Search

Find a vulnerability

Search criteria

    120 vulnerabilities found for ax1803_firmware by tenda

    CVE-2026-1329 (GCVE-0-2026-1329)

    Vulnerability from nvd – Published: 2026-01-22 14:32 – Updated: 2026-02-23 08:53
    VLAI
    Title
    Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow
    Summary
    A flaw has been found in Tenda AX1803 1.0.0.1. The affected element is the function fromGetWifiGuestBasic of the file /goform/WifiGuestSet. Executing a manipulation of the argument guestWrlPwd/guestEn/guestSsid/hideSsid/guestSecurity can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.342305 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.342305 signaturepermissions-required
    https://vuldb.com/?submit.736063 third-party-advisory
    https://vuldb.com/?submit.736064 third-party-advisory
    https://vuldb.com/?submit.736065 third-party-advisory
    https://vuldb.com/?submit.736066 third-party-advisory
    https://vuldb.com/?submit.736067 third-party-advisory
    https://river-brow-763.notion.site/Tenda-AX1803-B… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wlupus (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1329",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T15:07:23.213068Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T15:08:03.723Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wlupus (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AX1803 1.0.0.1. The affected element is the function fromGetWifiGuestBasic of the file /goform/WifiGuestSet. Executing a manipulation of the argument guestWrlPwd/guestEn/guestSsid/hideSsid/guestSecurity can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T08:53:35.403Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-342305 | Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.342305"
            },
            {
              "name": "VDB-342305 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.342305"
            },
            {
              "name": "Submit #736063 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736063"
            },
            {
              "name": "Submit #736064 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736064"
            },
            {
              "name": "Submit #736065 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736065"
            },
            {
              "name": "Submit #736066 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736066"
            },
            {
              "name": "Submit #736067 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736067"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://river-brow-763.notion.site/Tenda-AX1803-Buffer-Overflow-in-fromGetWifiGusetBasic-2e3a595a7aef80a78225db34317daa40#2e3a595a7aef801ab517e4af5631227a"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-22T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-24T15:20:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1329",
        "datePublished": "2026-01-22T14:32:18.996Z",
        "dateReserved": "2026-01-22T07:51:42.763Z",
        "dateUpdated": "2026-02-23T08:53:35.403Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-70648 (GCVE-0-2025-70648)

    Vulnerability from nvd – Published: 2026-01-21 00:00 – Updated: 2026-01-22 14:48
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security_5g parameter of the sub_727F4 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-70648",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T14:47:58.704311Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T14:48:54.824Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security_5g parameter of the sub_727F4 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-21T16:17:43.455Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/6/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-70648",
        "datePublished": "2026-01-21T00:00:00.000Z",
        "dateReserved": "2026-01-09T00:00:00.000Z",
        "dateUpdated": "2026-01-22T14:48:54.824Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-70646 (GCVE-0-2025-70646)

    Vulnerability from nvd – Published: 2026-01-21 00:00 – Updated: 2026-01-22 15:36
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security parameter of the sub_72290 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-70646",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T15:35:20.986641Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T15:36:16.326Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security parameter of the sub_72290 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-21T16:19:20.904Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/5/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-70646",
        "datePublished": "2026-01-21T00:00:00.000Z",
        "dateReserved": "2026-01-09T00:00:00.000Z",
        "dateUpdated": "2026-01-22T15:36:16.326Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-70651 (GCVE-0-2025-70651)

    Vulnerability from nvd – Published: 2026-01-21 00:00 – Updated: 2026-01-21 15:45
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow in the ssid parameter of the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-70651",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-21T15:44:05.600405Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-21T15:45:09.124Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow in the ssid parameter of the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-21T15:07:48.618Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/4/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-70651",
        "datePublished": "2026-01-21T00:00:00.000Z",
        "dateReserved": "2026-01-09T00:00:00.000Z",
        "dateUpdated": "2026-01-21T15:45:09.124Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-63457 (GCVE-0-2025-63457)

    Vulnerability from nvd – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:33
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-63457",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-12T17:05:45.526528Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-18T16:33:49.614Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-10T16:13:26.686Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/1/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-63457",
        "datePublished": "2025-11-10T00:00:00.000Z",
        "dateReserved": "2025-10-27T00:00:00.000Z",
        "dateUpdated": "2025-11-18T16:33:49.614Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-63456 (GCVE-0-2025-63456)

    Vulnerability from nvd – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:27
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-63456",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-18T16:27:20.923514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-18T16:27:47.818Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-10T16:38:44.379Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/3/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-63456",
        "datePublished": "2025-11-10T00:00:00.000Z",
        "dateReserved": "2025-10-27T00:00:00.000Z",
        "dateUpdated": "2025-11-18T16:27:47.818Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-63458 (GCVE-0-2025-63458)

    Vulnerability from nvd – Published: 2025-10-31 00:00 – Updated: 2025-11-03 14:53
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-63458",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-03T14:29:34.961702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-03T14:53:13.747Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-31T18:55:13.569Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-63458",
        "datePublished": "2025-10-31T00:00:00.000Z",
        "dateReserved": "2025-10-27T00:00:00.000Z",
        "dateUpdated": "2025-11-03T14:53:13.747Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-7598 (GCVE-0-2025-7598)

    Vulnerability from nvd – Published: 2025-07-14 11:02 – Updated: 2025-07-14 12:43
    VLAI
    Title
    Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow
    Summary
    A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
    Create a notification for this product.
    Credits
    panda_0x1 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7598",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-14T12:42:00.366931Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-14T12:43:01.808Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "panda_0x1 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda AX1803 1.0.0.1 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion formSetWifiMacFilterCfg der Datei /goform/setWifiFilterCfg. Durch die Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-14T11:02:07.422Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316297 | Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.316297"
            },
            {
              "name": "VDB-316297 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316297"
            },
            {
              "name": "Submit #615269 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.615269"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-13T15:18:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7598",
        "datePublished": "2025-07-14T11:02:07.422Z",
        "dateReserved": "2025-07-13T13:13:20.225Z",
        "dateUpdated": "2025-07-14T12:43:01.808Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7597 (GCVE-0-2025-7597)

    Vulnerability from nvd – Published: 2025-07-14 10:44 – Updated: 2025-07-14 12:46
    VLAI
    Title
    Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow
    Summary
    A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
    Create a notification for this product.
    Credits
    panda_0x1 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7597",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-14T12:46:37.870432Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-14T12:46:49.239Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "panda_0x1 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AX1803 1.0.0.1 entdeckt. Hiervon betroffen ist die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-14T10:44:06.851Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316296 | Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.316296"
            },
            {
              "name": "VDB-316296 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316296"
            },
            {
              "name": "Submit #615268 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.615268"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-13T15:18:26.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7597",
        "datePublished": "2025-07-14T10:44:06.851Z",
        "dateReserved": "2025-07-13T13:13:17.958Z",
        "dateUpdated": "2025-07-14T12:46:49.239Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4236 (GCVE-0-2024-4236)

    Vulnerability from nvd – Published: 2024-04-26 17:31 – Updated: 2024-08-01 20:33
    VLAI
    Title
    Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.262127 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.262127 signaturepermissions-required
    https://vuldb.com/?submit.319230 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
    Create a notification for this product.
    tenda ax1803 Affected: -
        cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wxhwxhwxh_mie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ax1803",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4236",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-29T11:41:30.994135Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:56:20.941Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:33:52.983Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.262127"
              },
              {
                "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.262127"
              },
              {
                "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.319230"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AX1803 1.0.0.1 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSysToolDDNS der Datei /goform/SetDDNSCfg. Durch Manipulieren des Arguments serverName/ddnsUser/ddnsPwd/ddnsDomain mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-26T17:31:09.607Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.262127"
            },
            {
              "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.262127"
            },
            {
              "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.319230"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-04-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-04-26T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-04-26T14:45:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-4236",
        "datePublished": "2024-04-26T17:31:09.607Z",
        "dateReserved": "2024-04-26T12:39:58.408Z",
        "dateUpdated": "2024-08-01T20:33:52.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-30621 (GCVE-0-2024-30621)

    Vulnerability from nvd – Published: 2024-04-02 00:00 – Updated: 2024-08-19 19:24
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    tenda ax1803_firmware Affected: 1.0.0.1
        cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:39:00.719Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ax1803_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-30621",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-02T15:30:54.859137Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-19T19:24:45.965Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-02T13:29:05.486Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-30621",
        "datePublished": "2024-04-02T00:00:00.000Z",
        "dateReserved": "2024-03-27T00:00:00.000Z",
        "dateUpdated": "2024-08-19T19:24:45.965Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-30620 (GCVE-0-2024-30620)

    Vulnerability from nvd – Published: 2024-04-02 00:00 – Updated: 2025-03-25 14:16
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    Impacted products
    Vendor Product Version
    tenda ax1803 Affected: v1.0.0.1
        cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ax1803",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.0.0.1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-30620",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-03T14:11:25.854407Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-120",
                    "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T14:16:22.151Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:39:00.886Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-02T13:30:12.537Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-30620",
        "datePublished": "2024-04-02T00:00:00.000Z",
        "dateReserved": "2024-03-27T00:00:00.000Z",
        "dateUpdated": "2025-03-25T14:16:22.151Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51970 (GCVE-0-2023-51970)

    Vulnerability from nvd – Published: 2024-01-10 00:00 – Updated: 2025-06-20 16:03
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:48:12.037Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51970",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T16:39:09.081867Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-20T16:03:24.187Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-10T15:19:56.776Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-51970",
        "datePublished": "2024-01-10T00:00:00.000Z",
        "dateReserved": "2023-12-26T00:00:00.000Z",
        "dateUpdated": "2025-06-20T16:03:24.187Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51969 (GCVE-0-2023-51969)

    Vulnerability from nvd – Published: 2024-01-10 00:00 – Updated: 2025-06-20 16:02
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function getIptvInfo.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:48:11.985Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51969",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-11T15:56:07.797280Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-20T16:02:36.618Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function getIptvInfo."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-10T15:20:53.706Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-51969",
        "datePublished": "2024-01-10T00:00:00.000Z",
        "dateReserved": "2023-12-26T00:00:00.000Z",
        "dateUpdated": "2025-06-20T16:02:36.618Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51968 (GCVE-0-2023-51968)

    Vulnerability from nvd – Published: 2024-01-10 00:00 – Updated: 2025-06-16 18:42
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function getIptvInfo.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:48:11.866Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51968",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-19T21:10:03.727170Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-16T18:42:34.072Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function getIptvInfo."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-10T15:22:00.276Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-51968",
        "datePublished": "2024-01-10T00:00:00.000Z",
        "dateReserved": "2023-12-26T00:00:00.000Z",
        "dateUpdated": "2025-06-16T18:42:34.072Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51967 (GCVE-0-2023-51967)

    Vulnerability from nvd – Published: 2024-01-10 00:00 – Updated: 2025-06-20 16:01
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function getIptvInfo.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:48:11.864Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51967",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T18:56:47.040196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-20T16:01:47.169Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function getIptvInfo."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-10T15:23:30.150Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-51967",
        "datePublished": "2024-01-10T00:00:00.000Z",
        "dateReserved": "2023-12-26T00:00:00.000Z",
        "dateUpdated": "2025-06-20T16:01:47.169Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51962 (GCVE-0-2023-51962)

    Vulnerability from nvd – Published: 2024-01-10 00:00 – Updated: 2025-04-17 15:57
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:48:12.077Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-setIptvInfo-944beaf189db4bf49f99a7a7418c7bdd"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51962",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-17T15:50:48.121000Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-17T15:57:38.347Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-10T15:24:54.260Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-setIptvInfo-944beaf189db4bf49f99a7a7418c7bdd"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-51962",
        "datePublished": "2024-01-10T00:00:00.000Z",
        "dateReserved": "2023-12-26T00:00:00.000Z",
        "dateUpdated": "2025-04-17T15:57:38.347Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51965 (GCVE-0-2023-51965)

    Vulnerability from nvd – Published: 2024-01-10 00:00 – Updated: 2025-06-20 16:00
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function setIptvInfo.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:48:11.803Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-setIptvInfo-944beaf189db4bf49f99a7a7418c7bdd"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51965",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T16:21:13.970115Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-20T16:00:12.235Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function setIptvInfo."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-10T15:11:14.258Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-setIptvInfo-944beaf189db4bf49f99a7a7418c7bdd"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-51965",
        "datePublished": "2024-01-10T00:00:00.000Z",
        "dateReserved": "2023-12-26T00:00:00.000Z",
        "dateUpdated": "2025-06-20T16:00:12.235Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-1329 (GCVE-0-2026-1329)

    Vulnerability from cvelistv5 – Published: 2026-01-22 14:32 – Updated: 2026-02-23 08:53
    VLAI
    Title
    Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow
    Summary
    A flaw has been found in Tenda AX1803 1.0.0.1. The affected element is the function fromGetWifiGuestBasic of the file /goform/WifiGuestSet. Executing a manipulation of the argument guestWrlPwd/guestEn/guestSsid/hideSsid/guestSecurity can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.342305 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.342305 signaturepermissions-required
    https://vuldb.com/?submit.736063 third-party-advisory
    https://vuldb.com/?submit.736064 third-party-advisory
    https://vuldb.com/?submit.736065 third-party-advisory
    https://vuldb.com/?submit.736066 third-party-advisory
    https://vuldb.com/?submit.736067 third-party-advisory
    https://river-brow-763.notion.site/Tenda-AX1803-B… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
        cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wlupus (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1329",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T15:07:23.213068Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T15:08:03.723Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wlupus (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AX1803 1.0.0.1. The affected element is the function fromGetWifiGuestBasic of the file /goform/WifiGuestSet. Executing a manipulation of the argument guestWrlPwd/guestEn/guestSsid/hideSsid/guestSecurity can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T08:53:35.403Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-342305 | Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.342305"
            },
            {
              "name": "VDB-342305 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.342305"
            },
            {
              "name": "Submit #736063 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736063"
            },
            {
              "name": "Submit #736064 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736064"
            },
            {
              "name": "Submit #736065 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736065"
            },
            {
              "name": "Submit #736066 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736066"
            },
            {
              "name": "Submit #736067 | Tenda AX1803 V1.0.0.1 Stack-based Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.736067"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://river-brow-763.notion.site/Tenda-AX1803-Buffer-Overflow-in-fromGetWifiGusetBasic-2e3a595a7aef80a78225db34317daa40#2e3a595a7aef801ab517e4af5631227a"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-22T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-24T15:20:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1329",
        "datePublished": "2026-01-22T14:32:18.996Z",
        "dateReserved": "2026-01-22T07:51:42.763Z",
        "dateUpdated": "2026-02-23T08:53:35.403Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-70646 (GCVE-0-2025-70646)

    Vulnerability from cvelistv5 – Published: 2026-01-21 00:00 – Updated: 2026-01-22 15:36
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security parameter of the sub_72290 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-70646",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T15:35:20.986641Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T15:36:16.326Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security parameter of the sub_72290 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-21T16:19:20.904Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/5/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-70646",
        "datePublished": "2026-01-21T00:00:00.000Z",
        "dateReserved": "2026-01-09T00:00:00.000Z",
        "dateUpdated": "2026-01-22T15:36:16.326Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-70648 (GCVE-0-2025-70648)

    Vulnerability from cvelistv5 – Published: 2026-01-21 00:00 – Updated: 2026-01-22 14:48
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security_5g parameter of the sub_727F4 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-70648",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T14:47:58.704311Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T14:48:54.824Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow in the security_5g parameter of the sub_727F4 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-21T16:17:43.455Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/6/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-70648",
        "datePublished": "2026-01-21T00:00:00.000Z",
        "dateReserved": "2026-01-09T00:00:00.000Z",
        "dateUpdated": "2026-01-22T14:48:54.824Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-70651 (GCVE-0-2025-70651)

    Vulnerability from cvelistv5 – Published: 2026-01-21 00:00 – Updated: 2026-01-21 15:45
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow in the ssid parameter of the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-70651",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-21T15:44:05.600405Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-21T15:45:09.124Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow in the ssid parameter of the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-21T15:07:48.618Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/4/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-70651",
        "datePublished": "2026-01-21T00:00:00.000Z",
        "dateReserved": "2026-01-09T00:00:00.000Z",
        "dateUpdated": "2026-01-21T15:45:09.124Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-63456 (GCVE-0-2025-63456)

    Vulnerability from cvelistv5 – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:27
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-63456",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-18T16:27:20.923514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-18T16:27:47.818Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-10T16:38:44.379Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/3/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-63456",
        "datePublished": "2025-11-10T00:00:00.000Z",
        "dateReserved": "2025-10-27T00:00:00.000Z",
        "dateUpdated": "2025-11-18T16:27:47.818Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-63457 (GCVE-0-2025-63457)

    Vulnerability from cvelistv5 – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:33
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-63457",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-12T17:05:45.526528Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-18T16:33:49.614Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-10T16:13:26.686Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/1/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-63457",
        "datePublished": "2025-11-10T00:00:00.000Z",
        "dateReserved": "2025-10-27T00:00:00.000Z",
        "dateUpdated": "2025-11-18T16:33:49.614Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-63458 (GCVE-0-2025-63458)

    Vulnerability from cvelistv5 – Published: 2025-10-31 00:00 – Updated: 2025-11-03 14:53
    VLAI
    Summary
    Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-63458",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-03T14:29:34.961702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-03T14:53:13.747Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-31T18:55:13.569Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-63458",
        "datePublished": "2025-10-31T00:00:00.000Z",
        "dateReserved": "2025-10-27T00:00:00.000Z",
        "dateUpdated": "2025-11-03T14:53:13.747Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-7598 (GCVE-0-2025-7598)

    Vulnerability from cvelistv5 – Published: 2025-07-14 11:02 – Updated: 2025-07-14 12:43
    VLAI
    Title
    Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow
    Summary
    A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
    Create a notification for this product.
    Credits
    panda_0x1 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7598",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-14T12:42:00.366931Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-14T12:43:01.808Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "panda_0x1 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda AX1803 1.0.0.1 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion formSetWifiMacFilterCfg der Datei /goform/setWifiFilterCfg. Durch die Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-14T11:02:07.422Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316297 | Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.316297"
            },
            {
              "name": "VDB-316297 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316297"
            },
            {
              "name": "Submit #615269 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.615269"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-13T15:18:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7598",
        "datePublished": "2025-07-14T11:02:07.422Z",
        "dateReserved": "2025-07-13T13:13:20.225Z",
        "dateUpdated": "2025-07-14T12:43:01.808Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7597 (GCVE-0-2025-7597)

    Vulnerability from cvelistv5 – Published: 2025-07-14 10:44 – Updated: 2025-07-14 12:46
    VLAI
    Title
    Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow
    Summary
    A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
    Create a notification for this product.
    Credits
    panda_0x1 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7597",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-14T12:46:37.870432Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-14T12:46:49.239Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "panda_0x1 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AX1803 1.0.0.1 entdeckt. Hiervon betroffen ist die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-14T10:44:06.851Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316296 | Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.316296"
            },
            {
              "name": "VDB-316296 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316296"
            },
            {
              "name": "Submit #615268 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.615268"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-13T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-13T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-13T15:18:26.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7597",
        "datePublished": "2025-07-14T10:44:06.851Z",
        "dateReserved": "2025-07-13T13:13:17.958Z",
        "dateUpdated": "2025-07-14T12:46:49.239Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4236 (GCVE-0-2024-4236)

    Vulnerability from cvelistv5 – Published: 2024-04-26 17:31 – Updated: 2024-08-01 20:33
    VLAI
    Title
    Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.262127 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.262127 signaturepermissions-required
    https://vuldb.com/?submit.319230 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AX1803 Affected: 1.0.0.1
    Create a notification for this product.
    tenda ax1803 Affected: -
        cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wxhwxhwxh_mie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ax1803",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4236",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-29T11:41:30.994135Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:56:20.941Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:33:52.983Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.262127"
              },
              {
                "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.262127"
              },
              {
                "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.319230"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AX1803",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AX1803 1.0.0.1 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSysToolDDNS der Datei /goform/SetDDNSCfg. Durch Manipulieren des Arguments serverName/ddnsUser/ddnsPwd/ddnsDomain mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-26T17:31:09.607Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.262127"
            },
            {
              "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.262127"
            },
            {
              "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.319230"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-04-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-04-26T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-04-26T14:45:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-4236",
        "datePublished": "2024-04-26T17:31:09.607Z",
        "dateReserved": "2024-04-26T12:39:58.408Z",
        "dateUpdated": "2024-08-01T20:33:52.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-30621 (GCVE-0-2024-30621)

    Vulnerability from cvelistv5 – Published: 2024-04-02 00:00 – Updated: 2024-08-19 19:24
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    tenda ax1803_firmware Affected: 1.0.0.1
        cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:39:00.719Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ax1803_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-30621",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-02T15:30:54.859137Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-19T19:24:45.965Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-02T13:29:05.486Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-30621",
        "datePublished": "2024-04-02T00:00:00.000Z",
        "dateReserved": "2024-03-27T00:00:00.000Z",
        "dateUpdated": "2024-08-19T19:24:45.965Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-30620 (GCVE-0-2024-30620)

    Vulnerability from cvelistv5 – Published: 2024-04-02 00:00 – Updated: 2025-03-25 14:16
    VLAI
    Summary
    Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    Impacted products
    Vendor Product Version
    tenda ax1803 Affected: v1.0.0.1
        cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ax1803",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.0.0.1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-30620",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-03T14:11:25.854407Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-120",
                    "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T14:16:22.151Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:39:00.886Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-02T13:30:12.537Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-30620",
        "datePublished": "2024-04-02T00:00:00.000Z",
        "dateReserved": "2024-03-27T00:00:00.000Z",
        "dateUpdated": "2025-03-25T14:16:22.151Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }