Search criteria
45 vulnerabilities found for AC1206 by Tenda
CVE-2026-0581 (GCVE-0-2026-0581)
Vulnerability from nvd – Published: 2026-01-05 08:02 – Updated: 2026-01-05 21:12| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-0581",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-05T21:12:38.055555Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-05T21:12:48.557Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "2160288544 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC1206 15.03.06.23. Affected by this issue is the function formBehaviorManager of the file /goform/BehaviorManager of the component httpd. Executing a manipulation of the argument modulename/option/data/switch can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-05T08:02:08.449Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-339473 | Tenda AC1206 httpd BehaviorManager formBehaviorManager command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.339473"
},
{
"name": "VDB-339473 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.339473"
},
{
"name": "Submit #731193 | Tenda AC1206 AC1206V1.0RTL_V15.03.06.23 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.731193"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/ccc-iotsec/cve-/blob/Tenda/Tenda%20AC1206%E5%91%BD%E4%BB%A4%E6%B3%A8%E5%85%A5%E6%BC%8F%E6%B4%9E.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-04T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-04T07:54:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC1206 httpd BehaviorManager formBehaviorManager command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-0581",
"datePublished": "2026-01-05T08:02:08.449Z",
"dateReserved": "2026-01-04T06:49:02.040Z",
"dateUpdated": "2026-01-05T21:12:48.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-0581 (GCVE-0-2026-0581)
Vulnerability from cvelistv5 – Published: 2026-01-05 08:02 – Updated: 2026-01-05 21:12| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-0581",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-05T21:12:38.055555Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-05T21:12:48.557Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "2160288544 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC1206 15.03.06.23. Affected by this issue is the function formBehaviorManager of the file /goform/BehaviorManager of the component httpd. Executing a manipulation of the argument modulename/option/data/switch can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-05T08:02:08.449Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-339473 | Tenda AC1206 httpd BehaviorManager formBehaviorManager command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.339473"
},
{
"name": "VDB-339473 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.339473"
},
{
"name": "Submit #731193 | Tenda AC1206 AC1206V1.0RTL_V15.03.06.23 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.731193"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/ccc-iotsec/cve-/blob/Tenda/Tenda%20AC1206%E5%91%BD%E4%BB%A4%E6%B3%A8%E5%85%A5%E6%BC%8F%E6%B4%9E.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-04T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-04T07:54:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC1206 httpd BehaviorManager formBehaviorManager command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-0581",
"datePublished": "2026-01-05T08:02:08.449Z",
"dateReserved": "2026-01-04T06:49:02.040Z",
"dateUpdated": "2026-01-05T21:12:48.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
VAR-202509-1480
Vulnerability from variot - Updated: 2025-10-03 23:26A vulnerability was found in Tenda AC1206 15.03.06.23. This vulnerability affects the function check_param_changed of the file /goform/AdvSetMacMtuWa of the component HTTP Request Handler. Performing manipulation of the argument wanMTU results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used. of ac1206 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-1480",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"cve": "CVE-2025-10432",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2025-10432",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-014674",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-10432",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014674",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-10432",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014674",
"trust": 0.8,
"value": "Critical"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC1206 15.03.06.23. This vulnerability affects the function check_param_changed of the file /goform/AdvSetMacMtuWa of the component HTTP Request Handler. Performing manipulation of the argument wanMTU results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used. of ac1206 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-10432"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-10432",
"trust": 2.6
},
{
"db": "VULDB",
"id": "323866",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014674",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"id": "VAR-202509-1480",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.4465335
},
"last_update_date": "2025-10-03T23:26:53.366000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/m4st3ryi/iotvulpocs/blob/main/tenda/ac1206/fromadvsetmacmtuwan.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.323866"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.647527"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.323866"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-10432"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"date": "2025-09-15T08:15:34.897000",
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-30T08:01:00",
"db": "JVNDB",
"id": "JVNDB-2025-014674"
},
{
"date": "2025-09-20T02:53:14.723000",
"db": "NVD",
"id": "CVE-2025-10432"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014674"
}
],
"trust": 0.8
}
}
VAR-202508-2337
Vulnerability from variot - Updated: 2025-09-28 03:24A vulnerability was detected in Tenda AC1206 15.03.06.23. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used. Shenzhen Tenda Technology Co.,Ltd. of ac1206 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202508-2337",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"cve": "CVE-2025-9523",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2025-9523",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-014519",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-9523",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014519",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-9523",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014519",
"trust": 0.8,
"value": "Critical"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was detected in Tenda AC1206 15.03.06.23. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used. Shenzhen Tenda Technology Co.,Ltd. of ac1206 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-9523"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-9523",
"trust": 2.6
},
{
"db": "VULDB",
"id": "321541",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014519",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"id": "VAR-202508-2337",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.4465335
},
"last_update_date": "2025-09-28T03:24:15.960000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/xxricardo/iot-cve/blob/main/tenda/ac1206/ac1206v1.0rtl_v15.03.06.23.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.321541"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.634309"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.321541"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-9523"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"date": "2025-08-27T11:15:42.210000",
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-26T06:30:00",
"db": "JVNDB",
"id": "JVNDB-2025-014519"
},
{
"date": "2025-09-20T03:26:36.253000",
"db": "NVD",
"id": "CVE-2025-9523"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014519"
}
],
"trust": 0.8
}
}
VAR-202507-0544
Vulnerability from variot - Updated: 2025-07-29 23:26A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of ac1206 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the parameter deviceList in the file /goform/setMacFilterCfg to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-0544",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"cve": "CVE-2025-7544",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-7544",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-009110",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-16961",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-7544",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-009110",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-7544",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-009110",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-16961",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of ac1206 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the parameter deviceList in the file /goform/setMacFilterCfg to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-7544"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "CNVD",
"id": "CNVD-2025-16961"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-7544",
"trust": 3.2
},
{
"db": "VULDB",
"id": "316241",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-16961",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"id": "VAR-202507-0544",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
}
],
"trust": 1.0465335
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
}
]
},
"last_update_date": "2025-07-29T23:26:18.146000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formsetmacfiltercfg.md"
},
{
"trust": 1.8,
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formsetmacfiltercfg.md#poc"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.316241"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.614089"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-7544"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.316241"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"date": "2025-07-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"date": "2025-07-13T22:15:23.693000",
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-16961"
},
{
"date": "2025-07-17T05:05:00",
"db": "JVNDB",
"id": "JVNDB-2025-009110"
},
{
"date": "2025-07-16T14:36:53.967000",
"db": "NVD",
"id": "CVE-2025-7544"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-009110"
}
],
"trust": 0.8
}
}
VAR-202505-0113
Vulnerability from variot - Updated: 2025-05-17 23:11A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been declared as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm. The manipulation leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. of ac1206 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker can exploit this vulnerability to execute arbitrary code
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202505-0113",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "lte",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 and earlier"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "lte",
"trust": 0.6,
"vendor": "tenda",
"version": "\u003c=15.03.06.23"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"cve": "CVE-2025-4298",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-4298",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-004946",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-09667",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-4298",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-4298",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-004946",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-4298",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-4298",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-004946",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-09667",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been declared as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm. The manipulation leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. of ac1206 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker can exploit this vulnerability to execute arbitrary code",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-4298"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "CNVD",
"id": "CNVD-2025-09667"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-4298",
"trust": 3.2
},
{
"db": "VULDB",
"id": "307402",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09667",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"id": "VAR-202505-0113",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
}
],
"trust": 1.0465335
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
}
]
},
"last_update_date": "2025-05-17T23:11:40.547000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://vuldb.com/?id.307402"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.563557"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-4298"
},
{
"trust": 1.0,
"url": "https://github.com/ch13hh/tmp_store_cc/blob/main/ac1206/ac1206formsetcfm/formsetcfm.md"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.307402"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"date": "2025-05-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"date": "2025-05-06T00:15:15.620000",
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09667"
},
{
"date": "2025-05-14T12:41:00",
"db": "JVNDB",
"id": "JVNDB-2025-004946"
},
{
"date": "2025-05-13T20:06:19.080000",
"db": "NVD",
"id": "CVE-2025-4298"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-004946"
}
],
"trust": 0.8
}
}
VAR-202210-0726
Vulnerability from variot - Updated: 2025-05-17 04:02Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot. Shenzhen Tenda Technology Co.,Ltd. of ac1206 A cross-site request forgery vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. This vulnerability exists in the fromSysToolReboot function in the /bin/httpd file. Attackers can exploit the vulnerability to cause denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0726",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23_multi_td01"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 multi td01"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206 us ac1206v1.0rtl v15.03.06.23 multi td01",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"cve": "CVE-2022-42077",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-87935",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2022-42077",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-42077",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-42077",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-42077",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-42077",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2022-87935",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-729",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-729"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot. Shenzhen Tenda Technology Co.,Ltd. of ac1206 A cross-site request forgery vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. This vulnerability exists in the fromSysToolReboot function in the /bin/httpd file. Attackers can exploit the vulnerability to cause denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-42077"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "CNVD",
"id": "CNVD-2022-87935"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-42077",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-87935",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202210-729",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-729"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"id": "VAR-202210-0726",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
}
],
"trust": 1.3232667500000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
}
]
},
"last_update_date": "2025-05-17T04:02:03.496000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.0
},
{
"problemtype": "Cross-site request forgery (CWE-352) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://github.com/tianhui999/mycve/blob/main/ac1206/ac1206-1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-42077"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-42077/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-729"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-729"
},
{
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"date": "2023-10-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"date": "2022-10-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-729"
},
{
"date": "2022-10-12T19:15:09.570000",
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87935"
},
{
"date": "2023-10-20T06:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-018525"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-729"
},
{
"date": "2025-05-15T19:15:55.163000",
"db": "NVD",
"id": "CVE-2022-42077"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-729"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Cross-site request forgery vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018525"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-729"
}
],
"trust": 0.6
}
}
VAR-202210-0881
Vulnerability from variot - Updated: 2025-05-17 03:57Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via the function formWifiBasicSet. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. This vulnerability exists in the /bin/httpd file formWifiBasicSet function/goform/WifiBasicSet page. Attackers can exploit the vulnerability to cause denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0881",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23_multi_td01"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 multi td01"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206 us ac1206v1.0rtl v15.03.06.23 multi td01",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"cve": "CVE-2022-42079",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-87937",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-42079",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-42079",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-42079",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-42079",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-42079",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2022-87937",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-727",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-727"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via the function formWifiBasicSet. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. This vulnerability exists in the /bin/httpd file formWifiBasicSet function/goform/WifiBasicSet page. Attackers can exploit the vulnerability to cause denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-42079"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "CNVD",
"id": "CNVD-2022-87937"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-42079",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-87937",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202210-727",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-727"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"id": "VAR-202210-0881",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
}
],
"trust": 1.3232667500000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
}
]
},
"last_update_date": "2025-05-17T03:57:04.286000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://github.com/tianhui999/mycve/blob/main/ac1206/ac1206-3.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-42079"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-42079/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-727"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-727"
},
{
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"date": "2023-10-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"date": "2022-10-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-727"
},
{
"date": "2022-10-12T19:15:09.690000",
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87937"
},
{
"date": "2023-10-20T06:16:00",
"db": "JVNDB",
"id": "JVNDB-2022-018523"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-727"
},
{
"date": "2025-05-15T19:15:55.513000",
"db": "NVD",
"id": "CVE-2022-42079"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-727"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018523"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-727"
}
],
"trust": 0.6
}
}
VAR-202210-1256
Vulnerability from variot - Updated: 2025-05-17 03:50Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet. Shenzhen Tenda Technology Co.,Ltd. of ac1206 A cross-site request forgery vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. This vulnerability exists in the fromSysToolRestoreSet function/goform/SysToolRestoreSet page in the /bin/httpd file. Attackers can use the vulnerability to cause denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-1256",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23_multi_td01"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 multi td01"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206 us ac1206v1.0rtl v15.03.06.23 multi td01",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"cve": "CVE-2022-42078",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-87936",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2022-42078",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-42078",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-42078",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-42078",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-42078",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2022-87936",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-728",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-728"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet. Shenzhen Tenda Technology Co.,Ltd. of ac1206 A cross-site request forgery vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. This vulnerability exists in the fromSysToolRestoreSet function/goform/SysToolRestoreSet page in the /bin/httpd file. Attackers can use the vulnerability to cause denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-42078"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "CNVD",
"id": "CNVD-2022-87936"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-42078",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-87936",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202210-728",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-728"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"id": "VAR-202210-1256",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
}
],
"trust": 1.3232667500000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
}
]
},
"last_update_date": "2025-05-17T03:50:00.886000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.0
},
{
"problemtype": "Cross-site request forgery (CWE-352) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://github.com/tianhui999/mycve/blob/main/ac1206/ac1206-2.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-42078"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-42078/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-728"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-728"
},
{
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"date": "2023-10-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"date": "2022-10-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-728"
},
{
"date": "2022-10-12T19:15:09.623000",
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87936"
},
{
"date": "2023-10-20T06:17:00",
"db": "JVNDB",
"id": "JVNDB-2022-018524"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-728"
},
{
"date": "2025-05-15T19:15:55.343000",
"db": "NVD",
"id": "CVE-2022-42078"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-728"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Cross-site request forgery vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018524"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-728"
}
],
"trust": 0.6
}
}
VAR-202210-0843
Vulnerability from variot - Updated: 2025-05-17 03:47Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a heap overflow via sched_start_time parameter. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports.
Tenda AC1206 firmware version US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 has a buffer overflow vulnerability. The vulnerability originates from the fact that the sched_start_time parameter in the setSchedWifi function on the /bin/httpd file/goform/openSchedWifi page lacks length verification for input data, and attackers can exploit the vulnerability result in a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0843",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23_multi_td01"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 multi td01"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206 us ac1206v1.0rtl v15.03.06.23 multi td01",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"cve": "CVE-2022-42080",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-87934",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-42080",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-42080",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-42080",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-42080",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-42080",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2022-87934",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-725",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-725"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a heap overflow via sched_start_time parameter. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. \n\r\n\r\nTenda AC1206 firmware version US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 has a buffer overflow vulnerability. The vulnerability originates from the fact that the sched_start_time parameter in the setSchedWifi function on the /bin/httpd file/goform/openSchedWifi page lacks length verification for input data, and attackers can exploit the vulnerability result in a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-42080"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "CNVD",
"id": "CNVD-2022-87934"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-42080",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-87934",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202210-725",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-725"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"id": "VAR-202210-0843",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
}
],
"trust": 1.3232667500000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
}
]
},
"last_update_date": "2025-05-17T03:47:47.106000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://github.com/tianhui999/mycve/blob/main/ac1206/ac1206-4.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-42080"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-42080/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-725"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-725"
},
{
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"date": "2023-10-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"date": "2022-10-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-725"
},
{
"date": "2022-10-12T19:15:09.747000",
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87934"
},
{
"date": "2023-10-20T06:15:00",
"db": "JVNDB",
"id": "JVNDB-2022-018522"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-725"
},
{
"date": "2025-05-15T19:15:55.687000",
"db": "NVD",
"id": "CVE-2022-42080"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-725"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018522"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-725"
}
],
"trust": 0.6
}
}
VAR-202505-0086
Vulnerability from variot - Updated: 2025-05-15 23:20A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been rated as critical. This issue affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of ac1206 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to launch attacks and cause buffer overflow
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202505-0086",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "lte",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 and earlier"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "lte",
"trust": 0.6,
"vendor": "tenda",
"version": "\u003c=15.03.06.23"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"cve": "CVE-2025-4299",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-4299",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-004924",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-09668",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-4299",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-4299",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-004924",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-4299",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-4299",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-004924",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-09668",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been rated as critical. This issue affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of ac1206 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to launch attacks and cause buffer overflow",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-4299"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "CNVD",
"id": "CNVD-2025-09668"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-4299",
"trust": 3.2
},
{
"db": "VULDB",
"id": "307403",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09668",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"id": "VAR-202505-0086",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
}
],
"trust": 1.0465335
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
}
]
},
"last_update_date": "2025-05-15T23:20:49.183000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://vuldb.com/?id.307403"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.563558"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-4299"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.307403"
},
{
"trust": 1.0,
"url": "https://github.com/ch13hh/tmp_store_cc/blob/main/ac1206/ac1206setschedwifi/setschedwifi.md"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"date": "2025-05-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"date": "2025-05-06T00:15:16.620000",
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09668"
},
{
"date": "2025-05-14T06:26:00",
"db": "JVNDB",
"id": "JVNDB-2025-004924"
},
{
"date": "2025-05-13T20:06:00.377000",
"db": "NVD",
"id": "CVE-2025-4299"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-004924"
}
],
"trust": 0.8
}
}
VAR-202210-0758
Vulnerability from variot - Updated: 2025-05-15 23:13Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via sched_end_time parameter. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. The vulnerability comes from the fact that the sched_end_time parameter of the setSchedWifi function in /goform/openSchedWifi in the /bin/httpd file lacks the length verification of the input data. Attackers can exploit the vulnerability to cause Denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0758",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23_multi_td01"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23 multi td01"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206 us ac1206v1.0rtl v15.03.06.23 multi td01",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"cve": "CVE-2022-42081",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-87933",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-42081",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-42081",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-42081",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-42081",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-42081",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2022-87933",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-723",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-723"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via sched_end_time parameter. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC1206 is a high-performance router designed with gigabit ports for both WAN and LAN ports. The vulnerability comes from the fact that the sched_end_time parameter of the setSchedWifi function in /goform/openSchedWifi in the /bin/httpd file lacks the length verification of the input data. Attackers can exploit the vulnerability to cause Denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-42081"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "CNVD",
"id": "CNVD-2022-87933"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-42081",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-87933",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202210-723",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-723"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"id": "VAR-202210-0758",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
}
],
"trust": 1.3232667500000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
}
]
},
"last_update_date": "2025-05-15T23:13:53.543000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://github.com/tianhui999/mycve/blob/main/ac1206/ac1206-5.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-42081"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-42081/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-723"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-723"
},
{
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"date": "2023-10-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"date": "2022-10-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-723"
},
{
"date": "2022-10-12T19:15:09.797000",
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-87933"
},
{
"date": "2023-10-20T06:14:00",
"db": "JVNDB",
"id": "JVNDB-2022-018521"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-723"
},
{
"date": "2025-05-15T16:15:29.400000",
"db": "NVD",
"id": "CVE-2022-42081"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-723"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018521"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-723"
}
],
"trust": 0.6
}
}
VAR-202504-0757
Vulnerability from variot - Updated: 2025-04-20 23:32A vulnerability was found in Tenda AC1206 15.03.06.23. It has been classified as critical. Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid/timeZone leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. AC1206 is a high-performance wireless router designed for broadband users of 200M and above. The vulnerability is caused by the form_fast_setting_wifi_set function of the /goform/fast_setting_wifi_set file not performing a valid boundary check on the input of the ssid or timeZone parameters, resulting in a buffer overflow. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202504-0757",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.6,
"vendor": "jixiang tengda",
"version": "15.03.06.23"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"cve": "CVE-2025-3328",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-3328",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-002999",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-07591",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-3328",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-002999",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-3328",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-002999",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-07591",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC1206 15.03.06.23. It has been classified as critical. Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid/timeZone leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. AC1206 is a high-performance wireless router designed for broadband users of 200M and above. The vulnerability is caused by the form_fast_setting_wifi_set function of the /goform/fast_setting_wifi_set file not performing a valid boundary check on the input of the ssid or timeZone parameters, resulting in a buffer overflow. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-3328"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "CNVD",
"id": "CNVD-2025-07591"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-3328",
"trust": 3.2
},
{
"db": "VULDB",
"id": "303540",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-07591",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"id": "VAR-202504-0757",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
}
],
"trust": 1.0465335
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
}
]
},
"last_update_date": "2025-04-20T23:32:34.300000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/ch13hh/tmp_store_cc/blob/main/ac1206/ac1206form_fast_setting_wifi_set/form_fast_setting_wifi_set.md"
},
{
"trust": 1.8,
"url": "https://github.com/ch13hh/tmp_store_cc/blob/main/ac1206/ac1206form_fast_setting_wifi_set_time/time.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.303540"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.551893"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-3328"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.303540"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"date": "2025-04-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"date": "2025-04-07T01:15:42.953000",
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-07591"
},
{
"date": "2025-04-08T02:45:00",
"db": "JVNDB",
"id": "JVNDB-2025-002999"
},
{
"date": "2025-04-07T18:17:37.687000",
"db": "NVD",
"id": "CVE-2025-3328"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002999"
}
],
"trust": 0.8
}
}
VAR-202307-0870
Vulnerability from variot - Updated: 2025-01-07 23:26Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. Shenzhen Tenda Technology Co.,Ltd. of F1202 firmware, ac1206 firmware, FH1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-0870",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1202",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1202",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"cve": "CVE-2023-37712",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37712",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-37712",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37712",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-37712",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-37712",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-532",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. Shenzhen Tenda Technology Co.,Ltd. of F1202 firmware, ac1206 firmware, FH1202 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37712"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37712",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019244",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202307-532",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"id": "VAR-202307-0870",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.6766223
},
"last_update_date": "2025-01-07T23:26:24.820000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246057"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/fromsetipbind"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37712"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37712/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
},
{
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"date": "2023-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-532"
},
{
"date": "2023-07-10T17:15:09.877000",
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-12T08:04:00",
"db": "JVNDB",
"id": "JVNDB-2023-019244"
},
{
"date": "2023-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-532"
},
{
"date": "2025-01-06T17:15:13.680000",
"db": "NVD",
"id": "CVE-2023-37712"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019244"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-532"
}
],
"trust": 0.6
}
}
VAR-202410-1948
Vulnerability from variot - Updated: 2024-11-13 23:09A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter arg of the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 in the file /goform/ate failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202410-1948",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "lte",
"trust": 1.0,
"vendor": "tenda",
"version": "2024-10-27"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 2024-10-27 and earlier"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "lte",
"trust": 0.6,
"vendor": "tenda",
"version": "\u003c=2024-10-27"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"cve": "CVE-2024-10434",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-10434",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-011875",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-44511",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-10434",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2024-10434",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-011875",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-10434",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-10434",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2024-011875",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2024-44511",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the parameter arg of the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 in the file /goform/ate failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-10434"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "CNVD",
"id": "CNVD-2024-44511"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-10434",
"trust": 3.2
},
{
"db": "VULDB",
"id": "281985",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-44511",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"id": "VAR-202410-1948",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
}
]
},
"last_update_date": "2024-11-13T23:09:01.587000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/physicszq/routers/blob/main/tenda/readme.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.281985"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.431291"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-10434"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.281985"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"date": "2024-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"date": "2024-10-28T01:15:02.273000",
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-44511"
},
{
"date": "2024-11-05T04:53:00",
"db": "JVNDB",
"id": "JVNDB-2024-011875"
},
{
"date": "2024-11-01T16:32:05.137000",
"db": "NVD",
"id": "CVE-2024-10434"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011875"
}
],
"trust": 0.8
}
}
VAR-202410-1497
Vulnerability from variot - Updated: 2024-11-07 22:35A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202410-1497",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.19\\(6318\\)"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.48.23"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.2.13"
},
{
"model": "ac500",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.16"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.20"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.09"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "ac500",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.14"
},
{
"model": "ac500",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.9\\(1307\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.19"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.18"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.19\\(6318\\)"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.48.19"
},
{
"model": "ac10u",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.48"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.05"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac10u",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.49"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.14"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10u",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac500",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"cve": "CVE-2024-10280",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-10280",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 6.8,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-011851",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2024-10280",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2024-10280",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-011851",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-10280",
"trust": 1.0,
"value": "High"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-10280",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-011851",
"trust": 0.8,
"value": "High"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-10280"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-10280",
"trust": 2.6
},
{
"db": "VULDB",
"id": "281555",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011851",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"id": "VAR-202410-1497",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.4059792066666667
},
"last_update_date": "2024-11-07T22:35:04.235000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-476",
"trust": 1.0
},
{
"problemtype": "NULL Pointer dereference (CWE-476) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/johenanli/router_vuls/blob/main/websreadevent/websreadevent.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.281555"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.426417"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.281555"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-10280"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"date": "2024-10-23T14:15:04.500000",
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-05T02:27:00",
"db": "JVNDB",
"id": "JVNDB-2024-011851"
},
{
"date": "2024-11-01T14:03:20.267000",
"db": "NVD",
"id": "CVE-2024-10280"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 In the product \u00a0NULL\u00a0 Pointer dereference vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011851"
}
],
"trust": 0.8
}
}
VAR-202410-0264
Vulnerability from variot - Updated: 2024-11-07 22:29A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of ac1206 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202410-0264",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": "lt",
"trust": 0.6,
"vendor": "tenda",
"version": "15.03.06.23"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"cve": "CVE-2024-9793",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2024-9793",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2024-011800",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-41056",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2024-9793",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2024-9793",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-011800",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-9793",
"trust": 1.0,
"value": "Medium"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-9793",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2024-011800",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2024-41056",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of ac1206 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-9793"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "CNVD",
"id": "CNVD-2024-41056"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-9793",
"trust": 3.2
},
{
"db": "VULDB",
"id": "279946",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-41056",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"id": "VAR-202410-0264",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
}
]
},
"last_update_date": "2024-11-07T22:29:14.483000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [ others ]",
"trust": 0.8
},
{
"problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/ixout/iotvuls/blob/main/tenda/ac1206_003/report.md"
},
{
"trust": 1.8,
"url": "https://github.com/ixout/iotvuls/blob/main/tenda/ac1206_004/report.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.279946"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.418061"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.279946"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-9793"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2024-9793/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-10-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"date": "2024-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"date": "2024-10-10T16:15:09.080000",
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-10-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-41056"
},
{
"date": "2024-11-05T01:07:00",
"db": "JVNDB",
"id": "JVNDB-2024-011800"
},
{
"date": "2024-11-01T14:36:02.277000",
"db": "NVD",
"id": "CVE-2024-9793"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-011800"
}
],
"trust": 0.8
}
}
VAR-202208-1778
Vulnerability from variot - Updated: 2024-08-14 15:42Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit port router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1778",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"cve": "CVE-2022-37801",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78498",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37801",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37801",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37801",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37801",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78498",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3867",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
},
{
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit port router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37801"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "CNVD",
"id": "CNVD-2022-78498"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37801",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78498",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3867",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
},
{
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"id": "VAR-202208-1778",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
}
]
},
"last_update_date": "2024-08-14T15:42:15.432000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78498)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361281"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205854"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/9"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37801"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37801/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
},
{
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
},
{
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3867"
},
{
"date": "2022-08-25T15:15:10.260000",
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78498"
},
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015487"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3867"
},
{
"date": "2022-08-26T13:57:39.343000",
"db": "NVD",
"id": "CVE-2022-37801"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015487"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3867"
}
],
"trust": 0.6
}
}
VAR-202208-2030
Vulnerability from variot - Updated: 2024-08-14 15:42Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the speed_dir parameter in the function formSetSpeedWan. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-2030",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"cve": "CVE-2022-37809",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78516",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37809",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37809",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37809",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37809",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78516",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3850",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
},
{
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the speed_dir parameter in the function formSetSpeedWan. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37809"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "CNVD",
"id": "CNVD-2022-78516"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37809",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78516",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3850",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
},
{
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"id": "VAR-202208-2030",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
}
]
},
"last_update_date": "2024-08-14T15:42:15.225000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78516)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361226"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205839"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/11"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37809"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37809/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
},
{
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
},
{
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3850"
},
{
"date": "2022-08-25T15:15:10.603000",
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78516"
},
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015479"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3850"
},
{
"date": "2022-08-26T13:55:47.793000",
"db": "NVD",
"id": "CVE-2022-37809"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015479"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3850"
}
],
"trust": 0.6
}
}
VAR-202307-1183
Vulnerability from variot - Updated: 2024-08-14 15:41Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1183",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "3.0"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"cve": "CVE-2023-37717",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37717",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37717",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1259",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"db": "VULMON",
"id": "CVE-2023-37717"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37717",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37717",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"id": "VAR-202307-1183",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5256526420000001
},
"last_update_date": "2024-08-14T15:41:40.794000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda F1202 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247158"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromdhcplistclient/repot.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37717/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37717"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1259"
},
{
"date": "2023-07-14T00:15:09.477000",
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1259"
},
{
"date": "2023-07-21T14:31:56.167000",
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
],
"trust": 0.6
}
}
VAR-202308-3714
Vulnerability from variot - Updated: 2024-08-14 15:36Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3714",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "fh1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"cve": "CVE-2023-38936",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-38936",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38936",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-38936",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-38936",
"trust": 0.8,
"value": "Critical"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38936"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38936",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021659",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"id": "VAR-202308-3714",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.3288697725
},
"last_update_date": "2024-08-14T15:36:47.021000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetspeedwan/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38936"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"date": "2023-08-07T19:15:11.343000",
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"date": "2023-08-10T18:20:51.897000",
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
}
],
"trust": 0.8
}
}
VAR-202208-1931
Vulnerability from variot - Updated: 2024-08-14 15:32Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1931",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"cve": "CVE-2022-37816",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78519",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37816",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37816",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37816",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37816",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78519",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3844",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
},
{
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37816"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "CNVD",
"id": "CNVD-2022-78519"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37816",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78519",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3844",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
},
{
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"id": "VAR-202208-1931",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
}
]
},
"last_update_date": "2024-08-14T15:32:33.655000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78519)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361211"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205420"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/13"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37816"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37816/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
},
{
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
},
{
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"date": "2023-09-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3844"
},
{
"date": "2022-08-25T15:15:10.903000",
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78519"
},
{
"date": "2023-09-26T08:24:00",
"db": "JVNDB",
"id": "JVNDB-2022-015302"
},
{
"date": "2022-08-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3844"
},
{
"date": "2022-08-25T23:01:18.797000",
"db": "NVD",
"id": "CVE-2022-37816"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015302"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3844"
}
],
"trust": 0.6
}
}
VAR-202307-0808
Vulnerability from variot - Updated: 2024-08-14 15:26Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-0808",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.47"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"cve": "CVE-2023-37711",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37711",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-37711",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37711",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-37711",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-529",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
},
{
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37711"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37711",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019245",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202307-529",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
},
{
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"id": "VAR-202307-0808",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.36157598
},
"last_update_date": "2024-08-14T15:26:32.795000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246054"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/saveparentcontrolinfo"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37711"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37711/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
},
{
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
},
{
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"date": "2023-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-529"
},
{
"date": "2023-07-10T17:15:09.837000",
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-12T08:04:00",
"db": "JVNDB",
"id": "JVNDB-2023-019245"
},
{
"date": "2023-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-529"
},
{
"date": "2023-07-13T19:47:18.553000",
"db": "NVD",
"id": "CVE-2023-37711"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 firmware and \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019245"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-529"
}
],
"trust": 0.6
}
}
VAR-202308-4213
Vulnerability from variot - Updated: 2024-08-14 15:26Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-4213",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"cve": "CVE-2023-38937",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-38937",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38937",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-38937",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-38937",
"trust": 0.8,
"value": "Critical"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38937"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38937",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021658",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"id": "VAR-202308-4213",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.3871988366666666
},
"last_update_date": "2024-08-14T15:26:26.130000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetvirtualser/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38937"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"date": "2023-08-07T19:15:11.413000",
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"date": "2023-08-10T18:22:01.703000",
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
}
],
"trust": 0.8
}
}
VAR-202208-1780
Vulnerability from variot - Updated: 2024-08-14 15:16Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromDhcpListClient. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda.
There is a buffer overflow vulnerability in Tenda AC1206 V15.03.06.23, which can be exploited by attackers to cause buffer overflow or heap overflow
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1780",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"cve": "CVE-2022-37806",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78512",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37806",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37806",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37806",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37806",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78512",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3854",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
},
{
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromDhcpListClient. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC1206 V15.03.06.23, which can be exploited by attackers to cause buffer overflow or heap overflow",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37806"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "CNVD",
"id": "CNVD-2022-78512"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37806",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78512",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3854",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
},
{
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"id": "VAR-202208-1780",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
}
]
},
"last_update_date": "2024-08-14T15:16:31.600000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78512)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361246"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205843"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/4"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37806"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37806/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
},
{
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
},
{
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3854"
},
{
"date": "2022-08-25T15:15:10.473000",
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78512"
},
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015482"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3854"
},
{
"date": "2022-08-26T13:56:49.377000",
"db": "NVD",
"id": "CVE-2022-37806"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015482"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3854"
}
],
"trust": 0.6
}
}
VAR-202208-1777
Vulnerability from variot - Updated: 2024-08-14 15:06Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter at the function setSmartPowerManagement. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1777",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"cve": "CVE-2022-37799",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78520",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37799",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37799",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37799",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37799",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78520",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3869",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
},
{
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter at the function setSmartPowerManagement. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37799"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "CNVD",
"id": "CNVD-2022-78520"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37799",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78520",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3869",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
},
{
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"id": "VAR-202208-1777",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
}
]
},
"last_update_date": "2024-08-14T15:06:13.462000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78520)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361206"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205856"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/2"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37799"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37799/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
},
{
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
},
{
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3869"
},
{
"date": "2022-08-25T15:15:10.177000",
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78520"
},
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015489"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3869"
},
{
"date": "2022-08-26T13:58:27.540000",
"db": "NVD",
"id": "CVE-2022-37799"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015489"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3869"
}
],
"trust": 0.6
}
}
VAR-202208-1903
Vulnerability from variot - Updated: 2024-08-14 15:06Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1903",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"cve": "CVE-2022-37808",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78514",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37808",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37808",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37808",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37808",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78514",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3852",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
},
{
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37808"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "CNVD",
"id": "CNVD-2022-78514"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37808",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78514",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3852",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
},
{
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"id": "VAR-202208-1903",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
}
]
},
"last_update_date": "2024-08-14T15:06:13.319000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78514)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361236"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205841"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/15"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37808"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37808/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
},
{
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
},
{
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3852"
},
{
"date": "2022-08-25T15:15:10.563000",
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78514"
},
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015480"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3852"
},
{
"date": "2022-08-26T13:56:41.110000",
"db": "NVD",
"id": "CVE-2022-37808"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015480"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3852"
}
],
"trust": 0.6
}
}
VAR-202208-1945
Vulnerability from variot - Updated: 2024-08-14 15:06Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. Shenzhen Tenda Technology Co.,Ltd. of ac1206 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-1945",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"cve": "CVE-2022-37810",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37810",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37810",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37810",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37810",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3856",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
},
{
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. Shenzhen Tenda Technology Co.,Ltd. of ac1206 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37810"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37810",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015478",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3856",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
},
{
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"id": "VAR-202208-1945",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.45665634
},
"last_update_date": "2024-08-14T15:06:13.275000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda AC1206 Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205845"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/19"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37810"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37810/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
},
{
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
},
{
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3856"
},
{
"date": "2022-08-25T15:15:10.650000",
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015478"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3856"
},
{
"date": "2023-08-08T14:21:49.707000",
"db": "NVD",
"id": "CVE-2022-37810"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015478"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3856"
}
],
"trust": 0.6
}
}
VAR-202208-2008
Vulnerability from variot - Updated: 2024-08-14 15:06Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-2008",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac1206",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac1206 firmware 15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"cve": "CVE-2022-37802",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-78501",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-37802",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-37802",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-37802",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-37802",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2022-78501",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-3866",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
},
{
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC1206 is a wireless through-the-wall Gigabit router produced by China Tenda. An attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-37802"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "CNVD",
"id": "CNVD-2022-78501"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-37802",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-78501",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3866",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
},
{
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"id": "VAR-202208-2008",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
}
],
"trust": 1.05665634
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
}
]
},
"last_update_date": "2024-08-14T15:06:13.216000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC1206 buffer overflow vulnerability (CNVD-2022-78501)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/361276"
},
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205853"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/darry-lang1/vuln/tree/main/tenda/ac1206/6"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-37802"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-37802/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
},
{
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
},
{
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"date": "2023-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"date": "2022-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3866"
},
{
"date": "2022-08-25T15:15:10.300000",
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-78501"
},
{
"date": "2023-09-27T08:44:00",
"db": "JVNDB",
"id": "JVNDB-2022-015486"
},
{
"date": "2022-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-3866"
},
{
"date": "2022-08-26T13:57:28.747000",
"db": "NVD",
"id": "CVE-2022-37802"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015486"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-3866"
}
],
"trust": 0.6
}
}
VAR-202307-1134
Vulnerability from variot - Updated: 2024-08-14 15:05Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1134",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.47"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"cve": "CVE-2023-37710",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37710",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-37710",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37710",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-37710",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-530",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
},
{
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Shenzhen Tenda Technology Co.,Ltd. of AC10 firmware and ac1206 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37710"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37710",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019246",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202307-530",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
},
{
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"id": "VAR-202307-1134",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.36157598
},
"last_update_date": "2024-08-14T15:05:34.334000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda AC1206 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246055"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/firmrec/iot-vulns/tree/main/tenda/fromsetwirelessrepeat"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37710"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37710/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
},
{
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
},
{
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"date": "2023-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-530"
},
{
"date": "2023-07-10T17:15:09.797000",
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-12T08:04:00",
"db": "JVNDB",
"id": "JVNDB-2023-019246"
},
{
"date": "2023-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-530"
},
{
"date": "2023-07-13T19:47:08.147000",
"db": "NVD",
"id": "CVE-2023-37710"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 firmware and \u00a0ac1206\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019246"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-530"
}
],
"trust": 0.6
}
}