CVE-2022-28611 (GCVE-0-2022-28611)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
Severity ?
6.8 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:56:16.121Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-28611",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:41:21.736125Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:35.045Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:11.652Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-28611",
"datePublished": "2022-11-11T15:48:45.794Z",
"dateReserved": "2022-04-05T15:11:54.332Z",
"dateUpdated": "2025-02-05T20:47:35.045Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28126 (GCVE-0-2022-28126)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
6 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.883Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-28126",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:37.937111Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:19.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:13.002Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-28126",
"datePublished": "2022-11-11T15:48:46.764Z",
"dateReserved": "2022-04-05T15:11:54.313Z",
"dateUpdated": "2025-02-05T20:47:19.981Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27874 (GCVE-0-2022-27874)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
Severity ?
6.8 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:41:10.193Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27874",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:41:24.602048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:44.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:10.955Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-27874",
"datePublished": "2022-11-11T15:48:45.296Z",
"dateReserved": "2022-04-05T15:11:54.317Z",
"dateUpdated": "2025-02-05T20:47:44.677Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27639 (GCVE-0-2022-27639)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
Severity ?
5.4 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.797Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:29.532787Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-459",
"description": "CWE-459 Incomplete Cleanup",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:46:47.989Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:15.117Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-27639",
"datePublished": "2022-11-11T15:48:48.279Z",
"dateReserved": "2022-04-05T15:11:54.304Z",
"dateUpdated": "2025-02-05T20:46:47.989Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26513 (GCVE-0-2022-26513)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
Severity ?
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:03:32.978Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26513",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:43.642576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:56.987Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:10.272Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26513",
"datePublished": "2022-11-11T15:48:44.749Z",
"dateReserved": "2022-04-05T15:11:54.328Z",
"dateUpdated": "2025-02-05T20:47:56.987Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26369 (GCVE-0-2022-26369)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
Severity ?
6.2 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:03:32.842Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26369",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:40.719783Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:27.877Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:12.335Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26369",
"datePublished": "2022-11-11T15:48:46.271Z",
"dateReserved": "2022-04-05T15:11:17.500Z",
"dateUpdated": "2025-02-05T20:47:27.877Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26367 (GCVE-0-2022-26367)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
6 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:03:32.805Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:35.041407Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:12.300Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:13.685Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26367",
"datePublished": "2022-11-11T15:48:47.217Z",
"dateReserved": "2022-04-05T15:11:54.299Z",
"dateUpdated": "2025-02-05T20:47:12.300Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26079 (GCVE-0-2022-26079)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
6 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:37.787Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26079",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:32.347515Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:46:57.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:14.407Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26079",
"datePublished": "2022-11-11T15:48:47.785Z",
"dateReserved": "2022-04-05T15:11:54.308Z",
"dateUpdated": "2025-02-05T20:46:57.179Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26045 (GCVE-0-2022-26045)
Vulnerability from nvd – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
Severity ?
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:37.421Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26045",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:26.674792Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:46:38.739Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:15.785Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26045",
"datePublished": "2022-11-11T15:48:48.801Z",
"dateReserved": "2022-04-05T15:11:54.322Z",
"dateUpdated": "2025-02-05T20:46:38.739Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26045 (GCVE-0-2022-26045)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
Severity ?
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:37.421Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26045",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:26.674792Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:46:38.739Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:15.785Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26045",
"datePublished": "2022-11-11T15:48:48.801Z",
"dateReserved": "2022-04-05T15:11:54.322Z",
"dateUpdated": "2025-02-05T20:46:38.739Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27639 (GCVE-0-2022-27639)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
Severity ?
5.4 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.797Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:29.532787Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-459",
"description": "CWE-459 Incomplete Cleanup",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:46:47.989Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:15.117Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-27639",
"datePublished": "2022-11-11T15:48:48.279Z",
"dateReserved": "2022-04-05T15:11:54.304Z",
"dateUpdated": "2025-02-05T20:46:47.989Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26079 (GCVE-0-2022-26079)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI?
Summary
Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
6 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:37.787Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26079",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:32.347515Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:46:57.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:14.407Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26079",
"datePublished": "2022-11-11T15:48:47.785Z",
"dateReserved": "2022-04-05T15:11:54.308Z",
"dateUpdated": "2025-02-05T20:46:57.179Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26367 (GCVE-0-2022-26367)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
6 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:03:32.805Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:35.041407Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:12.300Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:13.685Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26367",
"datePublished": "2022-11-11T15:48:47.217Z",
"dateReserved": "2022-04-05T15:11:54.299Z",
"dateUpdated": "2025-02-05T20:47:12.300Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28126 (GCVE-0-2022-28126)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
Severity ?
6 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.883Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-28126",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:37.937111Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:19.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:13.002Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-28126",
"datePublished": "2022-11-11T15:48:46.764Z",
"dateReserved": "2022-04-05T15:11:54.313Z",
"dateUpdated": "2025-02-05T20:47:19.981Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26369 (GCVE-0-2022-26369)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access.
Severity ?
6.2 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:03:32.842Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26369",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:40.719783Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:27.877Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds read in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:12.335Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26369",
"datePublished": "2022-11-11T15:48:46.271Z",
"dateReserved": "2022-04-05T15:11:17.500Z",
"dateUpdated": "2025-02-05T20:47:27.877Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28611 (GCVE-0-2022-28611)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
Severity ?
6.8 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:56:16.121Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-28611",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:41:21.736125Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:35.045Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper input validation in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:11.652Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-28611",
"datePublished": "2022-11-11T15:48:45.794Z",
"dateReserved": "2022-04-05T15:11:54.332Z",
"dateUpdated": "2025-02-05T20:47:35.045Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27874 (GCVE-0-2022-27874)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
Severity ?
6.8 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:41:10.193Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-27874",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:41:24.602048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:44.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper authentication in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:10.955Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-27874",
"datePublished": "2022-11-11T15:48:45.296Z",
"dateReserved": "2022-04-05T15:11:54.317Z",
"dateUpdated": "2025-02-05T20:47:44.677Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26513 (GCVE-0-2022-26513)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:47
VLAI?
Summary
Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
Severity ?
CWE
- escalation of privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) XMM(TM) 7560 Modem software |
Affected:
before version M2_7560_R_01.2146.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:03:32.978Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26513",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:43.642576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:47:56.987Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) XMM(TM) 7560 Modem software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version M2_7560_R_01.2146.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds write in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:10.272Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-26513",
"datePublished": "2022-11-11T15:48:44.749Z",
"dateReserved": "2022-04-05T15:11:54.328Z",
"dateUpdated": "2025-02-05T20:47:56.987Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}