Search

Find a vulnerability

Search criteria

    52 vulnerabilities found for simatic_pcs_neo by siemens

    CVE-2025-40798 (GCVE-0-2025-40798)

    Vulnerability from nvd – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:34 UTC
    CWE
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40798",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:34:00.300219Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:34:10.734Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:47.939Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40798",
        "datePublished": "2025-09-09T08:48:05.138Z",
        "dateReserved": "2025-04-16T08:50:26.973Z",
        "dateUpdated": "2026-06-09T08:46:47.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40797 (GCVE-0-2025-40797)

    Vulnerability from nvd – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:34 UTC
    CWE
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40797",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:34:24.612370Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:34:32.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:46.861Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40797",
        "datePublished": "2025-09-09T08:48:03.853Z",
        "dateReserved": "2025-04-16T08:50:26.973Z",
        "dateUpdated": "2026-06-09T08:46:46.861Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40796 (GCVE-0-2025-40796)

    Vulnerability from nvd – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:34 UTC
    CWE
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40796",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:34:46.996504Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:34:55.540Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:45.809Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40796",
        "datePublished": "2025-09-09T08:48:02.550Z",
        "dateReserved": "2025-04-16T08:50:26.972Z",
        "dateUpdated": "2026-06-09T08:46:45.809Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40795 (GCVE-0-2025-40795)

    Vulnerability from nvd – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:35 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40795",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:35:09.103555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:35:17.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:44.543Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40795",
        "datePublished": "2025-09-09T08:48:00.987Z",
        "dateReserved": "2025-04-16T08:50:26.972Z",
        "dateUpdated": "2026-06-09T08:46:44.543Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40566 (GCVE-0-2025-40566)

    Vulnerability from nvd – Published: 2025-05-13 09:38 – Updated: 2025-05-13 18:47
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 18:46 UTC
    CWE
    • CWE-613 - Insufficient Session Expiration
    Impacted products
    Vendor Product Version
    Siemens SIMATIC PCS neo V4.1 Affected: 0 , < V4.1 Update 3 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V5.0 Affected: 0 , < V5.0 Update 1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40566",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T18:46:51.194419Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T18:47:35.480Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.0 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user\u0027s session even after logout."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-613",
                  "description": "CWE-613: Insufficient Session Expiration",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-13T09:38:52.993Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-339086.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40566",
        "datePublished": "2025-05-13T09:38:52.993Z",
        "dateReserved": "2025-04-16T08:20:17.031Z",
        "dateUpdated": "2025-05-13T18:47:35.480Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-30176 (GCVE-0-2025-30176)

    Vulnerability from nvd – Published: 2025-05-13 09:38 – Updated: 2025-07-08 10:34
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 15:26 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30176",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T15:26:49.916543Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T15:33:46.069Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V19",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions \u003c V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions \u003c V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:35.475Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-614723.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-30176",
        "datePublished": "2025-05-13T09:38:39.738Z",
        "dateReserved": "2025-03-17T13:17:40.964Z",
        "dateUpdated": "2025-07-08T10:34:35.475Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-30175 (GCVE-0-2025-30175)

    Vulnerability from nvd – Published: 2025-05-13 09:38 – Updated: 2025-07-08 10:34
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 15:35 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30175",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T15:35:16.677975Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T15:35:40.466Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V19",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions \u003c V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions \u003c V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:34.185Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-614723.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-30175",
        "datePublished": "2025-05-13T09:38:38.404Z",
        "dateReserved": "2025-03-17T13:17:40.964Z",
        "dateUpdated": "2025-07-08T10:34:34.185Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-33698 (GCVE-0-2024-33698)

    Vulnerability from nvd – Published: 2024-09-10 09:36 – Updated: 2025-10-14 09:15
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-10 17:32 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Siemens Opcenter Quality Affected: 0 , < V2406 (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < V2410 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V4.0 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V4.1 Affected: 0 , < V4.1 Update 2 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V5.0 Affected: 0 , < V5.0 Update 1 (custom)
    Create a notification for this product.
    Siemens SINEC NMS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEMA Remote Connect Client Affected: 0 , < V3.2 SP3 (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V16 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V17 Affected: 0 , < V17 Update 8 (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V18 Affected: 0 , < V18 Update 5 (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V19 Affected: 0 , < V19 Update 3 (custom)
    Create a notification for this product.
    siemens simatic_pcs_neo Affected: 4.0 , < 4.1_update_2 (custom)
        cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_information_server Affected: 0 , < * (custom)
        cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens totally_integrated_automation_portal Affected: 17 , < 17_update_8 (custom)
        cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_pcs_neo",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "4.1_update_2",
                    "status": "affected",
                    "version": "4.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_information_server",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "totally_integrated_automation_portal",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17_update_8",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-33698",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-10T17:32:07.999463Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-10T18:26:36.889Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter RDnL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2410",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1 Update 2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.0 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect Client",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.2 SP3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V19",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V19 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2406), Opcenter RDnL (All versions \u003c V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions \u003c V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T09:15:00.448Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-039007.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-33698",
        "datePublished": "2024-09-10T09:36:31.009Z",
        "dateReserved": "2024-04-26T12:32:09.263Z",
        "dateUpdated": "2025-10-14T09:15:00.448Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45147 (GCVE-0-2022-45147)

    Vulnerability from nvd – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:32
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-09 13:30 UTC
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Impacted products
    Vendor Product Version
    Siemens SIMATIC PCS neo V4.0 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC STEP 7 V16 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC STEP 7 V17 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC STEP 7 V18 Affected: 0 , < V18 Update 2 (custom)
    Create a notification for this product.
    siemens simatic_pcs_neo Affected: 4.0 , < 5.0 (custom)
        cpe:2.3:a:siemens:simatic_pcs_neo:4.0:-:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_step_7 Affected: 16 , < 17 (custom)
    Affected: 17 , < 18 (custom)
    Affected: 18 , < 18_update_2 (custom)
        cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_pcs_neo:4.0:-:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_pcs_neo",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "5.0",
                    "status": "affected",
                    "version": "4.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_step_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17",
                    "status": "affected",
                    "version": "16",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18_update_2",
                    "status": "affected",
                    "version": "18",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_step_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17",
                    "status": "affected",
                    "version": "16",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18_update_2",
                    "status": "affected",
                    "version": "18",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_step_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17",
                    "status": "affected",
                    "version": "16",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18_update_2",
                    "status": "affected",
                    "version": "18",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45147",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T13:30:52.115552Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:32:52.249Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:56.615Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-825651.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502: Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T12:04:22.545Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-825651.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-45147",
        "datePublished": "2024-07-09T12:04:22.545Z",
        "dateReserved": "2022-11-11T08:33:16.611Z",
        "dateUpdated": "2025-08-27T20:32:52.249Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46285 (GCVE-0-2023-46285)

    Vulnerability from nvd – Published: 2023-12-12 11:27 – Updated: 2025-05-24 10:24
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-20 05:00 UTC
    CWE
    • CWE-20 - Improper Input Validation
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.610Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46285",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-20T05:00:31.916630Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-24T10:24:30.154Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:55.697Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46285",
        "datePublished": "2023-12-12T11:27:17.080Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2025-05-24T10:24:30.154Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46284 (GCVE-0-2023-46284)

    Vulnerability from nvd – Published: 2023-12-12 11:27 – Updated: 2026-02-25 16:34
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-20 05:00 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.702Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46284",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-20T05:00:31.197555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-25T16:34:35.352Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:54.329Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46284",
        "datePublished": "2023-12-12T11:27:15.737Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2026-02-25T16:34:35.352Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-46283 (GCVE-0-2023-46283)

    Vulnerability from nvd – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.675Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:52.922Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46283",
        "datePublished": "2023-12-12T11:27:14.437Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2025-01-14T10:29:52.922Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46282 (GCVE-0-2023-46282)

    Vulnerability from nvd – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:40.314Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:51.618Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46282",
        "datePublished": "2023-12-12T11:27:13.134Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2025-01-14T10:29:51.618Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46281 (GCVE-0-2023-46281)

    Vulnerability from nvd – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-08 14:41 UTC
    CWE
    • CWE-942 - Permissive Cross-domain Policy with Untrusted Domains
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:40.334Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-08T14:41:24.487753Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-08T14:41:45.644Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-942",
                  "description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:50.318Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46281",
        "datePublished": "2023-12-12T11:27:11.796Z",
        "dateReserved": "2023-10-20T10:29:46.259Z",
        "dateUpdated": "2025-01-14T10:29:50.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46099 (GCVE-0-2023-46099)

    Vulnerability from nvd – Published: 2023-11-14 11:04 – Updated: 2025-01-08 16:21
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2023-12-09 05:05 UTC
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Impacted products
    Vendor Product Version
    Siemens SIMATIC PCS neo Affected: All versions < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:39.392Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46099",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2023-12-09T05:05:27.027267Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-08T16:21:04.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-14T11:04:21.326Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46099",
        "datePublished": "2023-11-14T11:04:21.326Z",
        "dateReserved": "2023-10-16T11:24:12.686Z",
        "dateUpdated": "2025-01-08T16:21:04.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46098 (GCVE-0-2023-46098)

    Vulnerability from nvd – Published: 2023-11-14 11:04 – Updated: 2025-01-08 16:35
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2023-12-09 05:05 UTC
    CWE
    • CWE-942 - Permissive Cross-domain Policy with Untrusted Domains
    Impacted products
    Vendor Product Version
    Siemens SIMATIC PCS neo Affected: All versions < V4.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:39.455Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46098",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2023-12-09T05:05:24.120438Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-08T16:35:08.154Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo (All versions \u003c V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-942",
                  "description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-14T11:04:20.174Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46098",
        "datePublished": "2023-11-14T11:04:20.174Z",
        "dateReserved": "2023-10-16T11:24:12.686Z",
        "dateUpdated": "2025-01-08T16:35:08.154Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-40798 (GCVE-0-2025-40798)

    Vulnerability from cvelistv5 – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:34 UTC
    CWE
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40798",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:34:00.300219Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:34:10.734Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:47.939Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40798",
        "datePublished": "2025-09-09T08:48:05.138Z",
        "dateReserved": "2025-04-16T08:50:26.973Z",
        "dateUpdated": "2026-06-09T08:46:47.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40797 (GCVE-0-2025-40797)

    Vulnerability from cvelistv5 – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:34 UTC
    CWE
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40797",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:34:24.612370Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:34:32.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:46.861Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40797",
        "datePublished": "2025-09-09T08:48:03.853Z",
        "dateReserved": "2025-04-16T08:50:26.973Z",
        "dateUpdated": "2026-06-09T08:46:46.861Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40796 (GCVE-0-2025-40796)

    Vulnerability from cvelistv5 – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:34 UTC
    CWE
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40796",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:34:46.996504Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:34:55.540Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:45.809Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40796",
        "datePublished": "2025-09-09T08:48:02.550Z",
        "dateReserved": "2025-04-16T08:50:26.972Z",
        "dateUpdated": "2026-06-09T08:46:45.809Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40795 (GCVE-0-2025-40795)

    Vulnerability from cvelistv5 – Published: 2025-09-09 08:48 – Updated: 2026-06-09 08:46
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-09 19:35 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40795",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-09T19:35:09.103555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-09T19:35:17.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V6.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions \u003c V6.0 SP1 Update 1), User Management Component (UMC) (All versions \u003c V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-09T08:46:44.543Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-722410.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40795",
        "datePublished": "2025-09-09T08:48:00.987Z",
        "dateReserved": "2025-04-16T08:50:26.972Z",
        "dateUpdated": "2026-06-09T08:46:44.543Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-40566 (GCVE-0-2025-40566)

    Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-05-13 18:47
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 18:46 UTC
    CWE
    • CWE-613 - Insufficient Session Expiration
    Impacted products
    Vendor Product Version
    Siemens SIMATIC PCS neo V4.1 Affected: 0 , < V4.1 Update 3 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V5.0 Affected: 0 , < V5.0 Update 1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-40566",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T18:46:51.194419Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T18:47:35.480Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.0 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user\u0027s session even after logout."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-613",
                  "description": "CWE-613: Insufficient Session Expiration",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-13T09:38:52.993Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-339086.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-40566",
        "datePublished": "2025-05-13T09:38:52.993Z",
        "dateReserved": "2025-04-16T08:20:17.031Z",
        "dateUpdated": "2025-05-13T18:47:35.480Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-30176 (GCVE-0-2025-30176)

    Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-07-08 10:34
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 15:26 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30176",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T15:26:49.916543Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T15:33:46.069Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V19",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions \u003c V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions \u003c V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:35.475Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-614723.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-30176",
        "datePublished": "2025-05-13T09:38:39.738Z",
        "dateReserved": "2025-03-17T13:17:40.964Z",
        "dateUpdated": "2025-07-08T10:34:35.475Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-30175 (GCVE-0-2025-30175)

    Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-07-08 10:34
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-13 15:35 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30175",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-13T15:35:16.677975Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-13T15:35:40.466Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V19",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions \u003c V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions \u003c V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-08T10:34:34.185Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-614723.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-30175",
        "datePublished": "2025-05-13T09:38:38.404Z",
        "dateReserved": "2025-03-17T13:17:40.964Z",
        "dateUpdated": "2025-07-08T10:34:34.185Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-33698 (GCVE-0-2024-33698)

    Vulnerability from cvelistv5 – Published: 2024-09-10 09:36 – Updated: 2025-10-14 09:15
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-10 17:32 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Siemens Opcenter Quality Affected: 0 , < V2406 (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < V2410 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V4.0 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V4.1 Affected: 0 , < V4.1 Update 2 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo V5.0 Affected: 0 , < V5.0 Update 1 (custom)
    Create a notification for this product.
    Siemens SINEC NMS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEMA Remote Connect Client Affected: 0 , < V3.2 SP3 (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V16 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V17 Affected: 0 , < V17 Update 8 (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V18 Affected: 0 , < V18 Update 5 (custom)
    Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V19 Affected: 0 , < V19 Update 3 (custom)
    Create a notification for this product.
    siemens simatic_pcs_neo Affected: 4.0 , < 4.1_update_2 (custom)
        cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_information_server Affected: 0 , < * (custom)
        cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*
        cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens totally_integrated_automation_portal Affected: 17 , < 17_update_8 (custom)
        cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_pcs_neo",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "4.1_update_2",
                    "status": "affected",
                    "version": "4.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*",
                  "cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_information_server",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "totally_integrated_automation_portal",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17_update_8",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-33698",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-10T17:32:07.999463Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-10T18:26:36.889Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2406",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter RDnL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2410",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1 Update 2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V5.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.0 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect Client",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.2 SP3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V19",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V19 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2406), Opcenter RDnL (All versions \u003c V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions \u003c V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T09:15:00.448Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-039007.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-33698",
        "datePublished": "2024-09-10T09:36:31.009Z",
        "dateReserved": "2024-04-26T12:32:09.263Z",
        "dateUpdated": "2025-10-14T09:15:00.448Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45147 (GCVE-0-2022-45147)

    Vulnerability from cvelistv5 – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:32
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-09 13:30 UTC
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    Impacted products
    Vendor Product Version
    Siemens SIMATIC PCS neo V4.0 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC STEP 7 V16 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC STEP 7 V17 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC STEP 7 V18 Affected: 0 , < V18 Update 2 (custom)
    Create a notification for this product.
    siemens simatic_pcs_neo Affected: 4.0 , < 5.0 (custom)
        cpe:2.3:a:siemens:simatic_pcs_neo:4.0:-:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_step_7 Affected: 16 , < 17 (custom)
    Affected: 17 , < 18 (custom)
    Affected: 18 , < 18_update_2 (custom)
        cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_pcs_neo:4.0:-:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_pcs_neo",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "5.0",
                    "status": "affected",
                    "version": "4.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_step_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17",
                    "status": "affected",
                    "version": "16",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18_update_2",
                    "status": "affected",
                    "version": "18",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_step_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17",
                    "status": "affected",
                    "version": "16",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18_update_2",
                    "status": "affected",
                    "version": "18",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_step_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "17",
                    "status": "affected",
                    "version": "16",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18",
                    "status": "affected",
                    "version": "17",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "18_update_2",
                    "status": "affected",
                    "version": "18",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45147",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T13:30:52.115552Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:32:52.249Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:56.615Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-825651.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502: Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T12:04:22.545Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-825651.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-45147",
        "datePublished": "2024-07-09T12:04:22.545Z",
        "dateReserved": "2022-11-11T08:33:16.611Z",
        "dateUpdated": "2025-08-27T20:32:52.249Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46285 (GCVE-0-2023-46285)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:27 – Updated: 2025-05-24 10:24
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-20 05:00 UTC
    CWE
    • CWE-20 - Improper Input Validation
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.610Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46285",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-20T05:00:31.916630Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-24T10:24:30.154Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:55.697Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46285",
        "datePublished": "2023-12-12T11:27:17.080Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2025-05-24T10:24:30.154Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46284 (GCVE-0-2023-46284)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:27 – Updated: 2026-02-25 16:34
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-20 05:00 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.702Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46284",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-20T05:00:31.197555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-25T16:34:35.352Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:54.329Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46284",
        "datePublished": "2023-12-12T11:27:15.737Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2026-02-25T16:34:35.352Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-46283 (GCVE-0-2023-46283)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.675Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:52.922Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46283",
        "datePublished": "2023-12-12T11:27:14.437Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2025-01-14T10:29:52.922Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46282 (GCVE-0-2023-46282)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:40.314Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:51.618Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46282",
        "datePublished": "2023-12-12T11:27:13.134Z",
        "dateReserved": "2023-10-20T10:29:46.260Z",
        "dateUpdated": "2025-01-14T10:29:51.618Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46281 (GCVE-0-2023-46281)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:27 – Updated: 2025-01-14 10:29
    VLAI
    Summary
    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-08 14:41 UTC
    CWE
    • CWE-942 - Permissive Cross-domain Policy with Untrusted Domains
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:40.334Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-08T14:41:24.487753Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-08T14:41:45.644Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2407",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2312",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Totally Integrated Automation Portal (TIA Portal) V18",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18 Update 3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2407), Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-942",
                  "description": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:29:50.318Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-46281",
        "datePublished": "2023-12-12T11:27:11.796Z",
        "dateReserved": "2023-10-20T10:29:46.259Z",
        "dateUpdated": "2025-01-14T10:29:50.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }