Search

Find a vulnerability

Search criteria

    18 vulnerabilities found for xmm_7560_firmware by intel

    CVE-2022-28611 (GCVE-0-2022-28611)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:56:16.121Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-28611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:41:21.736125Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-20",
                    "description": "CWE-20 Improper Input Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:35.045Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:11.652Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-28611",
        "datePublished": "2022-11-11T15:48:45.794Z",
        "dateReserved": "2022-04-05T15:11:54.332Z",
        "dateUpdated": "2025-02-05T20:47:35.045Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-28126 (GCVE-0-2022-28126)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:48:37.883Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-28126",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:37.937111Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-20",
                    "description": "CWE-20 Improper Input Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:19.981Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:13.002Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-28126",
        "datePublished": "2022-11-11T15:48:46.764Z",
        "dateReserved": "2022-04-05T15:11:54.313Z",
        "dateUpdated": "2025-02-05T20:47:19.981Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27874 (GCVE-0-2022-27874)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:41:10.193Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-27874",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:41:24.602048Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-287",
                    "description": "CWE-287 Improper Authentication",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:44.677Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:10.955Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-27874",
        "datePublished": "2022-11-11T15:48:45.296Z",
        "dateReserved": "2022-04-05T15:11:54.317Z",
        "dateUpdated": "2025-02-05T20:47:44.677Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27639 (GCVE-0-2022-27639)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
    VLAI
    Summary
    Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-459 - Incomplete Cleanup
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.797Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-27639",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:29.532787Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-459",
                    "description": "CWE-459 Incomplete Cleanup",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:46:47.989Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:15.117Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-27639",
        "datePublished": "2022-11-11T15:48:48.279Z",
        "dateReserved": "2022-04-05T15:11:54.304Z",
        "dateUpdated": "2025-02-05T20:46:47.989Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26513 (GCVE-0-2022-26513)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-787 - Out-of-bounds Write
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.978Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26513",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:43.642576Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:56.987Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:10.272Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26513",
        "datePublished": "2022-11-11T15:48:44.749Z",
        "dateReserved": "2022-04-05T15:11:54.328Z",
        "dateUpdated": "2025-02-05T20:47:56.987Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26369 (GCVE-0-2022-26369)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-125 - Out-of-bounds Read
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.842Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26369",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:40.719783Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-125",
                    "description": "CWE-125 Out-of-bounds Read",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:27.877Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:12.335Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26369",
        "datePublished": "2022-11-11T15:48:46.271Z",
        "dateReserved": "2022-04-05T15:11:17.500Z",
        "dateUpdated": "2025-02-05T20:47:27.877Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26367 (GCVE-0-2022-26367)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.805Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:35.041407Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-119",
                    "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:12.300Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:13.685Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26367",
        "datePublished": "2022-11-11T15:48:47.217Z",
        "dateReserved": "2022-04-05T15:11:54.299Z",
        "dateUpdated": "2025-02-05T20:47:12.300Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26079 (GCVE-0-2022-26079)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
    VLAI
    Summary
    Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:37.787Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:32.347515Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-754",
                    "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:46:57.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:14.407Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26079",
        "datePublished": "2022-11-11T15:48:47.785Z",
        "dateReserved": "2022-04-05T15:11:54.308Z",
        "dateUpdated": "2025-02-05T20:46:57.179Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26045 (GCVE-0-2022-26045)

    Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
    VLAI
    Summary
    Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:37.421Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26045",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:26.674792Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-119",
                    "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:46:38.739Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:15.785Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26045",
        "datePublished": "2022-11-11T15:48:48.801Z",
        "dateReserved": "2022-04-05T15:11:54.322Z",
        "dateUpdated": "2025-02-05T20:46:38.739Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26045 (GCVE-0-2022-26045)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
    VLAI
    Summary
    Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:37.421Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26045",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:26.674792Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-119",
                    "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:46:38.739Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:15.785Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26045",
        "datePublished": "2022-11-11T15:48:48.801Z",
        "dateReserved": "2022-04-05T15:11:54.322Z",
        "dateUpdated": "2025-02-05T20:46:38.739Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27639 (GCVE-0-2022-27639)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
    VLAI
    Summary
    Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-459 - Incomplete Cleanup
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:32:59.797Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-27639",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:29.532787Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-459",
                    "description": "CWE-459 Incomplete Cleanup",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:46:47.989Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:15.117Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-27639",
        "datePublished": "2022-11-11T15:48:48.279Z",
        "dateReserved": "2022-04-05T15:11:54.304Z",
        "dateUpdated": "2025-02-05T20:46:47.989Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26079 (GCVE-0-2022-26079)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
    VLAI
    Summary
    Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:37.787Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:32.347515Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-754",
                    "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:46:57.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:14.407Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26079",
        "datePublished": "2022-11-11T15:48:47.785Z",
        "dateReserved": "2022-04-05T15:11:54.308Z",
        "dateUpdated": "2025-02-05T20:46:57.179Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26367 (GCVE-0-2022-26367)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.805Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:35.041407Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-119",
                    "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:12.300Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:13.685Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26367",
        "datePublished": "2022-11-11T15:48:47.217Z",
        "dateReserved": "2022-04-05T15:11:54.299Z",
        "dateUpdated": "2025-02-05T20:47:12.300Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-28126 (GCVE-0-2022-28126)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:48:37.883Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-28126",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:37.937111Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-20",
                    "description": "CWE-20 Improper Input Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:19.981Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:13.002Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-28126",
        "datePublished": "2022-11-11T15:48:46.764Z",
        "dateReserved": "2022-04-05T15:11:54.313Z",
        "dateUpdated": "2025-02-05T20:47:19.981Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26369 (GCVE-0-2022-26369)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-125 - Out-of-bounds Read
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.842Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26369",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:40.719783Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-125",
                    "description": "CWE-125 Out-of-bounds Read",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:27.877Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:12.335Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26369",
        "datePublished": "2022-11-11T15:48:46.271Z",
        "dateReserved": "2022-04-05T15:11:17.500Z",
        "dateUpdated": "2025-02-05T20:47:27.877Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-28611 (GCVE-0-2022-28611)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:56:16.121Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-28611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:41:21.736125Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-20",
                    "description": "CWE-20 Improper Input Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:35.045Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:11.652Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-28611",
        "datePublished": "2022-11-11T15:48:45.794Z",
        "dateReserved": "2022-04-05T15:11:54.332Z",
        "dateUpdated": "2025-02-05T20:47:35.045Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-27874 (GCVE-0-2022-27874)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:41:10.193Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-27874",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:41:24.602048Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-287",
                    "description": "CWE-287 Improper Authentication",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:44.677Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:10.955Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-27874",
        "datePublished": "2022-11-11T15:48:45.296Z",
        "dateReserved": "2022-04-05T15:11:54.317Z",
        "dateUpdated": "2025-02-05T20:47:44.677Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26513 (GCVE-0-2022-26513)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
    VLAI
    Summary
    Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • escalation of privilege
    • CWE-787 - Out-of-bounds Write
    Assigner
    Impacted products
    Vendor Product Version
    n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.978Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26513",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:43.642576Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:47:56.987Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:10.272Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26513",
        "datePublished": "2022-11-11T15:48:44.749Z",
        "dateReserved": "2022-04-05T15:11:54.328Z",
        "dateUpdated": "2025-02-05T20:47:56.987Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }