Search

Find a vulnerability

Search criteria

    3 vulnerabilities by blipcare

    VAR-201907-1043

    Vulnerability from variot - Updated: 2025-01-30 19:39

    It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack. There is a security flaw in the Blipcare device

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1043",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wi-fi blood pressure monitor",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "blipcare",
            "version": "bp700_10.1"
          },
          {
            "model": "wifi blood pressure monitor",
            "scope": null,
            "trust": 0.8,
            "vendor": "blipcare",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:blipcare:wi-fi_blood_pressure_monitor_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Mandar Satam",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "153225"
          }
        ],
        "trust": 0.1
      },
      "cve": "CVE-2017-11578",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2017-11578",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-102014",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.2,
                "id": "CVE-2017-11578",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-11578",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-11578",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201707-1028",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-102014",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2017-11578",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack. There is a security flaw in the Blipcare device",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11578"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-11578",
            "trust": 2.8
          },
          {
            "db": "PACKETSTORM",
            "id": "153225",
            "trust": 1.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028",
            "trust": 0.7
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-102014",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11578",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "id": "VAR-201907-1043",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          }
        ],
        "trust": 0.02
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "medical device"
            ],
            "sub_category": "blood pressure monitor",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ]
      },
      "last_update_date": "2025-01-30T19:39:08.336000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Wi-Fi Blood Pressure Monitor",
            "trust": 0.8,
            "url": "http://www.blipcare.com/blip-bp.html"
          },
          {
            "title": "Blipcare Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=94346"
          },
          {
            "title": "IoT_vulnerabilities",
            "trust": 0.1,
            "url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/blipcare_sec_issues.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://seclists.org/bugtraq/2019/jun/8"
          },
          {
            "trust": 1.8,
            "url": "http://packetstormsecurity.com/files/153225/blipcare-clear-text-communication-memory-corruption.html"
          },
          {
            "trust": 1.5,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11578"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11578"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/200.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/ethanhunnt/iot_vulnerabilities"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11580"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11579"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "date": "2019-07-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "date": "2019-07-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "date": "2019-06-07T15:06:02",
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "date": "2017-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          },
          {
            "date": "2019-07-02T21:15:09.870000",
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-15T00:00:00",
            "db": "VULHUB",
            "id": "VHN-102014"
          },
          {
            "date": "2019-07-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-11578"
          },
          {
            "date": "2019-07-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          },
          {
            "date": "2019-07-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          },
          {
            "date": "2024-11-21T03:08:04.020000",
            "db": "NVD",
            "id": "CVE-2017-11578"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Blipcare Wireless Blood pressure monitor Vulnerable to information disclosure",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014575"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1028"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201907-1044

    Vulnerability from variot - Updated: 2024-11-23 22:16

    In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware. There is a security flaw in the Blipcare device. Remote attackers can use this vulnerability to sniff credentials, modify HTTP responses, and perform other attacks (for example, tricking users into downloading and executing malicious binary files)

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1044",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wi-fi blood pressure monitor",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "blipcare",
            "version": "bp700_10.1"
          },
          {
            "model": "wifi blood pressure monitor",
            "scope": null,
            "trust": 0.8,
            "vendor": "blipcare",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:blipcare:wi-fi_blood_pressure_monitor_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Mandar Satam",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "153225"
          }
        ],
        "trust": 0.1
      },
      "cve": "CVE-2017-11579",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2017-11579",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "VHN-102015",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-11579",
                "impactScore": 4.2,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-11579",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-11579",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201707-1027",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-102015",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2017-11579",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware. There is a security flaw in the Blipcare device. Remote attackers can use this vulnerability to sniff credentials, modify HTTP responses, and perform other attacks (for example, tricking users into downloading and executing malicious binary files)",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11579"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-11579",
            "trust": 2.7
          },
          {
            "db": "PACKETSTORM",
            "id": "153225",
            "trust": 1.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-102015",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11579",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "id": "VAR-201907-1044",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T22:16:57.059000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Wi-Fi Blood Pressure Monitor",
            "trust": 0.8,
            "url": "http://www.blipcare.com/blip-bp.html"
          },
          {
            "title": "Blipcare Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=94345"
          },
          {
            "title": "IoT_vulnerabilities",
            "trust": 0.1,
            "url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-254",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/blipcare_sec_issues.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://seclists.org/bugtraq/2019/jun/8"
          },
          {
            "trust": 1.8,
            "url": "http://packetstormsecurity.com/files/153225/blipcare-clear-text-communication-memory-corruption.html"
          },
          {
            "trust": 1.5,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11579"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11579"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/254.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/ethanhunnt/iot_vulnerabilities"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11580"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11578"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "date": "2019-07-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "date": "2019-07-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "date": "2019-06-07T15:06:02",
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "date": "2017-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          },
          {
            "date": "2019-07-02T21:15:09.930000",
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-15T00:00:00",
            "db": "VULHUB",
            "id": "VHN-102015"
          },
          {
            "date": "2019-07-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-11579"
          },
          {
            "date": "2019-07-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          },
          {
            "date": "2019-07-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          },
          {
            "date": "2024-11-21T03:08:04.190000",
            "db": "NVD",
            "id": "CVE-2017-11579"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Blipcare Wireless Blood pressure monitor Vulnerabilities related to security functions",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014574"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "security feature problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1027"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201907-1045

    Vulnerability from variot - Updated: 2024-11-23 22:16

    Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1045",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wi-fi blood pressure monitor",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "blipcare",
            "version": "bp700_10.1"
          },
          {
            "model": "wifi blood pressure monitor",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "blipcare",
            "version": "bp700 10.1"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:blipcare:wi-fi_blood_pressure_monitor_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Mandar Satam",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "153225"
          }
        ],
        "trust": 0.1
      },
      "cve": "CVE-2017-11580",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CVE-2017-11580",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "VHN-102017",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-11580",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-11580",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-11580",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201707-1026",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-102017",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2017-11580",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11580"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-11580",
            "trust": 2.7
          },
          {
            "db": "PACKETSTORM",
            "id": "153225",
            "trust": 1.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-102017",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11580",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "id": "VAR-201907-1045",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T22:16:57.026000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Wi-Fi Blood Pressure Monitor",
            "trust": 0.8,
            "url": "http://www.blipcare.com/blip-bp.html"
          },
          {
            "title": "Blipcare Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=94344"
          },
          {
            "title": "IoT_vulnerabilities",
            "trust": 0.1,
            "url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-399",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/blipcare_sec_issues.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://seclists.org/bugtraq/2019/jun/8"
          },
          {
            "trust": 1.8,
            "url": "http://packetstormsecurity.com/files/153225/blipcare-clear-text-communication-memory-corruption.html"
          },
          {
            "trust": 1.5,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11580"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11580"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/399.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/ethanhunnt/iot_vulnerabilities"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11578"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11579"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "date": "2019-07-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "date": "2019-07-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "date": "2019-06-07T15:06:02",
            "db": "PACKETSTORM",
            "id": "153225"
          },
          {
            "date": "2017-07-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          },
          {
            "date": "2019-07-02T21:15:10.010000",
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-15T00:00:00",
            "db": "VULHUB",
            "id": "VHN-102017"
          },
          {
            "date": "2019-07-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-11580"
          },
          {
            "date": "2019-07-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          },
          {
            "date": "2019-07-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          },
          {
            "date": "2024-11-21T03:08:04.350000",
            "db": "NVD",
            "id": "CVE-2017-11580"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Blipcare Wifi blood pressure monitor Vulnerabilities related to resource management in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-014573"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "resource management error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201707-1026"
          }
        ],
        "trust": 0.6
      }
    }