VAR-201907-1043

Vulnerability from variot - Updated: 2025-01-30 19:39

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack. There is a security flaw in the Blipcare device

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1043",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wi-fi blood pressure monitor",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "blipcare",
        "version": "bp700_10.1"
      },
      {
        "model": "wifi blood pressure monitor",
        "scope": null,
        "trust": 0.8,
        "vendor": "blipcare",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:blipcare:wi-fi_blood_pressure_monitor_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mandar Satam",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "153225"
      }
    ],
    "trust": 0.1
  },
  "cve": "CVE-2017-11578",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2017-11578",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-102014",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.2,
            "id": "CVE-2017-11578",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-11578",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-11578",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201707-1028",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-102014",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-11578",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack. There is a security flaw in the Blipcare device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11578"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-11578",
        "trust": 2.8
      },
      {
        "db": "PACKETSTORM",
        "id": "153225",
        "trust": 1.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028",
        "trust": 0.7
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-102014",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11578",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "id": "VAR-201907-1043",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      }
    ],
    "trust": 0.02
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "medical device"
        ],
        "sub_category": "blood pressure monitor",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ]
  },
  "last_update_date": "2025-01-30T19:39:08.336000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Wi-Fi Blood Pressure Monitor",
        "trust": 0.8,
        "url": "http://www.blipcare.com/blip-bp.html"
      },
      {
        "title": "Blipcare Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=94346"
      },
      {
        "title": "IoT_vulnerabilities",
        "trust": 0.1,
        "url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/blipcare_sec_issues.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://seclists.org/bugtraq/2019/jun/8"
      },
      {
        "trust": 1.8,
        "url": "http://packetstormsecurity.com/files/153225/blipcare-clear-text-communication-memory-corruption.html"
      },
      {
        "trust": 1.5,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11578"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11578"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/200.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/ethanhunnt/iot_vulnerabilities"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11580"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-11579"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "date": "2019-07-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "date": "2019-06-07T15:06:02",
        "db": "PACKETSTORM",
        "id": "153225"
      },
      {
        "date": "2017-07-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      },
      {
        "date": "2019-07-02T21:15:09.870000",
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-15T00:00:00",
        "db": "VULHUB",
        "id": "VHN-102014"
      },
      {
        "date": "2019-07-15T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-11578"
      },
      {
        "date": "2019-07-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      },
      {
        "date": "2019-07-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      },
      {
        "date": "2024-11-21T03:08:04.020000",
        "db": "NVD",
        "id": "CVE-2017-11578"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Blipcare Wireless Blood pressure monitor Vulnerable to information disclosure",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014575"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "information disclosure",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201707-1028"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…