CVE-2022-43768 (GCVE-0-2022-43768)
Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2025-02-07 16:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43768",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:50:58.868618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:51:07.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:34.861Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43768",
"datePublished": "2023-04-11T09:02:51.623Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2025-02-07T16:51:07.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43767 (GCVE-0-2022-43767)
Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-833 - Deadlock
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43767",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-12T19:11:06.737320Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-12T20:11:32.129Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:33.351Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43767",
"datePublished": "2023-04-11T09:02:50.497Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2024-09-10T09:33:33.351Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43716 (GCVE-0-2022-43716)
Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_gprs_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43716",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T14:12:55.560896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T14:35:43.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:31.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43716",
"datePublished": "2023-04-11T09:02:49.383Z",
"dateReserved": "2022-10-24T05:19:12.272Z",
"dateUpdated": "2024-09-10T09:33:31.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44695 (GCVE-0-2021-44695)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-1286 - Improper Validation of Syntactic Correctness of Input
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.962Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-44695",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:10.642001Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:22.632Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1286",
"description": "CWE-1286: Improper Validation of Syntactic Correctness of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:56.466Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44695",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-12-07T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:22.632Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44694 (GCVE-0-2021-44694)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-1287 - Improper Validation of Specified Type of Input
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.926Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-44694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:14.254940Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:31.195Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1287",
"description": "CWE-1287: Improper Validation of Specified Type of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:54.785Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44694",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-12-07T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:31.195Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44693 (GCVE-0-2021-44693)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.966Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-44693",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:17.856761Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:41.428Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284: Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:53.197Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44693",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-12-07T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:41.428Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40365 (GCVE-0-2021-40365)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-40365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:11.646488Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:50.798Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:51.565Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40365",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:50.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37205 (GCVE-0-2021-37205)
Vulnerability from nvd – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:29
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Severity ?
CWE
- CWE-401 - Missing Release of Memory after Effective Lifetime
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions >= V2.9.2 < V2.9.4
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.897Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37205",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:33.320440Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T18:29:47.038Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-401",
"description": "CWE-401: Missing Release of Memory after Effective Lifetime",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:55.468Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37205",
"datePublished": "2022-02-09T15:16:57.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-04-18T18:29:47.038Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37204 (GCVE-0-2021-37204)
Vulnerability from nvd – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Severity ?
CWE
- CWE-672 - Operation on a Resource after Expiration or Release
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions < V2.9.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.812Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37204",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:37.070496Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T18:33:01.575Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-672",
"description": "CWE-672: Operation on a Resource after Expiration or Release",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:54.435Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37204",
"datePublished": "2022-02-09T15:16:56.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-04-18T18:33:01.575Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37185 (GCVE-0-2021-37185)
Vulnerability from nvd – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Severity ?
CWE
- CWE-672 - Operation on a Resource after Expiration or Release
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions >= V2.9.2 < V2.9.4
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.183Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37185",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:41.029825Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T18:33:19.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-672",
"description": "CWE-672: Operation on a Resource after Expiration or Release",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:53.394Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37185",
"datePublished": "2022-02-09T15:16:44.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-04-18T18:33:19.110Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-28397 (GCVE-0-2020-28397)
Vulnerability from nvd – Published: 2021-08-10 10:35 – Updated: 2024-08-04 16:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
Severity ?
No CVSS data available.
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions < V2.9.2
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:59.119Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"product": "SIMATIC S7 PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e V2 \u003c V4"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "Version V4.4"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e V2.5 \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e V2.5 \u003c V21.9"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "Version V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:15",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-28397",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Drive Controller family",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V21.9"
}
]
}
},
{
"product_name": "SIMATIC S7 PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003e V2 \u003c V4"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "Version V4.4"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003e V2.5 \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003e V2.5 \u003c V21.9"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "Version V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-863: Incorrect Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-28397",
"datePublished": "2021-08-10T10:35:23",
"dateReserved": "2020-11-10T00:00:00",
"dateUpdated": "2024-08-04T16:33:59.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3449 (GCVE-0-2021-3449)
Vulnerability from nvd – Published: 2021-03-25 14:25 – Updated: 2024-09-17 03:43
VLAI?
Title
NULL pointer deref in signature_algorithms processing
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
Severity ?
No CVSS data available.
CWE
- NULL pointer dereference
Assigner
References
| URL | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Impacted products
Credits
Peter Kästle (Nokia) and Samuel Sapalski (Nokia)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T16:53:17.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.openssl.org/news/secadv/20210325.txt"
},
{
"tags": [
"x_transferred"
],
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
},
{
"name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
},
{
"name": "DSA-4875",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2021/dsa-4875"
},
{
"name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
},
{
"name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
},
{
"name": "GLSA-202103-03",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202103-03"
},
{
"name": "FEDORA-2021-cbf14ab8f9",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-10"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-09"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-06"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-05"
},
{
"tags": [
"x_transferred"
],
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com//security-alerts/cpujul2021.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
},
{
"name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpujul2022.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenSSL",
"vendor": "OpenSSL",
"versions": [
{
"status": "affected",
"version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
}
],
"datePublic": "2021-03-25T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
}
],
"metrics": [
{
"other": {
"content": {
"lang": "eng",
"url": "https://www.openssl.org/policies/secpolicy.html#High",
"value": "High"
},
"type": "unknown"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NULL pointer dereference",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-21T19:05:57.096577",
"orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"shortName": "openssl"
},
"references": [
{
"url": "https://www.openssl.org/news/secadv/20210325.txt"
},
{
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
},
{
"name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
},
{
"name": "DSA-4875",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2021/dsa-4875"
},
{
"name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
},
{
"name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
},
{
"name": "GLSA-202103-03",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202103-03"
},
{
"name": "FEDORA-2021-cbf14ab8f9",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
},
{
"url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
},
{
"url": "https://www.tenable.com/security/tns-2021-10"
},
{
"url": "https://www.tenable.com/security/tns-2021-09"
},
{
"url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
},
{
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
},
{
"url": "https://www.tenable.com/security/tns-2021-06"
},
{
"url": "https://www.tenable.com/security/tns-2021-05"
},
{
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
},
{
"url": "https://www.oracle.com//security-alerts/cpujul2021.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
},
{
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
},
{
"name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
},
{
"url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
},
{
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"url": "https://www.oracle.com/security-alerts/cpujul2022.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
}
],
"title": "NULL pointer deref in signature_algorithms processing"
}
},
"cveMetadata": {
"assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"assignerShortName": "openssl",
"cveId": "CVE-2021-3449",
"datePublished": "2021-03-25T14:25:13.659307Z",
"dateReserved": "2021-03-17T00:00:00",
"dateUpdated": "2024-09-17T03:43:55.497Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27827 (GCVE-0-2020-27827)
Vulnerability from nvd – Published: 2021-03-18 00:00 – Updated: 2025-12-03 18:20
VLAI?
Summary
A flaw was found in multiple versions of OpenvSwitch. Specially crafted LLDP packets can cause memory to be lost when allocating data to handle specific optional TLVs, potentially causing a denial of service. The highest threat from this vulnerability is to system availability.
Severity ?
7.5 (High)
CWE
Assigner
References
| URL | Tags | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | lldp/openvswitch |
Affected:
lldpd 1.0.8, openvswitch 2.14.1, openvswitch 2.13.2, openvswitch 2.12.2, openvswitch 2.11.5, openvswitch 2.10.6, openvswitch 2.9.8, openvswitch 2.8.10, openvswitch 2.7.12, openvswitch 2.6.9
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:25:43.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1921438"
},
{
"tags": [
"x_transferred"
],
"url": "https://mail.openvswitch.org/pipermail/ovs-dev/2021-January/379471.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-941426.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-07"
},
{
"name": "FEDORA-2023-88991d2713",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JYA4AMJXCNF6UPFG36L2TPPT32C242SP/"
},
{
"name": "FEDORA-2023-c0c184a019",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3T5XHPOGIPWCRRPJUE6P3HVC5PTSD5JS/"
},
{
"name": "FEDORA-2023-3e4feeadec",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SKQWHG2SZJZSGC7PXVDAEJYBN7ESDR7D/"
},
{
"name": "GLSA-202311-16",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202311-16"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-27827",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-04T13:38:48.935265Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-03T18:20:03.875Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "lldp/openvswitch",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "lldpd 1.0.8, openvswitch 2.14.1, openvswitch 2.13.2, openvswitch 2.12.2, openvswitch 2.11.5, openvswitch 2.10.6, openvswitch 2.9.8, openvswitch 2.8.10, openvswitch 2.7.12, openvswitch 2.6.9"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in multiple versions of OpenvSwitch. Specially crafted LLDP packets can cause memory to be lost when allocating data to handle specific optional TLVs, potentially causing a denial of service. The highest threat from this vulnerability is to system availability."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-26T11:06:15.202Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1921438"
},
{
"url": "https://mail.openvswitch.org/pipermail/ovs-dev/2021-January/379471.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-941426.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-07"
},
{
"name": "FEDORA-2023-88991d2713",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JYA4AMJXCNF6UPFG36L2TPPT32C242SP/"
},
{
"name": "FEDORA-2023-c0c184a019",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3T5XHPOGIPWCRRPJUE6P3HVC5PTSD5JS/"
},
{
"name": "FEDORA-2023-3e4feeadec",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SKQWHG2SZJZSGC7PXVDAEJYBN7ESDR7D/"
},
{
"name": "GLSA-202311-16",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202311-16"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2020-27827",
"datePublished": "2021-03-18T00:00:00.000Z",
"dateReserved": "2020-10-27T00:00:00.000Z",
"dateUpdated": "2025-12-03T18:20:03.875Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6568 (GCVE-0-2019-6568)
Vulnerability from nvd – Published: 2019-04-17 13:40 – Updated: 2024-08-04 20:23
VLAI?
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1604 |
Affected:
All versions
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC DiagMonitor",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF182C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF185C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF186C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF188C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF600R family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RFID 181EIP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0 SP1 UPD1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.6 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V5.1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V5.1 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.6 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V5.1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V5.1 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.6 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V5.1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V5.1 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S210",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF33"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF10"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 343-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP Manager",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-09T11:51:03.049Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6568",
"datePublished": "2019-04-17T13:40:24",
"dateReserved": "2019-01-22T00:00:00",
"dateUpdated": "2024-08-04T20:23:22.207Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-13816 (GCVE-0-2018-13816)
Vulnerability from nvd – Published: 2018-12-12 16:00 – Updated: 2024-08-05 09:14
VLAI?
Summary
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | TIM 1531 IRC |
Affected:
TIM 1531 IRC : All version < V2.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:14:47.170Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
},
{
"name": "106194",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106194"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "TIM 1531 IRC",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "TIM 1531 IRC : All version \u003c V2.0"
}
]
}
],
"datePublic": "2018-12-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in TIM 1531 IRC (All version \u003c V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-14T10:57:02",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
},
{
"name": "106194",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106194"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-13816",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "TIM 1531 IRC",
"version": {
"version_data": [
{
"version_value": "TIM 1531 IRC : All version \u003c V2.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in TIM 1531 IRC (All version \u003c V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
},
{
"name": "106194",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106194"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-13816",
"datePublished": "2018-12-12T16:00:00",
"dateReserved": "2018-07-10T00:00:00",
"dateUpdated": "2024-08-05T09:14:47.170Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43768 (GCVE-0-2022-43768)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2025-02-07 16:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43768",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:50:58.868618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:51:07.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:34.861Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43768",
"datePublished": "2023-04-11T09:02:51.623Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2025-02-07T16:51:07.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43767 (GCVE-0-2022-43767)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-833 - Deadlock
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43767",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-12T19:11:06.737320Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-12T20:11:32.129Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:33.351Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43767",
"datePublished": "2023-04-11T09:02:50.497Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2024-09-10T09:33:33.351Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43716 (GCVE-0-2022-43716)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_gprs_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43716",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T14:12:55.560896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T14:35:43.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:31.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43716",
"datePublished": "2023-04-11T09:02:49.383Z",
"dateReserved": "2022-10-24T05:19:12.272Z",
"dateUpdated": "2024-09-10T09:33:31.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44694 (GCVE-0-2021-44694)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-1287 - Improper Validation of Specified Type of Input
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.926Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-44694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:14.254940Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:31.195Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1287",
"description": "CWE-1287: Improper Validation of Specified Type of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:54.785Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44694",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-12-07T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:31.195Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44693 (GCVE-0-2021-44693)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.966Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-44693",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:17.856761Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:41.428Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284: Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:53.197Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44693",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-12-07T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:41.428Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40365 (GCVE-0-2021-40365)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:09.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-40365",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:11.646488Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:50.798Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:51.565Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-40365",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-09-01T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:50.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44695 (GCVE-0-2021-44695)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:45
VLAI?
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Severity ?
CWE
- CWE-1286 - Improper Validation of Syntactic Correctness of Input
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller CPU 1504D TF |
Affected:
All versions < V2.9.7
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:25:16.962Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-44695",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:10.642001Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:45:22.632Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1504D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller CPU 1507D TF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511T-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512C-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1513R-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515T-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1511F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1513F-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1517H-3 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1286",
"description": "CWE-1286: Improper Validation of Syntactic Correctness of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:31:56.466Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-44695",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2021-12-07T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:45:22.632Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37205 (GCVE-0-2021-37205)
Vulnerability from cvelistv5 – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:29
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Severity ?
CWE
- CWE-401 - Missing Release of Memory after Effective Lifetime
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions >= V2.9.2 < V2.9.4
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.897Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37205",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:33.320440Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T18:29:47.038Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-401",
"description": "CWE-401: Missing Release of Memory after Effective Lifetime",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:55.468Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37205",
"datePublished": "2022-02-09T15:16:57.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-04-18T18:29:47.038Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37204 (GCVE-0-2021-37204)
Vulnerability from cvelistv5 – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Severity ?
CWE
- CWE-672 - Operation on a Resource after Expiration or Release
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions < V2.9.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.812Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37204",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:37.070496Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T18:33:01.575Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-672",
"description": "CWE-672: Operation on a Resource after Expiration or Release",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:54.435Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37204",
"datePublished": "2022-02-09T15:16:56.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-04-18T18:33:01.575Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37185 (GCVE-0-2021-37185)
Vulnerability from cvelistv5 – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Severity ?
CWE
- CWE-672 - Operation on a Resource after Expiration or Release
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions >= V2.9.2 < V2.9.4
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.183Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37185",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:41.029825Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-18T18:33:19.110Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V21.9 \u003c V21.9.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-672",
"description": "CWE-672: Operation on a Resource after Expiration or Release",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:53.394Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37185",
"datePublished": "2022-02-09T15:16:44.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-04-18T18:33:19.110Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-28397 (GCVE-0-2020-28397)
Vulnerability from cvelistv5 – Published: 2021-08-10 10:35 – Updated: 2024-08-04 16:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
Severity ?
No CVSS data available.
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions < V2.9.2
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:59.119Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"product": "SIMATIC S7 PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e V2 \u003c V4"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "Version V4.4"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e V2.5 \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e V2.5 \u003c V21.9"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "Version V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:15",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-28397",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Drive Controller family",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V21.9"
}
]
}
},
{
"product_name": "SIMATIC S7 PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003e V2 \u003c V4"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "Version V4.4"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003e V2.5 \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003e V2.5 \u003c V21.9"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "Version V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-863: Incorrect Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-28397",
"datePublished": "2021-08-10T10:35:23",
"dateReserved": "2020-11-10T00:00:00",
"dateUpdated": "2024-08-04T16:33:59.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3449 (GCVE-0-2021-3449)
Vulnerability from cvelistv5 – Published: 2021-03-25 14:25 – Updated: 2024-09-17 03:43
VLAI?
Title
NULL pointer deref in signature_algorithms processing
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
Severity ?
No CVSS data available.
CWE
- NULL pointer dereference
Assigner
References
| URL | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Impacted products
Credits
Peter Kästle (Nokia) and Samuel Sapalski (Nokia)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T16:53:17.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.openssl.org/news/secadv/20210325.txt"
},
{
"tags": [
"x_transferred"
],
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
},
{
"name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
},
{
"name": "DSA-4875",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2021/dsa-4875"
},
{
"name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
},
{
"name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
},
{
"name": "GLSA-202103-03",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202103-03"
},
{
"name": "FEDORA-2021-cbf14ab8f9",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-10"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-09"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-06"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2021-05"
},
{
"tags": [
"x_transferred"
],
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com//security-alerts/cpujul2021.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
},
{
"name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpujul2022.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenSSL",
"vendor": "OpenSSL",
"versions": [
{
"status": "affected",
"version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
}
],
"datePublic": "2021-03-25T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
}
],
"metrics": [
{
"other": {
"content": {
"lang": "eng",
"url": "https://www.openssl.org/policies/secpolicy.html#High",
"value": "High"
},
"type": "unknown"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "NULL pointer dereference",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-21T19:05:57.096577",
"orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"shortName": "openssl"
},
"references": [
{
"url": "https://www.openssl.org/news/secadv/20210325.txt"
},
{
"url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
},
{
"name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
},
{
"name": "DSA-4875",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2021/dsa-4875"
},
{
"name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
},
{
"name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
},
{
"name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
},
{
"name": "GLSA-202103-03",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202103-03"
},
{
"name": "FEDORA-2021-cbf14ab8f9",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
},
{
"url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
},
{
"url": "https://www.tenable.com/security/tns-2021-10"
},
{
"url": "https://www.tenable.com/security/tns-2021-09"
},
{
"url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
},
{
"url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
},
{
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
},
{
"url": "https://www.tenable.com/security/tns-2021-06"
},
{
"url": "https://www.tenable.com/security/tns-2021-05"
},
{
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
},
{
"url": "https://www.oracle.com//security-alerts/cpujul2021.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
},
{
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
},
{
"name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
},
{
"url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
},
{
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"url": "https://www.oracle.com/security-alerts/cpujul2022.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
}
],
"title": "NULL pointer deref in signature_algorithms processing"
}
},
"cveMetadata": {
"assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"assignerShortName": "openssl",
"cveId": "CVE-2021-3449",
"datePublished": "2021-03-25T14:25:13.659307Z",
"dateReserved": "2021-03-17T00:00:00",
"dateUpdated": "2024-09-17T03:43:55.497Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-27827 (GCVE-0-2020-27827)
Vulnerability from cvelistv5 – Published: 2021-03-18 00:00 – Updated: 2025-12-03 18:20
VLAI?
Summary
A flaw was found in multiple versions of OpenvSwitch. Specially crafted LLDP packets can cause memory to be lost when allocating data to handle specific optional TLVs, potentially causing a denial of service. The highest threat from this vulnerability is to system availability.
Severity ?
7.5 (High)
CWE
Assigner
References
| URL | Tags | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | lldp/openvswitch |
Affected:
lldpd 1.0.8, openvswitch 2.14.1, openvswitch 2.13.2, openvswitch 2.12.2, openvswitch 2.11.5, openvswitch 2.10.6, openvswitch 2.9.8, openvswitch 2.8.10, openvswitch 2.7.12, openvswitch 2.6.9
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:25:43.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1921438"
},
{
"tags": [
"x_transferred"
],
"url": "https://mail.openvswitch.org/pipermail/ovs-dev/2021-January/379471.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-941426.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-07"
},
{
"name": "FEDORA-2023-88991d2713",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JYA4AMJXCNF6UPFG36L2TPPT32C242SP/"
},
{
"name": "FEDORA-2023-c0c184a019",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3T5XHPOGIPWCRRPJUE6P3HVC5PTSD5JS/"
},
{
"name": "FEDORA-2023-3e4feeadec",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SKQWHG2SZJZSGC7PXVDAEJYBN7ESDR7D/"
},
{
"name": "GLSA-202311-16",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202311-16"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-27827",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-04T13:38:48.935265Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-03T18:20:03.875Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "lldp/openvswitch",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "lldpd 1.0.8, openvswitch 2.14.1, openvswitch 2.13.2, openvswitch 2.12.2, openvswitch 2.11.5, openvswitch 2.10.6, openvswitch 2.9.8, openvswitch 2.8.10, openvswitch 2.7.12, openvswitch 2.6.9"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in multiple versions of OpenvSwitch. Specially crafted LLDP packets can cause memory to be lost when allocating data to handle specific optional TLVs, potentially causing a denial of service. The highest threat from this vulnerability is to system availability."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-26T11:06:15.202Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1921438"
},
{
"url": "https://mail.openvswitch.org/pipermail/ovs-dev/2021-January/379471.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-941426.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-07"
},
{
"name": "FEDORA-2023-88991d2713",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/JYA4AMJXCNF6UPFG36L2TPPT32C242SP/"
},
{
"name": "FEDORA-2023-c0c184a019",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3T5XHPOGIPWCRRPJUE6P3HVC5PTSD5JS/"
},
{
"name": "FEDORA-2023-3e4feeadec",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SKQWHG2SZJZSGC7PXVDAEJYBN7ESDR7D/"
},
{
"name": "GLSA-202311-16",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202311-16"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2020-27827",
"datePublished": "2021-03-18T00:00:00.000Z",
"dateReserved": "2020-10-27T00:00:00.000Z",
"dateUpdated": "2025-12-03T18:20:03.875Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6568 (GCVE-0-2019-6568)
Vulnerability from cvelistv5 – Published: 2019-04-17 13:40 – Updated: 2024-08-04 20:23
VLAI?
Summary
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise availability of the device.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1604 |
Affected:
All versions
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC DiagMonitor",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF182C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF185C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF186C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF188C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF600R family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RFID 181EIP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0 SP1 UPD1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.6 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V5.1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V5.1 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.6 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V5.1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V5.1 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF9"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.6 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V5.1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V5.1 SP1 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S210",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1 SP1 HF8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF33"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2 HF10"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM150 V4.8 (Control Unit)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 343-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.16"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP Manager",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-09T11:51:03.049Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6568",
"datePublished": "2019-04-17T13:40:24",
"dateReserved": "2019-01-22T00:00:00",
"dateUpdated": "2024-08-04T20:23:22.207Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-13816 (GCVE-0-2018-13816)
Vulnerability from cvelistv5 – Published: 2018-12-12 16:00 – Updated: 2024-08-05 09:14
VLAI?
Summary
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | TIM 1531 IRC |
Affected:
TIM 1531 IRC : All version < V2.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:14:47.170Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
},
{
"name": "106194",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106194"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "TIM 1531 IRC",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "TIM 1531 IRC : All version \u003c V2.0"
}
]
}
],
"datePublic": "2018-12-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in TIM 1531 IRC (All version \u003c V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-14T10:57:02",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
},
{
"name": "106194",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106194"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-13816",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "TIM 1531 IRC",
"version": {
"version_data": [
{
"version_value": "TIM 1531 IRC : All version \u003c V2.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in TIM 1531 IRC (All version \u003c V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
},
{
"name": "106194",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106194"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-13816",
"datePublished": "2018-12-12T16:00:00",
"dateReserved": "2018-07-10T00:00:00",
"dateUpdated": "2024-08-05T09:14:47.170Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",