Search criteria
12 vulnerabilities found for 762-4202\/8000-001_firmware by wago
CVE-2020-12069 (GCVE-0-2020-12069)
Vulnerability from nvd – Published: 2022-12-26 00:00 – Updated: 2025-04-14 16:17
VLAI?
Title
CODESYS V3 prone to Inadequate Password Hashing
Summary
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.
Severity ?
7.8 (High)
CWE
- CWE-916 - Use of Password Hash With Insufficient Computational Effort
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS V3 containing the CmpUserMgr |
Affected:
V3 , < V3.5.16.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:58.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download="
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-061/"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-031/"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-022/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-12069",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T16:17:42.834492Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-14T16:17:54.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS V3 containing the CmpUserMgr",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.16.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device."
}
],
"value": "In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-916",
"description": "CWE-916 Use of Password Hash With Insufficient Computational Effort",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-15T05:40:17.087Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download="
},
{
"tags": [
"vendor-advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-061/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-031/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-022/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CODESYS V3 prone to Inadequate Password Hashing",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-12069",
"datePublished": "2022-12-26T00:00:00.000Z",
"dateReserved": "2020-04-22T00:00:00.000Z",
"dateUpdated": "2025-04-14T16:17:54.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34569 (GCVE-0-2021-34569)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 19:17
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Write
Summary
In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.
Severity ?
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34569",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T19:17:25.396965Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T19:17:39.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"impacts": [
{
"capecId": "CAPEC-123",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-123 Buffer Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:36.366Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Write",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34569",
"datePublished": "2022-11-09T15:17:36.366Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T19:17:39.712Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34568 (GCVE-0-2021-34568)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service.
Severity ?
7.5 (High)
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34568",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:11.257503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:17.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-130",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-130 Excessive Allocation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:29.795Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34568",
"datePublished": "2022-11-09T15:17:29.795Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:17.218Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34567 (GCVE-0-2021-34567)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Read
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read.
Severity ?
8.2 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:33.137134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:39.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"impacts": [
{
"capecId": "CAPEC-540",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-540 Overread Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:23.429Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Read",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34567",
"datePublished": "2022-11-09T15:17:23.429Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:39.270Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34566 (GCVE-0-2021-34566)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:21
VLAI?
Title
WAGO I/O-Check Service prone to Memory Overflow
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS.
Severity ?
9.1 (Critical)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:21:03.913921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:21:10.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:14.172Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Memory Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34566",
"datePublished": "2022-11-09T15:17:14.172Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:21:10.643Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3281 (GCVE-0-2022-3281)
Vulnerability from nvd – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
VLAI?
Title
WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
Summary
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
Severity ?
7.5 (High)
CWE
- CWE-440 - Expected Behavior Violation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxx Series PFC100/PFC200 |
Affected:
03.01.07(13) , ≤ 03.10.08(22)
(custom)
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:07:06.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3281",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-10T02:56:08.488527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-10T02:56:32.932Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "750-81xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "750-8217/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.04.10(16)",
"versionType": "custom"
}
]
},
{
"product": "750-82xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "Compact Controller CC100",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.09.08(21)",
"status": "affected",
"version": "03.07.17(19)",
"versionType": "custom"
}
]
},
{
"product": "762-4xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-5xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-6xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "752-8303/8000-002 Edge Controller",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.06.09(18)",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-10-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-440",
"description": "CWE-440 Expected Behavior Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-02T00:00:00.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"source": {
"advisory": "VDE-2022-042",
"defect": [
"CERT@VDE#64236"
],
"discovery": "INTERNAL"
},
"title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
"x_generator": {
"engine": "vulnogram 0.1.0-rc1"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-3281",
"datePublished": "2022-10-17T08:20:12.389Z",
"dateReserved": "2022-09-23T00:00:00.000Z",
"dateUpdated": "2025-05-10T02:56:32.932Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12069 (GCVE-0-2020-12069)
Vulnerability from cvelistv5 – Published: 2022-12-26 00:00 – Updated: 2025-04-14 16:17
VLAI?
Title
CODESYS V3 prone to Inadequate Password Hashing
Summary
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.
Severity ?
7.8 (High)
CWE
- CWE-916 - Use of Password Hash With Insufficient Computational Effort
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS V3 containing the CmpUserMgr |
Affected:
V3 , < V3.5.16.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:58.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download="
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-061/"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-031/"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-022/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-12069",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T16:17:42.834492Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-14T16:17:54.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS V3 containing the CmpUserMgr",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.16.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device."
}
],
"value": "In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-916",
"description": "CWE-916 Use of Password Hash With Insufficient Computational Effort",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-15T05:40:17.087Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download="
},
{
"tags": [
"vendor-advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-061/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-031/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-022/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CODESYS V3 prone to Inadequate Password Hashing",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-12069",
"datePublished": "2022-12-26T00:00:00.000Z",
"dateReserved": "2020-04-22T00:00:00.000Z",
"dateUpdated": "2025-04-14T16:17:54.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34569 (GCVE-0-2021-34569)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 19:17
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Write
Summary
In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.
Severity ?
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34569",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T19:17:25.396965Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T19:17:39.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"impacts": [
{
"capecId": "CAPEC-123",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-123 Buffer Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:36.366Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Write",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34569",
"datePublished": "2022-11-09T15:17:36.366Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T19:17:39.712Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34568 (GCVE-0-2021-34568)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service.
Severity ?
7.5 (High)
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34568",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:11.257503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:17.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-130",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-130 Excessive Allocation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:29.795Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34568",
"datePublished": "2022-11-09T15:17:29.795Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:17.218Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34567 (GCVE-0-2021-34567)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Read
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read.
Severity ?
8.2 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:33.137134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:39.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"impacts": [
{
"capecId": "CAPEC-540",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-540 Overread Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:23.429Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Read",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34567",
"datePublished": "2022-11-09T15:17:23.429Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:39.270Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34566 (GCVE-0-2021-34566)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:21
VLAI?
Title
WAGO I/O-Check Service prone to Memory Overflow
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS.
Severity ?
9.1 (Critical)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:21:03.913921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:21:10.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:14.172Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Memory Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34566",
"datePublished": "2022-11-09T15:17:14.172Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:21:10.643Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3281 (GCVE-0-2022-3281)
Vulnerability from cvelistv5 – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
VLAI?
Title
WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
Summary
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
Severity ?
7.5 (High)
CWE
- CWE-440 - Expected Behavior Violation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxx Series PFC100/PFC200 |
Affected:
03.01.07(13) , ≤ 03.10.08(22)
(custom)
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:07:06.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3281",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-10T02:56:08.488527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-10T02:56:32.932Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "750-81xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "750-8217/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.04.10(16)",
"versionType": "custom"
}
]
},
{
"product": "750-82xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "Compact Controller CC100",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.09.08(21)",
"status": "affected",
"version": "03.07.17(19)",
"versionType": "custom"
}
]
},
{
"product": "762-4xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-5xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-6xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "752-8303/8000-002 Edge Controller",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.06.09(18)",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-10-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-440",
"description": "CWE-440 Expected Behavior Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-02T00:00:00.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"source": {
"advisory": "VDE-2022-042",
"defect": [
"CERT@VDE#64236"
],
"discovery": "INTERNAL"
},
"title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
"x_generator": {
"engine": "vulnogram 0.1.0-rc1"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-3281",
"datePublished": "2022-10-17T08:20:12.389Z",
"dateReserved": "2022-09-23T00:00:00.000Z",
"dateUpdated": "2025-05-10T02:56:32.932Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}