Search criteria
12 vulnerabilities found for 750-8101\/025-000_firmware by wago
CVE-2021-34569 (GCVE-0-2021-34569)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 19:17
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Write
Summary
In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.
Severity ?
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34569",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T19:17:25.396965Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T19:17:39.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"impacts": [
{
"capecId": "CAPEC-123",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-123 Buffer Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:36.366Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Write",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34569",
"datePublished": "2022-11-09T15:17:36.366Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T19:17:39.712Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34568 (GCVE-0-2021-34568)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service.
Severity ?
7.5 (High)
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34568",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:11.257503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:17.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-130",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-130 Excessive Allocation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:29.795Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34568",
"datePublished": "2022-11-09T15:17:29.795Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:17.218Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34567 (GCVE-0-2021-34567)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Read
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read.
Severity ?
8.2 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:33.137134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:39.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"impacts": [
{
"capecId": "CAPEC-540",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-540 Overread Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:23.429Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Read",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34567",
"datePublished": "2022-11-09T15:17:23.429Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:39.270Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34566 (GCVE-0-2021-34566)
Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:21
VLAI?
Title
WAGO I/O-Check Service prone to Memory Overflow
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS.
Severity ?
9.1 (Critical)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:21:03.913921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:21:10.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:14.172Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Memory Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34566",
"datePublished": "2022-11-09T15:17:14.172Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:21:10.643Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3281 (GCVE-0-2022-3281)
Vulnerability from nvd – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
VLAI?
Title
WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
Summary
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
Severity ?
7.5 (High)
CWE
- CWE-440 - Expected Behavior Violation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxx Series PFC100/PFC200 |
Affected:
03.01.07(13) , ≤ 03.10.08(22)
(custom)
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:07:06.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3281",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-10T02:56:08.488527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-10T02:56:32.932Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "750-81xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "750-8217/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.04.10(16)",
"versionType": "custom"
}
]
},
{
"product": "750-82xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "Compact Controller CC100",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.09.08(21)",
"status": "affected",
"version": "03.07.17(19)",
"versionType": "custom"
}
]
},
{
"product": "762-4xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-5xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-6xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "752-8303/8000-002 Edge Controller",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.06.09(18)",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-10-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-440",
"description": "CWE-440 Expected Behavior Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-02T00:00:00.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"source": {
"advisory": "VDE-2022-042",
"defect": [
"CERT@VDE#64236"
],
"discovery": "INTERNAL"
},
"title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
"x_generator": {
"engine": "vulnogram 0.1.0-rc1"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-3281",
"datePublished": "2022-10-17T08:20:12.389Z",
"dateReserved": "2022-09-23T00:00:00.000Z",
"dateUpdated": "2025-05-10T02:56:32.932Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-22511 (GCVE-0-2022-22511)
Vulnerability from nvd – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
VLAI?
Title
WAGO PLCs WBM vulnerable to reflected XSS
Summary
Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Compact Controller CC100 (751-9301) |
Affected:
FW16 , < FW22
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:14:55.300Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Compact Controller CC100 (751-9301)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Edge Controller (752-8303/8000-002)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Series PFC100 (750-81xx/xxx-xxx)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Series PFC200 (750-82xx/xxx-xxx)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "FW16 FW22"
}
]
},
{
"product": "Series Touch Panel 600 Marine Line (762-6xxx)",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "FW16 FW22"
}
]
},
{
"product": "Series Touch Panel 600 Standard Line (762-4xxx)",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "FW16 FW22"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
}
],
"datePublic": "2022-03-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-09T19:38:43",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
}
],
"solutions": [
{
"lang": "en",
"value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
}
],
"source": {
"advisory": "VDE-2022-004",
"defect": [
"CERT@VDE#64068"
],
"discovery": "EXTERNAL"
},
"title": "WAGO PLCs WBM vulnerable to reflected XSS",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
"ID": "CVE-2022-22511",
"STATE": "PUBLIC",
"TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Compact Controller CC100 (751-9301)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Edge Controller (752-8303/8000-002)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series PFC100 (750-81xx/xxx-xxx)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series PFC200 (750-82xx/xxx-xxx)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
"version": {
"version_data": [
{
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
"version": {
"version_data": [
{
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
"version": {
"version_data": [
{
"version_name": "FW16",
"version_value": "FW22"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
}
],
"source": {
"advisory": "VDE-2022-004",
"defect": [
"CERT@VDE#64068"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-22511",
"datePublished": "2022-03-09T19:38:43.516457Z",
"dateReserved": "2022-01-03T00:00:00",
"dateUpdated": "2024-09-17T00:16:00.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34569 (GCVE-0-2021-34569)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 19:17
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Write
Summary
In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.
Severity ?
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34569",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T19:17:25.396965Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T19:17:39.712Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
}
],
"impacts": [
{
"capecId": "CAPEC-123",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-123 Buffer Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:36.366Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Write",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34569",
"datePublished": "2022-11-09T15:17:36.366Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T19:17:39.712Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34568 (GCVE-0-2021-34568)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service.
Severity ?
7.5 (High)
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34568",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:11.257503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:17.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-130",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-130 Excessive Allocation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:29.795Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34568",
"datePublished": "2022-11-09T15:17:29.795Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:17.218Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34567 (GCVE-0-2021-34567)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
VLAI?
Title
WAGO I/O-Check Service prone to Out-of-bounds Read
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read.
Severity ?
8.2 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34567",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:20:33.137134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:20:39.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
}
],
"impacts": [
{
"capecId": "CAPEC-540",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-540 Overread Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:23.429Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Out-of-bounds Read",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34567",
"datePublished": "2022-11-09T15:17:23.429Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:20:39.270Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34566 (GCVE-0-2021-34566)
Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:21
VLAI?
Title
WAGO I/O-Check Service prone to Memory Overflow
Summary
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS.
Severity ?
9.1 (Critical)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxxFW |
Affected:
FW1 , ≤ FW18 Patch 2
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-34566",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T14:21:03.913921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T14:21:10.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "750-81xx/xxx-xxxFW",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "750-82xx/xxx-xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "752-8303/8000-0002",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-4xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-5xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "762-6xxx",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "FW18 Patch 2",
"status": "affected",
"version": "FW1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
}
],
"datePublic": "2021-06-29T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-09T15:17:14.172Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
}
],
"source": {
"advisory": "VDE-2020-036",
"discovery": "EXTERNAL"
},
"title": "WAGO I/O-Check Service prone to Memory Overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34566",
"datePublished": "2022-11-09T15:17:14.172Z",
"dateReserved": "2021-06-10T19:19:08.023Z",
"dateUpdated": "2025-05-01T14:21:10.643Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3281 (GCVE-0-2022-3281)
Vulnerability from cvelistv5 – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
VLAI?
Title
WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
Summary
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
Severity ?
7.5 (High)
CWE
- CWE-440 - Expected Behavior Violation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | 750-81xx/xxx-xxx Series PFC100/PFC200 |
Affected:
03.01.07(13) , ≤ 03.10.08(22)
(custom)
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:07:06.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3281",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-10T02:56:08.488527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-10T02:56:32.932Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "750-81xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "750-8217/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.04.10(16)",
"versionType": "custom"
}
]
},
{
"product": "750-82xx/xxx-xxx Series PFC100/PFC200",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.08(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "Compact Controller CC100",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.09.08(21)",
"status": "affected",
"version": "03.07.17(19)",
"versionType": "custom"
}
]
},
{
"product": "762-4xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-5xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "762-6xxx Series Touch Panel 600",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.01.07(13)",
"versionType": "custom"
}
]
},
{
"product": "752-8303/8000-002 Edge Controller",
"vendor": "WAGO",
"versions": [
{
"lessThanOrEqual": "03.10.09(22)",
"status": "affected",
"version": "03.06.09(18)",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-10-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-440",
"description": "CWE-440 Expected Behavior Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-02T00:00:00.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
}
],
"source": {
"advisory": "VDE-2022-042",
"defect": [
"CERT@VDE#64236"
],
"discovery": "INTERNAL"
},
"title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
"x_generator": {
"engine": "vulnogram 0.1.0-rc1"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-3281",
"datePublished": "2022-10-17T08:20:12.389Z",
"dateReserved": "2022-09-23T00:00:00.000Z",
"dateUpdated": "2025-05-10T02:56:32.932Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-22511 (GCVE-0-2022-22511)
Vulnerability from cvelistv5 – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
VLAI?
Title
WAGO PLCs WBM vulnerable to reflected XSS
Summary
Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WAGO | Compact Controller CC100 (751-9301) |
Affected:
FW16 , < FW22
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
Credits
These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:14:55.300Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Compact Controller CC100 (751-9301)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Edge Controller (752-8303/8000-002)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Series PFC100 (750-81xx/xxx-xxx)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Series PFC200 (750-82xx/xxx-xxx)",
"vendor": "WAGO",
"versions": [
{
"lessThan": "FW22",
"status": "affected",
"version": "FW16",
"versionType": "custom"
}
]
},
{
"product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "FW16 FW22"
}
]
},
{
"product": "Series Touch Panel 600 Marine Line (762-6xxx)",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "FW16 FW22"
}
]
},
{
"product": "Series Touch Panel 600 Standard Line (762-4xxx)",
"vendor": "WAGO",
"versions": [
{
"status": "affected",
"version": "FW16 FW22"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
}
],
"datePublic": "2022-03-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-09T19:38:43",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
}
],
"solutions": [
{
"lang": "en",
"value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
}
],
"source": {
"advisory": "VDE-2022-004",
"defect": [
"CERT@VDE#64068"
],
"discovery": "EXTERNAL"
},
"title": "WAGO PLCs WBM vulnerable to reflected XSS",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
"ID": "CVE-2022-22511",
"STATE": "PUBLIC",
"TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Compact Controller CC100 (751-9301)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Edge Controller (752-8303/8000-002)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series PFC100 (750-81xx/xxx-xxx)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series PFC200 (750-82xx/xxx-xxx)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
"version": {
"version_data": [
{
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
"version": {
"version_data": [
{
"version_name": "FW16",
"version_value": "FW22"
}
]
}
},
{
"product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
"version": {
"version_data": [
{
"version_name": "FW16",
"version_value": "FW22"
}
]
}
}
]
},
"vendor_name": "WAGO"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
}
],
"source": {
"advisory": "VDE-2022-004",
"defect": [
"CERT@VDE#64068"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-22511",
"datePublished": "2022-03-09T19:38:43.516457Z",
"dateReserved": "2022-01-03T00:00:00",
"dateUpdated": "2024-09-17T00:16:00.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",