Search
Find a vulnerability
Search criteria
32 vulnerabilities by mercedes-benz
CVE-2024-37603 (GCVE-0-2024-37603)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:08
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37603",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T14:08:04.038137Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T14:08:30.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:11:58.317Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37603",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-18T14:08:30.182Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37602 (GCVE-0-2024-37602)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-02-14 16:27
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible NULL pointer dereference in the Apple Car Play function affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the AirTunes / AirPlay service. With prepared HTTP requests, an attacker can cause the Car Play service to fail.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37602",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:27:23.258773Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-14T16:27:59.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible NULL pointer dereference in the Apple Car Play function affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the AirTunes / AirPlay service. With prepared HTTP requests, an attacker can cause the Car Play service to fail."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:P/A:H/C:N/I:N/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:10:24.994Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37602",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-14T16:27:59.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37601 (GCVE-0-2024-37601)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:07
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible heap buffer overflow exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T14:07:47.658156Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T14:07:50.678Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible heap buffer overflow exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:12:29.793Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37601",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-18T14:07:50.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37600 (GCVE-0-2024-37600)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:06
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible stack buffer overflow in the Service Broker service affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the Service Broker service. With prepared HTTP requests, an attacker can cause the Service-Broker service to fail.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37600",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T14:06:42.954959Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T14:06:45.658Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible stack buffer overflow in the Service Broker service affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the Service Broker service. With prepared HTTP requests, an attacker can cause the Service-Broker service to fail."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:P/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:11:07.082Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37600",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-18T14:06:45.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34406 (GCVE-0-2023-34406)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-17 18:50
VLAI
Summary
An issue was discovered on Mercedes Benz NTG 6. A possible integer overflow exists in the user data import/export function of NTG (New Telematics Generation) 6 head units. To perform this attack, local access to USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34406",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:09:33.928428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T18:50:53.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mercedes Benz NTG 6. A possible integer overflow exists in the user data import/export function of NTG (New Telematics Generation) 6 head units. To perform this attack, local access to USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:13:32.611Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34406",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-17T18:50:53.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34404 (GCVE-0-2023-34404)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-17 18:52
VLAI
Summary
Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to these pins and get access to internal network. As a result, by accessing a specific port an attacker can send call request to all registered services in router and achieve command injection vulnerability.
Severity
4.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34404",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:10:34.736632Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T18:52:06.921Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to these pins and get access to internal network. As a result, by accessing a specific port an attacker can send call request to all registered services in router and achieve command injection vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:09:27.023Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34404",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-17T18:52:06.921Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34403 (GCVE-0-2023-34403)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-18 16:11
VLAI
Summary
Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to this pins and get access to internal network. A race condition can be acquired and attacker can spoof “UserData” with desirable file path and access it though backup on USB.
Severity
4.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34403",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:10:58.180428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T16:11:03.215Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to this pins and get access to internal network. A race condition can be acquired and attacker can spoof \u201cUserData\u201d with desirable file path and access it though backup on USB."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:08:39.606Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34403",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T16:11:03.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34402 (GCVE-0-2023-34402)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-14 17:24
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside file is encapsulate another file, which service will drop during processing. Due to missed checks, attacker can achieve Arbitrary File Write with service speech rights.
Severity
7.7 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:24:21.924867Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T17:24:26.958Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside file is encapsulate another file, which service will drop during processing. Due to missed checks, attacker can achieve Arbitrary File Write with service speech rights."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:07:42.679Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34402",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-14T17:24:26.958Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34401 (GCVE-0-2023-34401)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-18 16:08
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside profile folder there is a file, which is encoded with proprietary UD2 codec. Due to missed size checks in the enapsulate file, attacker can achieve Out-of-Bound Read in heap memory.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34401",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T18:27:37.760672Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T16:08:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside profile folder there is a file, which is encoded with proprietary UD2 codec. Due to missed size checks in the enapsulate file, attacker can achieve Out-of-Bound Read in heap memory."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:06:21.369Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34401",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T16:08:57.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34400 (GCVE-0-2023-34400)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-18 19:48
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. In case of parsing file, service try to define header inside the file and convert it to null-terminated string. If character is missed, will return null pointer.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-18T19:47:32.601607Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T19:48:07.124Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. In case of parsing file, service try to define header inside the file and convert it to null-terminated string. If character is missed, will return null pointer."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:05:18.827Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34400",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T19:48:07.124Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34399 (GCVE-0-2023-34399)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-24 16:10
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The version of boost library contains vulnerability integer overflow.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:34:46.721415Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T16:10:35.701Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The version of boost library contains vulnerability integer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:04:13.136Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34399",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-24T16:10:35.701Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34398 (GCVE-0-2023-34398)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-18 18:07
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The boost library contains a vulnerability/null pointer dereference.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34398",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:36:57.465635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T18:07:36.866Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The boost library contains a vulnerability/null pointer dereference."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:02:55.609Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34398",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T18:07:36.866Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34397 (GCVE-0-2023-34397)
Vulnerability from nvd – Published: 2025-02-13 00:00 – Updated: 2025-03-24 16:38
VLAI
Summary
Mercedes Benz head-unit NTG 6 contains functions to import or export profile settings over USB. During parsing you can trigger that the service will be crashed.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:38:54.464328Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T16:38:44.627Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes Benz head-unit NTG 6 contains functions to import or export profile settings over USB. During parsing you can trigger that the service will be crashed."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:02:00.908Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34397",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-24T16:38:44.627Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-47393 (GCVE-0-2023-47393)
Vulnerability from nvd – Published: 2023-11-22 00:00 – Updated: 2024-09-04 18:42
VLAI
Summary
An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the maintenance orders of other users and access sensitive user information via unspecified vectors.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:09:37.512Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/wwwziziyu/7dbf7fd43f9e304ce0819f8a9784d2c6"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-47393",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-04T18:40:50.422465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-04T18:42:15.854Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the maintenance orders of other users and access sensitive user information via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-22T06:52:26.333Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://gist.github.com/wwwziziyu/7dbf7fd43f9e304ce0819f8a9784d2c6"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-47393",
"datePublished": "2023-11-22T00:00:00.000Z",
"dateReserved": "2023-11-06T00:00:00.000Z",
"dateUpdated": "2024-09-04T18:42:15.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-47392 (GCVE-0-2023-47392)
Vulnerability from nvd – Published: 2023-11-22 00:00 – Updated: 2024-08-29 19:54
VLAI
Summary
An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the carts of other users via sending a crafted add order request.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:09:37.436Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/wwwziziyu/d0ae135b8075f6db735d75135254e7a1"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-47392",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T19:53:09.077429Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T19:54:08.745Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the carts of other users via sending a crafted add order request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-22T06:52:30.589Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://gist.github.com/wwwziziyu/d0ae135b8075f6db735d75135254e7a1"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-47392",
"datePublished": "2023-11-22T00:00:00.000Z",
"dateReserved": "2023-11-06T00:00:00.000Z",
"dateUpdated": "2024-08-29T19:54:08.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37603 (GCVE-0-2024-37603)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:08
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37603",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T14:08:04.038137Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T14:08:30.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:11:58.317Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37603",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-18T14:08:30.182Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34397 (GCVE-0-2023-34397)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-24 16:38
VLAI
Summary
Mercedes Benz head-unit NTG 6 contains functions to import or export profile settings over USB. During parsing you can trigger that the service will be crashed.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:38:54.464328Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T16:38:44.627Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes Benz head-unit NTG 6 contains functions to import or export profile settings over USB. During parsing you can trigger that the service will be crashed."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:02:00.908Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34397",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-24T16:38:44.627Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34406 (GCVE-0-2023-34406)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-17 18:50
VLAI
Summary
An issue was discovered on Mercedes Benz NTG 6. A possible integer overflow exists in the user data import/export function of NTG (New Telematics Generation) 6 head units. To perform this attack, local access to USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34406",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:09:33.928428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T18:50:53.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mercedes Benz NTG 6. A possible integer overflow exists in the user data import/export function of NTG (New Telematics Generation) 6 head units. To perform this attack, local access to USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:13:32.611Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34406",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-17T18:50:53.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37602 (GCVE-0-2024-37602)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-02-14 16:27
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible NULL pointer dereference in the Apple Car Play function affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the AirTunes / AirPlay service. With prepared HTTP requests, an attacker can cause the Car Play service to fail.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37602",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:27:23.258773Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-14T16:27:59.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible NULL pointer dereference in the Apple Car Play function affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the AirTunes / AirPlay service. With prepared HTTP requests, an attacker can cause the Car Play service to fail."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:P/A:H/C:N/I:N/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:10:24.994Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37602",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-14T16:27:59.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34400 (GCVE-0-2023-34400)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-18 19:48
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. In case of parsing file, service try to define header inside the file and convert it to null-terminated string. If character is missed, will return null pointer.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-18T19:47:32.601607Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T19:48:07.124Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. In case of parsing file, service try to define header inside the file and convert it to null-terminated string. If character is missed, will return null pointer."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:05:18.827Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34400",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T19:48:07.124Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37601 (GCVE-0-2024-37601)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:07
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible heap buffer overflow exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
Severity
4.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T14:07:47.658156Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T14:07:50.678Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible heap buffer overflow exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:12:29.793Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37601",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-18T14:07:50.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34403 (GCVE-0-2023-34403)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-18 16:11
VLAI
Summary
Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to this pins and get access to internal network. A race condition can be acquired and attacker can spoof “UserData” with desirable file path and access it though backup on USB.
Severity
4.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34403",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:10:58.180428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T16:11:03.215Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to this pins and get access to internal network. A race condition can be acquired and attacker can spoof \u201cUserData\u201d with desirable file path and access it though backup on USB."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:08:39.606Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34403",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T16:11:03.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34404 (GCVE-0-2023-34404)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-17 18:52
VLAI
Summary
Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to these pins and get access to internal network. As a result, by accessing a specific port an attacker can send call request to all registered services in router and achieve command injection vulnerability.
Severity
4.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34404",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:10:34.736632Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-17T18:52:06.921Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to these pins and get access to internal network. As a result, by accessing a specific port an attacker can send call request to all registered services in router and achieve command injection vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:09:27.023Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34404",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-17T18:52:06.921Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34398 (GCVE-0-2023-34398)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-18 18:07
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The boost library contains a vulnerability/null pointer dereference.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34398",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:36:57.465635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T18:07:36.866Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The boost library contains a vulnerability/null pointer dereference."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:02:55.609Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34398",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T18:07:36.866Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34402 (GCVE-0-2023-34402)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-14 17:24
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside file is encapsulate another file, which service will drop during processing. Due to missed checks, attacker can achieve Arbitrary File Write with service speech rights.
Severity
7.7 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34402",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:24:21.924867Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T17:24:26.958Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside file is encapsulate another file, which service will drop during processing. Due to missed checks, attacker can achieve Arbitrary File Write with service speech rights."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:07:42.679Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34402",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-14T17:24:26.958Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34399 (GCVE-0-2023-34399)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-24 16:10
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The version of boost library contains vulnerability integer overflow.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T16:34:46.721415Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190 Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-24T16:10:35.701Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Some values of this table are serialized archive according boost library. The version of boost library contains vulnerability integer overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:04:13.136Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34399",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-24T16:10:35.701Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34401 (GCVE-0-2023-34401)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-03-18 16:08
VLAI
Summary
Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside profile folder there is a file, which is encoded with proprietary UD2 codec. Due to missed size checks in the enapsulate file, attacker can achieve Out-of-Bound Read in heap memory.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34401",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T18:27:37.760672Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T16:08:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mercedes-Benz head-unit NTG6 contains functions to import or export profile settings over USB. Inside profile folder there is a file, which is encoded with proprietary UD2 codec. Due to missed size checks in the enapsulate file, attacker can achieve Out-of-Bound Read in heap memory."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:06:21.369Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34401",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2023-06-05T00:00:00.000Z",
"dateUpdated": "2025-03-18T16:08:57.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37600 (GCVE-0-2024-37600)
Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:06
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible stack buffer overflow in the Service Broker service affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the Service Broker service. With prepared HTTP requests, an attacker can cause the Service-Broker service to fail.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37600",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-18T14:06:42.954959Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-18T14:06:45.658Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6 through 2021. A possible stack buffer overflow in the Service Broker service affects NTG 6 head units. To perform this attack, physical access to Ethernet pins of the head unit base board is needed. With a static IP address, an attacker can connect via the internal network to the Service Broker service. With prepared HTTP requests, an attacker can cause the Service-Broker service to fail."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:P/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T22:11:07.082Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37600",
"datePublished": "2025-02-13T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2025-02-18T14:06:45.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-47392 (GCVE-0-2023-47392)
Vulnerability from cvelistv5 – Published: 2023-11-22 00:00 – Updated: 2024-08-29 19:54
VLAI
Summary
An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the carts of other users via sending a crafted add order request.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:09:37.436Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/wwwziziyu/d0ae135b8075f6db735d75135254e7a1"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-47392",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T19:53:09.077429Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T19:54:08.745Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the carts of other users via sending a crafted add order request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-22T06:52:30.589Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://gist.github.com/wwwziziyu/d0ae135b8075f6db735d75135254e7a1"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-47392",
"datePublished": "2023-11-22T00:00:00.000Z",
"dateReserved": "2023-11-06T00:00:00.000Z",
"dateUpdated": "2024-08-29T19:54:08.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-47393 (GCVE-0-2023-47393)
Vulnerability from cvelistv5 – Published: 2023-11-22 00:00 – Updated: 2024-09-04 18:42
VLAI
Summary
An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the maintenance orders of other users and access sensitive user information via unspecified vectors.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:09:37.512Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/wwwziziyu/7dbf7fd43f9e304ce0819f8a9784d2c6"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-47393",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-04T18:40:50.422465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-04T18:42:15.854Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Mercedes me IOS APP v1.34.0 and below allows attackers to view the maintenance orders of other users and access sensitive user information via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-22T06:52:26.333Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://gist.github.com/wwwziziyu/7dbf7fd43f9e304ce0819f8a9784d2c6"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-47393",
"datePublished": "2023-11-22T00:00:00.000Z",
"dateReserved": "2023-11-06T00:00:00.000Z",
"dateUpdated": "2024-09-04T18:42:15.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}