VAR-201907-1043
Vulnerability from variot - Updated: 2025-01-30 19:39It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack. There is a security flaw in the Blipcare device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-1043",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wi-fi blood pressure monitor",
"scope": "lte",
"trust": 1.0,
"vendor": "blipcare",
"version": "bp700_10.1"
},
{
"model": "wifi blood pressure monitor",
"scope": null,
"trust": 0.8,
"vendor": "blipcare",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:blipcare:wi-fi_blood_pressure_monitor_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mandar Satam",
"sources": [
{
"db": "PACKETSTORM",
"id": "153225"
}
],
"trust": 0.1
},
"cve": "CVE-2017-11578",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2017-11578",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-102014",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"id": "CVE-2017-11578",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-11578",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2017-11578",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201707-1028",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-102014",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2017-11578",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-102014"
},
{
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
},
{
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack. There is a security flaw in the Blipcare device",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-11578"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "VULHUB",
"id": "VHN-102014"
},
{
"db": "VULMON",
"id": "CVE-2017-11578"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-11578",
"trust": 2.8
},
{
"db": "PACKETSTORM",
"id": "153225",
"trust": 1.9
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201707-1028",
"trust": 0.7
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-102014",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2017-11578",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-102014"
},
{
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "PACKETSTORM",
"id": "153225"
},
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
},
{
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"id": "VAR-201907-1043",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-102014"
}
],
"trust": 0.02
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"medical device"
],
"sub_category": "blood pressure monitor",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-01-30T19:39:08.336000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Wi-Fi Blood Pressure Monitor",
"trust": 0.8,
"url": "http://www.blipcare.com/blip-bp.html"
},
{
"title": "Blipcare Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=94346"
},
{
"title": "IoT_vulnerabilities",
"trust": 0.1,
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-102014"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://github.com/ethanhunnt/iot_vulnerabilities/blob/master/blipcare_sec_issues.pdf"
},
{
"trust": 1.8,
"url": "https://seclists.org/bugtraq/2019/jun/8"
},
{
"trust": 1.8,
"url": "http://packetstormsecurity.com/files/153225/blipcare-clear-text-communication-memory-corruption.html"
},
{
"trust": 1.5,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-11578"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-11578"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/ethanhunnt/iot_vulnerabilities"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-11580"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-11579"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-102014"
},
{
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "PACKETSTORM",
"id": "153225"
},
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
},
{
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-102014"
},
{
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"db": "PACKETSTORM",
"id": "153225"
},
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
},
{
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-02T00:00:00",
"db": "VULHUB",
"id": "VHN-102014"
},
{
"date": "2019-07-02T00:00:00",
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"date": "2019-07-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"date": "2019-06-07T15:06:02",
"db": "PACKETSTORM",
"id": "153225"
},
{
"date": "2017-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201707-1028"
},
{
"date": "2019-07-02T21:15:09.870000",
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-15T00:00:00",
"db": "VULHUB",
"id": "VHN-102014"
},
{
"date": "2019-07-15T00:00:00",
"db": "VULMON",
"id": "CVE-2017-11578"
},
{
"date": "2019-07-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014575"
},
{
"date": "2019-07-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201707-1028"
},
{
"date": "2024-11-21T03:08:04.020000",
"db": "NVD",
"id": "CVE-2017-11578"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Blipcare Wireless Blood pressure monitor Vulnerable to information disclosure",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014575"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201707-1028"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…