Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for solid_edge_se2026 by siemens

    CVE-2026-44411 (GCVE-0-2026-44411)

    Vulnerability from nvd – Published: 2026-05-12 08:21 – Updated: 2026-05-12 12:39
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2026 (All versions < V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-824 - Access of Uninitialized Pointer
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 5 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44411",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-12T12:36:53.458325Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-12T12:39:00.293Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2026 (All versions \u003c V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824: Access of Uninitialized Pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-12T08:21:19.339Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-921111.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-44411",
        "datePublished": "2026-05-12T08:21:19.339Z",
        "dateReserved": "2026-05-06T09:51:05.262Z",
        "dateUpdated": "2026-05-12T12:39:00.293Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40745 (GCVE-0-2025-40745)

    Vulnerability from nvd – Published: 2026-04-14 08:40 – Updated: 2026-04-14 13:38
    VLAI
    Summary
    A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-295 - Improper Certificate Validation
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40745",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-14T13:37:06.968025Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-14T13:38:29.751Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Siemens Software Center",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.5.8.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter 3D",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.6000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter STAR-CCM+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2602",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2504.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Siemens Software Center (All versions \u003c V3.5.8.2), Simcenter 3D (All versions \u003c V2506.6000), Simcenter Femap (All versions \u003c V2506.0002), Simcenter STAR-CCM+ (All versions \u003c V2602), Solid Edge SE2025 (All versions \u003c V225.0 Update 13), Solid Edge SE2026 (All versions \u003c V226.0 Update 04), Tecnomatix Plant Simulation (All versions \u003c V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-295",
                  "description": "CWE-295: Improper Certificate Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-14T08:40:38.637Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-981622.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40745",
        "datePublished": "2026-04-14T08:40:38.637Z",
        "dateReserved": "2025-04-16T08:39:30.030Z",
        "dateUpdated": "2026-04-14T13:38:29.751Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44411 (GCVE-0-2026-44411)

    Vulnerability from cvelistv5 – Published: 2026-05-12 08:21 – Updated: 2026-05-12 12:39
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2026 (All versions < V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-824 - Access of Uninitialized Pointer
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 5 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44411",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-12T12:36:53.458325Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-12T12:39:00.293Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2026 (All versions \u003c V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824: Access of Uninitialized Pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-12T08:21:19.339Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-921111.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-44411",
        "datePublished": "2026-05-12T08:21:19.339Z",
        "dateReserved": "2026-05-06T09:51:05.262Z",
        "dateUpdated": "2026-05-12T12:39:00.293Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40745 (GCVE-0-2025-40745)

    Vulnerability from cvelistv5 – Published: 2026-04-14 08:40 – Updated: 2026-04-14 13:38
    VLAI
    Summary
    A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-295 - Improper Certificate Validation
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40745",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-14T13:37:06.968025Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-14T13:38:29.751Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Siemens Software Center",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.5.8.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter 3D",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.6000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter STAR-CCM+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2602",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Tecnomatix Plant Simulation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2504.0008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Siemens Software Center (All versions \u003c V3.5.8.2), Simcenter 3D (All versions \u003c V2506.6000), Simcenter Femap (All versions \u003c V2506.0002), Simcenter STAR-CCM+ (All versions \u003c V2602), Solid Edge SE2025 (All versions \u003c V225.0 Update 13), Solid Edge SE2026 (All versions \u003c V226.0 Update 04), Tecnomatix Plant Simulation (All versions \u003c V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-295",
                  "description": "CWE-295: Improper Certificate Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-14T08:40:38.637Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-981622.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40745",
        "datePublished": "2026-04-14T08:40:38.637Z",
        "dateReserved": "2025-04-16T08:39:30.030Z",
        "dateUpdated": "2026-04-14T13:38:29.751Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }