Search

Find a vulnerability

Search criteria

    182 vulnerabilities found for ac9_firmware by tenda

    CVE-2026-6016 (GCVE-0-2026-6016)

    Vulnerability from nvd – Published: 2026-04-10 05:00 – Updated: 2026-04-10 13:40
    VLAI
    Title
    Tenda AC9 POST Request WizardHandle decodePwd stack-based overflow
    Summary
    A vulnerability was found in Tenda AC9 15.03.02.13. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Performing a manipulation of the argument WANS results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wxhwxhwxh_mie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6016",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-10T13:39:55.830180Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-10T13:40:04.879Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC9 15.03.02.13. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Performing a manipulation of the argument WANS results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-10T05:00:23.163Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-356572 | Tenda AC9 POST Request WizardHandle decodePwd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/356572"
            },
            {
              "name": "VDB-356572 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/356572/cti"
            },
            {
              "name": "Submit #791829 | Tenda AC9 AC9 V1.0 V15.03.02.13 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/791829"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC9-WizardHandle-33153a41781f808480f9e3b78ce438e0?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-09T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-09T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-09T16:43:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request WizardHandle decodePwd stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6016",
        "datePublished": "2026-04-10T05:00:23.163Z",
        "dateReserved": "2026-04-09T14:38:10.228Z",
        "dateUpdated": "2026-04-10T13:40:04.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-6015 (GCVE-0-2026-6015)

    Vulnerability from nvd – Published: 2026-04-10 04:45 – Updated: 2026-04-14 14:34
    VLAI
    Title
    Tenda AC9 POST Request QuickIndex formQuickIndex stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC9 15.03.02.13. Impacted is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. Such manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wxhwxhwxh_mie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6015",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-14T14:33:59.437612Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-14T14:34:24.148Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC9 15.03.02.13. Impacted is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. Such manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-10T04:45:15.605Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-356571 | Tenda AC9 POST Request QuickIndex formQuickIndex stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/356571"
            },
            {
              "name": "VDB-356571 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/356571/cti"
            },
            {
              "name": "Submit #791828 | Tenda AC9 AC9 V1.0 V15.03.02.13 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/791828"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC9-QuickIndex-33153a41781f80458940f212f150a4fb?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-09T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-09T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-09T16:43:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request QuickIndex formQuickIndex stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6015",
        "datePublished": "2026-04-10T04:45:15.605Z",
        "dateReserved": "2026-04-09T14:36:50.168Z",
        "dateUpdated": "2026-04-14T14:34:24.148Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2192 (GCVE-0-2026-2192)

    Vulnerability from nvd – Published: 2026-02-08 23:02 – Updated: 2026-02-23 09:51
    VLAI
    Title
    Tenda AC9 formGetRebootTimer stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC9 15.03.06.42_multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.start_time/sys.schedulereboot.end_time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344895 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344895 signaturepermissions-required
    https://vuldb.com/?submit.749801 third-party-advisory
    https://github.com/glkfc/IoT-Vulnerability/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.06.42_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jfkk (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2192",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T16:44:38.803800Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T16:45:07.148Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.42_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jfkk (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC9 15.03.06.42_multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.start_time/sys.schedulereboot.end_time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:51:06.600Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344895 | Tenda AC9 formGetRebootTimer stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344895"
            },
            {
              "name": "VDB-344895 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344895"
            },
            {
              "name": "Submit #749801 | Tenda AC9 v1.0/V3.0 V15.03.06.42_multi Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749801"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T00:42:54.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 formGetRebootTimer stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2192",
        "datePublished": "2026-02-08T23:02:07.463Z",
        "dateReserved": "2026-02-07T17:28:28.567Z",
        "dateUpdated": "2026-02-23T09:51:06.600Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2191 (GCVE-0-2026-2191)

    Vulnerability from nvd – Published: 2026-02-08 22:32 – Updated: 2026-02-23 09:50
    VLAI
    Title
    Tenda AC9 formGetDdosDefenceList stack-based overflow
    Summary
    A weakness has been identified in Tenda AC9 15.03.06.42_multi. Affected is the function formGetDdosDefenceList. This manipulation of the argument security.ddos.map causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344894 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344894 signaturepermissions-required
    https://vuldb.com/?submit.749800 third-party-advisory
    https://github.com/glkfc/IoT-Vulnerability/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.06.42_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jfkk (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2191",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T20:59:03.732671Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T20:59:17.181Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.42_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jfkk (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda AC9 15.03.06.42_multi. Affected is the function formGetDdosDefenceList. This manipulation of the argument security.ddos.map causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:50:50.691Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344894 | Tenda AC9 formGetDdosDefenceList stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344894"
            },
            {
              "name": "VDB-344894 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344894"
            },
            {
              "name": "Submit #749800 | Tenda AC9 v1.0/V3.0 V15.03.06.42_multi Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749800"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda3.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T00:42:54.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 formGetDdosDefenceList stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2191",
        "datePublished": "2026-02-08T22:32:10.488Z",
        "dateReserved": "2026-02-07T17:28:24.242Z",
        "dateUpdated": "2026-02-23T09:50:50.691Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-57638 (GCVE-0-2025-57638)

    Vulnerability from nvd – Published: 2025-09-23 00:00 – Updated: 2025-09-24 18:38
    VLAI
    Summary
    Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57638",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T18:37:49.656599Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-122",
                    "description": "CWE-122 Heap-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T18:38:16.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-23T18:32:36.762Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-57638",
        "datePublished": "2025-09-23T00:00:00.000Z",
        "dateReserved": "2025-08-17T00:00:00.000Z",
        "dateUpdated": "2025-09-24T18:38:16.070Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57639 (GCVE-0-2025-57639)

    Vulnerability from nvd – Published: 2025-09-23 00:00 – Updated: 2025-09-24 18:36
    VLAI
    Summary
    OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57639",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T18:35:34.931603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T18:36:02.906Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-23T17:54:34.568Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda2.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-57639",
        "datePublished": "2025-09-23T00:00:00.000Z",
        "dateReserved": "2025-08-17T00:00:00.000Z",
        "dateUpdated": "2025-09-24T18:36:02.906Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10443 (GCVE-0-2025-10443)

    Vulnerability from nvd – Published: 2025-09-15 11:32 – Updated: 2025-09-15 11:40
    VLAI
    Title
    Tenda AC9/AC15 exeCommand formexeCommand buffer overflow
    Summary
    A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
    Affected: 15.03.05.18
    Create a notification for this product.
    Tenda AC15 Affected: 15.03.05.14
    Affected: 15.03.05.18
    Create a notification for this product.
    Credits
    shiny (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10443",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-15T11:40:27.372112Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-15T11:40:44.495Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                },
                {
                  "status": "affected",
                  "version": "15.03.05.18"
                }
              ]
            },
            {
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                },
                {
                  "status": "affected",
                  "version": "15.03.05.18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "shiny (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda AC9 and AC15 15.03.05.14/15.03.05.18 entdeckt. Dabei betrifft es die Funktion formexeCommand der Datei /goform/exeCommand. Dank Manipulation des Arguments cmdinput mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-15T11:32:07.435Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-323877 | Tenda AC9/AC15 exeCommand formexeCommand buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.323877"
            },
            {
              "name": "VDB-323877 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.323877"
            },
            {
              "name": "Submit #647840 | Tenda Tenda AC15\u3001AC9 AC15 V1.0BR_V15.03.05.18  AC9 V1.0BR_V15.03.05.14 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.647840"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-09-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-09-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-09-14T17:47:30.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9/AC15 exeCommand formexeCommand buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-10443",
        "datePublished": "2025-09-15T11:32:07.435Z",
        "dateReserved": "2025-09-14T15:42:18.331Z",
        "dateUpdated": "2025-09-15T11:40:44.495Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10442 (GCVE-0-2025-10442)

    Vulnerability from nvd – Published: 2025-09-15 11:02 – Updated: 2025-09-15 11:59
    VLAI
    Title
    Tenda AC9/AC15 exeCommand formexeCommand os command injection
    Summary
    A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
    Create a notification for this product.
    Tenda AC15 Affected: 15.03.05.14
    Create a notification for this product.
    Credits
    shiny (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10442",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-15T11:58:44.891161Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-15T11:59:00.751Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            },
            {
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "shiny (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC9 and AC15 15.03.05.14 gefunden. Dies betrifft die Funktion formexeCommand der Datei /goform/exeCommand. Dank der Manipulation des Arguments cmdinput mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-15T11:02:06.735Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-323876 | Tenda AC9/AC15 exeCommand formexeCommand os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.323876"
            },
            {
              "name": "VDB-323876 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.323876"
            },
            {
              "name": "Submit #647838 | Tenda Tenda AC9 V1.0BR_V15.03.05.14 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.647838"
            },
            {
              "name": "Submit #647839 | Tenda Tenda AC15 V1.0BR_V15.03.05.18 OS Command Injection (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.647839"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-09-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-09-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-09-14T17:46:07.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9/AC15 exeCommand formexeCommand os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-10442",
        "datePublished": "2025-09-15T11:02:06.735Z",
        "dateReserved": "2025-09-14T15:40:13.804Z",
        "dateUpdated": "2025-09-15T11:59:00.751Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9731 (GCVE-0-2025-9731)

    Vulnerability from nvd – Published: 2025-08-31 13:32 – Updated: 2025-09-02 15:14
    VLAI
    Title
    Tenda AC9 Administrative shadow hard-coded credentials
    Summary
    A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Hard-coded Credentials
    • CWE-259 - Use of Hard-coded Password
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.19
    Create a notification for this product.
    Credits
    Yu_Bao (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9731",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-02T14:40:47.599793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-02T15:14:30.872Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Administrative Interface"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Yu_Bao (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack\u0027s complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized."
            },
            {
              "lang": "de",
              "value": "In Tenda AC9 15.03.05.19 wurde eine Schwachstelle gefunden. Dies betrifft einen unbekannten Teil der Datei /etc_ro/shadow der Komponente Administrative Interface. Durch Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff ist nur lokal m\u00f6glich. Ein Angriff erfordert eine vergleichsweise hohe Komplexit\u00e4t. Die Ausnutzbarkeit gilt als schwierig. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 2,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 2.5,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 2.5,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 1,
                "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-31T13:32:07.821Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-322022 | Tenda AC9 Administrative shadow hard-coded credentials",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.322022"
            },
            {
              "name": "VDB-322022 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.322022"
            },
            {
              "name": "Submit #639748 | Tenda AC9 V15.03.05.19 Hard-coded Credentials",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.639748"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-30T16:03:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Administrative shadow hard-coded credentials"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9731",
        "datePublished": "2025-08-31T13:32:07.821Z",
        "dateReserved": "2025-08-30T13:58:00.879Z",
        "dateUpdated": "2025-09-02T15:14:30.872Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5900 (GCVE-0-2025-5900)

    Vulnerability from nvd – Published: 2025-06-09 22:00 – Updated: 2025-06-10 15:29
    VLAI
    Title
    Tenda AC9 cross-site request forgery
    Summary
    A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-352 - Cross-Site Request Forgery
    • CWE-862 - Missing Authorization
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysn0121 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5900",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-10T14:21:05.917336Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-10T15:29:00.898Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn0121 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine problematische Schwachstelle in Tenda AC9 15.03.02.13 gefunden. Dabei betrifft es einen unbekannter Codeteil. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-09T22:00:19.518Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311673 | Tenda AC9 cross-site request forgery",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.311673"
            },
            {
              "name": "VDB-311673 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311673"
            },
            {
              "name": "Submit #592198 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.592198"
            },
            {
              "name": "Submit #592199 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.592199"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolReboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-09T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-09T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-09T09:47:36.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 cross-site request forgery"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5900",
        "datePublished": "2025-06-09T22:00:19.518Z",
        "dateReserved": "2025-06-09T07:42:33.564Z",
        "dateUpdated": "2025-06-10T15:29:00.898Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5847 (GCVE-0-2025-5847)

    Vulnerability from nvd – Published: 2025-06-08 13:31 – Updated: 2025-06-09 13:54
    VLAI
    Title
    Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.311593 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.311593 signaturepermissions-required
    https://vuldb.com/?submit.591362 third-party-advisory
    https://candle-throne-f75.notion.site/Tenda-AC9-f… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysnysn (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5847",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T13:53:24.790033Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T13:54:42.018Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda AC9 15.03.02.13 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetSafeWanWebMan der Datei /goform/SetRemoteWebCfg der Komponente HTTP POST Request Handler. Durch das Manipulieren des Arguments remoteIp mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-08T13:32:05.147Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311593 | Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311593"
            },
            {
              "name": "VDB-311593 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311593"
            },
            {
              "name": "Submit #591362 | Tenda AC9 V1.0 V15.03.02.13 stack overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591362"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetSafeWanWebMan-20adf0aa118580a29e80cef9109c947a"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-08T11:27:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5847",
        "datePublished": "2025-06-08T13:31:44.996Z",
        "dateReserved": "2025-06-08T09:22:34.441Z",
        "dateUpdated": "2025-06-09T13:54:42.018Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5839 (GCVE-0-2025-5839)

    Vulnerability from nvd – Published: 2025-06-07 17:31 – Updated: 2025-06-09 03:34
    VLAI
    Title
    Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.311582 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.311582 signaturepermissions-required
    https://vuldb.com/?submit.591369 third-party-advisory
    https://candle-throne-f75.notion.site/Tenda-AC9-f… exploit
    https://www.tenda.com.cn/ broken-linkproduct
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysn0121 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5839",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T03:34:33.186014Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T03:34:50.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn0121 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Tenda AC9 15.03.02.13 entdeckt. Dies betrifft die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip der Komponente POST Request Handler. Durch das Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-07T17:31:13.113Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311582 | Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311582"
            },
            {
              "name": "VDB-311582 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311582"
            },
            {
              "name": "Submit #591369 | Tenda AC9 V1.0 V15.03.02.13 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591369"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
            },
            {
              "tags": [
                "broken-link",
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-06T22:21:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5839",
        "datePublished": "2025-06-07T17:31:13.113Z",
        "dateReserved": "2025-06-06T20:16:06.753Z",
        "dateUpdated": "2025-06-09T03:34:50.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5836 (GCVE-0-2025-5836)

    Vulnerability from nvd – Published: 2025-06-07 13:31 – Updated: 2025-06-09 15:06
    VLAI
    Title
    Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection
    Summary
    A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.311579 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.311579 signaturepermissions-required
    https://vuldb.com/?submit.591363 third-party-advisory
    https://candle-throne-f75.notion.site/Tenda-AC9-f… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysn (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5836",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T15:06:27.930039Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T15:06:31.883Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC9 15.03.02.13 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetIptv der Datei /goform/SetIPTVCfg der Komponente POST Request Handler. Durch Manipulation des Arguments list mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-07T13:31:06.620Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311579 | Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311579"
            },
            {
              "name": "VDB-311579 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311579"
            },
            {
              "name": "Submit #591363 | Tenda AC9 V1.0 V15.03.02.13 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591363"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-06T22:17:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5836",
        "datePublished": "2025-06-07T13:31:06.620Z",
        "dateReserved": "2025-06-06T20:11:59.450Z",
        "dateUpdated": "2025-06-09T15:06:31.883Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-45042 (GCVE-0-2025-45042)

    Vulnerability from nvd – Published: 2025-05-05 00:00 – Updated: 2025-05-05 15:56
    VLAI
    Summary
    Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-45042",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-05T15:55:27.853789Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-05T15:56:18.613Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-05T15:32:23.717Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-45042",
        "datePublished": "2025-05-05T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-05T15:56:18.613Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-44877 (GCVE-0-2025-44877)

    Vulnerability from nvd – Published: 2025-05-02 00:00 – Updated: 2025-05-06 15:16
    VLAI
    Summary
    Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44877",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-06T15:16:10.418505Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-06T15:16:43.764Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formSetSambaConf"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-02T14:35:48.519Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formSetSambaConf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44877",
        "datePublished": "2025-05-02T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-06T15:16:43.764Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-44872 (GCVE-0-2025-44872)

    Vulnerability from nvd – Published: 2025-05-02 00:00 – Updated: 2025-05-06 15:17
    VLAI
    Summary
    Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44872",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-06T15:17:17.673448Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-06T15:17:45.827Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formsetUsbUnload"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-02T14:39:25.635Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formsetUsbUnload"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44872",
        "datePublished": "2025-05-02T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-06T15:17:45.827Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-6016 (GCVE-0-2026-6016)

    Vulnerability from cvelistv5 – Published: 2026-04-10 05:00 – Updated: 2026-04-10 13:40
    VLAI
    Title
    Tenda AC9 POST Request WizardHandle decodePwd stack-based overflow
    Summary
    A vulnerability was found in Tenda AC9 15.03.02.13. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Performing a manipulation of the argument WANS results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wxhwxhwxh_mie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6016",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-10T13:39:55.830180Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-10T13:40:04.879Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC9 15.03.02.13. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Performing a manipulation of the argument WANS results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-10T05:00:23.163Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-356572 | Tenda AC9 POST Request WizardHandle decodePwd stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/356572"
            },
            {
              "name": "VDB-356572 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/356572/cti"
            },
            {
              "name": "Submit #791829 | Tenda AC9 AC9 V1.0 V15.03.02.13 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/791829"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC9-WizardHandle-33153a41781f808480f9e3b78ce438e0?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-09T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-09T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-09T16:43:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request WizardHandle decodePwd stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6016",
        "datePublished": "2026-04-10T05:00:23.163Z",
        "dateReserved": "2026-04-09T14:38:10.228Z",
        "dateUpdated": "2026-04-10T13:40:04.879Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-6015 (GCVE-0-2026-6015)

    Vulnerability from cvelistv5 – Published: 2026-04-10 04:45 – Updated: 2026-04-14 14:34
    VLAI
    Title
    Tenda AC9 POST Request QuickIndex formQuickIndex stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC9 15.03.02.13. Impacted is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. Such manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    wxhwxhwxh_mie (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6015",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-14T14:33:59.437612Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-14T14:34:24.148Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC9 15.03.02.13. Impacted is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. Such manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-10T04:45:15.605Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-356571 | Tenda AC9 POST Request QuickIndex formQuickIndex stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/356571"
            },
            {
              "name": "VDB-356571 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/356571/cti"
            },
            {
              "name": "Submit #791828 | Tenda AC9 AC9 V1.0 V15.03.02.13 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/791828"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC9-QuickIndex-33153a41781f80458940f212f150a4fb?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-09T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-09T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-09T16:43:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request QuickIndex formQuickIndex stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6015",
        "datePublished": "2026-04-10T04:45:15.605Z",
        "dateReserved": "2026-04-09T14:36:50.168Z",
        "dateUpdated": "2026-04-14T14:34:24.148Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2192 (GCVE-0-2026-2192)

    Vulnerability from cvelistv5 – Published: 2026-02-08 23:02 – Updated: 2026-02-23 09:51
    VLAI
    Title
    Tenda AC9 formGetRebootTimer stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda AC9 15.03.06.42_multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.start_time/sys.schedulereboot.end_time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344895 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344895 signaturepermissions-required
    https://vuldb.com/?submit.749801 third-party-advisory
    https://github.com/glkfc/IoT-Vulnerability/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.06.42_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jfkk (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2192",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T16:44:38.803800Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T16:45:07.148Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.42_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jfkk (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda AC9 15.03.06.42_multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.start_time/sys.schedulereboot.end_time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:51:06.600Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344895 | Tenda AC9 formGetRebootTimer stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344895"
            },
            {
              "name": "VDB-344895 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344895"
            },
            {
              "name": "Submit #749801 | Tenda AC9 v1.0/V3.0 V15.03.06.42_multi Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749801"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T00:42:54.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 formGetRebootTimer stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2192",
        "datePublished": "2026-02-08T23:02:07.463Z",
        "dateReserved": "2026-02-07T17:28:28.567Z",
        "dateUpdated": "2026-02-23T09:51:06.600Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2191 (GCVE-0-2026-2191)

    Vulnerability from cvelistv5 – Published: 2026-02-08 22:32 – Updated: 2026-02-23 09:50
    VLAI
    Title
    Tenda AC9 formGetDdosDefenceList stack-based overflow
    Summary
    A weakness has been identified in Tenda AC9 15.03.06.42_multi. Affected is the function formGetDdosDefenceList. This manipulation of the argument security.ddos.map causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344894 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344894 signaturepermissions-required
    https://vuldb.com/?submit.749800 third-party-advisory
    https://github.com/glkfc/IoT-Vulnerability/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.06.42_multi
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jfkk (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2191",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T20:59:03.732671Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T20:59:17.181Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.42_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jfkk (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda AC9 15.03.06.42_multi. Affected is the function formGetDdosDefenceList. This manipulation of the argument security.ddos.map causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:50:50.691Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344894 | Tenda AC9 formGetDdosDefenceList stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344894"
            },
            {
              "name": "VDB-344894 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344894"
            },
            {
              "name": "Submit #749800 | Tenda AC9 v1.0/V3.0 V15.03.06.42_multi Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749800"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda3.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T00:42:54.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 formGetDdosDefenceList stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2191",
        "datePublished": "2026-02-08T22:32:10.488Z",
        "dateReserved": "2026-02-07T17:28:24.242Z",
        "dateUpdated": "2026-02-23T09:50:50.691Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-57638 (GCVE-0-2025-57638)

    Vulnerability from cvelistv5 – Published: 2025-09-23 00:00 – Updated: 2025-09-24 18:38
    VLAI
    Summary
    Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57638",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T18:37:49.656599Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-122",
                    "description": "CWE-122 Heap-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T18:38:16.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-23T18:32:36.762Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda1.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-57638",
        "datePublished": "2025-09-23T00:00:00.000Z",
        "dateReserved": "2025-08-17T00:00:00.000Z",
        "dateUpdated": "2025-09-24T18:38:16.070Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57639 (GCVE-0-2025-57639)

    Vulnerability from cvelistv5 – Published: 2025-09-23 00:00 – Updated: 2025-09-24 18:36
    VLAI
    Summary
    OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57639",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T18:35:34.931603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T18:36:02.906Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-23T17:54:34.568Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/Tenda/tenda2.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-57639",
        "datePublished": "2025-09-23T00:00:00.000Z",
        "dateReserved": "2025-08-17T00:00:00.000Z",
        "dateUpdated": "2025-09-24T18:36:02.906Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10443 (GCVE-0-2025-10443)

    Vulnerability from cvelistv5 – Published: 2025-09-15 11:32 – Updated: 2025-09-15 11:40
    VLAI
    Title
    Tenda AC9/AC15 exeCommand formexeCommand buffer overflow
    Summary
    A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
    Affected: 15.03.05.18
    Create a notification for this product.
    Tenda AC15 Affected: 15.03.05.14
    Affected: 15.03.05.18
    Create a notification for this product.
    Credits
    shiny (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10443",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-15T11:40:27.372112Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-15T11:40:44.495Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                },
                {
                  "status": "affected",
                  "version": "15.03.05.18"
                }
              ]
            },
            {
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                },
                {
                  "status": "affected",
                  "version": "15.03.05.18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "shiny (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC9 and AC15 15.03.05.14/15.03.05.18. This vulnerability affects the function formexeCommand of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda AC9 and AC15 15.03.05.14/15.03.05.18 entdeckt. Dabei betrifft es die Funktion formexeCommand der Datei /goform/exeCommand. Dank Manipulation des Arguments cmdinput mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-15T11:32:07.435Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-323877 | Tenda AC9/AC15 exeCommand formexeCommand buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.323877"
            },
            {
              "name": "VDB-323877 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.323877"
            },
            {
              "name": "Submit #647840 | Tenda Tenda AC15\u3001AC9 AC15 V1.0BR_V15.03.05.18  AC9 V1.0BR_V15.03.05.14 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.647840"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC15_AC9_Bof.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-09-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-09-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-09-14T17:47:30.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9/AC15 exeCommand formexeCommand buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-10443",
        "datePublished": "2025-09-15T11:32:07.435Z",
        "dateReserved": "2025-09-14T15:42:18.331Z",
        "dateUpdated": "2025-09-15T11:40:44.495Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10442 (GCVE-0-2025-10442)

    Vulnerability from cvelistv5 – Published: 2025-09-15 11:02 – Updated: 2025-09-15 11:59
    VLAI
    Title
    Tenda AC9/AC15 exeCommand formexeCommand os command injection
    Summary
    A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.14
    Create a notification for this product.
    Tenda AC15 Affected: 15.03.05.14
    Create a notification for this product.
    Credits
    shiny (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10442",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-15T11:58:44.891161Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-15T11:59:00.751Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            },
            {
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.14"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "shiny (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC9 and AC15 15.03.05.14 gefunden. Dies betrifft die Funktion formexeCommand der Datei /goform/exeCommand. Dank der Manipulation des Arguments cmdinput mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-15T11:02:06.735Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-323876 | Tenda AC9/AC15 exeCommand formexeCommand os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.323876"
            },
            {
              "name": "VDB-323876 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.323876"
            },
            {
              "name": "Submit #647838 | Tenda Tenda AC9 V1.0BR_V15.03.05.14 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.647838"
            },
            {
              "name": "Submit #647839 | Tenda Tenda AC15 V1.0BR_V15.03.05.18 OS Command Injection (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.647839"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/2664521593/mycve/blob/main/Tenda/Tenda_AC9_CJ.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-09-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-09-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-09-14T17:46:07.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9/AC15 exeCommand formexeCommand os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-10442",
        "datePublished": "2025-09-15T11:02:06.735Z",
        "dateReserved": "2025-09-14T15:40:13.804Z",
        "dateUpdated": "2025-09-15T11:59:00.751Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9731 (GCVE-0-2025-9731)

    Vulnerability from cvelistv5 – Published: 2025-08-31 13:32 – Updated: 2025-09-02 15:14
    VLAI
    Title
    Tenda AC9 Administrative shadow hard-coded credentials
    Summary
    A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Hard-coded Credentials
    • CWE-259 - Use of Hard-coded Password
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.05.19
    Create a notification for this product.
    Credits
    Yu_Bao (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9731",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-02T14:40:47.599793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-02T15:14:30.872Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Administrative Interface"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Yu_Bao (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack\u0027s complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized."
            },
            {
              "lang": "de",
              "value": "In Tenda AC9 15.03.05.19 wurde eine Schwachstelle gefunden. Dies betrifft einen unbekannten Teil der Datei /etc_ro/shadow der Komponente Administrative Interface. Durch Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff ist nur lokal m\u00f6glich. Ein Angriff erfordert eine vergleichsweise hohe Komplexit\u00e4t. Die Ausnutzbarkeit gilt als schwierig. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 2,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 2.5,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 2.5,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 1,
                "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-31T13:32:07.821Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-322022 | Tenda AC9 Administrative shadow hard-coded credentials",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.322022"
            },
            {
              "name": "VDB-322022 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.322022"
            },
            {
              "name": "Submit #639748 | Tenda AC9 V15.03.05.19 Hard-coded Credentials",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.639748"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-30T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-30T16:03:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 Administrative shadow hard-coded credentials"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9731",
        "datePublished": "2025-08-31T13:32:07.821Z",
        "dateReserved": "2025-08-30T13:58:00.879Z",
        "dateUpdated": "2025-09-02T15:14:30.872Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5900 (GCVE-0-2025-5900)

    Vulnerability from cvelistv5 – Published: 2025-06-09 22:00 – Updated: 2025-06-10 15:29
    VLAI
    Title
    Tenda AC9 cross-site request forgery
    Summary
    A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-352 - Cross-Site Request Forgery
    • CWE-862 - Missing Authorization
    Assigner
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysn0121 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5900",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-10T14:21:05.917336Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-10T15:29:00.898Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn0121 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine problematische Schwachstelle in Tenda AC9 15.03.02.13 gefunden. Dabei betrifft es einen unbekannter Codeteil. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-09T22:00:19.518Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311673 | Tenda AC9 cross-site request forgery",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.311673"
            },
            {
              "name": "VDB-311673 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311673"
            },
            {
              "name": "Submit #592198 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.592198"
            },
            {
              "name": "Submit #592199 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.592199"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolReboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-09T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-09T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-09T09:47:36.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 cross-site request forgery"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5900",
        "datePublished": "2025-06-09T22:00:19.518Z",
        "dateReserved": "2025-06-09T07:42:33.564Z",
        "dateUpdated": "2025-06-10T15:29:00.898Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5847 (GCVE-0-2025-5847)

    Vulnerability from cvelistv5 – Published: 2025-06-08 13:31 – Updated: 2025-06-09 13:54
    VLAI
    Title
    Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.311593 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.311593 signaturepermissions-required
    https://vuldb.com/?submit.591362 third-party-advisory
    https://candle-throne-f75.notion.site/Tenda-AC9-f… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysnysn (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5847",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T13:53:24.790033Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T13:54:42.018Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda AC9 15.03.02.13 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetSafeWanWebMan der Datei /goform/SetRemoteWebCfg der Komponente HTTP POST Request Handler. Durch das Manipulieren des Arguments remoteIp mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-08T13:32:05.147Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311593 | Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311593"
            },
            {
              "name": "VDB-311593 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311593"
            },
            {
              "name": "Submit #591362 | Tenda AC9 V1.0 V15.03.02.13 stack overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591362"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetSafeWanWebMan-20adf0aa118580a29e80cef9109c947a"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-08T11:27:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5847",
        "datePublished": "2025-06-08T13:31:44.996Z",
        "dateReserved": "2025-06-08T09:22:34.441Z",
        "dateUpdated": "2025-06-09T13:54:42.018Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5839 (GCVE-0-2025-5839)

    Vulnerability from cvelistv5 – Published: 2025-06-07 17:31 – Updated: 2025-06-09 03:34
    VLAI
    Title
    Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.311582 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.311582 signaturepermissions-required
    https://vuldb.com/?submit.591369 third-party-advisory
    https://candle-throne-f75.notion.site/Tenda-AC9-f… exploit
    https://www.tenda.com.cn/ broken-linkproduct
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysn0121 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5839",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T03:34:33.186014Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T03:34:50.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn0121 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Tenda AC9 15.03.02.13 entdeckt. Dies betrifft die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip der Komponente POST Request Handler. Durch das Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-07T17:31:13.113Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311582 | Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311582"
            },
            {
              "name": "VDB-311582 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311582"
            },
            {
              "name": "Submit #591369 | Tenda AC9 V1.0 V15.03.02.13 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591369"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
            },
            {
              "tags": [
                "broken-link",
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-06T22:21:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5839",
        "datePublished": "2025-06-07T17:31:13.113Z",
        "dateReserved": "2025-06-06T20:16:06.753Z",
        "dateUpdated": "2025-06-09T03:34:50.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5836 (GCVE-0-2025-5836)

    Vulnerability from cvelistv5 – Published: 2025-06-07 13:31 – Updated: 2025-06-09 15:06
    VLAI
    Title
    Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection
    Summary
    A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.311579 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.311579 signaturepermissions-required
    https://vuldb.com/?submit.591363 third-party-advisory
    https://candle-throne-f75.notion.site/Tenda-AC9-f… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC9 Affected: 15.03.02.13
    Create a notification for this product.
    Credits
    ysnysn (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5836",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T15:06:27.930039Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T15:06:31.883Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.02.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ysnysn (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC9 15.03.02.13 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetIptv der Datei /goform/SetIPTVCfg der Komponente POST Request Handler. Durch Manipulation des Arguments list mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-07T13:31:06.620Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311579 | Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311579"
            },
            {
              "name": "VDB-311579 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311579"
            },
            {
              "name": "Submit #591363 | Tenda AC9 V1.0 V15.03.02.13 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591363"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-06T22:17:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5836",
        "datePublished": "2025-06-07T13:31:06.620Z",
        "dateReserved": "2025-06-06T20:11:59.450Z",
        "dateUpdated": "2025-06-09T15:06:31.883Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-45042 (GCVE-0-2025-45042)

    Vulnerability from cvelistv5 – Published: 2025-05-05 00:00 – Updated: 2025-05-05 15:56
    VLAI
    Summary
    Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-45042",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-05T15:55:27.853789Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-05T15:56:18.613Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-05T15:32:23.717Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-45042",
        "datePublished": "2025-05-05T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-05T15:56:18.613Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }