Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for sage_4400 by schneider-electric

    CVE-2024-5560 (GCVE-0-2024-5560)

    Vulnerability from nvd – Published: 2024-06-12 16:45 – Updated: 2024-08-01 21:18
    VLAI
    Summary
    CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:30 UTC
    CWE
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-5560",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:30:24.462387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:32:10.472Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:18:06.538Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nCWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.\n\n"
                }
              ],
              "value": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:45:56.256Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-5560",
        "datePublished": "2024-06-12T16:45:56.256Z",
        "dateReserved": "2024-05-31T06:58:55.638Z",
        "dateUpdated": "2024-08-01T21:18:06.538Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37040 (GCVE-0-2024-37040)

    Vulnerability from nvd – Published: 2024-06-12 16:56 – Updated: 2024-08-02 03:43
    VLAI
    Summary
    CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:27 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37040",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:27:09.666436Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:34:05.093Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:43:50.968Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\n\n\n\n\n\nCWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request.\n\n\n\n\n\n\n\n\n\n\n\n"
                }
              ],
              "value": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:56:06.117Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-37040",
        "datePublished": "2024-06-12T16:56:06.117Z",
        "dateReserved": "2024-05-31T06:52:05.762Z",
        "dateUpdated": "2024-08-02T03:43:50.968Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37039 (GCVE-0-2024-37039)

    Vulnerability from nvd – Published: 2024-06-12 16:54 – Updated: 2024-08-02 03:43
    VLAI
    Summary
    CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:24 UTC
    CWE
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37039",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:24:08.466465Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:33:50.964Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:43:50.886Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\n\n\n\nCWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request.\n\n\n\n\n\n\n\n\n\n"
                }
              ],
              "value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:54:23.117Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-37039",
        "datePublished": "2024-06-12T16:54:23.117Z",
        "dateReserved": "2024-05-31T06:52:05.762Z",
        "dateUpdated": "2024-08-02T03:43:50.886Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37037 (GCVE-0-2024-37037)

    Vulnerability from nvd – Published: 2024-06-12 16:50 – Updated: 2024-08-02 03:43
    VLAI
    Summary
    CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:28 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37037",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:28:51.967522Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:33:38.098Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:43:50.902Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.\n\n\n\n\n\n"
                }
              ],
              "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:50:09.159Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-37037",
        "datePublished": "2024-06-12T16:50:09.159Z",
        "dateReserved": "2024-05-31T06:52:05.762Z",
        "dateUpdated": "2024-08-02T03:43:50.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37040 (GCVE-0-2024-37040)

    Vulnerability from cvelistv5 – Published: 2024-06-12 16:56 – Updated: 2024-08-02 03:43
    VLAI
    Summary
    CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:27 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37040",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:27:09.666436Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:34:05.093Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:43:50.968Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\n\n\n\n\n\nCWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request.\n\n\n\n\n\n\n\n\n\n\n\n"
                }
              ],
              "value": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:56:06.117Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-37040",
        "datePublished": "2024-06-12T16:56:06.117Z",
        "dateReserved": "2024-05-31T06:52:05.762Z",
        "dateUpdated": "2024-08-02T03:43:50.968Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37039 (GCVE-0-2024-37039)

    Vulnerability from cvelistv5 – Published: 2024-06-12 16:54 – Updated: 2024-08-02 03:43
    VLAI
    Summary
    CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:24 UTC
    CWE
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37039",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:24:08.466465Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:33:50.964Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:43:50.886Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\n\n\n\nCWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request.\n\n\n\n\n\n\n\n\n\n"
                }
              ],
              "value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:54:23.117Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-37039",
        "datePublished": "2024-06-12T16:54:23.117Z",
        "dateReserved": "2024-05-31T06:52:05.762Z",
        "dateUpdated": "2024-08-02T03:43:50.886Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-37037 (GCVE-0-2024-37037)

    Vulnerability from cvelistv5 – Published: 2024-06-12 16:50 – Updated: 2024-08-02 03:43
    VLAI
    Summary
    CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:28 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37037",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:28:51.967522Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:33:38.098Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:43:50.902Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.\n\n\n\n\n\n"
                }
              ],
              "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:50:09.159Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-37037",
        "datePublished": "2024-06-12T16:50:09.159Z",
        "dateReserved": "2024-05-31T06:52:05.762Z",
        "dateUpdated": "2024-08-02T03:43:50.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-5560 (GCVE-0-2024-5560)

    Vulnerability from cvelistv5 – Published: 2024-06-12 16:45 – Updated: 2024-08-01 21:18
    VLAI
    Summary
    CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 18:30 UTC
    CWE
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 23 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
    Create a notification for this product.
    schneider-electric sage_4400 Affected: 0 , ≤ c3414-500-s02k5_p8 (custom)
        cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*
        cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
                  "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sage_4400",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "c3414-500-s02k5_p8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-5560",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T18:30:24.462387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-12T18:32:10.472Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:18:06.538Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1410",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1430",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 1450",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 2400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 3030 Magnum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Sage 4400",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions C3414-500-S02K5_P8 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nCWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.\n\n"
                }
              ],
              "value": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-12T16:45:56.256Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-5560",
        "datePublished": "2024-06-12T16:45:56.256Z",
        "dateReserved": "2024-05-31T06:58:55.638Z",
        "dateUpdated": "2024-08-01T21:18:06.538Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }