Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

18 vulnerabilities found for xmm_7560_firmware by intel

CVE-2022-28611 (GCVE-0-2022-28611)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:56:16.121Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28611",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:41:21.736125Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:35.045Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:11.652Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-28611",
    "datePublished": "2022-11-11T15:48:45.794Z",
    "dateReserved": "2022-04-05T15:11:54.332Z",
    "dateUpdated": "2025-02-05T20:47:35.045Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28126 (GCVE-0-2022-28126)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:48:37.883Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28126",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:37.937111Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:19.981Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:13.002Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-28126",
    "datePublished": "2022-11-11T15:48:46.764Z",
    "dateReserved": "2022-04-05T15:11:54.313Z",
    "dateUpdated": "2025-02-05T20:47:19.981Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27874 (GCVE-0-2022-27874)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:41:10.193Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-27874",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:41:24.602048Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:44.677Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:10.955Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-27874",
    "datePublished": "2022-11-11T15:48:45.296Z",
    "dateReserved": "2022-04-05T15:11:54.317Z",
    "dateUpdated": "2025-02-05T20:47:44.677Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27639 (GCVE-0-2022-27639)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:32:59.797Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-27639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:29.532787Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-459",
                "description": "CWE-459 Incomplete Cleanup",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:47.989Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:15.117Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-27639",
    "datePublished": "2022-11-11T15:48:48.279Z",
    "dateReserved": "2022-04-05T15:11:54.304Z",
    "dateUpdated": "2025-02-05T20:46:47.989Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26513 (GCVE-0-2022-26513)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.978Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26513",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:43.642576Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:56.987Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:10.272Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26513",
    "datePublished": "2022-11-11T15:48:44.749Z",
    "dateReserved": "2022-04-05T15:11:54.328Z",
    "dateUpdated": "2025-02-05T20:47:56.987Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26369 (GCVE-0-2022-26369)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26369",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:40.719783Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-125",
                "description": "CWE-125 Out-of-bounds Read",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:27.877Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:12.335Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26369",
    "datePublished": "2022-11-11T15:48:46.271Z",
    "dateReserved": "2022-04-05T15:11:17.500Z",
    "dateUpdated": "2025-02-05T20:47:27.877Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26367 (GCVE-0-2022-26367)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.805Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26367",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:35.041407Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-119",
                "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:12.300Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:13.685Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26367",
    "datePublished": "2022-11-11T15:48:47.217Z",
    "dateReserved": "2022-04-05T15:11:54.299Z",
    "dateUpdated": "2025-02-05T20:47:12.300Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26079 (GCVE-0-2022-26079)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.787Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26079",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:32.347515Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-754",
                "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:57.179Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:14.407Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26079",
    "datePublished": "2022-11-11T15:48:47.785Z",
    "dateReserved": "2022-04-05T15:11:54.308Z",
    "dateUpdated": "2025-02-05T20:46:57.179Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26045 (GCVE-0-2022-26045)

Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26045",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:26.674792Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-119",
                "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:38.739Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:15.785Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26045",
    "datePublished": "2022-11-11T15:48:48.801Z",
    "dateReserved": "2022-04-05T15:11:54.322Z",
    "dateUpdated": "2025-02-05T20:46:38.739Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26045 (GCVE-0-2022-26045)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26045",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:26.674792Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-119",
                "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:38.739Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:15.785Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26045",
    "datePublished": "2022-11-11T15:48:48.801Z",
    "dateReserved": "2022-04-05T15:11:54.322Z",
    "dateUpdated": "2025-02-05T20:46:38.739Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27639 (GCVE-0-2022-27639)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:32:59.797Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-27639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:29.532787Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-459",
                "description": "CWE-459 Incomplete Cleanup",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:47.989Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:15.117Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-27639",
    "datePublished": "2022-11-11T15:48:48.279Z",
    "dateReserved": "2022-04-05T15:11:54.304Z",
    "dateUpdated": "2025-02-05T20:46:47.989Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26079 (GCVE-0-2022-26079)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.787Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26079",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:32.347515Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-754",
                "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:57.179Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:14.407Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26079",
    "datePublished": "2022-11-11T15:48:47.785Z",
    "dateReserved": "2022-04-05T15:11:54.308Z",
    "dateUpdated": "2025-02-05T20:46:57.179Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26367 (GCVE-0-2022-26367)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.805Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26367",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:35.041407Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-119",
                "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:12.300Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:13.685Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26367",
    "datePublished": "2022-11-11T15:48:47.217Z",
    "dateReserved": "2022-04-05T15:11:54.299Z",
    "dateUpdated": "2025-02-05T20:47:12.300Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28126 (GCVE-0-2022-28126)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:48:37.883Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28126",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:37.937111Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:19.981Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:13.002Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-28126",
    "datePublished": "2022-11-11T15:48:46.764Z",
    "dateReserved": "2022-04-05T15:11:54.313Z",
    "dateUpdated": "2025-02-05T20:47:19.981Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26369 (GCVE-0-2022-26369)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26369",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:40.719783Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-125",
                "description": "CWE-125 Out-of-bounds Read",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:27.877Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:12.335Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26369",
    "datePublished": "2022-11-11T15:48:46.271Z",
    "dateReserved": "2022-04-05T15:11:17.500Z",
    "dateUpdated": "2025-02-05T20:47:27.877Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28611 (GCVE-0-2022-28611)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:56:16.121Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28611",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:41:21.736125Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:35.045Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:11.652Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-28611",
    "datePublished": "2022-11-11T15:48:45.794Z",
    "dateReserved": "2022-04-05T15:11:54.332Z",
    "dateUpdated": "2025-02-05T20:47:35.045Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27874 (GCVE-0-2022-27874)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:41:10.193Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-27874",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:41:24.602048Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:44.677Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:10.955Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-27874",
    "datePublished": "2022-11-11T15:48:45.296Z",
    "dateReserved": "2022-04-05T15:11:54.317Z",
    "dateUpdated": "2025-02-05T20:47:44.677Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26513 (GCVE-0-2022-26513)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
CWE
  • escalation of privilege
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.978Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26513",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:43.642576Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:47:56.987Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:10.272Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26513",
    "datePublished": "2022-11-11T15:48:44.749Z",
    "dateReserved": "2022-04-05T15:11:54.328Z",
    "dateUpdated": "2025-02-05T20:47:56.987Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}