulnerability that could lead to session hijacking or information disclosure from an administrator account."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:04.982Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28315"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Authenticated Stored Cross-site Scripting (XSS) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28315",
        "datePublished": "2026-07-21T15:39:04.982Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-21T17:44:05.421Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28314 (GCVE-0-2026-28314)

    Vulnerability from nvd – Published: 2026-07-21 15:38 – Updated: 2026-07-22 18:56
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference vulnerability that leads to an account takeover. User authentication is required. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28314",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:56:34.055706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:56:52.533Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference vulnerability that leads to an account takeover. User authentication is required. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference vulnerability that leads to an account takeover. User authentication is required. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:38:39.779Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28314"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28314",
        "datePublished": "2026-07-21T15:38:39.779Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-22T18:56:52.533Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28313 (GCVE-0-2026-28313)

    Vulnerability from nvd – Published: 2026-07-21 15:38 – Updated: 2026-07-22 18:56
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to SMTP hijacking leading to arbitrary account takeover. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28313",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:56:08.586073Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:56:21.200Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to SMTP hijacking leading to arbitrary account takeover. The impact is lower in Windows deployments.\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to SMTP hijacking leading to arbitrary account takeover. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:38:22.855Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28313"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28313",
        "datePublished": "2026-07-21T15:38:22.855Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-22T18:56:21.200Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28312 (GCVE-0-2026-28312)

    Vulnerability from nvd – Published: 2026-07-21 15:37 – Updated: 2026-07-22 18:55
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability. This would elevate a group’s access to system administrator and allow code execution as root. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28312",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:55:44.817470Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:55:54.782Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability. This would elevate a group\u2019s access to system administrator and allow code execution as root. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability. This would elevate a group\u2019s access to system administrator and allow code execution as root. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "CWE-285 Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:37:45.518Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28312"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28312",
        "datePublished": "2026-07-21T15:37:45.518Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:55:54.782Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28310 (GCVE-0-2026-28310)

    Vulnerability from nvd – Published: 2026-07-21 15:35 – Updated: 2026-07-22 18:55
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to escalate their user type to that of a system administrator. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28310",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:53:22.862094Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:55:10.064Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to escalate their user type to that of a system administrator. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to escalate their user type to that of a system administrator. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:35:07.899Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28310"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28310",
        "datePublished": "2026-07-21T15:35:07.899Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:55:10.064Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28309 (GCVE-0-2026-28309)

    Vulnerability from nvd – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:52
    VLAI
    Title
    SolarWinds Serv-U Broken Access Control Vulnerability
    Summary
    SolarWinds Serv-U is affected by a broken access control vulnerability that allows a domain administrator to create system administrator accounts. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28309",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:48:55.355236Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:52:22.472Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that allows a domain administrator to create system administrator accounts. The impact is lower in Windows deployments.\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that allows a domain administrator to create system administrator accounts. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:52.384Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28309"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SolarWinds Serv-U Broken Access Control Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28309",
        "datePublished": "2026-07-21T15:34:52.384Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:52:22.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28308 (GCVE-0-2026-28308)

    Vulnerability from nvd – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:48
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution. Domain administrator access is required. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28308",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:48:21.222226Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:48:30.162Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution. Domain administrator access is required. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution. Domain administrator access is required. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:40.127Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28308"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28308",
        "datePublished": "2026-07-21T15:34:40.127Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:48:30.162Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28307 (GCVE-0-2026-28307)

    Vulnerability from nvd – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:47
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain user group to be elevated into an administrator group. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28307",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:47:28.828729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:47:55.014Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain user group to be elevated into an administrator group. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain user group to be elevated into an administrator group. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:26.779Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28307"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28307",
        "datePublished": "2026-07-21T15:34:26.779Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:47:55.014Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28306 (GCVE-0-2026-28306)

    Vulnerability from nvd – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:08
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to elevate their privileges to a system administrator. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28306",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:08:48.819860Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:08:56.676Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to elevate their privileges to a system administrator. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to elevate their privileges to a system administrator. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:09.400Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28306"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28306",
        "datePublished": "2026-07-21T15:34:09.400Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-22T18:08:56.676Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28305 (GCVE-0-2026-28305)

    Vulnerability from nvd – Published: 2026-07-21 15:33 – Updated: 2026-07-22 18:09
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution as root. A domain account with admin privileges and read and write access to the home directory is required. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28305",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:09:16.932890Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:09:44.303Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution as root. A domain account with admin privileges and read and write access to the home directory is required. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution as root. A domain account with admin privileges and read and write access to the home directory is required. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:33:55.983Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28305"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28305",
        "datePublished": "2026-07-21T15:33:55.983Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-22T18:09:44.303Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28304 (GCVE-0-2026-28304)

    Vulnerability from nvd – Published: 2026-07-21 15:32 – Updated: 2026-07-21 18:33
    VLAI
    Title
    SolarWinds Serv-U Remote Code Execution Vulnerability
    Summary
    SolarWinds Serv-U is affected by a remote code execution vulnerability that, when exploited, can allow the arbitrary execution of code remotely as root. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28304",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T18:29:27.848079Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T18:33:01.893Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a remote code execution vulnerability that, when exploited, can allow the arbitrary execution of code remotely as root. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a remote code execution vulnerability that, when exploited, can allow the arbitrary execution of code remotely as root. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:32:04.741Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28304"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Remote Code Execution Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28304",
        "datePublished": "2026-07-21T15:32:04.741Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-21T18:33:01.893Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28302 (GCVE-0-2026-28302)

    Vulnerability from nvd – Published: 2026-07-21 15:31 – Updated: 2026-07-22 18:27
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation and remote code execution as root. This issue requires group administrator access. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28302",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:15:12.614047Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:27:29.390Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation and remote code execution as root. This issue requires group administrator access. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation and remote code execution as root. This issue requires group administrator access. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:31:30.297Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28302"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28302",
        "datePublished": "2026-07-21T15:31:30.297Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-22T18:27:29.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28321 (GCVE-0-2026-28321)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:29
    VLAI
    Title
    SolarWinds Serv-U Broken Access Control Vulnerability
    Summary
    SolarWinds Serv-U is affected by a broken access control vulnerability that could allow arbitrary file read and write, which can then be used to escalate privileges and execute code as root. A domain administrator access is required, and the impact is lower in Windows installations.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28321",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:28:48.551068Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:29:02.375Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that could allow arbitrary file read and write, which can then be used to escalate privileges and execute code as root. A domain administrator access is required, and the impact is lower in Windows installations.\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that could allow arbitrary file read and write, which can then be used to escalate privileges and execute code as root. A domain administrator access is required, and the impact is lower in Windows installations."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-1",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            },
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            },
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:46.561Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28321"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Broken Access Control Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28321",
        "datePublished": "2026-07-21T15:39:46.561Z",
        "dateReserved": "2026-02-26T14:46:41.520Z",
        "dateUpdated": "2026-07-21T17:29:02.375Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28317 (GCVE-0-2026-28317)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:36
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation. This issue requires domain administrator access. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28317",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:32:58.823221Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:36:54.334Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation. This issue requires domain administrator access. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation. This issue requires domain administrator access. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:30.473Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28317"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28317",
        "datePublished": "2026-07-21T15:39:30.473Z",
        "dateReserved": "2026-02-26T14:46:41.520Z",
        "dateUpdated": "2026-07-21T17:36:54.334Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28316 (GCVE-0-2026-28316)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:43
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation to a system administrator with the ability to execute commands as the root user. This issue requires a domain account with administrator access. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28316",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:40:11.861053Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:43:16.991Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation to a system administrator with the ability to execute commands as the root user. This issue requires a domain account with administrator access. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation to a system administrator with the ability to execute commands as the root user. This issue requires a domain account with administrator access. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-1",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:17.464Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28316"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28316",
        "datePublished": "2026-07-21T15:39:17.464Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-21T17:43:16.991Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28315 (GCVE-0-2026-28315)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:39 – Updated: 2026-07-21 17:44
    VLAI
    Title
    SolarWinds Serv-U Authenticated Stored Cross-site Scripting (XSS) Vulnerability
    Summary
    SolarWinds Serv-U was found to be affected by a stored cross-site scripting vulnerability that could lead to session hijacking or information disclosure from an administrator account.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28315",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T17:43:48.275527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T17:44:05.421Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U was found to be affected by a stored cross-site scripting vulnerability that could lead to session hijacking or information disclosure from an administrator account."
                }
              ],
              "value": "SolarWinds Serv-U was found to be affected by a stored cross-site scripting vulnerability that could lead to session hijacking or information disclosure from an administrator account."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:39:04.982Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28315"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Authenticated Stored Cross-site Scripting (XSS) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28315",
        "datePublished": "2026-07-21T15:39:04.982Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-21T17:44:05.421Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28314 (GCVE-0-2026-28314)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:38 – Updated: 2026-07-22 18:56
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference vulnerability that leads to an account takeover. User authentication is required. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28314",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:56:34.055706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:56:52.533Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference vulnerability that leads to an account takeover. User authentication is required. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference vulnerability that leads to an account takeover. User authentication is required. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:38:39.779Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28314"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28314",
        "datePublished": "2026-07-21T15:38:39.779Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-22T18:56:52.533Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28313 (GCVE-0-2026-28313)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:38 – Updated: 2026-07-22 18:56
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to SMTP hijacking leading to arbitrary account takeover. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28313",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:56:08.586073Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:56:21.200Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to SMTP hijacking leading to arbitrary account takeover. The impact is lower in Windows deployments.\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to SMTP hijacking leading to arbitrary account takeover. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:38:22.855Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28313"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28313",
        "datePublished": "2026-07-21T15:38:22.855Z",
        "dateReserved": "2026-02-26T14:28:17.158Z",
        "dateUpdated": "2026-07-22T18:56:21.200Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28312 (GCVE-0-2026-28312)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:37 – Updated: 2026-07-22 18:55
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability. This would elevate a group’s access to system administrator and allow code execution as root. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28312",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:55:44.817470Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:55:54.782Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability. This would elevate a group\u2019s access to system administrator and allow code execution as root. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability. This would elevate a group\u2019s access to system administrator and allow code execution as root. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "CWE-285 Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:37:45.518Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28312"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28312",
        "datePublished": "2026-07-21T15:37:45.518Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:55:54.782Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28310 (GCVE-0-2026-28310)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:35 – Updated: 2026-07-22 18:55
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to escalate their user type to that of a system administrator. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28310",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:53:22.862094Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:55:10.064Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to escalate their user type to that of a system administrator. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to escalate their user type to that of a system administrator. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:35:07.899Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28310"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28310",
        "datePublished": "2026-07-21T15:35:07.899Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:55:10.064Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28309 (GCVE-0-2026-28309)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:52
    VLAI
    Title
    SolarWinds Serv-U Broken Access Control Vulnerability
    Summary
    SolarWinds Serv-U is affected by a broken access control vulnerability that allows a domain administrator to create system administrator accounts. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28309",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:48:55.355236Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:52:22.472Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that allows a domain administrator to create system administrator accounts. The impact is lower in Windows deployments.\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds Serv-U is affected by a broken access control vulnerability that allows a domain administrator to create system administrator accounts. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:52.384Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28309"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SolarWinds Serv-U Broken Access Control Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28309",
        "datePublished": "2026-07-21T15:34:52.384Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:52:22.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28308 (GCVE-0-2026-28308)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:48
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution. Domain administrator access is required. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28308",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:48:21.222226Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:48:30.162Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution. Domain administrator access is required. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution. Domain administrator access is required. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:40.127Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28308"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28308",
        "datePublished": "2026-07-21T15:34:40.127Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:48:30.162Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28307 (GCVE-0-2026-28307)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:47
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain user group to be elevated into an administrator group. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28307",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:47:28.828729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:47:55.014Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain user group to be elevated into an administrator group. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain user group to be elevated into an administrator group. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:26.779Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28307"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28307",
        "datePublished": "2026-07-21T15:34:26.779Z",
        "dateReserved": "2026-02-26T14:28:17.157Z",
        "dateUpdated": "2026-07-22T18:47:55.014Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28306 (GCVE-0-2026-28306)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:34 – Updated: 2026-07-22 18:08
    VLAI
    Title
    SolarWinds Serv-U Privilege Escalation Vulnerability
    Summary
    SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to elevate their privileges to a system administrator. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28306",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:08:48.819860Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:08:56.676Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to elevate their privileges to a system administrator. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a privilege escalation vulnerability that allows a domain administrator to elevate their privileges to a system administrator. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:34:09.400Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28306"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SolarWinds Serv-U Privilege Escalation Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28306",
        "datePublished": "2026-07-21T15:34:09.400Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-22T18:08:56.676Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28305 (GCVE-0-2026-28305)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:33 – Updated: 2026-07-22 18:09
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution as root. A domain account with admin privileges and read and write access to the home directory is required. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28305",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:09:16.932890Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:09:44.303Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution as root. A domain account with admin privileges and read and write access to the home directory is required. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to remote code execution as root. A domain account with admin privileges and read and write access to the home directory is required. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:33:55.983Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28305"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical.\n\n\u003cbr\u003e"
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28305",
        "datePublished": "2026-07-21T15:33:55.983Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-22T18:09:44.303Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28304 (GCVE-0-2026-28304)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:32 – Updated: 2026-07-21 18:33
    VLAI
    Title
    SolarWinds Serv-U Remote Code Execution Vulnerability
    Summary
    SolarWinds Serv-U is affected by a remote code execution vulnerability that, when exploited, can allow the arbitrary execution of code remotely as root. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28304",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-21T18:29:27.848079Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-21T18:33:01.893Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by a remote code execution vulnerability that, when exploited, can allow the arbitrary execution of code remotely as root. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by a remote code execution vulnerability that, when exploited, can allow the arbitrary execution of code remotely as root. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:32:04.741Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28304"
            },
            {
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
                }
              ],
              "value": "SolarWinds recommends customers to upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Remote Code Execution Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28304",
        "datePublished": "2026-07-21T15:32:04.741Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-21T18:33:01.893Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28302 (GCVE-0-2026-28302)

    Vulnerability from cvelistv5 – Published: 2026-07-21 15:31 – Updated: 2026-07-22 18:27
    VLAI
    Title
    SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability
    Summary
    SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation and remote code execution as root. This issue requires group administrator access. The impact is lower in Windows deployments.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization Bypass Through User-Controlled Key
    Assigner
    Impacted products
    Vendor Product Version
    SolarWinds Serv-U Affected: 15.5.4 HF1 and below
    Create a notification for this product.
    Credits
    Intigriti Bug Bounty Program
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-28302",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-22T18:15:12.614047Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-22T18:27:29.390Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux"
              ],
              "product": "Serv-U",
              "vendor": "SolarWinds",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.5.4 HF1 and below"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Intigriti Bug Bounty Program"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation and remote code execution as root. This issue requires group administrator access. The impact is lower in Windows deployments."
                }
              ],
              "value": "SolarWinds Serv-U is affected by an insecure direct object reference (IDOR) vulnerability that can lead to privilege escalation and remote code execution as root. This issue requires group administrator access. The impact is lower in Windows deployments."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Linux"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Serv-U Windows"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-21T15:31:30.297Z",
            "orgId": "49f11609-934d-4621-84e6-e02e032104d6",
            "shortName": "SolarWinds"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2026-28302"
            },
            {
              "tags": [
                "release-notes"
              ],
              "url": "https://documentation.solarwinds.com/en/success_center/servu/content/release_notes/servu_2026-3_release_notes.htm"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
                }
              ],
              "value": "SolarWinds recommends customers upgrade to Serv-U version 2026.3 as soon as is practical."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "SolarWinds Serv-U Insecure Direct Object Reference (IDOR) Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
        "assignerShortName": "SolarWinds",
        "cveId": "CVE-2026-28302",
        "datePublished": "2026-07-21T15:31:30.297Z",
        "dateReserved": "2026-02-26T14:15:09.403Z",
        "dateUpdated": "2026-07-22T18:27:29.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }