Search

Find a vulnerability

Search criteria

    22 vulnerabilities found for a18_firmware by tenda

    CVE-2026-2930 (GCVE-0-2026-2930)

    Vulnerability from nvd – Published: 2026-02-22 06:02 – Updated: 2026-02-27 18:14
    VLAI
    Title
    Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow
    Summary
    A vulnerability was identified in Tenda A18 15.13.07.13. The affected element is the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. Such manipulation of the argument boundary leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.347277 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347277 signaturepermissions-required
    https://vuldb.com/?submit.755227 third-party-advisory
    https://github.com/master-abc/cve/issues/40 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.13
    Create a notification for this product.
    Credits
    Liyu Zhu (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2930",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-27T18:14:40.511631Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-27T18:14:49.138Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Httpd Service"
              ],
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Liyu Zhu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda A18 15.13.07.13. The affected element is the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. Such manipulation of the argument boundary leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T06:02:10.062Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347277 | Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347277"
            },
            {
              "name": "VDB-347277 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347277"
            },
            {
              "name": "Submit #755227 | Tenda A18 V15.13.07.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755227"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/master-abc/cve/issues/40"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-21T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-21T06:05:35.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2930",
        "datePublished": "2026-02-22T06:02:10.062Z",
        "dateReserved": "2026-02-21T05:00:32.389Z",
        "dateUpdated": "2026-02-27T18:14:49.138Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2877 (GCVE-0-2026-2877)

    Vulnerability from nvd – Published: 2026-02-21 18:32 – Updated: 2026-02-23 15:40
    VLAI
    Title
    Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow
    Summary
    A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.347130 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347130 signaturepermissions-required
    https://vuldb.com/?submit.754703 third-party-advisory
    https://github.com/master-abc/cve/issues/39 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.13
    Create a notification for this product.
    Credits
    942384053 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2877",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T15:39:52.225788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T15:40:18.876Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Httpd Service"
              ],
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "942384053 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-21T18:32:08.125Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347130 | Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347130"
            },
            {
              "name": "VDB-347130 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347130"
            },
            {
              "name": "Submit #754703 | Tenda A18 V15.13.07.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.754703"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/master-abc/cve/issues/39"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T17:18:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2877",
        "datePublished": "2026-02-21T18:32:08.125Z",
        "dateReserved": "2026-02-20T16:13:16.150Z",
        "dateUpdated": "2026-02-23T15:40:18.876Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2876 (GCVE-0-2026-2876)

    Vulnerability from nvd – Published: 2026-02-21 17:32 – Updated: 2026-02-23 15:41
    VLAI
    Title
    Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow
    Summary
    A vulnerability was determined in Tenda A18 15.13.07.13. This affects the function parse_macfilter_rule of the file /goform/setBlackRule. This manipulation of the argument deviceList causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.347114 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347114 signaturepermissions-required
    https://vuldb.com/?submit.754675 third-party-advisory
    https://github.com/master-abc/cve/issues/38 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.13
    Create a notification for this product.
    Credits
    junqi (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2876",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T15:40:57.907138Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T15:41:12.127Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "junqi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda A18 15.13.07.13. This affects the function parse_macfilter_rule of the file /goform/setBlackRule. This manipulation of the argument deviceList causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-21T17:32:11.364Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347114 | Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347114"
            },
            {
              "name": "VDB-347114 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347114"
            },
            {
              "name": "Submit #754675 | Tenda A18 V15.13.07.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.754675"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/master-abc/cve/issues/38"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T17:10:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2876",
        "datePublished": "2026-02-21T17:32:11.364Z",
        "dateReserved": "2026-02-20T16:05:23.156Z",
        "dateUpdated": "2026-02-23T15:41:12.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-0848 (GCVE-0-2025-0848)

    Vulnerability from nvd – Published: 2025-01-30 01:00 – Updated: 2025-01-30 15:12
    VLAI
    Title
    Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow
    Summary
    A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.294011 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.294011 signaturepermissions-required
    https://vuldb.com/?submit.485802 third-party-advisory
    https://github.com/alc9700jmo/CVE/issues/9 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.09
    Create a notification for this product.
    Credits
    alc9700 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-0848",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-30T15:12:54.599269Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-30T15:12:59.662Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.09"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "alc9700 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda A18 bis 15.13.07.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion SetCmdlineRun der Datei /goform/SetCmdlineRun der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-30T01:00:19.576Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-294011 | Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.294011"
            },
            {
              "name": "VDB-294011 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.294011"
            },
            {
              "name": "Submit #485802 | Tenda Tenda A18 V15.13.07.09 V15.13.07.09 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.485802"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/alc9700jmo/CVE/issues/9"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-01-29T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-01-29T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-01-29T18:14:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-0848",
        "datePublished": "2025-01-30T01:00:19.576Z",
        "dateReserved": "2025-01-29T17:09:28.802Z",
        "dateUpdated": "2025-01-30T15:12:59.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32305 (GCVE-0-2024-32305)

    Vulnerability from nvd – Published: 2024-04-17 00:00 – Updated: 2024-11-06 15:34
    VLAI
    Summary
    Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18_firmware Affected: 15.03.05.05
        cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.05"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32305",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-06T15:34:21.018925Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-06T15:34:24.417Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:06:44.205Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-17T15:40:16.012Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-32305",
        "datePublished": "2024-04-17T00:00:00.000Z",
        "dateReserved": "2024-04-12T00:00:00.000Z",
        "dateUpdated": "2024-11-06T15:34:24.417Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-50585 (GCVE-0-2023-50585)

    Vulnerability from nvd – Published: 2024-01-09 00:00 – Updated: 2025-06-03 14:34
    VLAI
    Summary
    Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:16:47.203Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-50585",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-08T16:00:01.273922Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T14:34:10.536Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T08:13:03.708Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-50585",
        "datePublished": "2024-01-09T00:00:00.000Z",
        "dateReserved": "2023-12-11T00:00:00.000Z",
        "dateUpdated": "2025-06-03T14:34:10.536Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-39829 (GCVE-0-2023-39829)

    Vulnerability from nvd – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:06
    VLAI
    Summary
    Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18 Affected: v15.13.07.09
        cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:18:09.781Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v15.13.07.09"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-39829",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-09T15:05:51.396837Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-09T15:06:32.724Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-14T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-39829",
        "datePublished": "2023-08-14T00:00:00.000Z",
        "dateReserved": "2023-08-07T00:00:00.000Z",
        "dateUpdated": "2024-10-09T15:06:32.724Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-39828 (GCVE-0-2023-39828)

    Vulnerability from nvd – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:07
    VLAI
    Summary
    Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18 Affected: v15.13.07.09
        cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:18:10.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v15.13.07.09"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-39828",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-09T15:07:04.245313Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-09T15:07:39.636Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-14T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-39828",
        "datePublished": "2023-08-14T00:00:00.000Z",
        "dateReserved": "2023-08-07T00:00:00.000Z",
        "dateUpdated": "2024-10-09T15:07:39.636Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-39827 (GCVE-0-2023-39827)

    Vulnerability from nvd – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:51
    VLAI
    Summary
    Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18 Affected: V15.13.07.09
        cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:18:09.831Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "V15.13.07.09"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-39827",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-09T15:50:21.641738Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-09T15:51:41.730Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-14T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-39827",
        "datePublished": "2023-08-14T00:00:00.000Z",
        "dateReserved": "2023-08-07T00:00:00.000Z",
        "dateUpdated": "2024-10-09T15:51:41.730Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-44932 (GCVE-0-2022-44932)

    Vulnerability from nvd – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:10
    VLAI
    Summary
    An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-284 - Improper Access Control
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.343Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-44932",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-23T15:09:49.893625Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-23T15:10:40.247Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-08T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-44932",
        "datePublished": "2022-12-08T00:00:00.000Z",
        "dateReserved": "2022-11-07T00:00:00.000Z",
        "dateUpdated": "2025-04-23T15:10:40.247Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-44931 (GCVE-0-2022-44931)

    Vulnerability from nvd – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:11
    VLAI
    Summary
    Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-44931",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-23T15:11:08.240199Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-23T15:11:13.068Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-08T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-44931",
        "datePublished": "2022-12-08T00:00:00.000Z",
        "dateReserved": "2022-11-07T00:00:00.000Z",
        "dateUpdated": "2025-04-23T15:11:13.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-2930 (GCVE-0-2026-2930)

    Vulnerability from cvelistv5 – Published: 2026-02-22 06:02 – Updated: 2026-02-27 18:14
    VLAI
    Title
    Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow
    Summary
    A vulnerability was identified in Tenda A18 15.13.07.13. The affected element is the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. Such manipulation of the argument boundary leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.347277 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347277 signaturepermissions-required
    https://vuldb.com/?submit.755227 third-party-advisory
    https://github.com/master-abc/cve/issues/40 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.13
    Create a notification for this product.
    Credits
    Liyu Zhu (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2930",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-27T18:14:40.511631Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-27T18:14:49.138Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Httpd Service"
              ],
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Liyu Zhu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda A18 15.13.07.13. The affected element is the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. Such manipulation of the argument boundary leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T06:02:10.062Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347277 | Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347277"
            },
            {
              "name": "VDB-347277 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347277"
            },
            {
              "name": "Submit #755227 | Tenda A18 V15.13.07.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755227"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/master-abc/cve/issues/40"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-21T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-21T06:05:35.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2930",
        "datePublished": "2026-02-22T06:02:10.062Z",
        "dateReserved": "2026-02-21T05:00:32.389Z",
        "dateUpdated": "2026-02-27T18:14:49.138Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2877 (GCVE-0-2026-2877)

    Vulnerability from cvelistv5 – Published: 2026-02-21 18:32 – Updated: 2026-02-23 15:40
    VLAI
    Title
    Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow
    Summary
    A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.347130 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347130 signaturepermissions-required
    https://vuldb.com/?submit.754703 third-party-advisory
    https://github.com/master-abc/cve/issues/39 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.13
    Create a notification for this product.
    Credits
    942384053 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2877",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T15:39:52.225788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T15:40:18.876Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Httpd Service"
              ],
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "942384053 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-21T18:32:08.125Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347130 | Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347130"
            },
            {
              "name": "VDB-347130 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347130"
            },
            {
              "name": "Submit #754703 | Tenda A18 V15.13.07.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.754703"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/master-abc/cve/issues/39"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T17:18:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2877",
        "datePublished": "2026-02-21T18:32:08.125Z",
        "dateReserved": "2026-02-20T16:13:16.150Z",
        "dateUpdated": "2026-02-23T15:40:18.876Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2876 (GCVE-0-2026-2876)

    Vulnerability from cvelistv5 – Published: 2026-02-21 17:32 – Updated: 2026-02-23 15:41
    VLAI
    Title
    Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow
    Summary
    A vulnerability was determined in Tenda A18 15.13.07.13. This affects the function parse_macfilter_rule of the file /goform/setBlackRule. This manipulation of the argument deviceList causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.347114 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347114 signaturepermissions-required
    https://vuldb.com/?submit.754675 third-party-advisory
    https://github.com/master-abc/cve/issues/38 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.13
    Create a notification for this product.
    Credits
    junqi (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2876",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T15:40:57.907138Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T15:41:12.127Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.13"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "junqi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda A18 15.13.07.13. This affects the function parse_macfilter_rule of the file /goform/setBlackRule. This manipulation of the argument deviceList causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-21T17:32:11.364Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347114 | Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347114"
            },
            {
              "name": "VDB-347114 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347114"
            },
            {
              "name": "Submit #754675 | Tenda A18 V15.13.07.13 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.754675"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/master-abc/cve/issues/38"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T17:10:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2876",
        "datePublished": "2026-02-21T17:32:11.364Z",
        "dateReserved": "2026-02-20T16:05:23.156Z",
        "dateUpdated": "2026-02-23T15:41:12.127Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-0848 (GCVE-0-2025-0848)

    Vulnerability from cvelistv5 – Published: 2025-01-30 01:00 – Updated: 2025-01-30 15:12
    VLAI
    Title
    Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow
    Summary
    A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.294011 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.294011 signaturepermissions-required
    https://vuldb.com/?submit.485802 third-party-advisory
    https://github.com/alc9700jmo/CVE/issues/9 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda A18 Affected: 15.13.07.09
    Create a notification for this product.
    Credits
    alc9700 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-0848",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-30T15:12:54.599269Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-30T15:12:59.662Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "A18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.13.07.09"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "alc9700 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda A18 bis 15.13.07.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion SetCmdlineRun der Datei /goform/SetCmdlineRun der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-30T01:00:19.576Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-294011 | Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.294011"
            },
            {
              "name": "VDB-294011 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.294011"
            },
            {
              "name": "Submit #485802 | Tenda Tenda A18 V15.13.07.09 V15.13.07.09 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.485802"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/alc9700jmo/CVE/issues/9"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-01-29T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-01-29T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-01-29T18:14:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-0848",
        "datePublished": "2025-01-30T01:00:19.576Z",
        "dateReserved": "2025-01-29T17:09:28.802Z",
        "dateUpdated": "2025-01-30T15:12:59.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32305 (GCVE-0-2024-32305)

    Vulnerability from cvelistv5 – Published: 2024-04-17 00:00 – Updated: 2024-11-06 15:34
    VLAI
    Summary
    Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18_firmware Affected: 15.03.05.05
        cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.05"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32305",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-06T15:34:21.018925Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-121",
                    "description": "CWE-121 Stack-based Buffer Overflow",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-06T15:34:24.417Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:06:44.205Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-17T15:40:16.012Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-32305",
        "datePublished": "2024-04-17T00:00:00.000Z",
        "dateReserved": "2024-04-12T00:00:00.000Z",
        "dateUpdated": "2024-11-06T15:34:24.417Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-50585 (GCVE-0-2023-50585)

    Vulnerability from cvelistv5 – Published: 2024-01-09 00:00 – Updated: 2025-06-03 14:34
    VLAI
    Summary
    Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:16:47.203Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-50585",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-08T16:00:01.273922Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T14:34:10.536Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T08:13:03.708Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-50585",
        "datePublished": "2024-01-09T00:00:00.000Z",
        "dateReserved": "2023-12-11T00:00:00.000Z",
        "dateUpdated": "2025-06-03T14:34:10.536Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-39827 (GCVE-0-2023-39827)

    Vulnerability from cvelistv5 – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:51
    VLAI
    Summary
    Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18 Affected: V15.13.07.09
        cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:18:09.831Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "V15.13.07.09"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-39827",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-09T15:50:21.641738Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-09T15:51:41.730Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-14T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-39827",
        "datePublished": "2023-08-14T00:00:00.000Z",
        "dateReserved": "2023-08-07T00:00:00.000Z",
        "dateUpdated": "2024-10-09T15:51:41.730Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-39828 (GCVE-0-2023-39828)

    Vulnerability from cvelistv5 – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:07
    VLAI
    Summary
    Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18 Affected: v15.13.07.09
        cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:18:10.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v15.13.07.09"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-39828",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-09T15:07:04.245313Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-09T15:07:39.636Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-14T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-39828",
        "datePublished": "2023-08-14T00:00:00.000Z",
        "dateReserved": "2023-08-07T00:00:00.000Z",
        "dateUpdated": "2024-10-09T15:07:39.636Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-39829 (GCVE-0-2023-39829)

    Vulnerability from cvelistv5 – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:06
    VLAI
    Summary
    Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
    Severity
    No CVSS data available.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    Assigner
    Impacted products
    Vendor Product Version
    tenda a18 Affected: v15.13.07.09
        cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:18:09.781Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "a18",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v15.13.07.09"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-39829",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-09T15:05:51.396837Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-09T15:06:32.724Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-14T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-39829",
        "datePublished": "2023-08-14T00:00:00.000Z",
        "dateReserved": "2023-08-07T00:00:00.000Z",
        "dateUpdated": "2024-10-09T15:06:32.724Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-44932 (GCVE-0-2022-44932)

    Vulnerability from cvelistv5 – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:10
    VLAI
    Summary
    An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-284 - Improper Access Control
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.343Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-44932",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-23T15:09:49.893625Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-23T15:10:40.247Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-08T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-44932",
        "datePublished": "2022-12-08T00:00:00.000Z",
        "dateReserved": "2022-11-07T00:00:00.000Z",
        "dateUpdated": "2025-04-23T15:10:40.247Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-44931 (GCVE-0-2022-44931)

    Vulnerability from cvelistv5 – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:11
    VLAI
    Summary
    Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-787 - Out-of-bounds Write
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-44931",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-23T15:11:08.240199Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-23T15:11:13.068Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-12-08T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-44931",
        "datePublished": "2022-12-08T00:00:00.000Z",
        "dateReserved": "2022-11-07T00:00:00.000Z",
        "dateUpdated": "2025-04-23T15:11:13.068Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }