VAR-201907-1044

Vulnerability from variot - Updated: 2024-11-23 22:16

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware. There is a security flaw in the Blipcare device. Remote attackers can use this vulnerability to sniff credentials, modify HTTP responses, and perform other attacks (for example, tricking users into downloading and executing malicious binary files)

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1044",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wi-fi blood pressure monitor",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "blipcare",
        "version": "bp700_10.1"
      },
      {
        "model": "wifi blood pressure monitor",
        "scope": null,
        "trust": 0.8,
        "vendor": "blipcare",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:blipcare:wi-fi_blood_pressure_monitor_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mandar Satam",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "153225"
      }
    ],
    "trust": 0.1
  },
  "cve": "CVE-2017-11579",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-11579",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "VHN-102015",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:P/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-11579",
            "impactScore": 4.2,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-11579",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-11579",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201707-1027",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-102015",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-11579",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware. There is a security flaw in the Blipcare device. Remote attackers can use this vulnerability to sniff credentials, modify HTTP responses, and perform other attacks (for example, tricking users into downloading and executing malicious binary files)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11579"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-11579",
        "trust": 2.7
      },
      {
        "db": "PACKETSTORM",
        "id": "153225",
        "trust": 1.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-102015",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11579",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "id": "VAR-201907-1044",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-11-23T22:16:57.059000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Wi-Fi Blood Pressure Monitor",
        "trust": 0.8,
        "url": "http://www.blipcare.com/blip-bp.html"
      },
      {
        "title": "Blipcare Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=94345"
      },
      {
        "title": "IoT_vulnerabilities",
        "trust": 0.1,
        "url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-254",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/blipcare_sec_issues.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://seclists.org/bugtraq/2019/jun/8"
      },
      {
        "trust": 1.8,
        "url": "http://packetstormsecurity.com/files/153225/blipcare-clear-text-communication-memory-corruption.html"
      },
      {
        "trust": 1.5,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11579"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11579"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/254.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/ethanhunnt/iot_vulnerabilities"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11580"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11578"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "date": "2019-07-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "date": "2019-06-07T15:06:02",
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "date": "2017-07-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      },
      {
        "date": "2019-07-02T21:15:09.930000",
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-15T00:00:00",
        "db": "VULHUB",
        "id": "VHN-102015"
      },
      {
        "date": "2019-07-15T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-11579"
      },
      {
        "date": "2019-07-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      },
      {
        "date": "2019-07-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      },
      {
        "date": "2024-11-21T03:08:04.190000",
        "db": "NVD",
        "id": "CVE-2017-11579"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Blipcare Wireless Blood pressure monitor Vulnerabilities related to security functions",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014574"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "security feature problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1027"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…